| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Structural steel for canopy | Structural steel for canopy — Supplying, transporting, fabricating, erecting in position in position of Pre- fabricated steel structures at all elevations for Canopy using structural steel sections ISMB/ISMC/ISA conforming to IS:2062 and IS 226 , including cutting, welding or bolting, supply of bolts/nuts/washers etc., complete as per drawings including surface preparation and applying one coat of Zinc Phosphate Primer before erection, one coat after erection and two coats of synthetic enamel paint as per specification after erection and all materials and labour complete. ( No welding is permitted at site). The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes and any other consumables required for completing the work. Nut bolts shall not be considered for payment.Theoretical wight of steel sections shall be considered for payment..(.(No measurement shall be taken for nut,bolt,washer splice plate & gusset plate) | - | Metric Ton |
| 2 | Klippon Roofing | Klippon Roofing — Supply and fixing Clippon Roofing System:Roofing base material should be of cold rolled steel of 0.55 mm thick and conform to ASTM:A 446 having yield stress of 275 MPA . The coating should be Aluminum and Zinc alloy comprising 55% Al , 43.5 Zinc & 1.5 % Silicon , as per ASTM :A 792 . The coating mass should not be less than 150 Gms per SqM (total of both sides). For, bare galvalume, TCT should not be less than 0.55 mm . Sheets shall have approved side laps with top sheets facing away from the prevailing weather. Necessary profiled filler box should be provided at higher level of roof sheeting and at valley gutter to ensure water tightness in the profiled gaps . The fixing of roofing shall be done in such a manner that the roof is not drilled / punctured for fixing with the purlins .Refer to the approved makes given in the Attachment. Flashings, Cappings and trims:These shall be formed out of same substrates as that of the roofing sheets and shall be supplied in standard lengths of 2.5 M in the required shapes and girths and fixed by means of hex-head mechanically galvanized stitching screws. Silicon sealant non-hardening neutral cure type shall be applied at all laps to avoid water seepage. | - | Square Meters |
| 3 | False ceiling | False ceiling — Providing & fixing false ceiling system of Trac 150 F exterior grade or approved equivalent of 0.5mm thick galvanised steel with stove enameled coil coated finish inter locking ceiling panels, carriers, suspension system and edge closure as per the following specification. Supplying and installation of exterior grade 150 F ceiling system comprising of 150 mm x 17 mm deep panels roll formed out of 0.5 mm galvanised steel with stove enameled coil coated finish. The panels shall be pre-treated and coil coated on one side in manufacturers standard colour shades as approved by the Architect/ Engineer in charge. The rear side of the panel shall be given a coat of primer and a wash coat while the finished side shall be given a coat of primer and finish colour coat in polyster paint for a min. dry film thickness of 20 microns, fixed on to the roll formed carriers 34.5 mm x 488 mm deep out of 6 mm thick Galvanised steed with prongs to hold panels in the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss by rigid suspension angles as per manufacturer's recommendation. Panels shall be supplied in custom length upto maximum of 5 mts. Job also includes providing ceiling flashing using factory formed 0.5 mm thick Polyster coated galvanised steel material. Rate shall be including providing flashing to cover gap if any between illuminated banding and false ceiling. | - | Square Meters |
| 4 | GI Fascia | GI Fascia — Supplying and fixing 20 SWG GI sheet facia including painting with one coat of zinc chromate primer and two coats of 1 st quality synthetic enamel paint on front side . Necessary facia framework for fastening the sheet to the canopy securely shall be paid separately. | - | Square Meters |
| 5 | AL Gutter (2mm Thick) | AL Gutter (2mm Thick) — Providing and fixing 2 mm thick Aluminum Sheet Gutters of required shape in slope with 40 mm x 3 mm MS. Brackets at 1000 mm maximum spacing and 8 mm dia G.I. J or L hooks, boltsand nuts, GI Limpet and bitumen washers, providing nut bolt joint , sealing the joints with silicon sealant testing the gutter for leakage by filling water etc. Complete.(Refer attached Drawing .For allowable tolerance refer to IS codes | - | Meters |
| 6 | 6" PVC Pipe | 6" PVC Pipe — Providing and fixing 6" dia PVC pipes of 6 Kg/sqcm of approved Make as per IS 4985 for rain water pipes including all fittings like bands , shoes etc., MS fabricated bracket as per requiment etc. All complete as directed by the EIC. | - | Meters |
| 7 | 80 W LED Light Fixture | 80 W LED Light Fixture — 80 W LED Fitting as mentioned in IS standards IS 16101 to 16107:Supply and fixing of 80 W LED housed by Single piece Pressure Die Cast Aluminum body, recess mountable fitting with guaranteed burning hours of 50000 .Make Philips/Havells/Bajaj/Wipro/Osram/Crompton/GE/Bever Innovations. IP Protection of minimum IP 65 and above, suitable for canopy lighting at retail outlets (Petrol station) .The bidder should submit copy of certified photometric report as per IESNA LM-79(Approved method for the Electrical and Photometric Measurements of Solid-State Lighting Products) from a UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC. A minimum 3 years warranty from manufacturing defects for the luminaire by manufacturer.i) With high lumen efficacy LEDs from CREE, Seoul Semi- Conductor, Lumiled Philips, Osram, Nichia (Japan), Tridonic (Austria), GE and Bridgelux . Efficiency of more than 90 lumens per watt . LEDs used in the fixture should be from the same bin and certified as per LM-80 (IESNA: Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70 based on LM-80 data). by any UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC.ii) Bottom open able for easy maintenance.iii)High Quality Polycarbonate Opal Diffuser for Optimum uniformity and Glare free light output.iv) General electrical protection against High Voltage and Surges up to3 KVv) Power factor > 0.95vi) Range allowed for total system wattage 80 W with +2W or -2W vii) Driver Operating Voltage Range: 140 V- 270 V viii) Operating Temperature 0 to +45 Deg Centigrade viii) CRI more than 70 ix) Colour temperature5650K±500K (to be mentioned in LM 79 certificate) x)Wide beam angle for spread of light 120 degrees or more xi)Luminaire Performance Complies to IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529, ROHS | - | Each |
| 8 | 4C X 2.5 SQMM Copper Cable | 4C X 2.5 SQMM Copper Cable — Supply and laying following size PVC insulated, sheathed, armoured cable of approved make conforming to IS 1554:Part 1:1988 4CX2.5SQMM COPPER CABLE | - | Meters |
| 9 | 4CX2.5 SqMM End Termination | 4CX2.5 SqMM End Termination — END TERMINATION End termination of following cable with double compression NFLP gland and crimping sockets 4CX2.5 SQMM END TERMINATION | - | Each |
| 10 | HiRib Roofing | HiRib Roofing — Providing and installing roofing Ribbed roofing system manufactured with high strength steel grade of G550( 550MPa) of ZINCALUME steel or approved equivalent bare Galvalume high tensile cold rolled steel as per ASTM 117 A792M /AS 1397 Coating class AZM 150 ( minimum 150 gm/sqm Zinc-Aluminium alloy coating mass total of both sides),of Yield strength 550 Mpa Thickness of bare metal (BCT): 0.40mm ,Total coated thickness(TCT) : 0.45 mm .Approximate mass of roofing sheet shall be 4.17 Kg/sqm. Panels shall be of Min. 900 mm wide and Min. corrugation depth of 38 mm with varying lengths as per Site requirements Rate shall be including laying of sheets with approved fasteners and also all weather sealant tape as per Mfr's recommendationsand also providing ribbed galvalueme ridge pieces of the same class as of the matching corrugation profile of the roofing system as recommended by the Mfr.and , horizontal/vertical flashing near illuminated banding . | - | Square Meters |