Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹13.5 L+₹1.3 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹13.9 L+₹1.7 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹14.0 L+₹1.8 L (14.6%)Rejected-Finance 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹14.6 L+₹2.5 L (20.3%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
9 Apr 2021, 6:00 pmClosed
Maj Rahul Rawat
GE utility Bathinda Mil stn
REPAIR MAINTENANCE OF WATER COOLERS REFRIGERATORS AND DEEP FREEZERS AND CONNECTED ITEMS OF BATHINDA MIL STN ZONE -A UNDER GE (U) BATHINDA
2021_MES_429688_1
8550/2021-22/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class E cat b i or c i
9 documents required · 9 mandatory
₹500
GE (U) BATHINDA
₹38,000
Yes
27 Apr 2021
10 Mar 2021
12 Apr 2021
10 Mar 2021
9 Apr 2021
25 Mar 2021
Amount
Servicing of Refrigerator 286 to 310 litres capacity including cleaning, checking of electrical connections etc. as in preventive maintenance complete all as directed.
All as per serial item No. 01 above but for Refrigerator 165 to 220 litres capacity.
All as per serial item No. 01 above but for Deep Freezer Upto 400 ltr capacity .
S&F in repair Compressor (sealed unit ) of refrigerator of capacity 160 / 175 / 220 ltrs AC 230 Volts single phase refrigrator procured directly from manufacturer or authorised dealer alongwith test certificate from the manufacturer (with Two years guarantee) including starting relay assembly with Over Load Protector , commissioning and testing on full load of compressor including supply and charging of refrigerant gas in the system its rated capacity and including replacement of copper filter single capilary complete all as directed. Make : LG / Whirlpool / Godrej
All as per serial item No 04 above but for Refrigerator of (any make) of capacity 286 / 310 / 350 ltrs capacity . Make ; LG / Whirlpool / Godrej
All as per serial item No 04 above but for Deep Freezer of (any make) of capacity 280 / 300 / 310 ltrs capacity. Make ; LG / Whirlpool / Godrej
All as per serial item No 04 above but for Refrigerator Invertor type technolgy of capacity 160 / 175 / 220 ltrs of any make and type. Make ; LG / Whirlpool / Godrej
All as per serial item No 04 above but for Refrigerator Invertor type technolgy of capacity 286 / 310 /350 ltrs of any make and type. Make ; LG / Whirlpool / Godrej Note for serial item No. 04,05,06,07 and 08: (i) The rate of Supply and Fixing of New Compressor of suitable capacity ,starting relay assembly with Over Load Protector is inclueded in this item and nothing shall be paid extra on this account.(ii) The rate of Supply and charging of Gas is also included in this item and nothing shall be paid extra on this account.(iii) The unit rate quoted by the contrcator is also included replacement of foundation rubber bushes, nuts, and bolts , necessary electrical connection for making the appliances functional and cleaning of condenser etc.and nothing shall be paid extra on this account.
Opening and removing the Compressor, Condensor coil of the Refrigerator of capacity 286 ltrs / 310 ltrs / 350 ltrs of any make, cutting the rusty unserviceable lower portion of the body cover including supply, fabrication and fixing the lower portion made out of MS sheet as per original size and shape, reassembling the refrigerator, scratching out the old paint with emery paper and making the surface smooth and applying two coats of synthetic enamel paint of original shade / coulor on full body of refrigerator by using spray gun and applying anti corrosive black paint with spray maching to compressor and condenser coil complete all as directed.
All as per serial item No 09 above but for capacity of Refrigerator 175 ltrs.
Material and labour for removing the aluminium sheet of Deep freezer of any capacity, removing the existing condenser tube and cleaning the surface with CTC solution and fitting of new copper tube of suitable size including PUF insulation and covering with new aluminum sheet and making the surface as original one complete all as directed.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and charging R-134 gas upto the required pressure complete all as approved and directed.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and charging R-600 gas upto the required pressure complete all as approved and directed.
S&F in repair Thermostat Switch with knob for any capacity of Refrigerator complete all as directed. Make : LG/Whirlpool
S&F in repair Starting Relay Assembly with Over Load Protector any model. Complete all as directed. Make : ANNAPURANA / HITACHI / WHIRLPOOL / TECUMSEH / LG
S&F in repair Freezer Door complete including Bracket suitable for 165/175 ltrs capacity Refrigerator of make Whirlpool / Voltas / LG Complete all as directed.
S&f in repair Freezer Door complete including bracket suitable for 286 / 310 ltrs capacity Refrigerator of make Godrej / Whirlpool / Voltas / Kelvinator / LG Complete all as directed.
S&F in repair Aluminium Freezer Shell suitable for 165/175 ltrs capacity refrigerator of make : LG / Godrej / Whirlpool / Voltas / Kelvinator Complete all as directed.
S&F in repair Aluminium Freezer Shell 286/310/350 ltrs capacity refrigerator of make : Godrej/Whirlpool/Voltas/Kelvinator Complete all as directed.
S&F in repair Plastic Vegetable Tray Heavy duty suitable for Refrigerator 165 /175 ltrs of capacity of any make any type complete all as directed.
S&F in repair Plastic Vegetable Tray Heavy duty suitable for Refrigerator 286/310/350 ltrs of capacity of any make any type and as approved by Engineer-in-Charge.
S&F in repair Condenser suitable for Refrigerator 175 ltrs capacity complete all as directed.
S&F in repair Condenser suitable for Refrigerator 286 / 310 ltrs capacity complete all as directed.
S&F in repair Copper tube, 6.35 mm dia, superior quality suitable for Deep freezer complete all as directed.
S&F in repair PCB Module 230 Volts, 50 Hz C/S suitable for Double Door Refrigerator of make Whirlpool / LG complete all as directed.
S&F in repair Bimetal 230 Volts, 50 Hz C/S suitable for double door refrigerator of make Whirlpool/LG Make complete all as directed.
S&F in repair Defrost Timer 230 Volts, 50 Hz C/S suitable for Refrigerator of 160 / 175 / 220 ltrs capacity of make Whirlpool/LG complete all as directed.
S&F in repair Cooling Fan Motor suitable for Double Door Refrigerator of 286 / 310 ltrs capacity and make Whirlpool / LG complete all as directed.
S&F in repair Defrost timer suitable for Double Door Refrigerator capacity 286 / 310 / 350 ltrs of make Whirlpool/LG complete all as directed.
S&F in repair Cooling Fan Motor suitable for Deep Freezer 280/300 ltrs capacity complete all as directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 40 liters capacity of any make and type and repalace with new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 444, AE 4440 YGS including suitable relay, over load and starting/running capacitor, flushing out the old bunt condensite from the gas system by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, gas charging with R-134 gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 60/120 liters capacity of any make and type and repalace with new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 443, AKR 4460 including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 150 liters capacity of any make and type and repalace with new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG, model ACJ 513, AW 1000, including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a/22 gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed.
S&F in repair blower fan motor 1/10 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.
S&F in repair blower fan motor 1/35 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.
S&F in repair Fan blade plastic suitable for 1/35 HP motor complete all as directed.
S&F in repair Fan blade plastic suitable for 1/10 HP motor complete all as directed.
S&F in repair stainless steel taps push button type, 15mm dia for water cooler of any capacity suitable for Usha/Blue Star water coolers complete all as directed.
S&F in repair Relay & overload set suitable for water cooler complete all as directed. Make : Annapurna/Reneutral/Denfoss
S&F in repair Running capacitor of 15 mfd complete all as directed.
S&F in repair Running capacitor of 40/60 mfd complete all as directed.
S&F in repair Thermostate valve complete all as directed.
Material and labour for taking out the inner water tank of water cooler of any size and brazing/welding including applying compounds as required to stop leakage from the water tank, replacement of glass wool/toffed sheet, chicken wire mesh of appropiate thicness and spacing and stoppage of leakage in tubing (if any) around the tank and refixing as per oringinal pattern complete all as directed.
S&F in repair copper condesor for 40/80 ltr capacity water cooler complete all as directed.
S&F in repair copper condesor for 60/120 ltr capacity water cooler complete all as directed.
S&F in repair 3 pin, 15 Amp top plug, 240 Volts, single phase complete all as directed. Make : Anchor/Havells
S&F in repair PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for 15mm bore pipe complete all as directed.
S&F in repair copper cable 3 core round of size 1.5 mm long including making connection complete all as directed. Make : Havells/Polycab/HPL
S&F in repair drain hose pipe not less than 1.5 metre length and 30mm dia with clamping arrangment complete all as directed.
S&F in repair drain hose pipe not less than 1.5 metre length and 40mm dia with clamping arrangment complete all as directed.
S&F in repair Water Cooler Stainless Steel body unit with Condenser Coil, Copper Wound Fan Motor and tank including heavy duty copper tubing, stainless steel taps push button type 15 mm dia of 40/80 ltr capacity complete all as directed.
L H ENTERPRISES
Sandeep Enterprises
VISHAV CONSTRUCTIONS
M/S SODHI ASSOCIATES
M/s Kataria Construction Company
NASIB ENGINEERS AND CONSTRUCTION
MODERN ENTERPRISES
M/s SUPERTECH ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .