Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.2 L+₹74,675 (4.83%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹16.7 L+₹1.2 L (8.05%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹17.2 L+₹1.7 L (11.2%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹18.0 L+₹2.5 L (16.0%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
25 Mar 2020, 6:00 pmClosed
GE(S) Jaipur
GE(S) Jaipur, MES, Kalyan Marg, Bani park, Jaipur-302006
REPAIR/MAINT OF STREET LIGHT AT ZONE- I AND ZONE II AREA AT JAIPUR MIL STN UNDER GE(S) JAIPUR
2020_MES_329751_1
GE (S)J-61P/2019-20 8552/ /E8
Open Tender
Civil Works
Item Rate
270 days
GE(S) Jaipur
Category E b(i)
9 documents required · 9 mandatory
₹500
Yes
GE(S) Jaipur
₹48,000
Yes
30 Mar 2020
28 Feb 2020
27 Mar 2020
28 Feb 2020
25 Mar 2020
13 Mar 2020
28 Feb 2020 - 6 Mar 2020
Amount
Supply and fixing in replacement of New Generation Energy Saving 150W LED flood light powder coated PDC aluminium housing with toughened glass cover with secondry lens Efficacy >100Lm/w. Available in 5700 K C&S, cat No ORION-3./150W LTEF150WHPLED, Crompton Greaves, Philips, wipro , Bajaj including taking down U/s light fitting complete. Zone-I area - 25 Zone-II area- 16
Supply and fixing in replacement of 100 W LED flood light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughened glass cover with secondry lens Efficacy >100Lm/w in 5700 K operating voltage range 170-275 Volt as directed by Engineer-in-charge including taking out old U/S flood light fitting of any type/size. Make: C&S,cat No ORION-3./100W LTEF100WHPLED, Crompton Greaves, Philips/Wipro, Bajaj Zone-I area - 15 Zone-II area- 12
Supply and fixing in replacement of 80 W LED flood light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughened glass cover with secondry lens Efficacy >100Lm/w in 5700 K operating voltage range 170-275 Volt as directed by engineer-in-charge including taking out old U/S flood light fitting of any type/size. Make: C&S,cat No ORION-3./80W LTEF80WHPLED, Crompton Greaves, Philips/Wipro, Bajaj Zone-I area - 15 Zone-II area- 10
Supply and fixing in replacement of 60 W LED flood light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughened glass cover with secondry lens Efficacy >100Lm/w in 5700 K, operating voltage range 170-275 Volt as directed by engineer-in-charge including taking out old U/S flood light fitting of any type/size. Make: C&S,cat No ORION-3./60W LTEF60WHPLED, Crompton Greaves, Philips/Wipro, Bajaj Zone-I area - 12 Zone-II area- 08
Labour only for repair of U/S time switch assymbly by replacing spares including reconnecting and testing complete Note : - Accessories/ spare parts shall be measured & paid separately under respective items of Sch `A`. Zone-I area - 15 Zone-II area- 12
Supply only following accessories/ spares parts :-
Contactors 4 pole 63 Amp (Make :- L&T MCX12 CS97014 Zone-I area - 12 Zone-II area- 12
Contactors 2 pole 40 Amp (Make :- L&T MNX40-2P CS90242 Zone-I area - 12 Zone-II area- 12
Time switch Astro type Zone-I area - 12 Zone-II area- 12
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor following size including taking down old U/S cable :-
6 sq. mm 2 core Zone-I area - 600 Zone-II area- 500
10 sq. mm 2 core Zone-I area - 400 Zone-II area- 350
Supply and fixing in replacement of PVC sheathed multi stranded copper conductor cable of following sizes
1.5 sq. mm 3 core Zone-I area - 200 Zone-II area- 400
2.5 sq. mm 3 core Zone-I area - 500 Zone-II area- 400
4 sq. mm 3 core Zone-I area - 400 Zone-II area- 300
M&L for Disconnecting and Taking down U/S Street light fitting of any type/rating from pole or wall dismantling the same for necessary repair or replacement of U/S spares complete and refixing, connecting and testing the same all as specied and directed by Engr-in_Charge. Note : - Accessories/ spare parts shall be measured & paid separatley under respective items of BOQ. Zone-I area - 450 Zone-II area- 350
Supply only LED Driver suitable for 45 to 60 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 150 Zone-II area- 100
Supply only LED Driver suitable for70 to 80 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 150 Zone-II area- 80
Supply only LED Driver suitable for 90 to 100 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 100 Zone-II area- 150
Supply only surge arrestor of 5 KV suitable for 45 to 60 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 150 Zone-II area- 80
Supply only surge arrestor of 5 KV suitable for 70/ 80 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 150 Zone-II area- 100
Supply only surge arrestor of 5 KV suitable for 90 to 100 watt LED light complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips Zone-I area - 100 Zone-II area- 100
S & F in replacement of thermoplastic, polystyrene unbreakable junction box size 300 x 200 x105 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamps & nuts, bolts, washers and including terminal block heavy duty with phase seperators between R, Y, B terminals, one MCB SP 6 amp 10 KA, all duly fixed on din channel, cable glands for cable entry. Make : Hensel Cat Part No K9350 or eqvt in SINTEX / EQVT Zone-I area - 50 Zone-II area- 60
Supply and fixing Automatic street light control switch using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be enclosed in a pole/wall mounted rust proof , Electric based on Nature light LUx* levei. Required illuminance level or switching ON is < 30 lux and for switching OFF > 10 lux. The sensor should also have part night operation facility of min. 4 hrs . to max . 12 hrs. The sensor along with suitable power contactor(s) and incoming -Out going MCBs should be enclosed in apole/wall mountable rust proof, electric shock proof,Termite proof and FR grade SMC Enclosure conforming IP 54. available as SWADEEP-02EC 8 KW 3 Phase,32 amp per phase. The circuit should also have provision for Manual Operation (i.e.Sensor By-Pass Option) three phase and neutral, 240 volts, 50 Hz, AC supply system (Make - Nature switch, Kakatiya cat/Model No 02EC-8KW3P . Zone-I area - 02 Zone-II area- 03
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation or for laying of cable etc and getting out in soft/loose soil. Zone-I area - 118 Zone-II area- 77
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth. Zone-I area - 79 Zone-II area- 50
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point Zone-I area - 43 Zone-II area- 27
M & L Sand cushioning to PVC under ground cable with tibba sand and punning to provide a required cover. Zone-I area - 35 Zone-II area- 23
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed by Engineer-in-Charge. Zone-I area - 3.8 Zone-II area- 2.3
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc including taking down of following size :-
16 Sqmm, 4 Core cable Zone-I area - 650 Zone-II area- 320
10 Sqmm, 2 Core cable Zone-II area- 450
Taking out existing LT cable of any size and type, not more than 20 Mtr length from the loop trench and relaying the same after dressing of cable including replacment of aluminium lugs, nuts etc complete including necessary excavation & earth work complete all as specified and directed by Engineer-in-Charge. Zone-I area - 10 Zone-II area- 12
M/S Anil Enterprises
SHREE BHAGWATI ENTERPRISES
Lakshmi Enterprises
M/S Sheeba Enterprises
LAKSHMI ASSOCIATES
DIVYA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .