| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | ₹27.3 L Quoted ₹28.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹30.5 L+₹1.8 L (6.33%)Rejected-Finance | ₹30.5 L+₹1.8 L (6.33%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹37.9 L+₹9.2 L (32.2%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹37.9 L+₹9.2 L (32.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹40.2 L+₹11.5 L (40.1%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹40.2 L+₹11.5 L (40.1%) | L4 | Rejected-Finance Other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Jul 2024, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Repair/ replacement and maint of misc E/M items such as DG Sets, lifts, sewage installations, fire alarm and fire fighting eqpt and swimming pool items under GE Gurdaspur.
2024_MES_660877_1
GE GSR-44/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹96,000
26 Oct 2024
20 Jun 2024
25 Jul 2024
20 Jun 2024
17 Jul 2024
5 Jul 2024
Amount
Repair to alternator 110 KVA/100 KVA disconnecting electrical connection from site carefully and shifting for repair to workshop dismantling the complete alternator dismantling stator winding carefully and rewinding of stator with super enamelled existing size of copper winding wire with insulation material and varnish. Reassembling after repair and shifting to site and testing on load with full satisfaction of Engineer - in - Charge Note : All T&P, Vehicle and labour shall be provided by contractor.
Supply and replacement of self starter Assbly 12 volt complete with battery lead and battery terminal suitable for 100 to 125 KVA DG Set all as directed Make Lucas or as equivalent all as directed and specified
Repair overhauling of self starter 12 Volts including replacement of worn out clutch, repair to main AUX field coil, solenoid switch, carbon brushes, spring and rewinding of armature etc for 25 KVA to 63 KVA DG set. Make Lucas
All as per Srl item No 3 above here-in-before but for 100 KVA to 125 KVA DG Set all as specified and directed
M & L for Repair /overhauling of dynomo including supply & replacement of new carbun brush and re-winding of armature and testing on load of the DG set of capacity 100 KVA all as directed by Engineer in Charge
M & L for taking out existing non clog sewage pump, set of any type and size from sewage sump (alongwith existing column pipe) including all fittings complete all as specified and directed. Note : All T & P vehicle and man power shall be provided by contractor.
M & L for Lowering of non clog sewage pump, set of any type and size in sewage sump (alongwith column pipe) including all fittings complete all as specified and directed. Note : All T & P vehicle and man power shall be provided by contractor.
M & L for Disconnecting and taking out motor from non clog sewage pump, dismantling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton tape, varnish , insulation paper , sleeves and dry & baking etc connections etc and assembling complete after duly repair installation, commisioning and testing upto the satisfactory working performance including replacing bearing for NDE & DE side of motors for the capacitiy 12.5 HP, 3 Phase, 415 Volt, complete all as specified and directed. NOTE: All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs 2000/- per days will be levived on the contractor.
S&F in replacement of CI Impeller sutaible for 12.5 HP sewage non clog pump set complete all as specified.
S&F in replacement of Ball Bearing as per sample for 12.5 HP sewage non clog pump set etc complete all as specified.
S&F in replacement MS tail piece, 6" dia, length as required, both end flanged, with nuts bolt and rubber flanged complete in replacement of existing unserviceable tail piece all as specified and directed.
Supply and fixing in replacement rubber insertion sheet/gasket sheet 4 mm thick for flanged MS/CI/DI pipe of dia 80 mm in replacement of old damaged rubber gasket sheet all as specified and directed.
Supply and fixing in replacement rubber insertion sheet/gasket sheet 4 mm thick for flanged MS/CI/DI pipe of dia100 mm in replacement of old damaged rubber gasket sheet all as specified and directed.
Taking out, dismantaling the mono block pump motor, from foundation / site, transporting the same to workshop, taking out of all burnt winding wires by strip opening of 3phase electric motor of any make, rewinding the motor with super enamled copper winding wire of required gauge and quantity including varnishing insulation sheet cotton, glass sleave etc as required, reassembling,testing, transporting back to site from workshop, installing back and making connection and again testing for motor capacity 0.5 HP to 1 HP complete all as specified and directed NOTE: All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs 500/- per day will be levived on the contractor.
All as per Srl item No 14 here-in-before but for motor of capacity 2HP to 4HP
All as per Srl item No 14 here-in-before but for motor of capacity 5HP to 7.5HP
All as per Srl item No 14 here-in-before but for motor of capacity 10 to 12.5HP.
Supply & Fixing Mechanical Oil Seal for 12.5 HP, sewerge submersible motor & pump including taking down old unserviceable one all as specified and directed.Make : Kirloskar or equivalent approved.
M & L in replacement battery lead acid type 180 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make-Exide/Amco/ Amaron/ Standard.
M & L in replacement battery lead acid type 120 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make-Exide/Amco/Amaron/ Standard.
M & L in replacement battery lead acid type 100 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make-Exide/Amco/Amaron/ Standard.
M & L in replacement of PVC insulated battery lead stranded copper conductor of size 50 Sq mm suitable complete all as specified & directed .
General servicing of DG Set of 12.5 KVA capacity, Make kirloskar, Model D-9, Air cooled type by cleaning externally, taking out tapet cover and carrying out tappet setting including replacement of tappet cover gasket, tightening of all external fasteners, bolts, nuts etc., cleaning of benjo bolt filter of fuel feed pump, cleaning of fuel filters, oil filters and air filter including replacement of filter elements, engine oil, fan belts, engine hoses, worn out electric wiring, meters, including toping up of coolant, electrolyte of battery etc. all as required and directed for proper designed output of gen set. NOTE: Spares e.g. fuel filter element, oil filter element, air filter element, coolant, hose pipes, fan belts, meters etc. as required to be replaced shall be measured and paid seprately as "supply only". Minor parts e.g. bolts, nuts, washers etc. including necessary T & P and cleaning materials as required for servicing shall deemed to be included in the rate quoted.
All as per Srl item No 23 here-in-before but for DG set of capacity 25 KVA to 30 KVA Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 23 here-in-before but for DG set of capacity 35 KVA 100 KVA , Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 23 here-in-before but for DG set of capacity 110 KVA to 160 KVA, Make Kirloskar, water cooled type.
Supply only for pre filter and fine diesel filter element for 12.5KVA Gen Set, Make Kirloskar
All as per Srl item No 27 here-in-before but for 25 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 27 here-in-before but for 30 KVA to 35 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 27 here-in-before but for 40 KVAto 63 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 27 here-in-before but for 100 KVA to 160 KVAGen Set, Make Jackson / Cummins and Kirloskar, water cooled type.
Supply only for oil filter element for 12.5 KVA Gen Set, Make Kirloskar
All as per Srl item No 32 here-in-before but for 25 KVA to 35 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 32 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 32 here-in-before but for 100 KVA to 160 KVAGen Set, Make Jackson / Cummins and Kirloskar, water cooled type.
Supply only rubber coupling for 12.5KVA Gen Set, Make Kirloskar
All as per Srl item No 36 here-in-before but for 25 KVA to 35 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 36 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 36 here-in-before but for 100 KVA to 160 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type.
Supply only Fan belt for 12.5KVA Gen Set of existing size, Make Kirloskar/Fenner or equivalent
All as per Srl item No 40 here-in-before but for 25 KVA to 35 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type.
All as per Srl item No 40 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 40 here-in-before but for 100 KVA to 160 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type.
Supply only of Hose Pipe Set with Clamp for DG Set of 25 KVA to 35 KVA, Make Kirloskar
All as per Srl item No 44 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type.
All as per Srl item No 44 here-in-before but for 100 KVA to 160 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type.
Overhauling and calibration of FIP assembly of 12.5 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc.and including taking out, transporting, refitting, refixing & testing complete.
Overhauling and calibration of FIP assembly of 25 KVA to 63 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc.and including taking out, transporting, refitting, refixing & testing complete.
Supply only for topping up of water coolent in radiator of DG set TVS Girling/volvo line or of equivelent make all as directed by EIC. Make Castrol, Servo, Maxoil
Supply only Of Engine Oil of DG Set of 10W-30/20W40 or equivalent of Make : Castrol/volvoline all as directed by Engineer In charge
M & L for replacement of rectifire for the DG set of capacity 12.5 KVA to 63 KVA all as specified and directed by Engineer-in-Charge
M & L for replacement of rectifire for the DG set of capacity 100 to 160 KVA all as specified and directed by Engineer-in-Charge
S&Fin replacement Automatic voltage regulator suitable for DG set for 25KVA to 160KVA. Make Kirloskar
Taking out the radiator assembly of DG set of 125 KVA capacity and transporting to work shop dismantling upper and lower tank and cleaning thoroughly, replacement of gasket packing , nuts, bolts, washers, descaling with appropriate chemical and brazing of damazed fins / tubes and reassembling & refixing in same position after testing complete.
All as per Srl item No 54 here-in-before but for DG Set of capacity 100 KVA to 63 KVA
All as per Srl item No 54 here-in-before but for DG Set of capacity 30/40 KVA
M & L for replacement of battery terminals brass with steel nuts, bolts & washers all as directed
S & F in replacement of on load change over switches 100amp, TPN, 415 Volts with sheet steel enclosure with side handle complete. Make : ABB/C&S/HPL /Havells/I ndo Asian.
All as per Srl item No 58 here-in-before but 125amp.
All as per Srl item No 58 here-in-before but 250amp.
All as per Srl item No 58 here-in-before but 400amp.
M & L in repair of on load change over switch in existing LT panel front operated with fixing arrangements 4 poles, 415 Volts, 160amp complete Make : ABB/C&S/HPL /Havells/I ndo Asian.
Supply and laying in replacement XLPE insulated armoured (under ground) heavy duty electic cablewith stranded aluminim conductor 1100 volts grade of crossectional area 16 sqmm 4 core laid in trenches/ducts/through pipes along the pole etc all as specified & directed by Engr-in-charge. Note : (a) Excavation earth work, brick protection and cushioning shall be measured & paid separately.
All as per srl item No. 63 here in beore but 95 Sqmm 3.5 core
All as per srl item No. 63 here in beore but 70 Sqmm 3.5 core
All as per srl item No. 63 here in beore but 50 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5 m wide and n exc 1.5 min depth for in soft loose soil for poles stay, cables, pipes etc getting out all as specified
Returning filling in including spreading levelling watering and well ramming in layers nexc 25 cm thick in soft loose soil all as specified
Removal of excavated surplus/spoil on a distance n.exc 50 m and deposting where directed at a level n.exc 1.5 m above the starting point all as specified
Supply and lay brick common burnt sub class "B" old size for protection of cables laid in trenches all as specified
M & L for Sand cushioning trenches using fine sand to under ground cable all as specified and directed.
M & L for Earthing complete with galvansed steel earth plates electrode 60cmX600cmX6mm thick burried directly in ground ( earth pit not less than 2.25 mtr deep below the ground level ) with edge of the plate not less then 1.5 mtr below the ground level connection to GI galvanised Iron strp 25mmX4mm as earthing lead by means of bolts/nuts chick nut & washers of GI or steel all ghown in electrical plate No 5 of SSR part I connection to feeder piller all as specified including watering GI pipe 40mm bore medium grade PCC chamber using PCC 1:3:6 type C2 and PCC C1 for cover funnel & wire mesh all as specified & directed by Engr-in-charge
Supply only copper sulphate of approved make by HQ E-in-Cs Branch.
Supply only Soda ash made of 100% sodium cabonate make Tata Chemicals/Grasim / Approved ISI brand.
supply only Chlorine test kit with coloured sample complete with all testing fitments and OT solution in suitable box make CHLOROMAX or equivalent and approved.
M & L for water suction PVC hose pipe 50mm. Make :- deep/ jyoti
M & L for nylone rope 25mm dia of approved quality all as directed
Supply only Alum ferric white (Crystal type) Make :- As per approved make by HQ E-inCs Branch.
Supply only bleaching powder Gde-ll confirming to IS-1065/89 revised with minimum chloride available 33.3% packed in 25/50 kg tight screwed bags complete all as specified and directed. Make : As per approved make by HQ E-in-Cs Branch.
Comprehensive Maintanance of stretcher lift at 172 Mil Hospital , Tibri of Make: OTIS ,including periodical inspection and servicing, replacement of minor defective parts, safety test etc complete all as per manufacture's offer all as directed by Engineer-in-charge Note :- Comprehensive maint includes all type of minor repair works to be carried out to make the lift smoothly functioning at all the times. Routine maint to be carried out minimum once in a month. failing which a penalty of Rs 5000/- will be levived on the contractor. In case of any breakdown the complaint to be attended withing 24 hours of time frame, failing which a penalty of Rs 100/- per hour will be levived on the contractor.
Supply and fixing in repair of Car ceiling for BED Elevator of Lift installed at 172 MH all as directed
Supply and fixing in repair of Electronic door protection complete kit all as directed and specified
M & L for fixing in repair of Infrared Sensor of Closing and opening of Door by dismantling the old one all as directed
M & L for LT Panel repari incluidng wiring of the Lift Panel upto the Header of the lift door with control wiring and repalcement of the defective parts of the panel including contactors, timer, phase preventor, relay etc and testingof the panel for improved performance all as directed by the Engineer In charge
Supply and fixed in repair electronic hooter industrial type of range 5 KM single phase 230 volt ,6000 RPM aluminium body completeall as directed and specified
Supply and fixing in repair of suction sweeper including electric motor of 3 HP capacity 440 Volt 50 Hz with a head of min 20mtr including suction header, suction provision, electric cable, angle iron frame and wheel for heavy and extensive uses all as directed by Engineer-in-charge. Contractor has to provide written gurantee for one year for the suction sweeper for smooth functioning.
M & L for Repair / serviceing of DOL Starter of pump motor of capacity 15 HP swimming pool including replacement of burnt items, defective parts etc all as directed by engineer-in-charge
M & L for Disconnecting and taking out pump motor of capcity 10-15HP from existing position, dismantaling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including insulation material cotton tape, varnish , insulation paper, sleevs, lugs etc and testing for improved performance as per the satisfactio of Engineer-in-charge
Supply and fixing in replacement of Nylon brush of superior quality for suction sweeper machine of existing size directed by Engineer in charge
Supply and fixing of PVC pipe corrugated type as per existing of size 40/50mm dia all as directed by Engineer In charge
Supply and fixing of pressure gauge of range 0 to 100 Kg/CM2 of existing make all as directed by Engineer in Charge
supply and fixing of CI fittings including Tee, bends, nippel, coupling etc all as directed
M & L for cleaning of UG sump of capacity 50000 Gallons (Swiming pool collection sump) as described below ):- (i) Dewatering with submersible / sludge pump to empty the sump tank upto base level (ii) Removing sludge from sump wall and bottom with the help of special sledge pump and remaining dirt which may have hidden in rogh slots of the bottom mannually with brush (iii) After cleaning the sump apply bleaching powder for disinfection of sump (iv) The sludge / waste removed from the sump shall be disposed off in dumping ground as directed by Engineer - in - charge
M&L for fixing of air termination single pointed aluminium rod,30 CM long of dia 12mm including insulators completeall as directed and specified
Supply and fixing in repair aluminium strip 25mmx3 mm complete with saddle and fixing screws for fitting strip.
Supply and fixing in repair GI strip 32mmx6mm complete with saddle and fixing screws for fitting strip.
Supply and fixing in repair test point terminal block made of GI plate size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex.head screw all as specified and directed
Supply and fix in repair installaton commissioning and testing of All in One solar street lighting system complete with solar Panel, with IP 65 protection, solar panel, battery, charging circuit, LED driver are integrated in single casing, mounted on existing pole, connecting cable battery box reflector on its back including LED light of 40 W and above, Aluminum alloy case, built in pipe mounting bracket, 120degrees wide lighting angle, efficiency min 95% make : Bajaj/Halonix/Philips/Crompton/Havells
Supply and fixing in replacement of flat submersible electric cable,spl PVC insulated, with bare bunched copper conductor for submersible pump,1100 volts grade, 3 core, cross sectional area 6 sqmm.
All as per Srl item No 99 here-in-before but cross sectional area 10 sqmm all as directed
S & F MCCB 250 Amp 25 KA 415 volt FP adjustable thermal& fixed Magnetic setting all as directed and specified by Engineer in charge
S & F MCCB 160 Amp 25 KA 415 volt TP adjustable thermal& fixed Magnetic setting all as directed and specified by Engineer in charge
S & F MCCB 100 Amp 16 KA, 415 volt FP fixed Magnetic setting all as directed and specified by Engineer in charge
S & F MCCB 63 Amp 16 KA, 415 volt FP fixed Magnetic setting all as directed and specified by Engineer in charge
S & F Isolator 4 pole 63 Amps in the panel of sewage motor panel all as directed and specified by Engineer in charge
Supply & fixing Digital type Volt meter 0 to 500 volts LED Display with slector switch complete all as directed and specified
Supply & fixing Digital type Ampere meter 0 to 100 Amp LED display slector swtich complete all as directed and specified
Supply and fix in repairs CI sluice valve with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 100mm dia bore with hand wheel.al as directed.
Supply & fixing in repair CI Non return valve forged brass 100 mm bore PN 1.6 complete with flanged on both ends all as directed and specified
Supply & fixing in repair 50mm dia cast iron air realease valves with single air outlets, confirming to IS - 14845 complete all as directed and specified
M & L for painting of the whole chimney of the incenerator by scrabing out the old paint and preparing the surface for new painting, applying one coat of red enameled paint and two coat of sliver colour glosy paint heat resistance type paint, scrubing out the old paint of existing primary, seconday chember, ID Fans, Motors, Sign boards, Pipes, Angle Irons, Channels etc and applying two coats of Alluminium paint with all colour coads as described by Engineer iin charge with the full satisfaction all as dircted and specified
M & L in repair 3 pole power contractor MNX - 45 of make L&T or equivalent all as directed by Engineer - in - Charge
M & L in repair 3 pole power contractor MNX - 25 of make L&T or equivalent all as directed by Engineer - in - Charge
M & L in repair 3 pole power contractor 3TF 35 of make Siemens or equivalent all as directed by Engineer - in - Charge
M & L of overload relay of range 15-25 Amps capacity all as directed by Engineer in Charge
M & L in repair of overload relay of range 30-50 Amps capacity all as directed by Engineer in Charge
M & L in repair of 3 phase Timer, 230 Volt, 50 Hz, Amps 15 upto 50Amp capacity all as directed by Engineer in Charge
M & L in repair of single phase preventor 230 Volt, 50 Hz all as directed by Engineer in Charge
Supply and fixing in replacement of push button of Red, green, and exiting colour 230 Volt all as specified and directed
M & L in repair 3 pole power contractor model TC1D2510 of make Siemen or equivalent all as directed by Engineer - in - Charge
M & L for attending of complaints of non working of sewage pump, motors, defects in pump motor panel with minor defects rectification whenever arises, the mechanic / electrician should visit the site and rectify the minor defects in panel and pump motor if there in respect of non operation of pump due to phase change, tripping , terminal burnt etc all as directed by engineer in charge NOTE: All T&P and manpower will be provided by contractor. The repair of work should be carried out within 48 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 48 hours failing which a penalty of Rs 1000/- per days will be levived on the contractor.
Taking out, dismantaling the Servo Voltage Stabilizer from foundation and transporting the same to workshop, taking out of all burnt winding wires by strip opening of 3phase voltage stabilizer of any make, rewinding the stabilizer with super enamled copper winding wire of required gauge and quantity including varnishing insulation sheet cotton, glass sleave etc as required, reassembling,testing, transporting back to site from workshop, installing back and making connection and again testing for 100 KVA Servo Voltage Stabillizer for improved performance all as specified and directed by Engineer in Charge Note :- Winding wire, Transformer oil will be measured and paid under relevent items.
Material only Copper winding wire of different gauge and size for servo voltage stabilizer, alternator rewinding and other works as directed by Engineer in charge
Supply only in replacement of Transformer Oil for voltage stabilizer all as directed by Engineer In charge
Supply and fixing in repair of chain pully block of 5 Ton capacity industrial type heavy duty all as specified and directed
M & L for cleaning of UG sump of sewage collection sump of capacity 50000 Gallons (Sewage collection sump) as described below ):- (i) Dewatering with submersible / sludge pump to empty the sump tank upto base level. (ii) Removing sludge from sump wall and bottom with the help of special sledge pump and remaining dirt which may have hidden in rogh slots of the bottom mannually with brush. (iii) After cleaning the sump apply bleaching powder for disinfection of sump. (iv) The sludge / waste removed from the sump shall be disposed off in dumping ground as directed by Engineer - in - charge
Disconnecting and taking out motor from non clog sewage pump horizontal type 65 LPS, 30 mtr head 3 phase 440 volt including pump, dismantaling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton tape, varnish , insulation paper , sleeves and dry & baking etc connections etc and assembling complete after duly repair installation, commisioning and testing upto the satisfactory working performance complete all as specified and directed. NOTE: All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs 2000/- per days will be levived on the contractor.
S&F in replacement of Impeller bronze sutaible for sewage pump horizontal type 65 LPS, 30 mtr head 3 phase 440 volt pumping set complete all as specified.
S&F in replacement of Ball Bearing as per sample for sewage pump horizontal type 65 LPS, 30 mtr head 3 phase 440 volt for both side front and rear side bearing of existing size etc complete all as specified.
Disconnecting and taking out motor from non clog sewage pump horizontal type 45 LPS, 30 mtr head 3 phase 440 volt including pump, dismantaling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton tape, varnish , insulation paper , sleeves and dry & baking etc connections etc and assembling complete after duly repair installation, commisioning and testing upto the satisfactory working performance complete all as specified and directed. NOTE: All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs 2000/- per days will be levived on the contractor.
S&F in replacement of Impeller bronze sutaible for sewage pump horizontal type45 LPS, 30 mtr head 3 phase 440 volt pumping set complete all as specified.
S&F in replacement of Ball Bearing as per sample for sewage pump horizontal type 45 LPS, 30 mtr head 3 phase 440 volt for both side front and rear side bearing of existing size etc complete all as specified.
S & F in repair fully automatic star delta starter (FASD) suitable for 10-15 HP motor all as specified and directed by Engineer in charge
S & F of PVC Sheathed cable 3 core 16 sqmm copper conductor for connection the sewage pump from panel all as specifie and directed
Supply and installation in repairs of monoblock pump set with electric driven motor, single phase, 230 Volts, 2800 RPM, 01/0.7 KW having suction and delivery 25mm x 25mm all as specified and directed
Supply and fixing in repair of Battery charger of 12 Volt 30 Amp capacity for charging mimimum 4 batteries at a time all as specified and directed by Engineer in charge
Supply and fixing in replacment of steel hinges of Canopy type DG Set of all type and capacity all as directed by Engineer in Charge
M&L for repair of leakages GI pipe of size 20 mm by replacing the Tees, bends, sockets unions etc complete including all acessories with necessary exacavation and earth work; returning filling & removal for that job, dewater arrangement is contractors responsibility all as specified and directed by Engineer-in-Cahrge. Note :- one supervisor should report to JE in charge on daily basis with complaint register. The minor complaints should be done by 24 hours of time and major complaints within 48 hours of time frame. Failing which 200/- per day will be levived from the contractor as penalty. The contractor will arrange the security passes for himself/supervisor and his work force as per the existing security of the station without any extra cost.
All as per item srl No 138 here in before but size 25mm bore.
All as per item srl No 138 here in before but size 50mm bore.
M&L for repair of leakages of CI/DI pipes of size 80 mm by replacing the Tees, bends, sockets and providing the other materials required at site such as lead joint, to complete the job including excavation and other earth work. Note :- CI/DI bends, sockets,Y juction,cross,collars,cap,lead joint/tighten joint and connected items will be measured and paid separately
All as per item srl no 141 here in before but size 100mm bore.
All as per item srl no 141 here in before but size 150mm bore.
Material and labour for ISI marked CI/DI pipe fittings up to size 80 to 150 mm dia such as bends, Tapers tail pieces, Tee pieces , dummy plates, clamps to block leakages, caps and plug set including rubber ring push on joints complete as specified and directed
Taking out existing 20mm GI pipe lines for relaying /refixing at site existing/connected all as directed .
All as per item srl no 145 here in before but size 25mm bore.
All as per item srl no 145 here in before but size 50mm bore.
All as per item srl no 145 here in before but size 80mm bore.
S & F in repair of GI tubing , medium grade, galvanised, with all fittings, laid in trenches of size 20mm bore all as directed.
All as per item srl no 149 here in before but size 25mm bore.
All as per item srl no 149 here in before but size 50mm bore.
All as per item srl no 149 here in before but size 80mm bore.
M & L for repair of All in one solar street light of capacity 40 Watt including replacement of defective Solar Panel, unserviceable wiring circuit, LED light panel etc and checking of the solar light for complete functioning all as specified and directed by Engineer in Charge
Supply & fixing in replacement of float switch N1 10 Mtr for sewage pump including electric connection complete all as specified and directed
Surface dressing n. exc 15 cm deep of soft/loose soil site clearance ground STP installations area complete all as specified and directed by Engr in charge. Note :- leveling of the disturbed will be done by tractor or other equivalent by the contractor.
Supply and spraying glyphosate 41% SL Glykol Herbicide to remove vegatation from STP Installation area including T&P required for spraying complete all as specified and directed by Engr-in-Charge
Note: A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
P S BUILDERS (BID ID -3056171)
kailu construction co (BID ID -3064942)
satpal and brothers (BID ID -3065313)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .