Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.0 L+₹1.0 L (4.18%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹27.8 L+₹3.8 L (15.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹28.5 L+₹4.5 L (18.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹29.0 L+₹5.0 L (20.8%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
23 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF VARIOUS UNITS AND CERTAIN MD ACCNS FOR BUILDINGS AND EXTERNAL ELECTRIC SUPPLY AT BAIRAGARH UNDER GE BHOPAL
2023_MES_634765_1
8259/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹95,000
Yes
21 Mar 2024
28 Dec 2023
25 Jan 2024
28 Dec 2023
23 Jan 2024
11 Jan 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for concealed point wiring for one light/fan point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked controlled by one way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC Casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface including laminated hylum sheet cover, ISI marked of Make "Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule. Rate includes chase cutting for concealed wiring.
All as per item No. 2.00 here-in-before but for one light point controlled by two 2 way switches, with FRLS cables of 1.5 sqmm.
All as per item No. 2.00 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches.
All as per item No. 2.00 here-in-before, but for 3 pin 5 amp switch socket combination on independent board with other switch.
All as per item No. 2.00 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm.
All as per item No. 2.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
All as per item No. 2.00 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
M&L for point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core, FRLS cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLS cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including new laminated hylum sheet cover of min 3.0 mm thick, ISI marked of Make "Hylem" of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer complete all as specified and directed for the following. Note : Wiring to be done as per arroved colour code.
One light/fan point controlled by one switch.
One bell point controlled by one bell Push
One light point controlled by two 2-way switches.
One 5 Amps socket out let point controlled by one switch on independent board.
One 5 Amps socket out let point controlled by one switch on same board.
All as per item 9.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
All as per item 9.00 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in and including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make "Hylem" for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. Make of Cable : Polycab/ L&T/ Havells
One light/fan point controlled by one switch.
One call bell point controlled by one push button on the same board with other switces or independent.
One light point controlled by two 2-way switches.
One 3 pin socket outlet 5 Amps on independent board.
One 3 pin socket 5Amp outlet on same board with other switch.
All as per item 10.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
All as per item 10.00 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly
S&F of polycarbonate ceiling rose, surface type, 3 terminal, 240V, ISI marked, complete all as specified and directed.
S&F in repairs lamp holder, PVC/Poly carbonate type with back plate suitable for batten fittings including 9 watt LED lamp and all connected accessies complete all as specifieda and directed.
S&F of buzzer, Ding Dong AC, 230 volts, single pole complete all as specified and directed.
Taking down old unserviceable sub main wiring of any size and any description complete all as specified and directed.
S&F of modular switch one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular switch two way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular bell push, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular switch one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F modular fan regulator complete all as specified and directed.
S&F in replacement white cover plate with frame, 1 module, ISI marked complete all as specified and directed.
All as per item No 22.00 here-in-before but for 02 module.
All as per item No 22.00 here-in-before but for 04 module.
All as per item No 22.00 here-in-before but for 08 module.
S&F in replacement metal flush box 1/2 module complete all as specified and directed.
S&F in replacement metal flush box 04 module complete all as specified and directed.
S&F in replacement metal flush box 06 module complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
Taking down old unserviceable TPN / SPN MCB DB's including MCB of any size and any discription complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, TPN 415 Volts, 200 amps rated busbar, 4 way, double door, factory made Confirming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link and 200 amp, 440 volt rated bus bar suitable for mounting 63/100 Amp MCCB, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere IP-43 protection class . DB shall also be provided with lable marking indicating the incoming and outgoing circuit complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar, 4 way, double door (Vertical DB with MCB as incomer) factory made Confirming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link and 200 amp, 440 volt rated bus bar suitable for mounting 63/100 Amp MCCB as incomer, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere. DB shall also be provided with lable marking indicating the incoming and outgoing circuit IP-43 protection class complete all as specified and directed.
S&F in repairs MCCB TPN, 4 Pole, 63 Amps, 36 KA 'C' curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCCB TPN, 4 Pole, 100 Amps, 36 KA 'C' curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCCB TPN, 4 Pole, 250 Amps, 36 KA 'C' curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB TPN 100 Amps, 10 KA 'C' curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed
S&F in repairs MCB TPN 63 Amps, 10 KA 'C' curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 12 way double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 4 way double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F of MCB, SP, 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of MCB, SPN, 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of MCB, TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/ Schinder/L&T.
S&F of single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and directed.
Taking down existing fitting and supply and fixing in repairs LED tube light box type highly durable surface mounted LED batten constructed of fire retardant engineering grade extruded plastic and decorative end caps. 22/25 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System luminious efficacy > 100Lm/W, approx length 4 feet to be fixed in existing or new batten including taking down of existing tube light fitting and changing the wiring suitable for T8 LED tube light in existing tube light fitting complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron earth wire of 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 5 SSR including earth pit in any soil charcoal common salt, 15 mm all around earth plate PCC (1:3:6) type culprit, with 40 x40x6 mm angle iron frame and PCC cover (1:2:4) type B1, water pipe funnel and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel all as specified and directed. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate.
S&F of galvanised steel tubing, light grade, 50 mm dia fixed/ laid on floor/wall fixed with including GI clamps complete all as specified and directed.
S&F of galvanised steel tubing, light grade, 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including GI clamps complete all as specified and directed.
S&F of earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed.
S&F of bulk head luminare weather proof, including one number LED lamp 9W and connecting with copper flexible three core 23/0.0076 including all necessary fittings complete all as specified and directed.
S&F in replacement surface mounted economical LED panel light 2 ft x 2ft, 36/40 watt with high quality diffuser for uniform light, CRCA housing, separate replaceable electronic driver, suitable for recess and surface, CRCA panel 36/40 ECW including LED lamp, nut, wire all connected accessories complete all as specified and directed.
S&F in replacement surface mounted economical LED panel light 1ft x 1ft, 18/20 watt with high quality diffuser for uniform light, CRCA housing, separate replaceable electronic driver, suitable for recess and surface, CRCA panel 18/20 ECW including LED lamp, nut, wire all connected accessories complete all as specified and directed.
M&L for cutting PCC/floor/road for taking out/ laying of cable, GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc, size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
Taking down existing unserviceable fitting any type any size and supply and fixing of LED 9/10 Watt mirror tube light fitting intergated type, approx 2 feet, 240 V, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified and directed.
S&F in replacement garden light, including LED lamp 9 Watt, 220 volt, 50 Hz, Approx height 2 ft , mounting arrangemet, clamp, rcc pit of suitable size complete all as specified and directed.
Supply, laying and fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm nominal cross section 2 core in service connections including taking down old cable complete all as specified and directed.
Taking out old building security light and supply and fixing of building secutity light including GI Pipe of approx 1 mtr length and suitable size of led light of capacity 25 watt including weather protection cover nut, bolt and connected accessories complete all as specified and directed.
S&F of 9 Watt LED bulb, 220 volt, 50 Hz complete all as specified and directed.
S&F in replacement of 3 pin plug top AC-230 V 15 Amp complete all as specified and directed.
S&F in replacement of 3 pin plug top AC-230 v 5 Amp complete all as specified and directed.
S&F of 1 Sqmm x 3 core mutistranded copper conductor flexible wire, suitable for 220 Volts, 50 Hz, complete all as specified and directed.
S&F of cable 2.5 sq mm X 1 core FRLS suitable for garden light 220volt, 50 Hz complete all as specified and directed.
Taking down existing unserviceable light point wiring, fitting and fixtures and M&L for flame proof point wiring on wall surface wiring on ceiling with necessary fixing arrangements for one light point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper multistranded conductor of size 2.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all mild steel conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 2.5 sqmm, 1100 volts grade for continuous earthing making good the distrubed surface either by means of plaster of paris/ putti or distemper/ colour wash with same existing colour surfaces complete all as specfied and directed. Note:- (i) Junction box flame proof shall be measured and paid under relavent item. (ii) Earth wire shall be of green colour (iii) Colour code should be maintined
All as per item No.69.00 here-in-before but for fan point wiring
All as per item No.69.00 here-in-before but two light point controlled by one flame proof switch
All as per item No.69.00 here-in-before but power point wiring using 4 sqmm copper conductor cable and 4.0 sqmm as earth wire
M&L for sub main wiring with two single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERW rigid metallic steel conduit medium grade, ISI marked, 19/20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess with all mild steel conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable sub main wiring all as specified and directed. Note:- (i) Three runs of 4 sqmm copper conductor cable, and one run of ERW rigid metallic conduit will be measured as one unit.
S&F of flame proof junction box with spigotted cover in LM-6, three way/terminal block, 4 way, strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, duly approved by CMRI Dhanbad complete including taking down existing unserviceable junction boxes of any type and size complete all as specified and directed.
S&F of flame proof bend any radius of CI/MS with brass nickle threaded of size 20mm including taking down existing unserviceable flame proof bend of any type and size complete all as specified and directed.
S&F of flame proof union brass of size 20 mm complete including taking down existing unserviceable flame proof union brass of any type and size complete all as specified and directed.
S&F of flame proof plug brass of size 20 mm including taking down existing unserviceable flame proof plug brass of any type and size complete all as specified and directed.
S&F of flame proof flexible metalic hose conduit of size 3/4" dia and 300 mm long suitable for explosive atmosphere with explosive dust proof including taking down existing unserviceable metallic hose conduit of any type and size complete all as specified and directed
S&F of flame proof rotary switch in LM6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down existing unserviceable rotary switches of any type and size complete all as specified and directed.
S&F of flame proof switch socket outlet with plug combination in LM-6, 16 Amps, 250 Volts, two pin and earth with no spare plug complete all as per manufacturer's instruction complete including taking down existing unserviceable switch sockets of any type and size complete all as specified and directed.
S&F of flame proof LED light fitting 2X20 Watts, epoxy finish LM6 aluminium housing with heat resistant tubular glass cover held in two aluminium cups, with built-in control gear accessories, prewired including taking down existing unserviceable light fittings complete all as specified and directed.
S&F of flame proof bulk head flat type glass fittings, 30 Watts LED ceiling/wall mounted including taking down existing unserviceable bulk head fittings of any type and size complete all as specified and directed.
Taking out old unserviceable well glass light fitting and Supply and fixing flame proof well glass light fittings, 30 Watts LED ceiling/wall mounted including taking down existing unserviceable bulk head fittings of any type and size complete all as specified and directed.
M&L for rewinding of burnt out copper winding of flame proof ceiling fans of any make, size 1200 mm/1400mm sweep, rewinding with super enamelled copper wire of approved quality of existing gauge and size including necessary insulation with leathoroid sheet varnishing of winding of coil, packing, proper insulation, gasket etc including cleaning the rotor and the stator, overhauling, lubricating with fresh graese, etc and re-hanging the same and testing and commissioning, including taking out old unserviceable complete all as specified and directed.
All as per item No. 84.00 here-in-before but flame proof exhaust fan of 450mm size.
S&F of flame proof ceiling fan regulator etc. including taking down existing unserviceable ceiling fan regulator of any type and size complete all as specified and directed.
S&F of flame proof cast iron enclosure distribution board 415 volts, 4 way, TPN with ELCB and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoing and including making good to the disturbed surfaces of walls, floors etc.complete all as approved by CMRI Dhanbad with following incoming and outgoing controls including taking down existing unserviceable MCBs of any type and size all as specified and directed:- (i) Incoming:- ELCB 4 pole, 415 volts, 63 Amps - 01 No. (ii) Outgoing:- MCB 16 amps - 8 Nos.
S&F of flame proof cast iron enclosure main switch rotary Type 63 Amp 4 Pole, 415 Volt with all fixing arrangement and making good to the disturbed surfaces of walls, floors etc including taking down existing unserviceable main switches of any type and size complete all as specified and directed as approvedd by CMRI Dhanbad.
M&L for earthing connected with bldg main lightining arrestor etc with galvanised iron earth plate of size 600 x 600 x 6 mm thick burried directly in ground not less than 2.5 mtr below grond level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm connected by GI earth strip of size 32 x 6 mm thick soldered and revetted to earth plate attesters GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to the including flat iron clamp 25 x 3 mm including bolts, nuts and washers complete all as specified and directed. The earthing includes necessary excavation, PCC pit, CI cover with frame duly groted with PCC, watering pipe 20 mm bore, funnel with wire mess etc. all as specified and shown in electrical plate No 3 of SSR Part - I. Note : The unit rate shall also including earth work in any type of soil, PCC 1:3:6, type C1 for chamber, CI cover with frame duly grouted with PCC with locking system, funnel with GI watering pipe 20mm dia light grade, GI protection pipe light grade 40mm dia and wire mesh complete as directed by Engr-in-Charge.
Taking out old unserviceable tube rod and supply and fixing in replacement of LED tube rod 20 watt cap single side connection (for flame proof fitting) complete all as specified and directed.
All as per item No 90.00 here-in-before but double side connection.
M&L for test point terminal block made of gunmetal or phasphorus bronze of size 75x75x25mm drilled and srewed including 03 Nos 8mm dia 25mm long hexagonal head screwed including taking down unserviceable terminal block complete all as specified and directed.
Taking out old unserviceable cable from trenches of any size and credit to contractor complete all as specified and directed.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core including aluminium lugs at the termination ends complete all as specified and directed.
All as per item No. 94.00 here-in-before but 10 sqmm 2 core
All as per item No. 94.00 here-in-before but 16 sqmm 4 core
All as per item No. 94.00 here-in-before but 25 sqmm 3.5 core
All as per item No. 94.00 here-in-before but 35 sqmm 3.5 core
All as per item No. 94.00 here-in-before but 16 sqmm 2 core
All as per item No.94.00 here-in-before but 70 sqmm 3.5 core
All as per item No. 94.00 here-in-before but 95 sqmm 3.5 core
All as per item No. 94.00 here-in-before but 120 sqmm 3.5 core
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out complete all as specified and directed.
Returning filling in including spreading, leveling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed. Note:-Punned thickness only measured for payment.
Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
S&F of MCCB, 100 Amp, 3 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting, with thermal release range 80-100 Amp including spreader terminals and phase barriers complete all as specified and directed.
S&F of MCCB, 63 Amp, 3 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting, with thermal release range 80-100 Amp including spreader terminals and phase barriers complete all as specified and directed.
Taking out existing unserviceable street light control box and supply and fixing mild steel sheet 2mm thick control gear box for street security light of size not less than 250 (w) x 300(h) x 200(depth) mm, with aluminium bus bar of 32 Amps rating for single phase and neutral mounted on apoxy based insulators with locking arrangement fixed to pole with mild steel clamps -2 Nos of 20 mmx 4 mm and including MCB SP 6 Amps, B curve 230 volt- 01 No, complete all as specified and directed.
S&F in repairs analog time switch (FM series) complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 83715.00
HRK ENGINEERING CORPORATION
M/S RAKESH TRADERS
PRADEEP TIWARI CONTRACTOR
UMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .