Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
23 Feb 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Construction of 24x7 PHC Building at Mahimunda of Puintala Block under National Health Mission in the Bolangir district of Odisha (Scope of work in addition to above is uploaded separately along with this NIT)
NBCC/ODISHA/ZO/NHM/NIT/22-23/003
NBCC/ODISHA/ZO/NHM/NIT/22-23/003
Open Tender-Domestic
Civil Works General
Balangir, Odisha
₹11,800
₹2.0 L
23 Feb 2023
8 Feb 2023
23 Feb 2023
23 Feb 2023
9 Mar 2023
Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6
stone agregate 40mm nominal size) as levelling course in foundation and
plinth etc. including tempering, curring, shuttering etc. complete all depth
Supplying all materials, labour, T&P and providing cement concrete (1:2:4)
with 12mm size hard granite chips including watering, curing, conveyance
of all materials to worksite, payment of royalty, taxes etc all complete as
per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing Pidifin 2K including
conveyance of all materials to worksite, payment of royalty, taxes etc all
complete as per specification and direction of the Engineer in charge
Factory made single leaf solid WPC (wood polymer ) composite door
shutter of 25mm thick compacted with wood grain finish structural foam
paner of 29mm thickness and a density of 20kg/cu.mtr shall be used as
core material for fitting the metal fittings such as tower blits,aldrops,
handles etc shall be provided. A structural adhesive compatible with (EPS)
foam shall be used for bending the core material ,The material and
173 7 process for manufacturing the door shutters shall confrom to RV-TIFAC 0 0.00 0.00 0.00
composites design centres standards and specification and the door
shutters conforming to relevant I.S. specification . The finish of door shutter
will be plain colour white /lvory/beige/light grey/mahogany/Teak wood or
any other colour using high quality pigmments. Three heavy whight mild
steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one
side of shutter.
Factory made solid WPC door frame of size 95mmx55mm fabricated .The
door frame consist of four segments which are provided with plug-in-socket
arrangement in-situ in the mould. The segments are plugged in and are
joined together by means of screw . The WPC frame shall be provided with
the material and process for manufacturing the door frames shall conform
to relavent I.S Specification. the finish of door frame will be plain colour
white /lvory/Beige/light grey/Golden brown/mahogany/Teak wood /sand
stone/Champagne/pastel blue of any other colour using high quality
pigments complete in all respect as per specification and direction of the
engineer in charge.
177 B.ii EXTERNAL P.H. & SANITARY WORK. :- 0 0.00 0.00 0.00
Supplying all materials, labour, T & P and constructing Gully trap chamber
of the following inside size with 8 cm thick R.C.C. precast cover slab in CC
(1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using
40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in
P&F and inside 12mm thick cement plastering (1:3) finished with a floating
coat of neat cement including fixing 100mm x100mm size gully trap,
150mm x150mm C.I gratig etc. all complete as per aproved drawing,
specification and direction of Engineer-in-charge.
179 0 250mmx250mm with RCC cover Each 8.00 1456.24 11,649.90
Supplying all materials, labour, T & P and constructing Inspection chamber
of the following inside size with CC (1:3:6) mix using 40mm size h.g. metal
on bed, Ist class Fly Ash brickwork in CM (1:6) , moulding and shaping the
channel inside and benching with CC (1:2:4) using 12mm size h.g. chips,
12mm thick cement plastering (1:3) finished with punning to inside ,
180 2 cement flush pointing (1:3) to outside , R.C.C. cover slab in (1:2:4) using 0 0.00 0.00 0.00
12mm size h.g. chips with RCC man hole cover , earth work in excavation
in all kinds of soil and refilling the cavity around the chamber including
watering ,curing, conveyance of all materials to worksite , payment of
royality , taxes etc. all complete as per aproved drawing , specification and
direction of Engineer-in-charge.
181 0 Inside size 760mm x760mm x450mm Each 6.00 10296.68 61,780.08
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and laying in trenches (to level or
slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the
following outside dia for class-3(0.60mpa) including jointing with supply of
approved solvent cement by non-heat application method/as per
182 3 manufacturer’s specification, providing and laying in trench cement 0 0.00 0.00 0.00
concrete (1:4:8) with 40mm size hard granite metal in the Type C-1
standard bedding surrounding or encasing including concrete for bedding
and curing etc all complete as per PH specification and direction of the
Engineer-in-charge.
183 a) 110mm dia u-pvc pipe alround concrete mtr 60.00 1301.66 78,099.48
184 b) 160mm dia u-pvc pipe alround concrete mtr 60.00 2157.63 1,29,457.80
Supplying all materials, labour, T&P and constructing Man hole chamber of
the following size with cement concrete (1:3:6) using 40 mm size HG
metal on bed , !st class Fly Ash Brick work in CM (1:6) moulding and
shaping the channel inside and benching with CC (1:2:4) mix using 12 mm
size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside,
185 4 cement flush pointing (1:3) to outside ,RCC cover slab in (1:2:4) mix using 0 0.00 0.00 0.00
12 mm size H.G chips with RCC man hole cover , earth work in all kinds of
soil and refilling the cavity around the camber including watering, curing,
conveyance of all materials to worksite payment of royalty, taxes etc. all
completed as per approved drawing, specification and direction of
Engineer-in-charge.
186 a) Inside size 900mmx900mmx900mm each 5.00 19311.29 96,556.45
187 b) addl depth of 0.30m upto 4.50m depth each 3.00 2051.08 6,153.23
Supplying all materials, labour, T&P and constructing soakway pit of the
following size with precast RCC rings joined loose, gravel backing in the
rear of well steining, precast RCC cover slab in cement concrete (1:2:4)
using 12mm size hg chips fitted with iron lifting handles including cutting
188 6 hole in the rings for inlet pipe,earthwork in open well excavation in all kinds 0 0.00 0.00 0.00
of soil and refilling of cavity around the pit & painting the iron works,
watering, curing, conveyance of all materials to worksite, payment of
royalty, taxes etc all complete as per approved specification and direction
of the Engineer-In-Charge
189 a) RCC rings soakway pit 1.8m dia x 2.6m deep each 1.00 23328.36 23,328.36
Construction of 1 No production wells including scientific source finding
through consolidated and unconsolidated rock with down the hammer
drilling rig or combination rig with PVC pipe and installation of submersible
pump set with all acessories
Labour for drilling a perfectly vertical bore hole of specified dia for a
specified depth below ground level through consolidated and
unconsolidated rock with down the hole hammer drilling rig or combination
rig as required to suit the site condition as per the direction of the Engineer
in charge including use of own rig with its accessories, tools and plant and
consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing
192 0 pipes for housing fitted with socket and with or without well screen as per 0 0.00 0.00 0.00
the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S
casing pipes if required to prevent collapse of overburden is to be provided
by the contractor including lowering and withdrawing after completion of
the tube well), 200mm dia to 400mm dia in overburden portion including
packing of gravel supplied by the contractor for 400mm dia bore only
193 0 Drilling of 200mm dia bore 0 0.00 0.00 0.00
196 4 Drilling of 150mm dia bore 0 0.00 0.00 0.00
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without
slotted pipes as per the necessity from ground level up to 45.00m depth
and fitted and fixed up in perfectly vertical position including cutting and
198 5 threading of pipes and slotted pipes and supplying and fixing all jointing 0 0.00 0.00 0.00
materials, tools and plant etc all complete and keeping the top of casing
pipe threaded including plugging tube wells to prevent entry of foreign
199 6 Lowering of 200mm dia P.V.C casing pipes 0 0.00 0.00 0.00
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads
in accordance with DIN 2999 part-1/DIN-42225 part-II specification length
of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both
external and threaded with free socket. The pipe having external thread at
one end i.e female and or belled end. The female end having internal
202 8 thread is to be belled in order to accept the male end while jointing pipes 0 0.00 0.00 0.00
with a bore threading shall be provided with a greave at the roof of the
male thread accomodate flexible PVC/Rubber 'O' ring to make the joint
water tight colour of the pipe shall be blue. The name of the manufacture
along with batch No class of pipe shall be stranded legibly of each pipe
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and providing and providing sanitary
sealing by cement concrete grouting of annular space around GI/PVC/MS
housing pipe upto 5m below ground level (as per drawing) to plug the bore
204 9 hole excluding cost of cement all complete as per direction of the Engineer Each 1.00 1384.26 1,384.26
in charge. Minimum one metre of casing pipe to be inserted in the bore into
the rock at the bottom to ensure sanitary sealing (excluding cost of cement
which will be supplied directly by the department)
Cleaning and developing the tube well with supply of compressor worked
till clear and adequate discharge is obtained from the tube well including
supply and use of all necessary equipment and labour as per direction of
the Engineer in charge
Supplying all materials, labour, T&P and providing, fitting and fixing
submersible pump with squirrel cage induction type submersible type
submersible electric motor to run on 3 phase/1 phase line voltage ranging
from 320 volt to 450 volt conforming to IS: 8034/89 with following
207 11 specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, 0 0.00 0.00 0.00
electrification, testing, commissioning, trial running, conveyance of all
materials to worksite, payment of taxes etc all complete as per
specification and direction of the Engineer in charge (Texmo/Crompton
Greaves/Kirloskar make)
2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with
208 0 discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% Each 1.00 19618.21 19,618.21
209 12 DOL Control panel Each 2.00 4490.49 8,980.98
210 13 40mm dia steel short piece Each 2.00 238.36 476.72
212 15 50mm size CI bracket Pair 1.00 107.73 107.73
214 17 20mm dia rigid UPVC pipes Mtr 35.00 8.14 284.97
215 18 Steel rope with cover Mtr 35.00 31.51 1,102.71
216 19 Labour charges for lowering including transportation Each 2.00 2360.00 4,720.00
Supplying all materials, labour, T&P and providing and fixing to wall or
ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000
(10kgf/sqcm) of the following nominal bore with clamps and jointing by
Fusion welding method including testing, making good the wall, ceiling
and floor all complete as per specification and direction of the Engineer in
218 0 32mm HDPE pipes (Finolex/Supreme make) mtr 85.00 117.76 10,009.94
219 B.ii SEPTIC TANK. (50 USER) 0 0.00 0.00 0.00
Earthwork in excavation in all types of soil for site leveling, foundation, pits,
trenches and other civil works up to and including 1.5 metre lift and
220 1 stacking the soil upto a lead of 100 metre and including dewatering, Cum 15.75 259.36 4,084.98
removing slush, shoring and strutting (as required), complete as per
specification and as directed by the Engineer-In-Charge.
Filling at all depth with available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not exceeding 15 cm in
depth : consolidating each deposited layer by ramming and watering
complete (lead upto 100m) as directed by the Engineer-In-charge.
Supplying of filling sand in foundation and over areas including watering,
222 3 ramming, consolidating and dressing, labours, tools, taxes etc. all Cum 1.40 335.24 469.33
complete as per the specification and direction of E.I.C.
Providing and laying plain cement concrete 1:3:6 (1 cement:3 sand: 6
stone agregate 40mm nominal size) as levelling course in foundation and
plinth etc. including tempering, curring, shuttering etc. complete all depth
Supplying all materials, labour, T&P and providing cement concrete (1:2:4)
with 12m size hard broken granite chips including watering, curing,
conveyance of all materials to worksite, payment of royalty, taxes etc all
complete as per specification and direction of the Engineer in charge
Providing, lifting, hoisting and laying Reinforced cement concrete of M-250
grade as per approved designs and drawings having a minimum
compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes
at 28 days after mixing and test conducted in accordance with I.S. 516
using 12 mm. to 20 mm. size black hard crushed broken granite stone
chips and screened and washed sharp sand for mortar of approved quality
from approved quarry, washed and cleaned ( 20mm. size chips not to
exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement
(PSC) including hoisting, lowering, laying and compaction concrete by
225 6 using vibrators, watering and curing for 28 days, centering and shuttering 0 0.00 0.00 0.00
then after dismantling and removing debris from the work site and finishing
the exposed surface smooth providing grooves or beads wherever
necessary including cost, conveyance, loading, unloading, royalties and
taxes of all materials and cost of all labours, sundries, T & P required of the
work etc. complete in all respect as directed by the Engineer-in-Charge.
But excluding cost and conveyance of M.S. rods or Tor steel and binding
wires and labour charges for straightening, cutting, bending etc. of M.S.
rods or tor steel tying the grills and placing in proper position.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying, straightening, cutting, bending, placing in position and binding
reinforcement steel work in RCC/reinforced brick works as per drawing and
specification including preparation of respective bar bending schedule and
binding (Binding wire to be used as per the IS code) etc. all complete as
per direction of Engineer-In-Charge.Cold Twisted bars, Thermo-
Mechanically-treated bars.
230 8 Fly Ash bricks Masinary (1:6) (in F & P). Cum 1.20 5340.56 6,422.56
12mm cement plaster on internal smooth side of RCC/brick surfaces with
cement mortar of mix 1:4 (1 cement : 4 fine sand) including neat cement
punning & necessary scaffolding, curing etc. all complete at all floors and
Providing 16mm. thick cement plaster in all floors at all height with cement
mortar of mix (1:6) with OPC 53 grade cement finished smooth to inside
smooth surface of brick masonry walls after racking out the joints including
watering and curing, rounding of corners etc. complete with cost,
coveyance, loading and unloading, royalties and taxes of all materials and
cost of all labours, sundries, T&P and scaffolding required for the work etc.
complete in all respect as desired by the Engineer in charge.
Supplying all materials, labour, T&P and providing , fitting & fixing 100mm
x100mm x100 mm SW Tee in wall including filling the recess with cement
233 11 concrete (1:3:6) with 12mm size h.g chips all complete including watering, Each 2.00 365.45 730.89
curing, conveyance of all materials to worksite, payment of royalty all
complete as per specification and direction of the Engineer in charge.
Supplying all materials ,labour, T&P and making MS STEP IRON IN 20MM
diameter MS steel bars & fixing into walls of man hole/septic tank duly
embedded in cement concrete (1:3:6) complete as per specification and
direction of the Engineer in charge.
235 0 Sub-Total of Plumbing Works 2817568.169
236 0 Electrical Works 0 0.00 0.00 0.00
Recessed wiring to light point / first light of group control/ call bell point/
exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated
single core multistrand copper conductor of ISI marked in 20 mm dia non-
metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and
ceiling rose ISI marked mounted on G.I modular box with face plate &
cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core
multistrand copper conductor as earth wire including all accesories and
connection as per direction of Engineer in Charge. (Make of wire Finolex
/Polycab/ Anchor / Havels/Eq) (Make of modular box,cover,switch & socket-
Legrand Myrios/schneider opale/Eq) With 10Years Warenty
Recessed wiring to secondary light point looped from primary light point
with 1.5sqmm FRLSH PVC insulated single core multistrand copper
conductor of ISI marked with 20mm dia non-metallic PVC conduit with
239 2 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor Nos. 30.00 639.56 19,186.80
for running earth including 3 plate ISI marked Ceiling rose with all
accessories & connection as per direction of Engineer-in-charge. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq) Average Length: 3 mtr
Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated
single core multistrand copper conductor of ISI marked with 20mm dia non-
metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type
240 3 Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated Nos. 50.00 2756.48 1,37,824.00
single core multistrand copper conductor for running earth including all
accessories & connection as per direction of Engineer in charge. (Make of
wire Finolex /Polycab/ Anchor / Havels/Eq) Group B
Recessed wiring to Twin control light point with 1.5 sq.mm FRLSH PVC
insulated single core multistrand copper conductor of ISI marked in 20 mm
dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI
marked and ceiling rose ISI marked mounted on G.I modular box with face
plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated
single core multistrand copper conductor as earth wire including all
accesories and connection as per direction of Engineer-in-charge. (Make
of wire Finolex /Polycab/ Anchor / Havels/Eq) Group C
Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type
modular switch ISI marked mounted on G.I moular box with face plate &
cover of suitable size including all accesories and connection on same
switch board as per direction of Engineer-in-charge.
Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH
PVC insulated single core multistrand copper conductor of ISI marked in
20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch
ISI marked mounted on G.I moular box with face plate & cover of suitable
size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand
copper conductor as earth wire including all accesories and connection on
separate board as per direction of Engineer-in-charge.(Make of wire
Finolex /Polycab/ Anchor / Havels/Eq) Group C
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp,
250 V clip in type switch ISI marked mounted on single G.I moular box
244 7 with face plate & cover of suitable size including all accesories and Nos. 25.00 1957.62 48,940.50
connection on separate board as per direction of Engineer-in-charge.
Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in
type switch ISI marked mounted on G.I moular box with face plate & cover
246 8 of suitable size including all accesories and connection as per direction of Nos. 5.00 1425.44 7,127.20
Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard.
Recessed wiring for A.C/ Power socket outlet with industrial type socket
outlet, plug top and metal chained cover in sheet steel enclosure
,20A/32A SP MCB including all accesories and connection as per direction
of Engineer-in-charge.
Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC
insulated single core multistrand copper conductor of ISI marked with
20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,
248 10 Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand Nos. 13.00 1569.40 20,402.20
copper conductor for running earth including all accessories & connection
as per direction of Engineer in charge. (Make of wire Finolex /Polycab/
Anchor / Havels/Eq) Group C
Recessed wiring for 3 x 6 amp socket outlet controlled by 2 nos 6Amp,
250 V clip in type switch ISI marked mounted on single G.I moular box
250 12 with face plate & cover of suitable size including all accesories and Nos. 1.00 1248.44 1,248.44
connection on separate board as per direction of Engineer-in-charge.
Recessed wiring to submain in 4 x 10 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked confirming to IS-694/1990
in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with
2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper
conductor as earth wire as equired. (Make of wire Finolex /Polycab/
Anchor / Havels/Eq)
Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked confirming to IS-694/1990
in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with
1 x 4 sq.mm FRLSH PVC insulated single core multistrand copper
conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor
Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked confirming to IS-694/1990
in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with
1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper
conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor
Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked confirming to IS-694/1990
in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with
1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper
conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor
Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single
core multistrand copper conductor of ISI marked confirming to IS-694/1990
in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with
1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper
conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor
/ Havels/Eq) (For Switch Board Looping)
Supply and fixing of following way three pole and neutral, sheet steel, MCB
distribution, 415 V on surface / recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the
MCB knobs detachable gland plate, interconnections, phosphatized and
powder painted including earthing etc. as required wih necessary MCB ,
RCCB / ISOLATORS as required.Note for MCB- There should be colour
indication for tripping On ,Off & Trip/There should be mid trip position for
toggles for electrical fault conditions.(With 5Years Warenty)
Supply, fixing, erecting, connecting and commissioning of indoor type dust
and vermin proof, sheet steel clad ready made, double door horizontal type
powder coated wall mounted 4 way TPN Distribution Boards For PDB
260 a) suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with Nos. 2.00 14026.66 28,053.32
bottom detachable plate for interconnections etc as below.Incommer 1 No-
63A FP MCB (10KA) Outgoings-10/20A SP MCB 10KA-12Nos.(Make-
L&T/ Schneider/Legrand/Eq)
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply, fixing, erecting, connecting and commissioning of indoor type dust
and vermin proof, sheet steel clad ready made, double door horizontal type
powder coated wall mounted 12 way SPN Distribution Boards For LDB
261 b) suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with Nos. 2.00 10694.34 21,388.68
bottom detachable plate for interconnections etc as below.Incommer 1 No-
40A DP MCB (10KA) Outgoings-10A SP MCB 10KA-10Nos.(Make-L&T/
Schneider/Legrand/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE
power cable of 1.1 KV grade of 3.5core 50 sq.mm direct in ground
including excavation , sand cushining protective covering and refilling the
trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE
power cable of 1.1 KV grade of 3.5core 35 sq.mm direct in ground
including excavation , sand cushining protective covering and refilling the
trench etc. as required.(Make-polycab/RR Kable/Rhino cable/Eq)
Supply & Laying of one number of PVC insulated and PVC seathed / XLPE
264 21 power cable of 1.1 KV grade of 4 core 16 sq.mm Aluminium on surface as Rmt 35.00 370.52 12,968.20
required.(Make-polycab/RR Kable/Rhino cable/Eq)
265 0 END TERMINATION 0 0.00 0.00 0.00
Supplying and making end termination with brass compression gland and
266 0 aluminum lugs for following size of PVC insulated and PVC sheathed / 0 0.00 0.00 0.00
XLPE aluminum cable of 1.1 KV as required.
Supply, installation,testing & commissioning of floor mounting front
operated front access extensible type cubicle panel totally enclosed, dust
and vermin proof with IP-42 /55 protection with hinged and lockabale
doors.CRCA sheets including interconnections,tinned copper crimping
lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire
50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec
at 415 V complete as per specifications, as required and as below : All
switchboards shall have provision for entry of cables from the bottom as
required. All live accessible parts shall be shrouded and all equipment
shall be finger touch proof. The bus bars shall be insulated with heat
shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used
with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control
fuse etc. complete.MAKE- Legrand / Schneider/ L&T/SIEMENS/Eq.
MAIN PANEL with 100A 4P MCCB 25KA -1 No as incomer,125A 4P C.O.
SWITCH 1Nos,63A 4P MCB 10KA 4Nos.63A 4P C.O. SWITCH 1Nos, 40A
DP MCB 10KA 3Nos, with E.C Busbars with 4nos 65KA VSD along with
4nos 32A SP MCB.
EXT Light DB with 63A 4P MCB (10KA) -1 No as incomer, 1Nos Timer
273 26 Switch ,20A SP MCB 10KA-12 Nos, 20A DP MCB 10KA 6Nos. as Outgoing set 1.00 32243.50 32,243.50
with E.C Busbars .
PUMP Panel Board with 63A 4P MCB (10KA) as Incomer , Outgoings-
274 27 32A 4P MAB 10KA-2Nos, 20 A DP MCB 10KA-3Nos, with E.C Busbars. set 1.00 24335.14 24,335.14
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI
marked including accessories and providing masonary with cover plate
having loccking arrangement and watering pipe etc with charcoal and salt
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5
277 29 meter below ground level as strip earth electrode including soldering etc. Rmt 35.00 1262.60 44,191.00
Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface
or in recess for connection etc as required.
Providing and fixing 8 SWG CU wire on surface or in recess for loop
earthing as required.
280 32 Lightning Protection System. 0 0.00 0.00 0.00
281 (a) Supply & fixing of lightning arrester ABB ESS Type. Nos 1.00 370971.94 3,70,971.94
Earthing with 50mm dia 3mtr long cupper With 2nos compoung (25kg) as
Supply, Installation, Testing and Commissioning of pre-wired fluorescent
fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all
accessories and lamp etc. directly on ceiling /wall or recessed in false
ceiling , including connection with 1.5 sq.mm FR PVC insulated single core
multistrand copper conductor and earthing as required.Make-
Bajaj/philips/wipro/JAQUAR/Eq.With 5Years Warenty.
285 33 Ceiling mounted indoor type 24w batten type LED Luminaire Nos 76.00 644.28 48,965.28
286 34 Ceiling/ Wall mounted type 10w BULK HEAD Luminaire Nos 5.00 1465.56 7,327.80
287 35 Supply, Installation, testing and commissioning of 10W Mirror Light Nos 8.00 365.80 2,926.40
Supply, Installation, Testing and Commissioning of ceiling fan 1200mm
sweep USHA ENERGIA, including wiring the down rods of standard length
(upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand
copper conductor etc. as required.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply, Installation, testing and commissioning of exhaust fan of 230 mm
sweep AEROCLEAN LD GBD 900 rpm in the existing opening, including
making the hole to suit the size of the above fan, making good the damage
complete, connection, etc as required.
290 38 Supply & fixing of 15W LED Down Light (Surface/Recessed) Nos 25.00 1500.96 37,524.00
291 39 Supply & fixing of LED 36w 2'x2' Surface/Recessed Mounted Light Nos 10.00 3600.18 36,001.80
Supplying and fixing of clip in type modular Telephone socket ISI marked
mounted on G.I modular box with face plate & cover of suitable size
,including all accesories and connection as per direction of Engineer in
Supplying and fixing of clip in type modular T.V. antenna socket ISI
marked on mounted on G.I modular box with face plate & cover of suitable
size , including all accesories and connection as per direction of Engineer
Supplying and drawing 4 pair, 0.5 sq.mm FR PVC insulated coper
296 42 conductor, unarmoured telephone cable in existing surface / recessed Rmt 100.00 53.10 5,310.00
PVC conduit as required.
Recessed wiring to television point with cable RG-6 grade, 0.7 mm solid
copper conductor PE insulated shielded with fine tined copper braid and
protected with FR PVC sheath in in existing surface / recessed PVC
conduit as required as per direction of Engineer in Charge.
Supplying and fixing of following sizes PVC conduit along with accessories
298 44 in recessed wiring including cutting the wall and making good the same in 0 0.00 0.00 0.00
case of recessed conduit as required.
Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60
mm deep on surface / recess with suitable size of phenolic laminated
300 45 sheet cover in front including cutting the wall and making good the same in Nos 4.00 212.40 849.60
case of recessed conduit as required.
( Tel junction Box)
301 46 Supplying & Commissioning of Telephone Hand Set. Nos 4.00 866.12 3,464.48
Supplying & installation of 10 pair KRONE make moudles with locking &
302 47 key arrangements fabricated with MS sheet & powder coated to be fixed on set 1.00 1098.58 1,098.58
concealed manner incl. good the damages.
303 0 SAFETY EQUIPMENTS 0 0.00 0.00 0.00
Supply and installation of Rubber Mats 12mm thick of size 2000mm x
1000mm x 12 mm thick Electrical tested with test certificate.
Supply and fixing of fire buckets with angular fabricated stand to fix 4
305 49 buckets in each stand for Electrical fire protection as per standards of sets 4.00 1770.00 7,080.00
Electrical Inspectorate.
Supply and fixing of Co2 fire extinguisher with mounting clamps with
pressure test certificate .
Supply and fixing of shock treatement charts duly laminated along with
307 51 separate colour single line diagram laminated, to be fixed in Electrical sets 3.00 767.00 2,301.00
control panel room.
Supply and fixing of first aid box with medicines complete with medicine
with three years expiry date to be fixed in Electrical control panel room.
309 0 EXTERNAL ELECTRICAL/SUBSTATION WORKS 0 0.00 0.00 0.00
Supply of all Materials, Labour and Stringing of 11 KV Overhead Line with,
55 mm2 Insulated Aluminum Conductor, on 100 X 116 mm RS Joist 10
Mtrs. long complete with required Insulators, Cross Arms, Stays Set
complete as per site requirement and Direction of Engineer-In-Charge.
312 B. 63 KVA 11 / 0.4 KV OUTDOOR SUBSTATION 0 0.00 0.00 0.00
Supply, Erection & Testing of 10.0 Mtrs. Long 116 mm X 100 mm Joist
Pole with 400 X 400 X 6 mm Base Plate to be used as Substation of
Double-Pole Structure support including excavation of Pole Pit in all kinds
313 1 of Soil, PCC Base Padding, Back Filling of the Pit with 1:3:6 PCC, Painting Nos. 2.00 23600.00 47,200.00
with two coats of Red oxide Primer and two coats of Aluminum Paint,
Construction of Brick Masonry, Cooping, fixing of Danger Board etc.
complete as required.
Supply and Erection of Structure Materials on Existing Pole supports made
out of fabricated M.S. Channels, Angles etc. as per the approved Drawing
314 2 including cost of Clamp, Nut Bolts, painting with 2 coats of Red Oxide MT 0.80 70800.00 56,640.00
Primer and 2 coats of Aluminum Paint complete as required for the
proposed Four Pole Structure.
Installation, Testing and Commissioning of 63 KVA, 11 / 0.433 KV Copper
Wound ONAN DY11 Transformer.
Supply, Erection and Testing of 11 KV 400 Amp. Horizontal Gang
Operated A.B. Switch on Existing Double Pole Structure including cost of
GI Pipe operating Handle of appropriate Length, Nut Bolts etc. complete as
Supply, Erection and Testing of 11 KV 400 Amp. Horizontal Gap Fuse on
317 5 Existing Double Pole Structure including cost of Nut Bolts etc. complete as Set 1.00 5310.00 5,310.00
Supply, Erection and Testing of 12 KV Lightning Arrestor on Existing
318 6 Double Pole Structure including cost of mounting arrangements, Nut Bolts Set 3.00 1062.00 3,186.00
etc. complete as required.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply and Jumpering of 55 mm2 Insulated Aluminum Conductor including
cost of Jumpering, Binding with Insulators etc. complete as required.
Supply of all Materials, Installation & Testing of 3 Mtrs. long 50 mm
Diameter Class–B perforated GI Pipe Earth Electrode confirming IS:3043
320 8 including cost of Salt, Charcoal, Masonry Enclosure, C I Cover, Watering Nos. 4.00 4130.00 16,520.00
Funnel, Labour Charges for excavation of Pit in all kinds of Soil complete
as required (For Body, Lightning Arrestor & DP).
Supply of Materials and Installation of Safe Earth Electrodes (Chemical
321 9 Earthing) including cost of Electrode, Earthing Compound, Excavation of Nos. 3.00 17700.00 53,100.00
Earthing Pit, Refilling, etc. as required (For Neutral).
Supply of Materials and Laying Underground / Floor / Wall including
making End Termination and testing of following sizes of G.I. Earthing
Conductor Earthing of Equipment's, Switch Boards and Panels as required
complete as per Direction of Engineer-In-Charge.
Supply of Materials and laying Underground / Floor / Wall including making
End Termination and Testing of following sizes of Copper Flat for Loop
Earthing of Equipment’s, Switch Boards & Panels as required complete as
per Direction of Engineer-In-Charge.
328 C. PANEL BOARDS & DBS: 0 0.00 0.00 0.00
Supply, Installation and Testing of L.T. Outdoor / Indoor Floor mounted
type Distribution Boards made out of 2 mm thick CR Sheet Metal Cubicle,
duly Acid treated for Derusting, Premiered and painted with 2 coats of
Enamel Paint of approved shade; Dust, Damp and Vermin proved; having
Hinged Door and Compartmental Arrangement for each equipment and
Busbar Chamber on the Top of the Panel running horizontally; having
provision for Cable/ Conduit Entry, Earthing Studs as per specification
mentioned below duly factory wired conforming to the relevant ISS and as
per special conditions of contract making good the damages caused
complete as per the Direction of Engineer-In-Charge.
330 (a) Outdoor Sub Station Panel 0 0.00 0.00 0.00
331 0 Bus bars: 4 Nos. 200 Amp. Aluminum Busbar. Set 1.00 59000.00 59,000.00
Supply of all Materials, Installation & Testing of 3 Mtrs. Long 50 mm
Diameter Class–B Perforated GI Pipe Earth Electrode confirming IS:3043
including cost of Salt, Charcoal, Masonry Enclosure, C I Cover, Watering
Funnel, Labour Charges for Excavation of Pit in all kinds of Soil complete
as required (For Body Earthing of Panel Board & DB - 6 Nos. & for Pump 2
Supply of Materials and Installation of Safe Earth Electrodes (Chemical
334 2 Earthing) including cost of Electrode, Earthing Compound, Excavation of No 2.00 17700.00 35,400.00
Earthing Pit, Refilling, etc. as required (For Lightning Protection System).
Supply of Materials and Laying Underground / Floor / Wall including
making End Termination and testing of following sizes of G.I. Earthing
Conductor for Loop Earthing of Equipment's, Switch Boards & Panels as
required complete as per Direction of Engineer-In-Charge.
Supply of Materials and Laying Underground / Floor / Wall including
making end termination and testing of 8 SWG G.I. Wire for Loop Earthing
of Equipment's, Switch Boards & Panels as required complete as per
Direction of Engineer-In-Charge.
338 E. SAFETY EQUIPMENT'S: 0 0.00 0.00 0.00
339 1 Supply and hanging of Shock Treatment Chart duly Laminated. Nos. 3.00 619.50 1,858.50
340 2 Supply & Laying of 8 mm Thick Rubber Mat, ISI mark of 1100 V Grade. Sqm 12.00 908.60 10,903.20
Supply and Installation of 3 Nos. Fire Buckets on a Mild Steel Stand
complete as per specification and requirement of Fire Safety Provisions.
Supply and Installation of 5 Kgs. Capacity CO2 type Fire Extinguisher
complete as required.
343 5 Supply and Installation of 440 Volt Danger Boards. Nos. 4.00 141.60 566.40
344 6 Supply and fixing of 100 mm dia GI Pipe. Mtrs. 12.00 708.00 8,496.00
345 Sub-Total of Electrical Works 26,70,965.40
346 Grand Total 2,03,89,306.28
346 Grand Total 2,03,89,306.28
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
5 NIT.pdf
Tender Document
3a GCC PMC Contracting Works.pdf
Tender Document
3b SCC.pdf
Tender Document
8 Milestone.pdf
Tender Document
11 BOQ BOL 003 NHM.pdf
Tender Document
13 List of Approved Makes NHM Project Odisha.pdf
Tender Document
14 Scope of Work.pdf
Tender Document
Drawings Bolangir PHC at Mahimunda of Puintala.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .