Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹18.5 L+₹52,595 (2.93%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹19.7 L+₹1.8 L (9.97%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Aug 2022, 6:00 pmClosed
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/MAINT OF INTERNAL WIRING INCLUDING INTERNAL FITTINGS AND FIXTURE AND OTHER CONNECTED WORKS OF CERTAIN OTM AND MD ACCN OF JNE AREA, ASC BN, JOI MAP QTRS ANE GE OFFICE COMPLEX UNDER GE (NORTH) UDHAMPUR
2022_MES_540209_1
CWE/U(N)-50/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NORTH) UDHAMPUR
₹70,000
20 Aug 2022
22 Jul 2022
19 Aug 2022
22 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
Taking down carefully the existing Copper/ Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- Charge. Note : (i) Old dismanteled wiring and unservicable accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB DB and VTPN any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by Engr -in-charge.
Point wiring for one light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia , ISI marked terminated into annealed steel terminal boxes including 3 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc, complete all as specified and directed by the Engr-in-charge.
Point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multistranded copper conductor, medium grade ISI meraked drwan into and including PVC concealed conduit 25 mm bore with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly, complete all as specified and directed by Engr -in-charge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch, complete all as specified and directed by Engr -in-charge.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 above but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controle by 2 Nos.of two way switch, complete all as specified and directed by Engr -in-charge.
Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 sqmm drawn in and incl PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for two way point wiring , complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board with cable1.5 sqmm size, complete all as specified and directed by Engr -in-charge.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
Switch Piano flush type single pole two way 5/15 Amps, complete all as specified and directed by Engr -in-charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
Switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked, complete all as specified and directed by Engineer- in - Charge.
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location, complete all as directed by Engineer- in - Charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 26, complete all as directed by Engineer- in - Charge.
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM, complete all as directed by Engineer- in - Charge.
All as per item No. 28 herein before but with 6 sqmm (2x6 sqmm) pvc copper conductor cable through pvc conduit ISI marked with 6 sqmm copper conductor cable as earth contiunity conductor, complete all as directed by Engineer- in - Charge.
All as per item No. 28 herein before but with 1.5 sqmm (2x1.5 sqmm) pvc copper conductor cable through pvc conduit ISI marked with 1.5 sqmm copper conductor cable as earth contiunity conductor.
All as per item No. 28 herein before but with 2.5 sqmm (2x2.5 sqmm) pvc copper conductor cable through pvc conduit ISI marked with 2.5 sqmm copper conductor cable as earth contiunity conductor.
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by engineer incharge.
Sheet metal enclosures for distribution board when MCB to be used SPN 4 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 08 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as directed by Engr-in-Charge.
Sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection, complete all as directed by Engr-in-Charge.
S&F in repair Thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 KA including making necessary arrangement, complete all as specified and directed by Engr -in-charge.
S&F in repair Thermal magnetic MCCB 4 pole 100 Amps 415 Volts 16 KA including making necessary arrangement, complete all as specified and directed by Engr -in-charge.
S&F in repair Thermal magnetic MCCB 4 pole 125/160 Amps 415 Volts 16 KA including making necessary arrangement, complete all as specified and directed by Engr -in-charge.
MCB SPN 40 to 63 Amp 240V, 50Hz, 10kA 'C' series including Connection and testing for lighting and other domesitc loads incl necessary copper lugs etc , fixed in repair complete all as specified and as directed by engineer in charge.
MCB SP 6-32 Amps 'C' series Connection and testing , fixed in repair complete all as specified and as directed by engineer in charge.
MCB SP 40-63 Amps 'C' series Connection and testing , fixed in repair complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Fixing only LED Tube light fittings any type as obtained against item No 2 above complete with all fixing accessories, complete all as directed by Engineer- in - Charge.
S&H in repair Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed in repair complete all as specified and as directed by Engr-in-Charge.
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing fixed in repair complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
LED decorative down light fitting/ recess mounted panel (2' x 2') surface mounted lighting fixture 36 Watt LED, with diffuser, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting fixed in repair complete all as per the directions of Engr-in-Charge.
MCB TPN Four pole, 63 Amps, 240 V/415V fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Plug and socket DBs, single pole and neutral enclosure with a two pin earth plug and socket with one single 20 Amps, 240 volts MCB fixed in replacement, complete all as specified and as directed by engineer-in-charge.
S&F in repairs Switch Piano flush type single pole two way 5 Amps, complete all as specified and directed by Engr -in-charge.
S&F in repairs Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch Piano flush type for bell push 5 Amps One way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch socket combination piano box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Switch socket combination piano box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
S&F in repairs Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
S&F in repairs Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge
S&F in repairs Modular fan step regulator 120W 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs Modular switch 01 way 06A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs Modular switch 01 way 16A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs Modular bell push flush type 6A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
S&F in repairs PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep / 4-moudle including making necessary cutting fixed in replacement, complete all as specified and as directed by engineer in charge.
S&F in repairs PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep / 6- moudle including making necessary cutting fixed in replacement, complete all as specified and as directed by engineer in charge.
S&F in repairs 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc fixed in replacement, complete all as specified and as directed by engineer in charge.
S&F in repairs 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc fixed in replacement, complete all as specified and as directed by engineer in charge.
M&L for Disconnecting all electrical connection from MCB DB TPN/ Wall Mounted Panel Box for reconnecting the same with providing proper copper bottle lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire, complete all as specified and directed by the Engr-in-Charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase, complete all as specified and directed by the Engr-in-Charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing not exceeding 45 Cm defth, and not exceeding 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing, complete all as specified and directed by the Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, fixed in replacement, complete all as specified and directed by Engr-in-charge.Including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in RCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) 4 mm dia galvanised earth lead wire 7.5m. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Supply and fix in repair Energy saving LED garden light fitting decorative , bollard type of capacity 9/11 watt with opal diffuser, Aluminum reflector complete with all accessaries and fixing arrangement on PCC block of size 45mm X 45 mm alogwith fixing nuts , bolts and PVC insulated aluminum conductor stranded type of size 4.0 sqmm 2- core including taking down old unservicebe garden light fittings any type and wattage, complete all as specified and as directed by engineer-in-charge.
Supply and fixing LED Street Light fitting 25/35 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating (Make of LED shall be CREE/Necia/Osram) LED including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge. Note for BOQ item No 45 to 49, 79 & 80 : (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Supply & fix in repair driver for LED panel light fitting (2'x2'), 36 watts , 240 volts AC 50 Hz electronic type, complete all as specified and as directed by engineer-in-charge.
Supply & fix in repair LED street / buiding ligh fitting driver for 25/35 watts , 240 volts AC 50 Hz electronic type, complete all as specified and as directed by engineer-in-charge.
Supply and fix in repair decorative LED gate light fitting of 30/40 watt , 240 volts diecast aluminum housing in pure polyster powder coated gray finish top maintainable product with opening die cast cover , anti corrossive stainless steel screws & silicon gasket HET PMMA diffuser IP65 protection driver duly prewired up to terminal on firms to IS 10322 part 5 / sec, 1:1987 suitable for pole of dia 65-75 mm in - built electronic driver complete including taking down old / unserviceable gate light fitting, complete all as specified and as directed by engineer-in-charge.
S & F in repair service cable armored of size 4 sqmm 2 core , 1100 volts grade , heavy duty cable with PVC insulated stranded aluminum conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old / unserviceable service wire, complete all as specified and as directed by engineer-in-charge.
Description all as per srl item No 84 here-in-before but of size 6 Sqmm 2 core.
Description all as per srl item No 84 here-in-before but of size 10 Sqmm 2 core.
DEV RAJ MAGOTRA
M/S PEE BEE SALES CORORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .