| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.8 L+₹48,458 (3.65%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.8 L+₹3.5 L (26.4%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.1 L+₹3.8 L (28.9%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹17.8 L+₹4.5 L (33.9%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
PERIODICAL SERVICES AND MISC B/R REPAIRS IN ZONE-I AREA UNDER JAIPUR MILITARY STATION
2023_MES_587881_1
GE/8276/2022-23
Open Tender
Civil Works
Item Rate
270 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹40,000
Yes
26 Jul 2023
31 Mar 2023
24 May 2023
31 Mar 2023
22 May 2023
8 May 2023
31 Mar 2023 - 14 Apr 2023
Amount
Taking down cement plaster on brick or stone or concrete surfaces of wall/ceiling etc , icluding raking out joints , hacking for key, scrubbing down with water etc. complete all as specified and directed
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:4) with WPC @100 ml per 50 kg of cement or all as per manufatucring Instruction and finishing the surface fair and even etc. complete all as specified and directed
Supply only integral water proofing liquid compound
M&L for Rendering 10mm thick in CM 1:3 to fair face of brick works or concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement etc. complete all as specified and directed
Rendering 15 mm thick cement plaster in CM 1:6 on other faces of brick work (Internal Surface) including finished even and smooth without using extra cement etc. complete all as specified and directed
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour etc. complete all as specified and directed
M&L for putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step 3) Allow 6-8 hrs time to dry the putty surface
M&L for one coat of acrylic water based exterior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats etc. complete all as specified and directed
M&L for one coat of acrylic water based interior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats on wall/ ceiling complete all as specified and directed.
M&L preparing old surface of ceiling and applying two coat of distemper (Oil emulsion) of approved tint all as directed.
M&L preparing old decorated surface of walls including brooming down and cleaning the surfaces and applying two coats of distemper (Oil emulsion) of approved tint all as directed
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. Note : (a.) The work pertaining to periodical services & Water Proofing in this contract shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer.
M&L for taking out existing Automatic sliding glass door sensor (Dorma system), repairing, servicing and refixing in same position etc. complete all as specified and directed
S & F in repair for change of complete door (Sensor with Automatic sliding glass door Dorma system) fixed all as specified and directed
S & F in repair PVC Vanishing blinds of any size and any type (Horizontal/ vertical/roller/Zebra type) Blinds complete all as specified and directed.
S&F, powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing (minimum thickness of powder coating not less than 50 micron) etc. complete all as specified and directed
S & F 5.5mm thick plain sheet glass ordinary quality to aluminium door/ window in sqaures not exc 0.5 sqm in each pane complete
S&F 12mm thick pre-laminated particle board exterior grade, both side decorative choice lamination fixed to wooden/aluminium frame work as in door/ cupboard shutters etc. complete all as specified and directed
Demolition wall and ceiling boards (fibre pulp, insulation etc) or insulation board/ slabs/ blankets, any thickness including cover fillets etc. complete all as specified and directed
M & L for 12mm thick perforated particle board/ tiles for insulation and accoustic purposes of any size fixed with nails to timber frame work or with staples on snap grid on ceiling flat or sloping (As per sample held with AGE B/R-I Sub Divn) and applying two coat of oil bound distemper of any tint including priming the surfaces
All as per item above but expect board/tile
S&F in repairs 350 mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed etc. complete all as specified and directed
S&F in repairs Brass barrel tower bolts 300 mm long, with cast or sheet barrel and rolled or cast bolts and fixed etc. complete all as specified and directed
S&F in repairs 150 mm long Extruded brass handles , fabricated type polished etc. complete all as specified and directed
M/S SHRINARAYAN MEENA
Deep Construction Company
ABHI CONSTRUCTIONS
J.J.ENGINEERING
UNIVERSAL INFRAPROJECT PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .