Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | Admitted-Finance |
| 2 | Admitted-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 3 | Admitted-Finance D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | Admitted-Finance |
| 4 | Admitted-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | Admitted-Finance |
| 5 | Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Sept 2024, 6:00 pmClosed
GE (South West)
GE (South West) New Delhi-03
REPAIR/ MAINT OF LT PANEL/ ACB AND CONNECTED LT EQUIPMENTS, STREET LIGHT AND FLOOD LIGHT FITTINGS AND CONNECTED WORKS AT NBC (RESTRICTED AREA) UNDER GE (SOUTH WEST) NEW DELHI-03
2024_MES_670799_1
GE/SW-46/2024-25
Limited
Electrical and Maintenance Works
Item Rate
270 days
GE (South West) New Delhi
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹90,000
Yes
26 Sept 2024
3 Sept 2024
26 Sept 2024
3 Sept 2024
24 Sept 2024
17 Sept 2024
Amount
Supply and laying/ fixing/ passing through pipe of LT XLPE insulated, armoured electric power cable (heavy duty), aluminium stranded conductor, 1100 volts grade of cross sectional area 25 Sq mm, 3.5 core with suitable size cable glands, crimping type cables lugs, etc. laid in trenches or on floor/ wall/ poles or through pipe complete all as specified and as directed. (Note: Necessary Earth work or cable tray where ever required shall have deemed to be included in quoted rate.)
All as per Srl No 1.00 above but size of cable 50 Sqmm x 3.5 core.
All as per Srl No 1.00 above but size of cable 95 Sqmm x 3.5 core.
All as per Srl No 1.00 above but size of cable 120 Sqmm x 3.5 core.
All as per Srl No 1.00 above but size of cable 185 Sqmm x 3.5 core.
All as per Srl No 1.00 above but size of cable 300 Sqmm x 3.5 core.
All as per Srl No 1.00 above but size of cable 400 Sqmm x 3.5 core.
M&L Cable jointing kit for 1100 Volt (Earthed) grade cable for straight through joint heat shrink type (out door) complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm all as specified and directed.
All as per Srl No 8.00 but size 50 sqmm to 95 sqmm.
All as per Srl No 8.00 but size 120 sqmm to 185 sqmm.
All as per Srl No 8.00 but size 240 sqmm to 400 sqmm.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried dirctly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip.
Disconnecting the existing unservicable /burnt MCCB from the LT panel/ stand by DG set panel & Supply & fixing new MCCB, TP, 630 Amp, 50 KA,415 volt,50 Hz, 3 phase,Ics=100% of Icu with thermal magenatic release, installation of MCCB and connecting with existing cable including nut, bolt and washer etc complete all as specified & directed.
All as Srl item No 14.00 here in before but of size 630 Amp, FP, 36 KA
All as Srl item No 14.00 here in before but of size 500 Amp, TP, 36 KA
All as Srl item No 14.00 here in before but of size 400 Amp, TP, 36 KA
All as Srl item No 14.00 here in before but of size 350 Amp, TP, 36 KA
All as Srl item No 14.00 here in before but of size 200 Amp, TP, 36 KA
All as Srl item No 14.00 here in before but of size 125 Amp, TP, 16 KA.
All as Srl item No 14.00 here in before but of size 63 Amp, TP, 16 KA.
All as Srl item No 14.00 here in before but of size 100 Amp, 4 pole, 16 KA.
All as Srl item No 14.00 here in before but of size 40-100 Amp, TPN, 10 KA.
S&F in replacement of MCB SP 6-32 Amp, C-curve, 10 KA complete all as specified & directed.
S&F in replacement of MCB SPN 32 Amp, C-curve, 10 KA complete all as specified & directed.
S&F in replacement of MCB SPN 40-63 Amp, C-curve, 10 KA complete all as specified & directed.
Disconnecting the existing unservicable /burnt RCCB from the electrical panel and S&F in replacement of RCCB, FP, 63-100 Amp, 30mA leakage, complete all as specified and as directed.
Disconnecting the existing unservicable /burnt Isolator from the electrical panel and S&F in replacement of Isolator, FP, 100 Amp of existing size complete all as specified & directed.
S&F in replacement insulating mat 2m x 1m x 2.5mm thick suitable for LT electrical installation complete all as specified & directed.
S&F in repair power contactor, 70 Amps (MNX-70) , AC 3 duty, with add on block (2 NO+2NC), complete all as specified and as directed.
All as per item No. 32.00 here-in-before but of size 40 Amps (MNX-40).
All as per item No. 32.00 here-in-before but of size 32 Amps (MNX-32).
All as per item No. 32.00 here-in-before but of size 18 Amps (MNX-18).
S&F in replacement Auxillary contactor (2 NO+2NC), suitable for 18-80 Amps power contactors, complete all as specified and as directed.
S&F in replacement three pole power contactors of capacity ML-1.5 including control wiring, thimbles, etc complete all as specified and as directed.
All as per item No. 37.00 here in before but ML-3 type.
All as per item No. 37.00 here in before but of size ML-4 type.
Preparation of old painted surface cleaning of any type of panel and painting with two coat of synthetic super enamelled off white (existing at site) spray paints including servicing and cleaning and tightening of all internal components like contactors, ACBs, MCCBS, relays, eletrical wiring etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ACB, 4 Pole 1600 Amps 415V with thermal magnetic release drawout type, including dismentling & taking out old unserviceable ACB from panels & fabrication works to bus bar for proper fittings of ACB complete all as specified & directed.
Disconnecting all electrical and mechanical connections of Air Circit Breaker (ACB) of capacity 800 to 3200 Amp, fixed or drawout type, three/ four pole. Make:C&S/ABB/Schnieder/GE/L&T. Shifting the faulty ACB or connecting parts to the contractors workshop for certain required repairs. Refixing the repaired/replaced parts in its original position and tested under supervision of site-in-charge/ Engr-in-Charge complete all as specified and as directed. Note:- (i) Required Spare parts to be replaced during overhauling/ servicing shall be measured and paid seperatly as 'Supply only' under relevent items. (ii) Transportation charge & labour charges for taking down old spares and fixing of new spares shall deemed to be included in quoted rate.
Supply only the following spare parts for the ACB. Make : As per existing make and model.
Pole Assy drawout type suitable for any capacity/ type of ACB
Jaw contact Assy suitable for any capacity/ type of ACB
Arc chute suitable for any capacity/ type of ACB
Safety shutter suitable for any capacity/ type of ACB
Fixed arcing contact suitable for any capacity/ type of ACB
Moving arcing contact suitable for any capacity/ type of ACB
Cradle terminal assy suitable for any capacity/ type of ACB
Shunt Release suitable for any capacity of ACB
Under Voltage Release suitable for any capacity/ type of ACB
Closing Coil including resistor and connected hardware
Earth fault release any type suitable for any capacity of ACB
FRCD (Free return charging device) assy suitable for any capacity/ type of ACB
Main Spring suitable for any type/ capacity of ACB
Motor assy with limit switch and connected hardware suitable for any capacity/ type of ACB
Lockable Trip-push Button kit suitable for any capacity/ type of ACB
Racking-interlock suitable for any capacity/ type of ACB
Door Interlock
Racking Padlock Assembly suitable for any capacity/ type of ACB
Spring kit suitable for any capacity/ type of ACB
Roller Assy suitable for any capacity/ type of ACB
push button (red/green)
Racking Handle suitable for any capacity/ type of ACB
Operating Handle
Trip rod/ latch assy suitable for any capacity/ type of ACB
Servicing of any type (Oil/ Dry) type of the transformer of capacity 1600 KVA, opening top cover, and carrying out the following work complete all as specified and directed:- (a) Dismantling of all attachment viz breather assembly, conservator, oil temperature gauge, HT/LT bushing etc. check thier serviceability and keeping aside for reuse in oil type transformer. (b) Cleaning of complete transformer tank oil fins (in case of oil type), removing of sludge, and making the inside surface of tank dry by blowing of hot air as directed and specified. (c) Removing old paint and painting of transformer of capacity 1600 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer and painting of inside surface with heat resistant paint (hot oil proof) complete all as specified and directed. (d) Reconnecting all the component of transformer after checking their serviceability and perform the required tests in presence of Engr-in-Charge.
Note-(i) (a) Transformer must be meggred and connecting all connection and necessary testing complete with including under mentioned scope of work. (b) Cleaning of transformer from inside. (c) Testing the Transformer for IR Values (d) Checking/servicing/calibration of WTI for healthiness.(e) Magnetic Balance Test (f) IR Value check before and after the work.(g) Voltage Ratio Test at 440 V. (h) Phase sequence test (j) Commissioning of transformer after completion of work. (ii) Maintenance/repair shall be carried out by OEM/ authorised dealer. (iii)Test results obtained shall be recorded and produced to the Engr-in-Charge. (iv)All Measuring equipments and T&P required shall be arranged by the contractor. (v)Any item/activity not listed/covered here above and required during completing the work will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. (vii) The rate quoted shall be deemed to include for disconnection of Transformer HV/LV terminations for testing work and re-connections after completion of repair work. (viii) Defective part measured and paid under respective item as supply only. However fixing charges shall deemed to be included in this item.
Supply only in replacement Thermometer/ heat sensor of transformer upto capacity 1600 KVA complete all as specified and directed.
M&L for dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note:- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed.
M&L for attending major break downs on LT lines, UG cables or bus risers including, replacement of insulators/ conductors/ crrossarms & laying of temporary cables etc. Note: (i) The contractor shall immediatly attend break down on short notice as & when required with T&P and transport on receipt of information in required to breakdown on the direction of Engr-in-Charge. (ii) In case contractor fails to attend and rectify the fault in 24 hr after intimation by department, he shall be liable to bear the recovery @ Rs 1000 /- per hour after intimation of 24 hrs and department shall rectify the fault through other agency on contractor risk and cost and double amount should be recovered from contractor dues.
S&F in replacement indicator lamp assembly for RYB phase suitable for 110V/ 230V as per existing make and model complete all as specified and as directed.
S&F in replacement SS panel door lock with suitable key as per existing make and model complete all as specified and as directed.
M&L for disconnecting all electrical LT cables and taking down the old existing unserviceable Feeder LT Panel of any size and model including all accessories at NBC (basement) and supply, installation, testing and commissioning in repairs of feeder LT panel indoor type (size not less than 1800mm x 1500mm x 600mm) floor mounted of factory made powder coated made out of outside body not less than 2mm thick steel sheet and inside body 14 gauge steel sheet, housing cubicle type, free standing LT panel suitable for 440V 3-phase. 50 Hz. AC supply. It shall be extendible at both ends, fully compartmentalised locking arrangement, front side opening arrangement of suitable size, incl mounted on angle iron stand of size 50x50x6mm having minimum height one feet duly grouted or welded on floor or make a foundation as per direction of Engr-in-Charge. Copper bus bar of capacity 630 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators with heat shrinkable sleeve bearing short circuit current to withstand minimum 50 kA for one second for MCCB to all feeders to accommodate following items and providing danger notice plate of size 300 x 200mm x 3mm thick duly marked skull & bones with night glow highlighter fluorescent paint complete:-
(a) Incomer :- MCCB TP 500 Amp 36 KA-01 No. (b) Outgoing :- MCCB TP 63 amp 16 KA -03 Nos MCCB TP 125 amp 16 KA- 03 Nos (c) RYB (each set) LED indicator for each incoming & outgoing supplies. (d) Digital Voltmeter - 01 No (e) Digital ammeter with CTs - 07 Nos (f) Termination of all cables with suitable size thimble and gland-1 Job (g) Fully Automatic star delta motor starter 15 hp, with single phase protection, timer, star-delta, relay AC-3, 415V,50 Hz, 3 Phase, push button (Red & Green), LED Indicator (Red + Green), CTs and contactors with suitable relay range.- 02 Nos (h) phase sequence corrector
All specification as per item No. 51 but LT panel indoor type (size not less than 1800mm x 1200mm x 600mm). (a) Incomer :- MCCB TP 400 Amp 36 KA-01 no (b) Outgoing :-MCCB TP 63 amp 16 KA -04 nos MCCB TP 125 amp 16 KA- 01 nos (c) RYB (each set) LED indicator for each incoming & outgoing supplies. (d) Digital Voltmeter - 01 no (e) Digital ammeter with CTs - 06 nos (f) Termination of all cables with suitable size thimble and gland-1 job (g) Fully Automatic star delta motor starter for 5 hp, with single phase protection , timer, star-delta, relay AC-3, 415V,50 Hz, 3 Phase, push button (Red & Green), LED Indicator (Red + Green), CTs and contactors with suitable relay range.- 02 nos (h) phase sequence corrector
M&L for disconnecting all electrical LT cables and taking down the old existing unserviceable Feeder Panel of any size and model including all accessories at NBC (basement) and supply, installation, testing and commissioning in repairs of feeder panel indoor type (size not less than 1800mm x 900mm x 600mm) floor mounted of factory made powder coated made out of outside body not less than 2mm thick steel sheet and inside body 14 gauge steel sheet, housing cubicle type, free standing feeder panel suitable for 440V 3-phase. 50 Hz. AC supply. It shall be extendible at both ends, fully compartmentalised locking arrangement, front side opening arrangement of suitable size, incl mounted on angle iron stand of size 50x50x6mm having minimum height one feet duly grouted or welded on floor or make a foundation as per direction of engr-in-charge. Aluminium bus bar of capacity 400 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators with heat shrinkable sleeve bearing short circuit current to withstand minimum 50 kA for one second for MCCB to all feeders to accommodate following items and providing danger notice plate of size 300 x 200mm x 3mm thick duly marked skull & bones with night glow highlighter fluorescent paint complete. (a) Incomer :- MCCB TP 350 Amp 36 KA-01 no (b) Outgoing :- MCCB TP 63 amp 16 KA -06 nos (c) RYB (each set) LED indicator for each incoming & outgoing supplies. (d) Digital Voltmeter - 01 no (e) Digital ammeter with CTs - 07 nos (f) Termination of all cables with suitable size thimble and gland-1 job
M&L for disconnecting all electrical LT cables and taking down the old existing unserviceable Feeder Panel of any size and model including all accessories at NBC (Terrace) and supply, installation, testing and commissioning in repairs of LT Feeder panel enclosure outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof enclosure (size not less than 2000mm x 1800mm x1000mm(W x H x D)) made out of 3.15mm thick CRCA sheet, factory made (CPRI approved manufacturer) powder coated painted as approved colour, copper bus bar suitable for 3 phase 4 wire suitable for 440 Volts 3-phase, 50 Hz, AC supply. It shall be extendible at both ends, fully compartmentalised locking arrangement, front and rear side opening arrangement of suitable size, incl mounted on angle iron stand of size 50x50x6mm having minimum height one feet duly grouted or welded on floor or PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to in and including accomodate the following items and all as specified and directed by Engr-in-Charge. Copper bus bar of capacity 2000 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators with heat shrinkable sleeve bearing short circuit current to withstand minimum 50 kA and providing danger notice plate of size 300 x 200mm x 3mm thick duly marked skull & bones with night glow highlighter fluorescent paint complete:-
(a) Incomer :- ACB TP 1600 Amp 50 KA-01 no (b) Outgoing :- MCCB TP 630 amp 36 KA -08 nos (c) RYB (each set) LED indicator for each incoming & outgoing supplies. (d) Digital Voltmeter - 01 no (e) Digital ammeter with CTs - 09 nos (f) Termination of all cables with suitable size thimble and gland-1 job Note: All existing accessories (a) & (b) mentioned in item no 54 to be fixed in the LT feeder Panel enclosure and item mentioned in (c), (d) & (e) shall be measured and paid separately under relevant items of this schedule. Contractor should visit the site before participating in bidding.
Note for item no 51 to 54:- (i) Contractor will be taken up approval of Accepting Officer/ Engr-in-charge for panel drawings before fabrication of Panel. (ii) Foundation & PCC work of LT panel will be executed PCC (1:2:4) type B-1 as per site requirement and cost deemed included in quoted unit rate. (iii) Price of required cable tray and connected items shall be included in the quoted rate with no extra cost to the department. Contractors are advised to visit the site before quoting the rate.
Disconnecting all electrical and mechanical connections of APFC panel of any type and capacity, cleaning of APFC panel with blower and checking the faulty parts and refixing the repaired/replaced parts in its original position and tested under supervision of site-in-charge/ Engr-in-Charge complete all as specified and as directed. Note:- (i) Required Spare parts to be replaced during overhauling/servicing shall be measured and paid seperatly as 'Supply only' under relevent items. (ii) Transportation charge & labour charges for taking down old spares and fixing of new spares shall deemed to be included in quoted rate.
Supply only capacitor of 15 KVAR capacity having specification : epcos power capacitor, phicap, temp cat-10D, connection- delta, rated current 32-80 amp, 440V, 3 ph, 50 hz, Ins level-3kV, dielectric MPPSH, impregnent MPCB, 75mm x 270mm (d x h), cat part no B32344N4152A40 complete all as specified and as directed.
All as per item No. 57.00 here-in-before but of size 25 KVAR, 90mm x 270mm (d x h), cat part no B32344N4252A40 complete all as specified and as directed.
Supply only resistors (resistor E as discharge device) suitable for 15/25KVAR capacitor complete all as specified and as directed.
Supply only Auxiliary contactors or capacitor duty contactors suitable for 15KVAR capacitors complete all as specified and as directed.
All as per item No. 60.00 here-in-before but for size of 25 KVAR complete all as specified and as directed.
Supply only push button of existing make and model complete all as specified and as directed. Note for item no 57 to 62 : Fixing charges of material of item no 57 to 62 is included in the quoted rate with no extra cost to the department.
S&F in replacement plug-in-box enclosure with interlocking with bustrunking size not less than 410 x 204 x 124 (L x W x D), plug in contacts made out of silver plated copper with spring steel backup pressure clips, suitable for mccb with fuses provision of cap 63-to 125 Amps of existing make and model complete all as specified and as directed.
All as per item No. 64.00 here-in-before, size not less than 430 x 250 x 200 mm but suitable for mccb of cap 160 to 250 Amps.
All as per item No. 64.00 here-in-before, size not less than 600 x 400 x 250 mm but suitable for mccb of cap 315 to 630 Amps.
S&F in replacement of star- delta starter with connected accessories for 15 hp, 3 Phase, 415V complete all as specified & as directed.
All as per item No. 67.00 here-in-before but for 10 HP, 3 ph, 415V.
All as per item No. 67.00 here-in-before but for 7.5 HP, 3 ph, 415V.
M&L for disconnecting all electrical connections, supply and fixing new 630A phase sequence corrector with enclosure (with powder coated paint) with all connected accessories suitable for 300 kva, 415V, 50 Hz ups and refixing the above complete all as specified and as directed.
All as per item no 70 here-in-before but 100A Phase sequence corrector panel with connected accessories suitable for 15 kva, 415V, 50 Hz ups complete all as specified and as directed.
All as per item no 70 here-in-before but 63A Phase sequence corrector panel with connected accessories suitable for 10 kva, 415V, 50 Hz ups complete all as specified and as directed.
M&L for disconnecting all electrical connections, supply and fixing in replacement of static switch module 63 to 125 amp with all connected accessories, 415V, 3 ph, 50Hz and reconnecting all electrical connections complete all as specified and as directed.
S&F in replacement distribution box 4 way, AC, TP & neutral metal enclosure, Glazed single dooor, 415 V, AC, IP-43, surface or concealed type with suitable bus bar, neutral link, earth link suitable for MCCB 63-125 Amps as incomer and MCB SP as out going completeand making good disturbed surface all as directed.
M&L for cleaning of bus trunking system and checking their loose connections and perform visual & test inspection by Engineer of OEM i.e. M/s C&S/ schnieder as per existing make available at site or their authorised dealer in presence of Engr-in-Charge and provide a fitness report complete all as specified and as directed. i) Trunking alignment ii) Support spaced as recommended by manufacturer iii) Tap-off unit & component check iv) Joint alignment & tightening torque v) Phase check vi) Continuity test vii) Insulation resistance test
S&F in replacement of current transformer (CT) of capacity 3000/5A, cast resin or tape wound type with burden 15 VA, 5P10, accuracy class 1 suitable for panel mounting complete all as specified and as directed.
All as per item no 76 here-in-before but capacity 2500/5A.
All as per item no 76 here-in-before but capacity 1600/5A.
All as per item no 76 here-in-before but capacity 600/5A.
All as per item no 76 here-in-before but capacity 400/5A.
All as per item no 76 here-in-before but capacity 250/5A.
All as per item no 76 here-in-before but capacity 100/5A.
All as per item no 76 here-in-before but capacity 63/5A.
S&F in replacement energy efficient street light of 180 watt with elctronic driver (built-in, potted electronic LED driver (SMPS based constant current supply) with lower THD, output open circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13) having tempered protective cover, operating voltage 140V-170V, mercury free, UV/IR radiation free, lumen efficacy of LED >140 lm/W with PC lens to ensure better uniformity of light distribution, IP-66 complete all as specified and as directed.
Supply and fix PVC (thermo plastic) street light junction box heavy duty with locking arrangement 3 phase aluminium bus bar incl 02 Nos PVC conduit upto the height of top most level of coping of pole from GL alongwith necessary MS clamp nut bolts and washers for fixing and 01 No MCB single pole 240 V 6-32 Amps complete including taking down old one complete all as specified and directed. (Make:- Sintex /Hensel)
M&L for preparation of old painted steel surfaces upto 9 m long steel poles including removing oily/greasy spots and applying two coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters of approved size on black background etc complete all as specified and as directed.
S&F in replacement waterproof underwater rgb flood light, 18w, stainless steel shell material, color temp 3000-6000k, color rendering index 80, pf>.95, input volt 24v, no of led bids as per existing at site including taking down old one complete all as specified and as directed.
S&F in replacement of extended terminals of any size and capacity as per site requirement complete all as specified and as directed.
S&F in replacement of spare handle shaft and connected accessories suitable for any size and capacity of mccb as per size requirement complete all as specified and as directed.
S&F in replacement of spare neutral link suitable for any size and capacity complete all as specified and as directed.
S&F in replacement of din type HRC fuse link of 80/100/125 Amp capcity complete all as specified and as directed.
M&L for disconnecting all electrical cables and taking down the old existing unserviceable Feeder Panel of any size and model including all accessories at NBC and supply, installation, testing and commissioning in repairs of Feeder panel enclosure outdoor type for street light totally enclosed with front opening hinged doors with canopy sloped top projected and raised platform of suitable sizes, weather dust vermin proof enclosure (size not less than 960mm x 1050mm x300mm(W x H x D)) made out of 3.15mm thick CRCA sheet, factory made (CPRI approved manufacturer) powder coated painted as approved colour, copper bus bar suitable for 3 phase 4 wire suitable for 440 Volts 3-phase, 50 Hz, AC supply. It shall be mounted on angle iron stand of size 50x50x6mm duly grouted or welded on floor or PCC platform made out of 1:2:4 type B1 with suitable nut, bolts, washers etc., all as specified and directed for suitable to in and including accomodate the following items and all as specified and directed by engr-in-charge. Copper bus bar of capacity 200 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators and providing danger notice plate of size 300 x 200mm x 3mm thick duly marked skull & bones with night glow highlighter fluorescent paint complete. (a) Incomer :- MCCB 100 Amp, TP, 36 KA-01 no (b) Outgoing :- DP 40 amp - 04 nos, TPN 63 Amp- 01 no (c) Termination of all cables with suitable size thimble and gland-1 job Note: Contractor should visit the site before participating in bidding.
M&L for calibration of IDMT relay non direction O/C + E/F suitable for 440 V LT ACB with calibrating machine with respect to time and fault level and alignment of disc spring complete including replacing of auxiliary coil/ contacts/bridge rectifier/ Electro magnet/spacer if required complete all as specified and as directed.
Attending breakdown/ inspection of dry type 1600KVA transformer by OEM service engineer to check and replace any spares related breakdown complete all as specified and as directed.
Attending breakdown/ inspection of oil type 1600KVA transformer by OEM service engineer to check and replace any spares related breakdown complete all as specified and as directed.
Supply only in replacement elctric proof rubber hand gloves suitable for 11 kv complete all as specified and as directed.
Supply only in replacement elctric proof rubber shoes suitable for 11 kv complete all as specified and as directed.
P S TRADERS (BID ID -3108543)
GLIBS CONSTRUCTION (BID ID -3110094)
SANJEEV ENTERPRISES (BID ID -3102238)
Pradeep Bros (BID ID -3106317)
R R Associates (BID ID -3099973)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .