Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹30.3 L+₹2.8 L (10.2%)Rejected-Finance | L2 | Rejected-Finance Bonafide but Not being lowest | |
| 3 | L3₹35.5 L+₹8.0 L (29.0%)Rejected-Finance | L3 | Rejected-Finance Bonafide but Not being lowest | |
| 4 | L4₹36.8 L+₹9.3 L (33.8%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L4 | Rejected-Finance Bonafide but Not being lowest | |
| 5 | L5₹37.3 L+₹9.8 L (35.7%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-Finance Bonafide but Not being lowest |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
30 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MR ARIZ AHMED
GE U ELECTRIC SUPPLY DELHI CANTT
Repair and maintenance to 33 11 KV Kirby Grid in the area of AGE U Elect Supply No I under GE U Elect Supply Delhi Cantt 10
2020_MES_346449_1
GE ELECT/D-19/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
6 Jul 2020
2 Jun 2020
2 Jul 2020
3 Jun 2020
30 Jun 2020
18 Jun 2020
60 days
Amount
M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 2 here-in -after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required and directed
Material and labour for servicing /testing of line circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor SF 6 Gas Circuit Breaker of capacity 1250/800 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust and wear. (vi) Checking of spring charge mechanism (vii) Visual check for rust and deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Replacement of Dashpot/shock absorbers . (xiii) Replacement of carbon brush of spring charging motor (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (ii) Line diffrential relay (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Trip Circuit suprvision relay (ii) SF 6 gas pressure low. (iii) PT Fuse failure relay (iv) Master trip relay (v) Under voltage relay (vi) Over voltage relay
Material and labour for servicing /testing of transformer circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor SF 6 Gas Circuit Breaker of capacity 1250/800 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust and wear. (vi) Checking of spring charge mechanism (vii) Visual check for rust and deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Replacement of Dashpot/shock absorbers . (xiii) Replacement of carbon brush of spring charging motor (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault Relay (ii) Transformer diffrential relay (d) Testing of followig Aux relay (i) DC supply supervision relay. (ii) CB SF 6 gas pressure low. (iii) Master trip relay (iv) Main Buchholz trip (v) Buchholz OLTC Trip (vi) SPR & PRV trip. (vii) Winding temp high trip (viii) Oil temp high trip. (ix) Main Buchholz alarm (x) Winding temp High alarm (xi) Low Oil level alarm (xii) Oil temp high alarm
Material and labour for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 2000 /800/630 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust.
(xiii) Replace the jaw contacts,If required. (xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (d) Testing of followig Aux relay (i) DC Supply supervision relay. (ii) Master trip relay
S&F in replacement of closing coil assembly 50 volts DC of existing make for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as directed by Engr -in-Charge.
S&F in replacement of tripping coil assembly 50 volts DC of existing make for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as directed by Engr -in-Charge.
S&F in replacement of closing coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as directed by Engr -in-Charge.
S&F in replacement of tripping coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as directed by Engr -in-Charge.
Material & labour for repair /servicing of marshalling box panel of 33KV/11KV Power transformer of capacities 12 / 16 MVA including follwing :- (a) Testing & repair to control wiring. (b) Testing of OTI, WTI gauge/ meter matching with OTI, WTI indicator in RTCC panel. (c) Testing of fuse/ MCB (d) Repalacement of gaskets & locks including preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of etc complete all as specified and directeed.
Material & labour for repair /servicing of marshalling box panel of 33KV/11KV Power transformer of capacities 10 & 10 / 8 MVA including follwing :- (a) Testing & repair to control wiring. (b) Testing of OTI, WTI gauge/ meter matching with OTI, WTI indicator in RTCC panel. (c) Testing of fuse/ MCB (d) Repalacement of gaskets & locks including preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of etc complete all as specified and directeed.
Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV outdoor brakers with spraying machine including writing description of equipment in block English letter 50 mm high with white /black synthetic enamel paint complete all as directed by Engr -in-Charge.
Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of Terminal Kiosk (TK) at 33 KV Yard with spraying machine including writing description of equipment in block English letter 25 mm high with white /black synthetic enamel paint complete all as directed by Engr -in-Charge.
Material and labour for Preparation of old painted surfaces of 33 KV Switch yard including all outer steel structures/ frame/gate of bus bay at Grid, having dimensions 54 m x 11.5m x 9.5m and steel housing of capacitor bank having dimension 6m x 4.4m x 4m (incluiding top closed) by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) with spraying machine in the yard including writing description of equipments in block English letters 100 mm high with white/black synthetic enamel paint complete all as specified and directed.
Disconnecting power supply, Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV 12/16 MVA transformer and its accessories with spraying machine in the yard including writing description of equipment in block English letter 50 mm high with white/Black synthetic enamel paint and re-connection after painting complete all as specified and directed.
All as per item No 15 here-in -before but capacity of power transformer 10 & 8/10 MVA.
Material & labour for cleaning of the bay/yard (60 RM x 17.5 RM) manually without damaging any equipments, cable or parts of the 33 KV Grid bays, removing of dusts/grass/hurbs etc all as directed by Engr -in-charge.
Material and labour for sprading of stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface all as specified and directed
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.
Supplying and Fixing in repairs, male/moving contact/ rotating blade of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and directed.
Supplying and Fixing in repairs, Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and directed.
Supplying and fixing of terminal pad for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity
Supplying and fixing of arching horn for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity
Supply , installation, testing and commissioning in replacement of air bake off load line isolator switch rotating type manually gear drive mechanism operated highest system voltage 36 KV rated current 1250 Amps triple pole with earthing device each pole consist of insulating pedestals 03 Nos on galvanized steel base as per BSS /IS incuding rotating blade of HDE copper and fixed contacts of same material , spring loaded arcing horns of adequate section to brake magnetizing current of transformer as directed with adequate 50mm dia GI operating pipe for operation from ground level and operating handle complete with both off and on positions complete all as specified and directed.
All as per item No 24 above but bus isolator without earthing device
Supplying ,fixing , testing of master trip relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying ,fixing , testing of Trip circuit supervision relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying ,fixing , testing of DC supervision relay relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying ,fixing , testing of SF 6 gas pressure supervision relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying and fixing PT fuse for 11 KV/110 V PT complete as directed at site
Supply installation, testing and commissioning in replacement Potential Transformer (PT) oil cooled out door single phase ( Earthed type) of voltage ratio 33 KV/110 V class 3P - 0.5-3, burden 50 VA insulation level of 70/170 KV as specified below:- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary voltage- 33 KV/√3 (d) Rated secondary voltage- 110 V/√3 (e) Nos of Lt winding 2 (f) Metering Core Accuracy class - 0.5 (g) Metering Core Rated Burden- 50 VA (h) Nos of Phase- Single (Earthed Type) (j) Protection core accuracy class - 3P (k) Protection core rated Burden - 50 VA (l) Rated Voltage Factor - 1.2 continuous & 1.5 for 30 Sec (m) Insulation Level- 36/70 KV.170 KVP (n) Temp rise at rated contineous thermal current over ambient at site - 45 0C (o) Porcelain Bushing type - Hollow Cylinder (p) 1.2/50 mcro second impulse withstand test vol -170 KV (Peak) (q) Creepage distance of HV bushing - 900 mm (min) (r) Primary & Secondary winding material - Copper
Supply, installation, testing and commissioning in replacement 33 KV current transformer oil cooled out door single phase, oil immersed and self cooled type of ratio 800-400/1-1-1-1 suitable for metering and protection equipment installed on control panels terminal block as specified below :- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary current- 800-400 Amp (d) Rated secondary current- 1 Amp (e) Nos of Core - 4 (f) Core01: Accuracy class 5P10, 10VA, ALF ≥10 (g) Core02: Accuracy Class 1.0, 10VA, ISF ≤ 5 (h) Core 03 Protection core accuracy class -PS,Protection knee point voltage- 300 Volt at lower ratio (j) Core 04-Spare (k) Continuous thermal current rating 120 % of rated primary current (l)Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C (m) Insulation Level- 36/70 KV.170 KVP (n) 1.2/50 Micro second impulse withstand test voltage- 170 KV (peak) (o) Short time thermal current rating for one second - 25 KA/1 Second (p) Dynamic Current Rating - 62.5 KA ( peak) (q) Porcelain Bushing type - Hollow Cylinder (r) Creepage distance of HV bushing - 900 mm (min) (s) Primary & Secondary winding material - Copper
S&F steel structure with ISMB/Channel/Angle iron/flat , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint at 33 KV yard for fixing of isolator/CT/PT and for fixing of GO/DO etc complete as directed by Engr -In-Charge.
Taking out of heavy duty colling fan ,3 phase, 50 Hz of size 600mm form power transformer 33/11 KV of capacity 12/16 MVA ,servicing of the fan by opening including cleaning, greasing , replacement of defective spares parts such as bearing/ bushing, capacitor, canopy, clamp, blade, etc with new one and painting of fan body with synthetic enamel paint and re-assembling in same position after repairs and testing complete all as directed by Engr-in-Charge. Note :- (a) The cost of spare parts deemed to be included in quoted rates . (b) Rewinding of the fan will be measured and paid separately under respective item of schedule here-in-after.
M&L for Rewinding of heavy duty colling fan, 3 phase, 50 Hz of size 600mm of power transformer 33/11 KV capacity with super enamelled copper wire as per existing gauge including heating, varnishing, etc complete as required and directed.
Maintanance services to be provided for 33 /11 KV Kirby grid as per details as under:- (a) The installation is main receiving station and complaint centre minimume 02 electrician shall be provided per shift (Total Three Shifts per day ) round the clock (24x7) .The electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electrician giving reasoned rejection.No claim shall be admissible on account of rejection of person. (b) Details of equipment:-Transformer step down 33/11 KV capacity 12/16 MVA ,10 MVA & 08/10 MVA capacity incl marshal boxes ,accessories & control cables complete -03 Nos , Indoor type transformer stepdown 11 KV/433 Volts capacity 100 KVA -01 Nos , Outdoor type SF-6 circuit breaker 33 KV -07 Nos, Control panel 33 KV breaker -08 Nos , 11 KV VCB as incomer including control panel -03 Nos , 11 KV Bus Coupler including control panel -02 No , 11 KV VCB as outgoing including control panel -27 Nos,33 & 11 KV Capacitor bank complete with control panel -02 No, LT panel -01 Nos,RTCC Panel for 12/16 MVA,10 MVA & 08/10 MVA transformer -03 Nos, batery charger -02 Nos, Battery bank 50 volts DC -02 Nos, & Terminal KIOSK -08 Nos, Solar system with charging control panel ( Batteries 08 Nos, Solar modules 20 Nos). (c) The followingchecking/testing,supervision shall be carried out by electrician in respect of equpments mentioned at at para (b) above:-
(i) Recording of all parameters of system as per indication of all equipments installed in the log sheets directed by Engr-in-Charge round the clock on daily basis. (ii) Maintainance of fault register (iii) Maintainance of shutdown register (iv) Proper operatiion of 33 KV and 11 KV Breaker (v) Giving of Shutdown by draw out of trolley of breaker . (vi) Proper operation of 33 KV Islolator (vii) Checking of status of LED indication for breaker on , off , trip , spring charge , trip circuit healthy on daily basis. (viii) Checking of status of annunciator, hooter , indicators , meters, TNC switch , emergency trip push button , MCB for AC DC isolation, heater , thermostate on daily basis. (ix) Checking of status of Transformer differential relay , line differential relay , main protection numerical relay, Auxillary protection relays such as trip circuit supervision , master trip , PT fuse failure , DC supervision ,CB SF 6 gas pressure low, Main Buchholz trip ,Buchholz OLTC Trip, SPR & PRV trip, Winding temp high trip ,Oil temp high trip. Main Buchholz alarm, Winding temp High alarm, Low Oil level alarm, Oil temp high alarm, and keeping all the relays in reset condition on daily basis.
(x) Cheking of Oil temprature of transformer oil as directed by Engr-in-charge. (xi) Checking of winding temprature of transformer as directed by Engr-in-Charge. (xii) Checking of oil level of transformer as directed by Engr-in-Charge. (xiii) Checking the batteries in serviceable and charged condition by checking battery, leads, battery lugs on daily basis. (xiv) Attending of all complaint of the grid. (xv) Cleaning of dust & foreign particles on and around the panel, loose connection earthing connection in the control room and yard. (xvi) Checking of condition of leakage of oil from transformer tank, bushing, radiators and other parts on weekly basis (xv) Checking of cooling fans on weekly baisis. (xvi) Checking condition of silica gel on weekly basis (xvii) Testing BDV of transformer oil as directed by Engr-in -Charge. (xviii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xix) Checking of DC voltage of system as directed by Engr -in-charge
Supplying, installation, commissioning and testing of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 300/150/5-5 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering and associated wiring including taking down old UNSV CTs complete all as specified and directed
Supplying, installation, commissioning and testing of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 250/125/5-5 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering and associated wiring including taking down old UNSV CTs complete all as specified and directed
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast bar Primary type having ratio 1200/600/5-5-5 Amps , core -1, Class 10 P20 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, core -3 for differential protection , Short circuit time rating 18.4 kA for 3 Sec including associated wiring complete all as specified and directed
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast bar Primary type having ratio 800/400/5-5-5 Amps , core -1, Class 10 P20 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering including associated wiring complete all as specified and directed
S&F in replacement of vacuum interrupter suitable for 1250 amps, 11 KV HT VCB complete all as specified and directed
Material and labour for topping up of / filling of SF-6 gas to achieve required gas pressure in 36 KV SF6 breaker and testing complete all as directed by Engr-in -charge.
Supply and laying PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sq mm 10 core 1100 Volts grade complete all as specified and directed.
All as per item No. 43 above but 2.5 sqmm 6 core copper conductor.
M&L for Bore earthig 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 115mm C/C on both side of the pipe including lowering in bore well upto the depth of 49 mtr and one mtr above the ground level. The pipe electrode should be filled around commericial salt charcoal dust, copper suphate and magnesium phosphate of 30 cm layer each upto the full length of pipe. The borewell should have 12 mtr of length 150mm dia MS pipe for protection of borewell. Welding of GI Strip 50mmx6mm on earth electrode GI Pipe 50mm dia upto 10mtr below ground level and 15 mtr from the bore well to test point gun metal and PCC foundation surrounding the borewell 60cmx60cmx30cm all as directed by Engr-in-charge. GI strip more than 25mtr will be measured and paid separately. Note :- Cost of gun metal test point deemed to be included in the quoted rate.
Material & labour for repair /overhauling/Servicing of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 MVA at site by carried out following work of make :- Schenider (a) Opening of top plate of OLTC. (b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC. (d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact. (e) Flushing of OLTC assembly with hot new oil and removing of sludge. (f) Filling of new transformer oil in OLTC . (g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling. (i) Electrical testing of manual/auto operation of OLTC. Note :- Transformer oil as required shall be measured and paid separately under item No 2 here-in -before as supply only.
Supplying and Fixing in replascement, T-connector/ clamps, aluminium cast alloy suitable for existing ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specifed and directed.
S&F in replacement CT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all specified and directed
S&F in replacement PT clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with Ginuts bolts complete all as specified and directed
Supplying and Fixing in replacement, PG clamps aluminium cast alloy suitable for existing ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard/33 KV towers with GI nuts, boits etc complete all as specified and directed.
S&F in replacement lsolators clamps aluminium cast alloy for both terminals suitable for ACSR conductor of type Zebra/Dog/Goat/Panther/Wolf for 33 KV yard with GI nuts bolts complete all as specified and directed.
M&L in replacement Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised iron side complete all as specified, including testing and commissioning complete all as directed. Note :- (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in soft/loose soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 type C2 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement 6mm dia both ways as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Buddham Builders
M/s Birja Nand
MV Engineers And Contractors
Vijay Electricals
Rajindera Enterprises
DS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .