Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC SARAT PALLY 95 97 BANK COLONY ENGLISH BAZAR MALDA WEST BENGAL 732101 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732101 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹21.3 L+₹84,125 (4.11%)Rejected-Finance 86 SOMNATH LAHIRI SARANI KOLKATA 700 053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹24.8 L+₹4.3 L (21.1%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
14 Jan 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Construction of Malda Model Madrasah (Eng Medium)-Balance work for Const of Seminar Hall Auditorium Boundary wall Pathway and Land Development of Malda Model Madrasah at Uttar Ramchandrapur, Malda - SITC of AC Machine for Auditorium and Seminar Hall
2021_WBPWD_357994_1
WBPWD/EE/MED/e-NIQ-39/2021-22
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹40,000
2 Mar 2022
27 Dec 2021
17 Jan 2022
28 Dec 2021
14 Jan 2022
31 Dec 2021
120 days
Amount
Supply of 7.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr (26.37KW) with 2/3 Nos. compressor(Rotary/Twin Rotary/Scroll), 1/2/3 nos. IDU of rated power supply-240V(+/-5%)-1ph-50Hz. , 1no. ODU of rated power supply-415V(+/-5%)-3ph-50Hz. Air-flow:- 3000CFM. Refrigerant gas R410A/R32 (Make: Bluestar/ Hitachi/ Carrier/ Mitshubishi Electric)-Warranty for AC machines incl Compressor-3 years from date of commissioning.
Supply 5.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 66000 BTU/hr (19.3KW) with 2/3 Nos. compressor(Rotary/Twin Rotary/Scroll), 1/2/3 nos. IDU of rated power supply-240V(+/-5%)-1ph-50Hz. , 1no. ODU of rated power supply-415V(+/-5%)-3ph-50Hz. Air-flow:- 2200CFM. Refrigerant gas R410A/R32 (Make: Bluestar/ Hitachi/ Carrier/ Mitshubishi Electric) -Warranty for AC machines incl Compressor-3 years from date of commissioning.
Inatallation, Testing and Commissioning charges including leak test, refrigerant Gas charging, making hole on wall, mending good to damages for 5.5/7.5 TR Concealed Split Air Conditioner.
Supply & installation of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall.
a) Liquid Line(3/8"OD with 0.6mm thick)
b) Suction line(5/8"OD with 0.7mm thick)
S & F nitrile rubber tube Insulation on suction/liquid line copper pipe of concealed split AC.
a) Liquid Line
b) Suction line
S & F of 4 core 4.0sq.mm. PVC insulated 'FRLS' Cu cable for connection between indoor & outdoor units of concealed split AC machines (Make: Polycab/ Finolex/ Havells/ KEI).
S & F flexible double canvass connection for concealed split air-conditioners.
S & F Al. powder coated continuous grill.
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 7.5 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the existing wall. Area of the platform is 3Mtr. x 1.2Mtr. (as per direction of EIC).
Supply, fabrication and installation of drop ceiling to cover the indoor units made up of Fire-proof Gypsum board with aluminium channel structure incl. colouring of Gypsum board as per wall colour or as per direction of EIC.
Charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of plywood in existing aluminium channel & gypsum board for IDU maintenance.
Supply of 4.0 TR capacity floor standing(Tower) Air Conditioner machine of rated cooling capacity of 48000 BTU/hr (13.5KW) with 1/2 Nos. compressor(Rotary/Twin Rotary/Scroll), Rated power supply-415V(+/-5%)-3ph-50Hz. , Copper Condenser, Air-flow:-1200CFM. Refrigerant gas R410A/R32 (Make: Bluestar / Hitachi / Carrier / Mitshubishi Electric / Daikin / Voltas) - Warranty for AC machines incl Compressor-3 years from date of commissioning.
Installation of 4.0 Tower AC machine on floor with MS Base Square shape painted including making hole on wall and fixing out door unit on suitable MS strauture on wall, making gas and liquid line connection, electric cable connection and drain pipe connection, making hole on wall, mending good to damages.
Supply & installation of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall.
a) Liquid Line(9.52 mm OD with 0.6mm thick)
b) Suction line(19.05mm OD with 0.7mm thick)
Supply & fixing nitrile rubber tube Insulation on suction/liquid line copper pipe of concealed split AC.
a) Liquid Line
b) Suction line
Supply and delivery of 1.5 Ton SPLIT type room air conditioner machine having the following specification:- (a) Cooling capacity nominal (BTU):18000 (b) Star rating- 3 to 5 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary, Condenser and evaporator- Copper Coil (e) Refrigerant : R32/R410A (f) Mini. Room Discharge air flow rate 600CFM. (g) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years. (MAKE- O-GENERAL / Daikin / Hitachi / Carrier) and the Split AC machine should be warranted for 3 years.
Installation testing and commissioning of 1.5 Ton split type AC machine on wall by appropriate mounting kit and testing whole refrigeration system with all joints, valves etc incl leak testing, supply and filling refrigeration gas, making hole in wall, mending good to damages.
Supply and installation of Copper refrigeration pipe of suitable diameter, insulation of pipe by black kenefoam, tape joiting material, connecting IDU and ODU by 3 core 2.5MM Copper Wire for 1.5 Ton split AC machines as par direction of EIC.
5/8" copper pipe.
1/4" copper pipe.
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors - 40 mm dia.
Charges for scaffolding arrangement incl. lifting of outdoor & indoor units of AC machines (total 14 nos).
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS /IEC specifications. (iii) Necessary manufacturer's warranty certificate for AC machine & ERV Systems will have to be submitted during delivery of the material.
Lyric International
SKY DECORATIONS PRIVATE LIMITED
stage.html
html • 0.05 MB
technical_692180.pdf
PDF • 0.04 MB
techsummary_692180.pdf
PDF • 0.51 MB
finance_692180.pdf
PDF • 0.05 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_692180.pdf
PDF • 0.67 MB
AOC.pdf
PDF • 0.93 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .