| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹23.1 L+₹2.4 L (11.6%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance Highest bid value | |
| 3 | L3₹23.4 L+₹2.7 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Highest bid value | |
| 4 | L4₹23.8 L+₹3.1 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Highest bid value | |
| 5 | L5₹23.9 L+₹3.2 L (15.2%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L5 | Rejected-Finance Highest bid value |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Shri R Durga Shyam, EE, GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIRS OF STAND BY DG SETS, FIRE ALARM SYSTEM AND MISC EM REPAIRS OF WORKS/LA AND EARTHING/LA AT AF STN SALUA UNDER GE (AF) KALAIKUNDA
2020_MES_367164_1
8585/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹40,000
Yes
29 Sept 2020
6 Aug 2020
28 Aug 2020
6 Aug 2020
27 Aug 2020
21 Aug 2020
Amount
Materials and labour for maintenance and servicing of DG Sets of capacity 20 KVA complete all as specified and as directed. Notes:- (a) One service of DG Set is termed as ‘EACH JOB’. (b) Spare parts costing upto Rs. 200.00 shall be replaced as a part of servicing otherwise paid under Separate items .
All as per item No 1 here-in-before but for DG Sets of capacity 30 KVA complete all as specified and as directed.
All as per item No 1 here-in-before but for DG Sets of capacity 82.5 KVA complete all as specified and as directed.
All as per item No 1 here-in-before but for DG Sets of capacity 125 KVA complete all as specified and as directed.
All as per item No 1 here-in-before but for DG Sets of capacity 250 KVA complete all as specified and as directed.
Labour only for repair and calibration of FIP of DG Sets of capacity 250 KVA including replacement of plunger, washer manifold, injection nozzles etc. all as required and testing after re-fixing on engine and setting the rated RPM complete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately items.
All as per item No 2 here-in-before but for DG Sets of capacity 125/82.5 KVA complete all as specified and as directed.
All as per item No 2 here-in-before but for DG Sets of capacity 30/20 KVA complete all as specified and as directed.
Labour for overhauling of injector nozzles including replacement of nozzles, washers, etc. and pressure setting as required for DG Sets of capacities 250 KVA and replacement of timing shaft with coupling complete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately under seperate items .
All as per item No 3 here-in-before but for DG Sets of capacity 125/82.5 KVA complete all as specified and as directed.
All as per item No 3 here-in-before but for DG Sets of capacity 30/20 KVA complete all as specified and as directed.
Labour for complete overhauling of self starter including replacement of carbon, armature coil, field coil, bush and bendix pinion and other related components to the capacities DG sets 250 KVA, complete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately under seperate items.
All as per item No 4 here-in-before but for DG Sets of capacity 125/82.5 KVA complete all as specified and as directed.
All as per item No 4 here-in-before but for DG Sets of capacity 30/20 KVA complete all as specified and as directed.
Labour only repair and overhauling of dynamo including replacement of armature coil, carbon set, field coil, clutch patti, bearing etc and other related items as required and re-fixing the same on mountings and testing complete for capacities DG sets 250 KVA, complete all as specified and as directed. Note: Spare parts shall be measured and paid separately under seperate items .
All as per item No 5 here-in-before but for DG Sets of capacity 125/82.5 KVA complete all as specified and as directed.
All as per item No 5 here-in-before but for DG Sets of capacity 30/20 KVA complete all as specified and as directed.
Dismantling the radiator and cleaning the same completely and detect the leakage/breakage and repair the radiator by soldering/brazing and testing for the capacity of DG Sets 250 KVA, complete all as specified and as directed.
All as per item No 6 here-in-before but for DG Sets of capacity 125/82.5 KVA complete all as specified and as directed.
All as per item No 6 here-in-before but for DG Sets of capacity 30/20 KVA complete all as specified and as directed.
Supply and top up the coolant K Cool super plus-25/75 complete all as specified and as directed.
Supply and changing the engine oil of suitable grade including drain out existing used oil complete all as specified and as directed.
Supply& fixing the Diesel filter element in DG set of 250 KVA capacity, complete all as specified and as directed.
All as per item No 9 here-in-before but Oil Filter element, complete all as specified and as directed.
All as per item No 9 here-in-before but Air cleaner hose pipe with clamp, complete all as specified and as directed.
All as per item No 9 here-in-before but Radiator hose pipe with clamp, complete all as specified and as directed.
All as per item No 9 here-in-before but Safety control valve, complete all as specified and as directed.
All as per item No 9 here-in-before but flexible pipe for fuel pump to PT pump with banjo washer , nut bolt, complete all as specified and as directed.
All as per item No 9 here-in-before but flexible pipe for Disel tank to filter with banjo washer , nut bolt, complete all as specified and as directed.
All as per item No 9 here-in-before but Air cleaner Filter, complete all as specified and as directed.
All as per item No 9 here-in-before but Automatic voltage regulator, complete all as specified and as directed.
Supply& fixing the Diesel filter element in DG set of 125/82.5 KVA capacity, complete all as specified and as directed.
All as per item No 10 here-in-before but Oil Filter element, complete all as specified and as directed.
All as per item No 10 here-in-before but Air cleaner hose pipe with clamp, complete all as specified and as directed.
All as per item No 10 here-in-before but fuel indicator assembly, complete all as specified and as directed.
All as per item No 10 here-in-before but flexible pipe for diesel tank to filter with banjo washer, nut bolt, complete all as specified and as directed.
All as per item No 10 here-in-before but Radiator hose pipe with clamp, complete all as specified and as directed.
All as per item No 10 here-in-before but Automatic voltage regulator, complete all as specified and as directed.
All as per item No 10 here-in-before but Air cleaner Filter, complete all as specified and as directed.
Supply& fixing the Diesel filter element in DG set of 30/20 KVA capacity, complete all as specified and as directed.
All as per item No 11 here-in-before but Oil Filter element, complete all as specified and as directed.
All as per item No 11 here-in-before but Air cleaner hose pipe with clamp, complete all as specified and as directed.
All as per item No 11 here-in-before but Radiator hose pipe with clamp, complete all as specified and as directed.
All as per item No 11 here-in-before but flexible pipe for fuel pump to PT pump with banjo washer, nut & bolt, complete all as specified and as directed.
All as per item No 11 here-in-before but flexible pipe for Disel tank to filter with banjo washer, nut & bolt, complete all as specified and as directed.
All as per item No 11 here-in-before but By pass filter, complete all as specified and as directed.
All as per item No 11 here-in-before but Automatic voltage regulator, complete all as specified and as directed.
All as per item No 11 here-in-before but Air cleaner Filter, complete all as specified and as directed.
Supply& fixing the Dynamo rectifier assembly in DG set of 250 KVA capacity, complete all as specified and as directed.
All as per item No 12 here-in-before but Dynamo plate set (set of two pcs), complete all as specified and as directed.
All as per item No 12 here-in-before but Dynamo carbon (Set of 2 Pcs) , complete all as specified and as directed.
Supply& fixing the Dynamo Rotor assembly in DG set of 125/82.5 KVA capacity, complete all as specified and as directed.
All as per item No 13 here-in-before but Dynamo rectifier assembly, complete all as specified and as directed.
All as per item No 13 here-in-before but Dynamo starter assembly, complete all as specified and as directed.
All as per item No 13 here-in-before but Dynamo bearing 6211ZZ, complete all as specified and as directed.
All as per item No 13 here-in-before but Dynamo carbon (Set of 2 Pcs), complete all as specified and as directed.
Supply& fixing the Dynamo rectifier assembly in DG set of 30/20 KVA capacity, complete all as specified and as directed.
All as per item No 14 here-in-before but Dynamo cutout assembly, complete all as specified and as directed.
All as per item No 14 here-in-before but Dynamo starter assembly, complete all as specified and as directed.
All as per item No 14 here-in-before but Dynamo bearing 6211ZZ, complete all as specified and as directed.
All as per item No 14 here-in-before but Dynamo carbon (Set of 2 Pcs), complete all as specified and as directed.
Supply & fixing the FIP spare parts such as Delievery valve in DG set of 125/82.5 KVA capacity, complete all as specified and as directed.
All as per item No 15 here-in-before but FIP plunger, complete all as specified and as directed.
Supply & fixing the FIP spare parts such as Delievery valve in DG set of 30/20 KVA capacity, complete all as specified and as directed.
All as per item No 16 here-in-before but FIP plunger, complete all as specified and as directed.
Supply & fixing the Injector spare parts such as njector nozzle in DG set of 125/82.5 KVA capacity, complete all as specified and as directed.
All as per item No 17 here-in-before but Injector washer, complete all as specified and as directed.
Supply & fixing the Injector spare parts such as njector nozzle in DG set of 30/20 KVA capacity, complete all as specified and as directed.
All as per item No 18 here-in-before but Injector washer, complete all as specified and as directed.
Material ,labour and repair/replacement of canopy hinges of enclouser type DG Sets any sizees all as specified and directed by Engg-in-charge.
Material , labour and repair to external Battery charger suitable for 12 V DC battary complete all as specified and as directed by Engg-in-charge.
Supply and fix battery of capacity 150 AH complete all as specified and as directed by Engg-in-charge.
Supply and fix battery of capacity 180 AH complete all as specified and as directed by Engg-in-charge.
Supply and fixing Battery lead incluiding clamp both ends complete all as specified and as directed by Engg-in-charge.
M&L for total wiring of AMF Panel for 250 KVA DG Sets complete all as specified and as directed by Engg-in-charge.
M&L for total wiring of AMF Panel for 82.5/125 KVA DG Sets ccomplete all as specified and as directed by Engg-in-charge.
M&L for total wiring of AMF Panel for 20/30 KVA DG Sets complete all as specified and as directed by Engg-in-charge.
Labour for servicing & replacement wornout parts (relays, metering equipments, contro circuits etc .) of AMF pannel to the capacity of DG set 250 KVA, omplete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately items.
All as per item No 27 here-in-before but capacity of DG set 125/82.5 KVA, complete all as specified and as directed.
All as per item No 27 here-in-before but capacity of DG set 30/20 KVA, complete all as specified and as directed.
Supply only power contactor 4 pole for 250 KVA DG AMF Panel, complete all as specified and as directed.
Supply only SMPS for 250 KVA DG Set AMF panel, complete all as specified and as directed.
Supply only PCB board for 250 KVA DG AMF Panel, complete all as specified and as directed. .
Supply only relay/LVM for 250 KVA DG AMF Panel, complete all as specified and as directed.
Supply only Battary charger for 250 KVA DG AMF Panel, complete all as specified and as directed.
Supply only controller circuit for 250 KVA DG AMF Panel, complete all as specified and as directed.
Supply only power contactor 4 pole for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only SMPS for 125/82.5 KVA DG Set AMF panel, complete all as specified and as directed.
Supply only Battary charger for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only power fuse link with breaking capacity 80 KA for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only PCB board for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only relay/LVM for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only controller circuit for 125/82.5 KVA DG AMF Panel, complete all as specified and as directed.
Supply only power contactor 4 pole for 30/20 KVA DG AMF Panel, complete all as specified and as directed.
Supply only SMPS for 30/20 KVA DG Set AMF panel, complete all as specified and as directed.
Supply only relay/LVM for 30/20 KVA DG AMF Panel, complete all as specified and as directed.
Supply only PCB board for 30/20 KVA DG AMF Panel, complete all as specified and as directed.
Supply only Battary charger for 30/20 KVA DG AMF Panel, complete all as specified and as directed.
Supply only controller circuit for 30/20 KVA DG AMF Panel, complete all as specified and as directed.
Supply only Battery of capacity 7AH , 12 Volts for fire Alarm panal complete all as specified and as directed.
S&F Smoke dectors (Photoelectric/optical complying with and type certified to EN-45 intelligence Addressable multisensor (HEAT+SMOKE) Dector with Base as per IS 11360 for fire Alarm panal complete all as specified and as directed.
S&F in replacement of Copper Air termination rod 12 mm dia single pointed 300mm long along with base plate welded at bottom of termination rod, of size 10 cm long fabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners (wooden block) complete all as specified and as directed.
S&F in replacement of Copper strip 20 x3.15 mm for roof/ground conductors and bracing to down conductors above ground, complete all as specified and as directed.
S&F in replacement of Copper strip 32x6mm for roof conductors and bracing to down conductors above ground, complete all as specified and as directed.
S&F in replacement of Porcelain insulator of existing size for isolation of conductor from the building wall by providing 15cm long fastners at every 16 cm distance in the wall complete all as specified and as directed.
M&L of repaired earthing pit complete with copper earth plate electrode 600x600x3.15mm thick buried directly in ground (Earth plate not less than 3.0 M in deep below ground level) with top edge of the plate not less than 2.4m below normal ground level connected to copper earth strip 25x3.15 mm by means of bolts, nuts, check nuts and washers of galvanized iron all as drected by Engr-in- Charge and connected to earthing test point all as specified and directed including necessary earth work in any type of strata and PCC 1:3:6 type B1 for chamber and RCC chamber cover 50mm thick in lieu of CI cover and copper strip protected by 40mm GI pipe light grade complete. Including filling of agriculture sand for earth pit as directed by Engineer-in-charge. Excavation and removal of excavated soil and filling of agriculture sand brought from out side defence land and Magnesium Sulphate of 50 Kg per earth pit poured with salt and charcoal shall be included in the overall rate quated. No extra payment shall be paid.
Supply only back filling compound (Magnesium sulphate ) in existing earth pits through G I pipes as per site requirment complete all as specified and as directed.
M&L for brazing of copper earth strip including grainding and prepartion of existing earth strip complete all as specified and as directed.
SUMAN CONSTRUCTION
M/S Jamuna Traders
MS INDIRA ELECTRICS
Guru Charan Mahata
SHARMA ENTERPRISES
Ganguly Construction
MS R.K.ENTERPRISE
M/S C C CONSTRUCTION
I.S.ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .