EE Civil Pune
O/O EE Civil, BSNL Civil Dn MHS TE Pune-01
Maintenance and repairs to BSNL buildings under the jurisdiction of DGM (Central) Pune for the year 2023 SH Day to Day Maintenance.
2023_BSNL_152536_1
NIT No. e-04/EEC(P)/BSNL/2023-24
Open Tender
Civil Works
Item Rate
365 days
Pune
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Accounts Officer Cash BSNL Pune
₹7,200
18 May 2023
25 Apr 2023
3 May 2023
25 Apr 2023
1 May 2023
25 Apr 2023
Amount
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing aluminium carpentry fittings ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary nuts & screws etc complete as dirceted by Engineer in charge.a) Single rubber hanging floor door stopper
b) Sliding door bolts 300x 16mm
c) Sliding door latch 250X15 X 9mm
d) Handles 125 mm
e) Butt hinges 100x75x4 mm
f) Tower bolts 150x10 mm
g) Aluminium extruded section body tubular type universal hydraulic door closer confiriming to IS:3564 with necessary accessories and screws etc complete
Extra for taking out damaged carpentry fitting in above item and disposal of damaged fitting including credit of scrap value of damaged fittings etc complete as dirceted by Engineer in charge.
Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Renewing glass panes with putty and nails wherever necessary including racking out the old putty: a) '(i) Float glass panes of thickness 4 mm
Renewal of old putty of glass panes (length) .
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing & fixing BWR Grade commercial plywood of ISI make & brand (Kitply,Greenply or equivalent) of required shape & size in furniture works including cost of adhesive, rawl plugs, screws, nails etc. complete as directed by the Engineer-in-Charge. a] 19 mm thick
Providing and fixing powder coated aluminium "Star lock" of approved quality,grade & shade for Aluminium silding window with necessary screws etc.complete
Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: 90mm
Repairs to modular partition with M.S.frame structure and both side 12mm thk particle board by removing particle board from place including clips & again refixing the particle board properly at place with necessary C.P.brass screws etc.complete as per direction of the Engineer-In-Charge.
Repairs to existing wooden flush door shutter by first removing the shutter from its position repairing the same by replacing the damaged portion by suitable material with zig-zag pins, screws, nails, including replacing the hinges if required and plaining the edges if required and making it operational properly and refixing the same to its original position etc all complete as directed by Engineer in charge.
Repairs to existing Single leaf aluminium door shutter upto 1.00m width by removing the shutter from its position, fixing Aluminium corner brackets (L-Shape with four holes) of approved quality on both faces using nut & bolts of suitable size at four corners of shutter to ensure proper fixity and alignment of vertical door styles & refixing the door shutter to its original position etc. all complete as directed by Engineer-in-charge.
Easening of doors and windows etc. from stiffened state including oiling/ tightening of hinges, correcting alignment and other minor repairs without requirement of additional materials other than oil/ nails, screws etc. for its smooth and proper functioning complete, all as directed by the Engineer-in-Charge.
Repairs to bottle/ tubular type door closer including making torque adjustment of spring control screws, tightening of screws of lever arm and body, checking of smooth door movement etc. complete.
Repairs to existing aluminium sliding window by first removing the shutter from its position, replacing the bearings of each shutter & changing the lock (if necessary) ( lock to be paid seperately) & refixing the window shutter to its original position so that making it operational properly all complete as directed by Engineer in charge a) a) For single shutter of aluminium sliding window
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. a) For thickness of tiles 10 mm to 25 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc, complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : a) W.C. pan with ISI marked white solid plastic seat and lid
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Removing of choke up inside quarters in kitchen, bath room, WC waste pipe line from inside the building so as to make it opertional etc all complete as directed by Engineer in Charge.
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed withwater. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Spraying solution of Ammonium Salt of Glyphosate 71% SG (100 gm mixed with 900 ml of water) on all leaves of saplings grown on walls, C.I.pipe joints etc of building at all floor levels of building for entrie building upto V floor whenever required throughout the year.
Cleaning of sewer line upto 300mm dia by rodding, scrubbing and flushing to remove the clogged drain of sludge, waste & rubbish material and disposal of waste/ refuge/ filth etc. (recovered in this process) to a place permitted and approved by the Local Municipal corporation all as per the direction of Engineer-in-Charge.
Cleaning of Manholes by rodding , scrubbing and flushing to remove the clogged drain of sludge , waste & rubbish material and disposal where corporation dumping places etc as per the direction of Engineer in charge
Dismantling G.I. pipes external work including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : a] 15 mm to 40 mm nominal bore
Dismantling of (C.I./PVC/Vitreous China) flushing cistern of any size including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: a) Of area 3 sq. metres and below
Disposal / Carriage of dismantled material/ debris/ malba, upto 2.83 cum per trip by mechanical transport to the dumping ground permitted by PMC.(up to 20Km from site) including loading unloading all complete as per direction of the Engr - in charge, beyond 50 m initial lead, for all leads including all lifts involved.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse crushed stone sand, filling thejoints with stone dust etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
Providing and fixing plumbing fittings etc complete as dirceted by Engineer in charge. a) 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
b) White solid plastic seat with lid for pedestal type W.C. pan complete :
c) Flexible type P.V.C. waste pipe 32 mm dia
d) Flat back white vitreous wash basin of size 550x400mm including making all connections but excluding the cost of fittings.
e) C.P. brass bib / stop cock 15 mm nominal bore
f) C.P. brass pillar cock 15 mm nominal bore
g) C.P.brass spreader to existing urinal
h) Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush /brass union 15 mm nominal bore with 45 cm length
i) PTMT, push cock 15 mm nominal bore, 98mm long. Weighing not less than 75 gms.
j) PTMT bib cock/ stop cock 15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
k) PTMT pillar cock 15mm nominal bore, 107mm long. Weighing not less than 110 gms.
Extra for taking out damaged plumbing fitting under above item, disposal of damaged fitting and credit of scrap value of damaged fittings etc complete as dirceted by Engineer in charge.
Providing and fixing 10 litre capacity - White P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings & fixtures complete:
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. a) 15 mm nominal bore, 105 mm long, weighing not less than 138 gms
b) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms
c) 25 mm nominal bore, 152mm long, weighing not less than 440 gms
d) 40 mm nominal bore, 206mm long, weighing not less than 690 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall a) 15 mm nominal outer dia. Pipes.
b) 20 mm nominal outer dia. Pipes.
c) 25 mm nominal outer dia .Pipes.
d) 32 mm nominal outer dia. Pipes.
e) 40 mm nominal outer dia. Pipes.
f) 50 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work a) 25 mm nominal outer dia. Pipes.
b) 40 mm nominal outer dia. Pipes.
c) 50 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. a) 20 mm nominal outer dia .Pipes.
b) 25 mm nominal outer dia .Pipes.
c) 32 mm nominal outer dia .Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. ( external work ) a) 25 mm dia nominal bore
b) 40 mm dia. nominal bore
c) 50 mm dia. nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : a) 25 mm diameter pipe
b) 40 mm diameter pipe
c) 50 mm diameter pipe
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : a) b) 15 mm nominal bore.
b) 20 mm nominal bore.
c) 25 mm dia nominal bore
d) 40 mm dia nominal bore
e) 50 mm dia nominal bore
Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints, p & F clips with nails etc all complete as per direction of Engineer in Charge. a) 15 mm nominal outer dia. pipes.
b) 20 mm nominal outer dia. pipes.
c) 25 mm nominal outer dia. pipes.
d) 32 mm nominal outer dia. pipes.
e) 40 mm nominal outer dia. pipes.
f) 50 mm nominal outer dia. pipes.
Providing and fixing on wall face unplasticised PVC SWR soil, waste and vent pipes and fittings conforming to IS : 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc at all heights including providing & fixing clamps, nails, cutting and making good walls, floors etc all complete as per direction of Engineer in Charge. a) 110 mm dia
b) 75 mm dia
c) Plain Bend : 110 mm dia
d) Plain Bend : 75 mm dia
e) Plug Bend /angular Bend bend: 110 mm dia
f) Plug Bend /angular Bend bend : 75 mm dia
Providing and fixing 25 mm nominal dia. UPVC Ball valve including jointing with one step UPVC solvent cement & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing 25 mm nominal dia. UPVC non rteturn valve including jointing with one step UPVC solvent cement & testing of joints complete as per direction of Engineer in Charge.
Removing & refixing bib cock, stop cock from existing toilet and refixing the same at new locations after renovation of toilet etc all complete
Providing and fixing c. p. brass toilet paper holder
Supplying chemical emulsion in sealed containers including delivery as specified. A) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : a) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
P & F stainless steel folding handles of approved quality including fixing with necessary metal screws etc all complete as directed by the Engineer-in-Charge.
P & F stainless steel bhingri of approved quality including fixing with necessary metal screws to wooden shutters etc all complete as directed by the Engineer-in-Charge.
P & F stainless steel wire mesh to the exhaust fan in toilet/kitchen to arrest entry of mosquetoes with necessary fixing material etc all complete as directed by the Engineer-in-Charge.
Repairs to drawers of plywood cupboard including removing the drawer, plaining surplus edges and making operations smoothly including required material etc all complete as directed by the Engineer-in-Charge.
Repairs to PVC overhead water tanks including removing existing G.I conections if required, welding the cracks by PVC material and refixing the tank in position with all connections including replacing the tank nipples if necessary etc. all complete as directed by engineer in charge:- Water tanks up to 2000 lit capacity including all damage patches)
P & F health fauscet of ABS material with 1.5 metre long S.S. braided rubber hose pipe of quality and make as approved by Engineer - in - charge.
Supplying and fixing C.I. cover without frame for manholes : a) 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of LD 2.5 grade of required shape and approved quality a) Rectangular shape upto 600x450mm internal dimensions
b) 230x300mm internal dimensions
Repairs to PVC flushing cisterns by replacing unserviceable components with new component (Cost of component to be paid for seperately) and making the cistern operational complete as directed.
Repair to 15mm size bib cock, pillar cock, stop cock including change of defective items to stop leakage/ smooth working as directed by Engineer-In-Charge
Supplying of component for repairing works including credit of scrap value and cost of disposal of the damaged component after the repairing work. A) PVC handle knob for flush tank.
b) PVC flusher for flush tank
c) PVC float valve for flush tank .
d) Brass spindle for bib / stop / pillar cock
Repairing/ replacing of external 15mm to 50mm G.I. water supply pipe line from chock-up or other obstruction or for replacement of rusted G.I. Pipe line (cost of new G.I. Pipe to be paid separately) including removing the pipe from union/ bend/ sockets/ tees etc., clearing the chock-up and refixing the pipe to its original position, including cost of replacement of damaged sockets, bends, tees etc. (excluding unions), as required, for proper water supply using necessary scaffolding, jhoola, drop-cage etc. required to carry out the work complete, all as per direction of Engineer-in-charge.
Providing and fixing S. S. Jali of 100mm dia.over nahani trap etc complete as diected.
P/F gun metal gate valve with Patti of approved quality ( screwed end ) a ) 15mm nominal bore
(b ) 25mm nominal bore
(c) 40mm nominal bore
(d ) 50mm nominal bore
Providing and fixing PTMT Nahani trap including cost of cutting and making good the walls and floors
Providing and fixing PVC cover to PVC Over head water tank (capacity upto 2000 lit) with necessary screws, nutbolts etcall complete as per direction of Engineer-in-charge.
Fixing of bajri glass louvers upto size 55 cm x 10 cm & 4 mm thick in louvered window including necessary cutting etc.complete as directed by Engineer in charge.
Filling gap between floor top and rain water outlet pipe at slab level with cement mortar 1:3 mixed with waterproofing compound and finishing with floating coat of neat cement as directed by Engineer in charge.
Disconnecting C. P. Brass urinal spreader & its connections with stop cock including removal of connection puipe, cleaning the spreader from inside, cleaning choked holes etc all complete as per direction of Engineer-in-charge.
Providing & fixing HDPE bird net having 50 mm Square openings (Garware or equivalent make) to wondow openings (upto 2 sqm) with necessary J-hooks, screws, plastic ties including fitting to walls upto 4 floors from outside of the building including necessary zoola etc all complete as directed by Engineer in charge.
Deduct for not providing hinges in doors, windows or clerestory window shutters with : ISI marked Stainless steel butt hinges with stainless steel screws :For 2nd class teak wood and other class of wood shutters
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .