| 1.00 | Supply of PVC insulated and sheathed 10.0 Sq.mm 3 core flat type copper cable conforming to IS 694 / 1990 etc., complete. | 130 | 1Rm | 465 ₹60,450 Lowest | 470 ₹61,100 |
| 2.00 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % | 1 | 1Nos | 67,000 ₹67,000 Lowest | 68,000 ₹68,000 |
| 3.00 | Supply and delivery of Star-Delta starter confirming to IS13947, IEC 60947-1 suitable KW rating for operation in AC / three Phase / 50Hz (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On / Off Push button switches, wiring with 1 sq.mm / 4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | 1 | 1No | 16,000 ₹16,000 Lowest | 17,000 ₹17,000 |
| 4.00 | Labour Charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. | 1 | 1No | 13,350 ₹13,350 Lowest | 14,000 ₹14,000 |
| 5.00 | Earth work excavation and depositing on bank with initial lead and lift as initial of 10 M and lift of 2 M in narrow trenches for laying of pipes for water supply works in Hard stiff clay, stiff black cotton, hard red earth shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravel soil including refilling the sides of foundation in layer of 15m thick watering ramming depositing the surplus earth in the premises as directed by the departmental officers etc., complete complying with standard specification. | 90 | 1M3 | 319 ₹28,710 Lowest | 320 ₹28,800 |
| 6.00 | Supply and delivery of the following size of PVC pipe with IS specification etc., complete. | 70 | 1Mt | 140 ₹9,800 Lowest | 150 ₹10,500 |
| 7.00 | Supply and delivery of MS Kiosk of size 0.75m x 0.45m x
0.75m made up of MS angle of size 50mm x 50mmx 4mm
alround covered with 16 gauge MS sheet and kiosk door
made up of MS plates of size 25 mm x 3 mm including
cutting, welding, grinding, locking arrangements and
labour charges etc., | 1 | 1Nos | 18,770 ₹18,770 Lowest | 19,000 ₹19,000 |
| 8.00 | Lowering PVC(OD) Rigid Pipes and Specials in the trenches and laying to proper grade and alignment Joining with PVC Couplers with Cement Paste and testing to the required pressure includind conveyance of water for filling during testing. | 1 | 1Nos | 1,090 ₹1,090 Lowest | 1,100 ₹1,100 |
| 9.00 | Supplying of Miniature Circute as per IS specifications including conveyance of all materials to the site etc., complete as per DPC specification | 1 | 1Nos | 1,140 ₹1,140 Lowest | 1,200 ₹1,200 |
Tender Value
₹3.8 L
EMD Value
₹7,600
Closing Date
9 Sept 2025, 3:00 pmClosed
Commissioner
Tiruppur City Municipal Corporation Office, Tiruppur
Supply and Delivery and Erection of 5.0 HP Pumpset Stater Cable and PVC Pipe at Karupparayan Kovil Street in Ward No 22
2025_MAWS_598019_7
150/2025-26/Z2/EE,Tcmc
Open Tender
Civil Works
Works
90 days
Tiruppur City Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,600
14 Oct 2025
3 Sept 2025
9 Sept 2025
3 Sept 2025
9 Sept 2025
3 Sept 2025
Amount
Supply of PVC insulated and sheathed 10.0 Sq.mm 3 core flat type copper cable conforming to IS 694 / 1990 etc., complete.
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %
Labour Charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
Earth work excavation and depositing on bank with initial lead and lift as initial of 10 M and lift of 2 M in narrow trenches for laying of pipes for water supply works in Hard stiff clay, stiff black cotton, hard red earth shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravel soil including refilling the sides of foundation in layer of 15m thick watering ramming depositing the surplus earth in the premises as directed by the departmental officers etc., complete complying with standard specification.
Supply and delivery of the following size of PVC pipe with IS specification etc., complete.
Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,
Lowering PVC(OD) Rigid Pipes and Specials in the trenches and laying to proper grade and alignment Joining with PVC Couplers with Cement Paste and testing to the required pressure includind conveyance of water for filling during testing.
Supplying of Miniature Circute as per IS specifications including conveyance of all materials to the site etc., complete as per DPC specification
P.S. ASSOCIATES (BID ID -1453478)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .