| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹40.6 L+₹3.3 L (8.98%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹42.7 L+₹5.5 L (14.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹42.9 L+₹5.6 L (15.0%)Rejected-Finance A 4 TARINI APARTMENT PHASE I KILBURN COLONY HINOO DISTT RANCHI JHARKHAND 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹43.6 L+₹6.4 L (17.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | NU DOLPHIN ENTERPRISES L8 | RAJ KAMAL BUILDERS L2 | m/s. gopal krishan L1 | S S CONSTRUCTION COMPANY L7 | MAAN ENTERPRISES L10 | J S S BUILDERS & ENGINEERS L3 | TARSAM LAL SAINI CONTRACTOR L6 | Munish Kalia L5 | m/s inder construction co L9 | Sai Construction Co. L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any thickness from wall's/ceiling including raking out joints hacking for key scrubbing down with water and dispose off debries out side the premises where directed ; Complete all as specified and directed. | 1,350 | Square Metre | 1 ₹1,350 Lowest | 30 ₹40,500 | 70 ₹94,500 | 50 ₹67,500 | 15 ₹20,250 | 15 ₹20,250 | 40 ₹54,000 | 30 ₹40,500 | 30 ₹40,500 | 40 ₹54,000 |
| 2.00 | Material and Labour for 12 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, finsihed the surfaces even and smooth without using extra cement ; Complete all as specified and directed. | 1,000 | Square Metre | 122 ₹1,22,000 | 200 ₹2,00,000 | 100 ₹1,00,000 Lowest | 260 ₹2,60,000 | 210 ₹2,10,000 | 180 ₹1,80,000 | 215 ₹2,15,000 | 220 ₹2,20,000 | 230 ₹2,30,000 | 220 ₹2,20,000 |
| 3.00 | Material and Labour for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, finishing the surface fair and even with water proofing compound ; Complete all as specified and directed.(Water proofing compound will be measured and paid separately as supply only) | 150 | Square Metre | 123 ₹18,450 | 210 ₹31,500 | 100 ₹15,000 Lowest | 260 ₹39,000 | 225 ₹33,750 | 180 ₹27,000 | 240 ₹36,000 | 220 ₹33,000 | 245 ₹36,750 | 260 ₹39,000 |
| 4.00 | Material and Labour for 5mm thick rendering on concrete surfaces in cement mortar 1:3 , as in ceiling, finsihed the surfaces even and smooth without using extra cement ; Complete all as specified and directed. | 200 | Square Metre | 458 ₹91,600 | 200 ₹40,000 | 100 ₹20,000 Lowest | 295 ₹59,000 | 250 ₹50,000 | 160 ₹32,000 | 240 ₹48,000 | 230 ₹46,000 | 250 ₹50,000 | 220 ₹44,000 |
| 5.00 | Supply only integral water proofing compound confirming to IS-2645 ; Complete all as specified and directed. | 40.5 | Kilogram | 1 ₹40.5 Lowest | 75 ₹3,037.5 | 35 ₹1,417.5 | 50 ₹2,025 | 15 ₹607.5 | 550 ₹22,275 | 90 ₹3,645 | 50 ₹2,025 | 100 ₹4,050 | 50 ₹2,025 |
| 6.00 | Material and labour for damp proofing treatment to wall with two component acrylic polymer cementitious water proof elastomeric coating food grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joints of fibre mesh not be less than 10mm, then finally apply second layer mix by brush to entire surface of container covering 0.6-0.78 sqm/G at 1mm thickness in two coats depending on the level of substrate and curing it minimum 3 days ; Complete all as specified and directed.
Note : Quoted rate shall be deemed to be inclusive of all materials, labours, tools and plants, scaffolding and working upto height 6m etc. | 500 | Square Metre | 100 ₹50,000 Lowest | 600 ₹3,00,000 | 350 ₹1,75,000 | 600 ₹3,00,000 | 500 ₹2,50,000 | 550 ₹2,75,000 | 750 ₹3,75,000 | 900 ₹4,50,000 | 900 ₹4,50,000 | 550 ₹2,75,000 |
| 7.00 | Material and Labour for Preparing of new plastered surface and applying two coats cement base paints on walls ; Complete all as specified and directed. | 150 | Square Metre | 198 ₹29,700 | 35 ₹5,250 | 18 ₹2,700 Lowest | 60 ₹9,000 | 150 ₹22,500 | 40 ₹6,000 | 40 ₹6,000 | 30 ₹4,500 | 25 ₹3,750 | 60 ₹9,000 |
| 8.00 | Material and Labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over priming coat and 3mm wall care putty to make surface smooth ; Complete all as specified and directed. | 1,000 | Square Metre | 128 ₹1,28,000 | 55 ₹55,000 | 30 ₹30,000 Lowest | 50 ₹50,000 | 90 ₹90,000 | 35 ₹35,000 | 70 ₹70,000 | 40 ₹40,000 | 45 ₹45,000 | 50 ₹50,000 |
| 9.00 | Material and Labour for preparation of new plastered surfaces and applying two coats of white wash on ceiling ; Complete all as specified and directed. | 200 | Square Metre | 127 ₹25,400 | 15 ₹3,000 | 8 ₹1,600 Lowest | 15 ₹3,000 | 25 ₹5,000 | 30 ₹6,000 | 15 ₹3,000 | 10 ₹2,000 | 10 ₹2,000 | 10 ₹2,000 |
| 10.00 | Material and Labour for preparing old decorated plastered/unplastered wall surfaces including cornices by brooming down with steel wire brushes and scraping down smokes, spots etc applying one coat of oil bound distemper and fillinh holes etcwith wall care putty to make surface smooth ; Complete all as specified and directed. | 3,000 | Square Metre | 122 ₹3,66,000 | 20 ₹60,000 | 25 ₹75,000 | 35 ₹1,05,000 | 65 ₹1,95,000 | 55 ₹1,65,000 | 15 ₹45,000 Lowest | 50 ₹1,50,000 | 28 ₹84,000 | 50 ₹1,50,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
Garrison Engineer Amritsar Cantt PIN 143001
CERTAIN REPAIR TO MAP ACCN UNDER AGE B R II AT AMRITSAR CANTT
2025_MES_715606_1
GE/ASR-34/2025-26
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹98,000
1 Sept 2025
19 Jun 2025
18 Jul 2025
19 Jun 2025
11 Jul 2025
4 Jul 2025
20 Jun 2025 - 27 Jun 2025
Amount
Taking down cement plaster of any thickness from wall's/ceiling including raking out joints hacking for key scrubbing down with water and dispose off debries out side the premises where directed ; Complete all as specified and directed.
Material and Labour for 12 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, finsihed the surfaces even and smooth without using extra cement ; Complete all as specified and directed.
Material and Labour for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, finishing the surface fair and even with water proofing compound ; Complete all as specified and directed.(Water proofing compound will be measured and paid separately as supply only)
Material and Labour for 5mm thick rendering on concrete surfaces in cement mortar 1:3 , as in ceiling, finsihed the surfaces even and smooth without using extra cement ; Complete all as specified and directed.
Supply only integral water proofing compound confirming to IS-2645 ; Complete all as specified and directed.
Material and labour for damp proofing treatment to wall with two component acrylic polymer cementitious water proof elastomeric coating food grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joints of fibre mesh not be less than 10mm, then finally apply second layer mix by brush to entire surface of container covering 0.6-0.78 sqm/G at 1mm thickness in two coats depending on the level of substrate and curing it minimum 3 days ; Complete all as specified and directed. Note : Quoted rate shall be deemed to be inclusive of all materials, labours, tools and plants, scaffolding and working upto height 6m etc.
Material and Labour for Preparing of new plastered surface and applying two coats cement base paints on walls ; Complete all as specified and directed.
Material and Labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over priming coat and 3mm wall care putty to make surface smooth ; Complete all as specified and directed.
Material and Labour for preparation of new plastered surfaces and applying two coats of white wash on ceiling ; Complete all as specified and directed.
Material and Labour for preparing old decorated plastered/unplastered wall surfaces including cornices by brooming down with steel wire brushes and scraping down smokes, spots etc applying one coat of oil bound distemper and fillinh holes etcwith wall care putty to make surface smooth ; Complete all as specified and directed.
Material and Labour for preparation of old decorated brick/ concrete plastered or unplastered surfaces of walls, pillars, cornices by brooming down etc and applying one coat of white wash on walls, pillars, cornices etc over ; Complete all as specified and directed.
Material and Labour for preparation of old decorated brick/ concrete plastered or unplastered surfaces of ceiling by brooming down etc and applying one coat of white wash on ceiling, etc ; Complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level) ; Complete all as specified and directed.
Material and Labour for cement concrete type C-1, 1:3:6 ( using 20mm graded crushed stone aggregate) , 75 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair surface without using extra cement ; Complete all as specified and directed.
Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish debries out side the premises where directed ; Complete all as specified and directed.
Material and labour for water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:- (a) Application of two component acrylic modified cementitious coating on dried surface free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance existing coating and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer's literature should be strictly complied with including but not limited to the following:- (i) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr. Fixit 302 SBR latex/ perma latex SBR/ FOSROC Nitbond SBR latex/ Asian paint latex as required. Final cleaning of surface with powder grinder, wire brush, hair brush & vacuum pressure. (b) Dampen all surface immediately ahead of application of acrylic modified cementitious coating of SIKA top seal-107/ Brush bond FOSROC/ Dr. Fixit/ STP/ CICO. (c) Whilst the surface is still damp from saturation (SSD) apply one coat of acrylic modified cementitious coating of SIKA top seal-107/ Brush bond FOSROC/ Dr. Fixit/ STP/ whilst of the first coat is wet. (d) Apply glass fabric sheet of SIKA Fab 1/ FOSROC/ Dr. Fixit/ STP whilist the first coat is wet. (e) Once touch dry, apply second coat of acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr. Fixit/STP/CICO of viscosity as per manufacturer ins on the entire area. (f) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (g) The waterproofing coating should be taken to a height minimum 450mm above the finished floor level on the vertical surface. (h) It is essential to cure acrylic modified cementitious coating immediately after application (min 6-8 hrs drying) for a min of 3 to 5 days to ensure full cement hydration and to minimize cracking.
(j) A protection plaster (12-15mm thick) in cement mortar (1:3) admixed with appropriate integral water proofing compound has to be a applied on the walls. (k) Admixture: Sika plastocrete plus/ FOSROC/ Dr. Fixit/ STP/ CICO confirming to IS 2645. (l) Providing and applying a protection screed 50mm thick in cement mortar (1:4) mixed with SIKA plastocrete over the applied water proofing coating on horizontal surfaces. (m) Admixture: Sika plastocrete plus/ FOSROC/ Dr. Fixit/ STP/ CICO confirming to IS 2645. (n) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansion zone in the centre of make seal tape SIKA/ FOSROC/ Dr. Fixit/ STP. (o) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations. (p) Water proofing treatment has to be carried out through authorised applicators. (q) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealant. (r) All traps in sunken slabs to be enclosed with PCC (1:1½:3) (min 15cm) alround. (s) The sunken portion shall be filled with PCC (1:5:10) using 40mm graded crushed stone aggregate all as specified. (t) Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall (Approx 450 mm to 600mmlong) including cutting hole in existing wall and making good the disturbed surface ; Complete all as specified and directed. (u) Providing 25mm thick cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as sin flooring for laying floor finishes all as specified. Notes :- (i) Item No. (s) shall be measured and paid seperately. (ii) Plan area (wall to wall/ wall to beam/ beam to beam) shall be measured and paid. No separate measurement for vertical surface shall be accounted and quoted rate shall be deemed to include for the same.
Demolition of brick work built in cement mortar, seperation, cleaning and stacking of serviceable bricks for reuse and removal of debries out side the premises where directed ; Complete all as specified and directed.
Material and Labour for brick work with sub Class 'B' old size bricks, straight or curved on plan exceeding 6 Metre mean radius, built in cement mortar 1:6 ; Complete all as specified and directed.
All as per Srl item No.19 here-in-before but except Bricks.Note : (i) Serviceable bricks obtained from demolition shall be reused. ; Complete all as specified and directed.
Material and Labour for Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 ; Complete all as specified and directed.
Supply and Fixing in repair 15mm bib tap standard of PTMT any colour fancy type long body high pressure screwed for iron pipe and fixed (minimum weight 15 mm- 105 gms) etc ; Complete all as specified and directed.
Supply and Fixing in repair 15mm angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15 mm- 90 gms/20 mm-92 gms) ; Complete all as specified and directed.
Supply and Fixing in repair 15mm Pillar taps,of PTMT any colour fancy type high pressure scewed for iron pipe and fixed ; Complete all as specified and directed.
Supply and Fixing in repairs for Vitreous China wash basin, white, flat back, size 500 X 400mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete as in repairs ; Complete all as specified and directed.
Supply and Fixing in repairs for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete as in repairs ; Complete all as specified and directed.
Supply and Fixing in repairs vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe)including connection to trap, and to flushing pipe, anti-syphonage pipe etccomplete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demilition of PCC / Lime concrete bedding existing pan ; Complete all as specified and directed.
Supply and Fixing in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) front or back inlet including seat cover and connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc and making good to floor complete as in repairs ; Complete all as specified and directed.
Supply and Fixing in repairs vitreous china wash down water closet pedestral pattern pan (coupled closet) white including vitreous china flushing cystern, flush pipe, seat cover cystern cover ; Complete all as specified and directed.
Supply and Fixing in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm ; Complete all as specified and directed.
Supply and Fixing in repairs PVC waste pipe 32/38/40 mm dia, 600 to 750 mm long comlete ; Complete all as specified and directed.
Supply and fixing in repairs stainless steel plate rack of size 1m x 1m, with folded edge gloss finish fixed to wall ; Complete all as specified and directed.
Supply and Fixing in repairs PVC connections 15mm size with PTMT nuts of length 450mm. ; Complete all as specified and directed.
Supply and Fixing in repair 40mm waste fittings, brass, chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. ; Complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable rubbish off the premises ; Complete all as specified and directed.
Material and Labour for Non skid cerermic coloured tiles 7 to 8 mm thick (Square /rectangular) area of each tile exc. 0.11 sqm but n.exc. 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match over 20mm thick screed bed in cement mortar (1:6) ; Complete all as specified and directed.
All as per item No. 37 above but in skirting over 10mm thick cement screed in cement mortar 1:4 ; Complete all as specified and directed.
Material and Labour for Glazed ceramic coloured tiles in vertical surface 350x 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match such skriting /dado and over 10mm thick in cement mortar 1:4 as in backing plaster ; Complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar ; Complete all as specified and directed.
Material and Labour for granite slab (of any type) 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick screed bed of cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite. ; Complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe including necessary cuttins, chases and making good in cement mortat 1:3 ; Complete all as specified and directed.
Re-fixing for 15 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-running the old screw threads etc ; Complete all as specified and directed.
Supply and Fixing for 15mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) ; Complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe including necessary cuttins, chases and making good in cement mortat 1:3 ; Complete all as specified and directed.
Supply and Fixing for 20 mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) ; Complete all as specified and directed.
Re-fixing for 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-running the old screw threads etc ; Complete all as specified and directed.
Supply and Fixing in repair 500 Ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with manhole cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I ; Complete all as specified and directed.
Supply and Fixing in repair rotational moulded polythelene water storage tanks tripple layer( white colour) of capacity 1000 litres with and including 20mm dia float valve with brass fittings hoisted, fixed in position and making connection including dismantling of existing unserviceable tank ; Complete all as specified and directed.
Disconnecting existing tanks of cap exc 500 ltrs & n.exc 1000 Ltrs, setting aside (or lower ing if required) for repairs, cleaning, etc. and hoisting if required re- connecting and re-fixing in position and Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc ; Complete all as specified and directed.
Supply and Fixing in repairs 20 mm Ball valves high pressure of PTMT with epoxy coat ed Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0mm-210gms) ; Complete all as specified and directed.
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) nxc 1.50 sqm each ; Complete all as specified and directed.
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) exc 1.50 Sqm & nxc 4.00 Sqm each (as in doors) ; Complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but nexc 2 Sqm each ; Complete all as specified and directed.
Taking down and refixing same opening shutter exc.1 sqm and not exc 2 sqm each. ; Complete all as specified and directed.
Supply and Fixing factory made pressed steel frames 1.25mm thick for door size of frame 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and filling with PCC 1:2:4 type B-0; Complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in bed blocks for hold fast etc. including necessary form work ; Complete all as specified and directed.
Supply and Fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete FE -290 Gde E-165 ; Complete all as specified and directed.
Supply and fixing factory made PVC Internal door frame of size 100 mm x 45 mm with a wall thickness of 5 mm (+0.25) , made out of extruded 5 mm (+0.25) thick PVC sheet manufactured by asn ISO - 9001-2008 certified company, and by joining 3 Nos heat bent PVC sheet sections. The inside section of size 90 x 30mm shall be made from plain colour PVC sheet of 5 mm (+0.25) thickness. The inside section will be covered by sticking two sections of size 30 x 35 mm and 70 x 45 mm made from 5 mm (+0.25) thick plain PVC sheet. The frame shall be mitre cut at two corners and oined with 4 Nos of 150 mm long brackets of 15 mm x 15 mm square tube . The two vertical door frames are to be reinforced with 40mm x 20mm MS tube of 19 guage through out the frame . The door frame whslla be fixed to the wall using 8/100 mm long MS Screws through thee frame by using anchor fasteners. A minimum of 4 Nos of screws to be provided for each vertical member & minimum 2 Nos for horizontal member etc as per manufacturer's specification, ; Complete all as specified and directed.
Material and Labour for 30mm thick " FACTORY MADE DOOR SHUTTER - WOOD FREE consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 20mm x 40mm for stiles as well as top, bottoMaterial and Labourock rail. M.S frame shall have a coat of metal primer of approved make & manufacturer. The inside panel shall consist of 20mm thick multichamber hollow PVC section of 1 mm wall thickness, bonded using solvent cement / eynoacrylate adhesive with 5mm (+0.25) thick moulded PVC sheet of Density 600 Kg/Cbm Manufactured by an ISO-9001-2015 certified company with 2, 4, 6 raised panel design in plain/prelam colours after routing the moulded design on one side of the inside panel, 5mm (+0.25) plain/prelam PVC sheet to be pasted using solvent cement / cynoacrylate adensive on other side of the Hollow PVC section. All the four edge of the panel to be sealed with lipping of 10mm thick & 20mm wide PVC sheet baton (Made by sticking 02 Nos. foam PVC sheets of 5mm (+0.25) thickness using PVC solvent cement adhesive. Door edge lipping to be painted with PVC ink of matching colour of plain / prelam mouded PVC sheet of door. 20mm thick (5mm x 4 Nos) thick PVC sheet to be given for lock provision at lock height. Door to be fixed with frame with 3 nos. stainless steel but hinges of size 100mm *25mm*2mm and 50mm longsteel screws drilled suitable to pass through both the walls of M.S tube. other hardwares should be fixed with 25mm*8mm size steel screws etc, complete as per direction of Engineer-in-Charge, manufacturer's specification and drawing.
Supply and Fixing factory made 35 mm thick flush shutter, soild core construction, with block board core and plywood face panel commercial type on both sides ; Complete all as specified and directed.
Supply and Fixing framed work such as grill, framed guard bar and similer work conforming to FE 290, GDE E- 165 ; Complete all as specified and directed.
Hacking out old broken glass any thickness, size, quality or description from wooden frames or metal frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads ; Complete all as specified and directed.
Supply and Fixing 5.5mm thick ordinary sheet glass and glazing with EPDM / neoprene rubber packing, anodised aluminium snap beading, in squares not exc 0.50 Sqm in each panes ; Complete all as specified and directed.
Supply and Fixing 5.5mm thick ordinary sheet glass and glazing with EPDM / neoprene rubber packing, anodised aluminium snap beading, in squares exc 0.50 Sqm in each panes ; Complete all as specified and directed.
Supply and fixing 5.5mm thich figured glass pin head type and glazing with EPDM / neoprene rubber packing, anodised aluminium snap beading in squares not exc 0.50sqm in each pane ; Complete all as specified and directed.
Supply and Fixing 3mm thick ordinary sheet glass and glazing with oil putty or fixed on steel frame, in squares not exc 0.50 Sqm in each panes ; Complete all as specified and directed.
Supply and Fixing 150mm aluminum , anodised, barrel tower bolts of extruded section . ; Complete all as specified and directed.
Supply and Fixing butt hinges 100mm size medium weight cold rolled mild steel, fixed with screws or welded to steel frame ; Complete all as specified and directed.
Supply and Fixing 150 mm aluminum Handle Cast type ; Complete all as specified and directed.
Supply and Fixing 250mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed. ; Complete all as specified and directed.
Supply and Fixing M.S. 300mm ordinary rat tail rod pattern spring including roller and roller plate complete including necessary welding to door frame ; Complete all as specified and directed.
Material and Labour for preparation of new steel surface and applying two coat of synthetic enamel paint over one coat of red oxide primer on new surface ; Complete all as specified and directed.
Material and Labour for preparation of new wood surface over 10 cm girth or width and apply two coat synthetic enamel paint over a coat of pink primer ; Complete all as specified and directed.
Dismantling boarding,any description,fixed in any position with nails ; Complete all as specified and directed.
Dismantling fibre sheet as in wall cladding / shaft covering ; Complete all as specified and directed.
Material and labour for cup board shutter, frame made of angle iron 35x35x6mm, covered with 1.00mm thick MS sheet, welded to frame including suitable handle, lugs and locking arrangement ; Complete all as specified and directed.
Supply and Fixing Fibre glass reinforced translucent sheeting plain 2 mm to 3 mm thick of an colour having tensile strength of as in cladding to wall / Shaft covering etc fixed with self tapping screws ; Complete all as specified and directed.
Supply and Fixing solid PVC shutter 18mm thick with one side prelam of any shade plain colour as in cup board, kitchen cabinet shutter etc. ; Complete all as specified and directed.
Supply and Fixing PVC board 18mm thick, in cupboard shelves and backside (for hanging) kitchen cabinet etc ; Complete all as specified and directed.
Supply and Fixing 40 mm Continuous (piano) hinges, mild steel, bright finish or electro galvanised ; Complete all as specified and directed.
Supply and Fixing 75-80mm long stainless steel handle ; Complete all as specified and directed.
Supply and fixing, in repair 25mm dia MS pipe PVC sheathed, decorative fancy type, curtain rod including brackets & a set of ABS finials ; Complete all as specified and directed.
Dismantling of PVC pipe of 75/100mm dia fixed with cement joint ; Complete all as specified and directed.
Supply and Fixing in repairs110 mm bore PVC (SWR ) pipes single socketed, in any lenth with rubber ring fixed to wall. ; Complete all as specified and directed.
Supply and Fixing PVC (SWR) bend 110 mm size ; Complete all as specified and directed.
Supply and Fixing 110 mm bore PVC (SWR) single Tee ; Complete all as specified and directed.
Supply and Fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors ; Complete all as specified and directed.
Material and Labour for PVC (SWR) gully trap 125/110mm setting and jointing with solvent cement. ; Complete all as specified and directed.
Material and Labour for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement ; Complete all as specified and directed.
Supply and Fixing in repairs Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges ; Complete all as specified and directed.
Supply and Fixing 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor ; Complete all as specified and directed.
Supply and Fixing in repair 15 mm Bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe of 15mm bore and fixed in repairs, including extra CP nipple wherever required. ; Complete all as specified and directed.
Supply and Fixing in repairs for 15mm dia Stop valves, , high pressure, with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for unions,including extra CP nipple wherever required. complete as ; Complete all as specified and directed.
Supply and Fixing in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup (Concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions including extra CP nipple wherever required. ; Complete all as specified and directed.
Supply and Fixing in repairs Wall Mixture, chromium plated, ; Complete all as specified and directed.
Supply and Fixing in repairs Basin Mixture, Cromium plated, ; Complete all as specified and directed.
Supply and Fixing in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15mm dia steel pipe or union including extra CP nipple wherever required ; Complete all as specified and directed.
Supply and fixing in repair health faucet suitable 15mm dia fixed to GI tubing with CP lead ; Complete all as specified and directed.
Material and Labour for preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described for One coat of synthetic enamel paint ; Complete all as specified and directed.
Material and Labour for One coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth ; Complete all as specified and directed.
Supply and fixing Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. Including taking out old and removal ; Complete all as specified and directed.
Supply and fixing anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m includingnecessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including taking out existing and removal Complete all as specified and directed.
Supply and fixing Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) including taking out existing and removal old ; Complete all as specified and directed.
Supply and fixing in repairs aluminium door closer hydraulically regulated designation No 3 universal type suitable for door shutter of 861 to 1000 mm in width and of weight between 61 to 80 kg and fixed ; Complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power etc.) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. , removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) complete all as specified and directed.
Material and Labour for point wiring in existing concealed conduit for one light point/fan point/bell/buzzer point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existing PVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed. (Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for point wiring in existing concealed conduit for one three pin socket outlet 5 Amps independent board ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existing PVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed. (Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for point wiring in existing concealed conduit for one three pin 5 Amps socket outlet on the same board with other switches ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existing PVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.(Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for point wiring in existing concealed conduit for one light point controlled by two way switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existing PVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.(Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
All a per item No 107 here-in-above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper multi stranded conductor connecting to common earth dolly ; Complete all as specified and directed.
Material and Labour for surface point wiring for one light /fan/ bell/buzzer point controlled by one 5 Amp switch one way ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.(Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for surface point wiring for one three pin socket outlet 5 Amps independent board ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.(Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for surface point wiring for one three pin 5 Amps socket outlet on the same board with other switches ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.( Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
Material and Labour for surface point wiring for one light point controlled by two way switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar 1:3 Complete all as specified and directed.(Switch/socket/regulator/ceiling rose/lamp holder/bell etc. shall be measured and paid for separately)
All a per item No. 112 here-in-above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper solid conductor connecting to common earth dolly ; Complete all as specified and directed.
Supply and Fixing Modular switch flush type one way 6 Amp, 230 volts complete all as specified and directed.
Supply and Fixing Modular switch flush type two way 6 Amp, 230 volts complete all as specified and directed.
Supply and Fixing Modular socket 6 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and Fixing Modular switch flush type one way 16 Amp, 230 volts complete all as specified and directed
Supply and Fixing Modular socket 6 /16 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and Fixing Modular switch bell push swiwch 6 Amp 1 module complete all as specified and directed.
Supply and fixing ceiling rose 65X50 mm three terminals ; Complete all as specified and directed.
Supply and Fixing Lamp holder bakellite type with black plate suitable for batten fitting complete all as specified and directed.
Supply and fixing in repairs of Ding Dong bell AC 230 Volts ; Complete all as specified and directed.
Supply and Fixing Modular stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 volts ; Complete all as specified and directed.
Supply and Fixing in repairs for vertical sheet steel metal enclouser distribution boards, double door factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper wire of suitable size from the MCCB to the out going circuits one incoming MCCB and suitable outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories. (a) MCCB 100 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. ; Complete all as specified and directed.
Supply and fixing in repairs sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 8 ways including necess ; Complete all as specified and directed.complete all as specified.
Supply and fixing in repairs sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 12 ways including necessary brick work and plaster to match with the existing surface ; Complete all as specified and directed.
Supply and fixing in repairs MCB single pole 6 to 32 Amps ; Complete all as specified and directed.
Supply and fixing in repairs MCB DP 40 Amps 240V, 10 KA, ; Complete all as specified and directed.
Supply and fixing in repairs 40 to 63 Amps MCB TPN, 415 Volt ; Complete all as specified and directed.
Supply and Fixing in repairs of Sheet metal single pole and neutral enclosure, 240 volts with a two pin and earth plug and socket complete with one single pole MCB capacity 20 amps ; Complete all as specified and directed. (for AC and geyser).
Supply and Fixing in repairs ,Fresh Air fan of size 250mm, Plastic body 1200RPM, electrically driven, 230volts, 50Hz, single phase, AC supply,copper winding dynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3' long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to fan ; Complete all as specified and directed. Note: Making suitable opening for fixing air fan as required shall be deemed included in the quoted rate of item.
Supply and Fixing in repairs Exhaust fan of size 300mm, Heavy duty 1200RPM, electrically driven, 240volts, 50Hz, single phase, AC supply,copper winding dynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3' long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to exhaust fan for giving connection ; Complete all as specified and directed.. Note: Making suitable opening for fixing exhaust fan as required shall be deemed included in the quoted rate of item. NOTE FOR ITEM NO. 134 & 135 ;Old retrieved material shal be deposited in store yard of AGE EM.
Supply and Fixing in repairs LED tube light 20 watt, (4' long), 6500K, wall mounted, E-lite LED curve with high lumen batten with efficacy not less than of 100 lumens, with integrated electronic driver complete with all accessories ; Complete all as specified and directed.
Supply and fixing in repairs LED street light fitting powder coated pressure die cast alminium compact High power LED street light with heat resistant toughened glass for 25 watt with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device bracket made out of GI Pipe 40mm medium grade 1.2 mtr long made to shape with fixing clamps of MS Flat 40x6mm nuts bolts Complete all as specified and directed.
Supply and Fixing in repairs 1100 volts grade heavy duty PVC cable insulated aluminium conductor served with inner sheating of PVC tape and over all PVCsheathed in service connection stranded conductor flatr 6 sqmm 2 core cable ; Complete all as specified and directed.
Supply and Fixing in repairs, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in existing non metalic PVC rigid conduit medium grade of suitable size with all standared fitting , including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , ; Complete all as specified and directed. Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cable shall be measured as one unit/ one running meter.
Supply and Fixing in repairs, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting , on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , ; Complete all as specified and directed. Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cable & conduit shall be measured as one unit/ one running meter.
Supply and Fixing in repairs, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor on surface FRLS PVC insulated and unsheathed cable drawn in existing non metalic PVC rigid conduit medium grade of suitable size with all standared fitting , including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , ; Complete all as specified and directed. Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable shall be measured as one unit/ one running meter.
Supply and Fixing in repairs, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting , on surface , including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , ; Complete all as specified and directed. Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable & conduit shall be measured as one unit/ one running meter.
Material and Labour in repair for Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover Complete all as specified and directed . The cost of the watering pipe, bends, elbows etc. shall be deemed included in the qouted unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
RAJ KAMAL BUILDERS (BID ID -3354711)
J S S BUILDERS & ENGINEERS (BID ID -3355393)
Sai Construction Co. (BID ID -3355241)
Munish Kalia (BID ID -3355392)
TARSAM LAL SAINI CONTRACTOR (BID ID -3355680)
S S CONSTRUCTION COMPANY (BID ID -3355247)
NU DOLPHIN ENTERPRISES (BID ID -3352427)
m/s inder construction co (BID ID -3355152)
MAAN ENTERPRISES (BID ID -3355271)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .