Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹85.3 LAdmitted-Finance | +2.80% | ₹85.3 L | L1 | Admitted-Finance |
| 2 | L2₹87.0 LAdmitted-Finance | +4.80% | ₹87.0 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Non Responsive |
Tender Value
₹83.8 L
EMD Value
₹1.7 L
Closing Date
23 Feb 2026, 6:00 pmClosed
EO Nagar Palika, Rawatbhata
EO Nagar Palika, Rawatbhata
Development and Beautification work of the Park in Sardar Bhagat Singh Nagar Housing Scheme, Rawatbhata
2026_DLB_538202_4
NIT No. 10/2025-26 (No. 891)
Open Tender
Civil Works
120 days
Rawatbhata
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EO Nagar Palika, Rawatbhata
₹1.7 L
Yes
4 Mar 2026
13 Feb 2026
24 Feb 2026
13 Feb 2026
23 Feb 2026
13 Feb 2026
Part - "A"
Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In ordinary rock. Depth upto 1.5 m
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). Depth upto 1.5 m
Random Rubble masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with clay flyash brick of class designation 75 in superstructure above plinth level upto two stories in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine/ coarse sand)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 40 Kg per Sqm
Part - "B" (Earth Filling)
Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead.
Supplying and stacking of well decayed cow dung manure at site.
Carriage of Materials by mechanical transport including loading, unloading and stacking : Earth (5 Km)
Part - "C" (Flooring and Pathway)
Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301. In all type of soil
Random rubble dry stone Kharanja (soling) under floor.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Random Rubble masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and Fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimum compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer-in-charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications.
Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M-10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer
Part - "D" (Planter work)
Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301. In all type of soil
Random rubble dry stone Kharanja (soling) under floor.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Brick work with clay flyash brick of class designation 75 in Superstructure above plinth level upto two stories in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:6 (1 cement : 6 fine/ coarse sand)
Part - "D" (Horticulture work)
Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction
Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart.
Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height shurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
Rhaphis excelsa with 3-4 suckers (Lady Palm)
Phonenix sylvertris (Date Palm)
Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc. as required.
Wedelia trilobata (Sun Flower Family)
Alternathera green (Parrot Leaf)
Resine herbstii (Blood Leaf)
Ophiopogon Black (Lily Turf, Mondograss)
Asparagus myerii (Fox Tail)
Lantana sellowiana
Rhoeo spathacea 'Compacta‘ (Oyster, Boat Lily)
Golden duranta
Pennisetum setaceum (Fountain Grass)
Supply and planting following species best quality container grown healthy trees of 2 mtr. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc. as required.
Plumeria alba (Champa)
Gulmohar (Delonix regia)
Quis quallis indica (Madhu Malti)
Morning glory (Ipomea)
Mangifera indica (Mango)
Part - "E" (Electric work)
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 2×4.0 sq.mm. + 1×2.5 sq.mm.
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm, conductor line load reversibility, label holding facility, IP-20 contact protection and fitted with existing distribution board/sheets, min. operation 20000 upto 32 A rating and 10000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
Single pole MCB, 6 A to 32 A rating
Four pole MCB, 50-63 A rating
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS:7098 P-I of Group-I of approved make in ground as per IS:1255 including excavation of 30cm × 75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 25.0 Sq.mm, 3 core
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof comparetmentalised cubical panel as specifications and Other parameters required as per point (a), (b), (c), (d), (e), (f), (g), (h) as below : (a) Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness, required hardware, concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5
sq.mm braided copper wire. (c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp) and by solid bus bar (>63 amp). control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned. Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (Cost of Bus bar/Flexible wire for Inter connection between Main busbar and Switchgear is to be Paid Extra) (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and
identification strips shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100×50×5 mm (to be paid Extra) (g) Tests : The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both
before and after high voltage power frequency test. The insulation resistance shall not be less than three mega ohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
Supplying and Fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. Electrolytic grade copper bus bar
Plate Earthing as per IS:3043 with copper Earth plate of size 600mm × 600mm × 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm × 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG copper Wire
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, riveting, cutting, nut & bolt, Painting etc. as required.
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P-2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6%, Insulation Screening: Extruded Semi conducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables, Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 3 core 185.0 Sq.mm
External Area Electrification Add for supply and fixing of MS Overhang of following size over the existing poles. Overhang shall be painted with two coat of red oxide primer and two quote of enamel paint of silver colour as per the direction of Engineer incharge All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 76.1mm OD × 3.25mm thickness
Supply & Erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) & confirming to BSEN 10025 & shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside & outside. The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base
plate with bakelite sheet having 6A SP MCB & 16 sqmm stud type connector (4 nos.) inside the pole at door opening for cable connection of following length & dimension as per table P-01 with base plate & foundation bolt on the Existing cement concrete foundation. All as per pre approved by Engineer-in-charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR. 7Mtr.
P&F of fuse box size 250(H) × 200(W) × 150(D) mm with base shape accomodating the pole partly, fabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos. pole clamps of 25mm × 3mm flat with nut & bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2/4 nos. copper bus bar 150×20×3mm with brass screws suitable supports, earth terminal, inter connection, brass cable gland upto 10 Sqmm size cable, 2 nos. 16 Amp kitkat fuse complete in all respect.
P & F of IP-66 protected high power LED flood light system with extruded aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps supplied with pre wired cable of 1 mtr. Integrated driver shall be high efficiency having efficiency more than 85% and in compliance to IEC standards. System life of 50000 burning hours with 70% of initial lumen be maintained. Light output in red, green, blue, cool white or warm white colour as per engineers choice. Fixtures shall be CE compliance. linear LED strip 1 feet (with driver)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_959135.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid