Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-Finance DOCS ARE IN ORDER HENCE ADMITTED | |
| 2 | L2₹48.0 L+₹3.2 L (7.09%)Accepted-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Accepted-Finance DOCS ARE IN ORDER HENCE ADMITTED | |
| 3 | L3₹48.1 L+₹3.3 L (7.44%)Accepted-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Accepted-Finance DOCS ARE IN ORDER HENCE ADMITTED | |
| 4 | Rejected-Technical | - | Rejected-Technical Mentioned cat not found |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Dec 2019, 6:00 pmClosed
GE (NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
REPAIR/ REPLACEMENT OF FIRE FIGHTING SYSTEM , M and O MAINT OF E/S,W/S INSTALLATION AND REPAIR OF B/R AND E/M ITEMS AT NAVAL AVIATION ENCLAVE NAE SANTACRUZ.
2019_MES_299015_1
8782/B
Open Tender
Civil Works
Item Rate
334 days
Santacruz
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat b(i),d(v)
9 documents required · 9 mandatory
₹500
GE NW BHANDUP
₹90,000
Yes
17 Feb 2020
19 Nov 2019
26 Dec 2019
19 Nov 2019
21 Dec 2019
9 Dec 2019
19 Nov 2019 - 23 Nov 2019
Amount
Comprehensive maintenance of electrically operated travelling (EOT) crane of 05 MT, Span -44900 mm, SWL-5000 Kgs capacity, floor operated comprising of hoist motor, micro motor, long travel motor, cross travel motor, gear box, control panel and other connected accessories installed at NAE Santacruz Make- Dinesh Enterprises Ser No- 1215 The following spares replacement :-
Supply only contactor 32 Amp capacity, 440 volts, 50 HZ, AC Supply.
Supply only brake liner unit 4 inches.
Supply only brake liner unit 6 inches.
Supply only limit switch two way shut type 16 Amps (Make: Siemens).
Supply only over load relay 3.8 to 6 Amps (Make : L&T/BCH).
Supply only over load relay 6 Amps to 13.2 Amps (Make : L&T/BCH)
Supply only pendent push buttons (Make : BCH/Airem/ L&T)
Supply only pendent indicators (Red/Green)
To carry out load Test of 5 MT Crane as per Manufacturer norms and provide a load test certificate by manufacturer all as specified.
M & L for painting 5 ton crane completely with two coats of golden yellow paint including preparation of existing surface by scrapping detoritied paint etc. all as directed by Engr-in-charge.
Repair, Maintenance & Servicing of DG Set 500 KVA Make- Crompton Greaves Model No 12V14TAG complete including with B Check through OEM as per direction of Manufacturer as directed. Spares replacement of the following :-
(a) Supply and replacement of Greaves Max Therm Lub Oil
(b) Supply and replacement of Oil filter
(c) Supply and replacement of Fuel filter
(d) Supply and replacement of K Kool additive oil
Supply and fixing GI Pipe 50 mm medium grade with fittings
Supply and fixing of gun metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipes of 50 mm dia as specified and directed.Make.Leader ISI marked
Repair and maintenance of 75 HP fire service main pump multi stage having 2280 LPM at 80 Mtr head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100 HP diesel engine including servicing by replacing unserviceable items of gland packing , bearing and charging lubricants for smooth running including servicing of 75 HP diesel engine by replacing filters, lubricant oil including defective parts like coupling , oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tank to engine, battery leads and checking of charging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed.
Takig down unserviceable Fire fighting motor pump set of capacity 3 phase 100 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified.
Repair and maintenance of 7.5 hp fire service jockey / booster pump multi stage having 180 LPM at 56 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 7.5 hp AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed. Location: Fire Pumphouse, Vikramaditya
Supply and fix in repairs foot valve cast iron body suitable for 100 mm bore MS pipe connection all as specified Make-Kirloskar/Kartar/SIR/AUDICO
Supply and fix in repair Smoke and Heat Multisensor detector complete all as specified and directed. Make- Apollo XP95 Model 55000-885
Supply and fix in repair Hooter Sounder Visual Indicator base complete all as specified and directed Make- Apollo Model- 45681-393
Supply only VVVF Drive 1000 Volts Make- Yashikawa.
Supply only step down Transformer 415 Volts. Suitable of 5 MT Capacity crane
Supply only step down Transformer 220 Volts. Suitable of 5 MT Capacity crane
Supply and fix IGUS flexible plastic cable tray of size 100mmx 50mm complete all as specified.
Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 02 ton of any make /type after disconnecting refrigerant pipes , drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda , checking and replacing the spares like relay, capacitors, thermostat, fan motor blades & blower and including servicing, overhauling and connecting of refrigerant pipe, drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
Supply only blower drum for split type air conditioner 2.0 ton capacity complete all as specified
Supply only outdoor fan blade for split type air conditioner 2.0 ton capacity complete all as specified.
Supply only outdoor fan motor for split type air conditioner 2.0 ton capacity complete all as specified.
Supply only running capacitor 45 mfd for split type air conditioner 2.0 ton capacity complete all as specified
Supply only starting capacitor 100 mfd for split type air conditioner 2.0 ton capacity complete all as specified.
Supply only fan capacitor 4 mfd for outdoor unit for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fix blower fan motor for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fix new hermetically sealed compressor in existing split type air conditioner 2.0 ton capacity including initial filling of refrigerant gas to the required pressure , brazing making electric/piping connection etc complete all as specified and directed Make – Voltas / Shriram / Tecumesh /Kirloskar / Hitachi/LG / Bluestar
Repair /replacement of fire fiting Non return valve reflux type with bypass arrangement complete of size 150 mm dia bore pipe complete all as specified and directed
Repair /replacement of fir fighting cast iron air valve with two air outlets confirming to IS 14845 of size 50 mm dia bore and fixing up in cast iron water supply mains size 100 mm dia complete all as specified and directed
Repair/replacement of fire fighting MS pipe of size 100 mm bore heavy duty in trenches laid on floor confirming to IS-3589 in any length welded including testing and commissiong complete
Repair/Replacement of fire fighting hose reel of 20mm dia & 30 mtrs long confirming to IS-5132 complete all as specified and directed
Repair/Replacement of fire fighting branch pipe & nozzle for 20 mm dia hose reel confirming to IS 8090 complete all as specified and directed
Repair/Replacement of fire fighting fire hydrant stand post with provn of single outlet confirming to IS 908 complete all as specified and directed
Repair /Replacement of fire fighting branch pipe & nozzle gun metal short branch pipes 63mm dia with male instantaneous inlet with Gun metal, hexagonal, detachable outlets nozzles bearing IS-903 complete all as specified and directed
Repair /Repalcement of Hydrant valves Female oblique type gun metal hydrant valve bearing IS 5290 type A 63 mm dia with flanged inlet and female instantaneous spring back outlet connection and complete with male blank cap & chain single hydrant valve
Supply and Fix in repairs new hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 1500 mm x 900 mm x 250 mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside fixed on wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directedall as specied and directed. Location: Vikramaditya
Supply and Fix in repairs new hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800 mm x 600mm x 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside fixed on wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directedall as specied and directed. Location: Vikramaditya
Supply and fix addressable heat and smoke combination (acclimate) with stand base complete all as specified and directed.
Supply and installing testing and comissionning addressable manual call points(MCP) complete all as specified and directed.
Supply and fix inrepacement of 23x PTZ camers including programaing complete all as specified and directed by Engineer in Charge. MAKE : HIKVISION /CP PLUS /HIMAX Note : (1) The Installation height for camaers is upto 50 mtrs and the rates are incusive of schafolding work for installation . (2) The ncessary MS brackets for installation of camera is inclusive of quotaed rates complete all as specified and directed.
Supply and fix inreplacement of SMPS for PTZ Camers complete all as specified and directed. MAKE : HIKVISION /CP PLUS /HIMAX
Supply and fix inreplacment of Eight Chanel Hybrid DVR suitable for 23x PTZ camara 400 HPS display 100 HPS recording 50 FPS play basis 1 audio in/out 16 alarm in 4 relay out network avilable with 7 days backup for 5 cameras complete all as as directed by Engineer in Charge MAKE :HIKVISION /CP PLUS /HIMAX
S&F control key board, support upto 82 scan dome & HRX-2000, HDX-1600 HNDR-2 series DVR, expended upto numerais slave controller complete all as specified and directed.
Supply and fix inreplacement of desktop computer with with 19.5 inch full HD moniter and CPU with 4GB ram and 1 TB hard disk along with all ncessary cord and softeware for operation of cameras all as directed by Engineer in Charge.
Supply and fixing in replacement of joy stick complete all as specified and directed.
Supply and fixing supply unit 12 volt complete all as specified and directed.
Comprehensive /Annual maintenance of CCTV System installed at NAE Santacruz and comprising of the following items as under :- Mini PTZ Dome cameras-4 Nos 8 Ch digital video recorder (DVR) - 01 No KBD digital keyboard/Joystick 24 Volt 2.1 Amp power supply -03 Nos Professiona CCTV Bosch monitor 21.5"-01 No Panasonic 22" LED TV -01 Nos 2 TB Survelliance harddisk Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
Comprehensive Annual maintenance of fire alarm system installed at NAE Santacruz comprising of following items Main control panel -02 Nos Heat and smoke detector-150 Nos Mannual call point -12 Nos Hooter cum strobe- 20 Nos Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Material and labour in repairs for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on PVC casing capping of 20/25 mm complete with sunk iron pressed steel terminal box concealed in wall for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch all as specified and directed.
All as per item No 55 her-in-before but one fan/exhaust fan controlled by one swicth all as specified and directed.
All as per item No 55 her-in-before but one 5 Amps switch socket combination on same board all as specified and directed.
All as per item No 55 her-in-before but one 5 Amps switch socket combination on Independent board all as specified and directed.
All as per item No 55 her-in-before but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on rigid PVC conduit and conduit accessories of 20/25 mm complete with sunk iron pressed steel terminal box concealed in wall for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one socket for connecting water coolers/ AC.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete
Supply and fix in repairs switch modular type 16 Amp one way, 1 module complete
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan electronic regulator stepped/socket type 120 watts AC 230 V.
Supply and fix in repairs motor starter 2 module 25 Amps, 230 Volts complete protection against overload for AC complete all as specified Make - Legrand or equivalent
M & L for rewinding the exhaust fan of 300 mm sweep , cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , varnishing, drying, backing , etc complete all as specified and directed.
M & L for rewinding the Air circulator fan of 600 mm sweep, cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed.
M & L for rewinding the Ceiling fan of 1200 mm sweep , cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed .
Supplying and fixing in repairs MCB TP 32 Amps, 415 volts complete all as specified. Cat No-408658 Make Legrand or equivalent
Supplying and fixing in repairs MCB TP 40 Amps, 415 volts complete all as specified. Cat No-408659 Make Legrand or equivalent
Supplying and fixing in repairs MCB TP 63 Amps, 415 volts complete all as specified. Cat No-408661 Make Legrand or equivalent
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix in repairs MCB SP 240 Volts 40 to 63 Amps breaking capacity 10 KA rating complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 4 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 4 sqmm PVC insulated copper conductor earth wire in PVC conduit/casing caping of suitable size (three run of 4 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 6 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6 sqmm PVC insulated copper conductor earth wire in existing conduit/casing caping of suitable size (three run of 6 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring all as specified and directed.
Supply and fix in repairs MCCB 415 volts, 16 KA Three pole 63 Amps complete all as specified.
Supply and fix in repairs MCCB 415 volts, 16 KA Three pole 100 Amps complete all as specified.
Supply and fixing in repairs highly efficient high power multi LED flood fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Philips/Luckar/CG
Supply and fixing in repairs retro fit LED tube rod 20 W PC diffuser complete with inbuilt driver suitable for existing 4' tube light fittings including modification existing wiring to suit with 20 watt LED tubes complete Make: Lucker/ CG /Havell
Supply and fixing in repairs highly efficient high power multi LED bay fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Philips/Luckar/CG
Supply and fixing in repairs recess mounted LED round flat panel 15 watt warm white with inbuilt driver including modification existing wiring/surface/ceiling to fix LED fitting complete all as specified and directed. Make: Lucker/ CG /Havell
Supply and fixing in repairs square surface mounted LED flat panel 12 watt PDC aluminium housing and PMMA diffuser makes it a robust luminaire, with inbuilt driver including modification existing wiring/surface to fix LED fitting complete all as specified and directed. Make: Lucker/ CG /Havell
Supply and fixing CMRI certified LED flameproof 1 x 16/20 watt tube light fixture IP65 protection complete all as specified and directed.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory. Make : Fast Electrode or equivalent as approved by the GE.including suitable earth strip , PCC pit and CI cover plate ,GI protection pipe of suitable size including testing on completion all as specified and directed. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates.(ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also.(iii) Necessary earth strip with GI Protection pipe to connect equipment shall also provided by the contractor .
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in stove enamelled steel conduit of 20/25 mm complete with sunk iron pressed steel terminal box for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one 5 Amps switch socket combination on independent board complete.
M&L for earth continuity conductor or main earthing lead fixed to wall on battern or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3 mm aluminium strip complete all as specified.
Outsourcing of services for electric supply installations 11/0.433 KV sub Station & stand by diesel Generator Sets comprising of transformer, AMF panels, APFC panels, HT VCBs, ACBs, LT Panels/FP Boxes, LT/HT UG Cables, lightning Arrestor, Earthing,metering equipments & batteries etc including routine maintenance, cleaning of equipments, Maintaining of daily records of electric supply and log books of DG sets with all parameters with stationery and including atending of electrical break downs and electrical repairs as directed with necessary expendable items and providing all types of tools and clamp meter, IR/ER tester, Earth rod, Hand Gloves, ladders etc and adopting necessary safety precautions in attending break downs, and electrical repairs, switching on/off street lights, top up of fuel as provided/stored by department and cleaning of equipments and surrounding area of installations in neat and presentable position by deploying Electrician (ITI Holder) - 01 in each shift of 08 hours duration required in two shifts in a day in all the days including sundays and holidays with arrangement of reliever duty at NAE Santacruz comprising of following shifts complete all as specified and directed :- Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs NOTE : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the trademen will be contractor's responsibility in consultation with MES/ users.
Overhauling and servicing through agency authorised by OEM of HT VCB, 11 KV, 800 Amps of make Siemens installed at NAE Santacruz including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gaskets, washers, panel heater, indicator bulbs and carry out any other repairs required at site to make the VCB fully functional, complete all as specified and directed.
Caliberation of relays of HT VCB by secondary and primary injection, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV parts of master relays complete all as specified and directed.
Overhauling of step down outdoor/indoor transformer 500 KVA 11/0.433 KV by disconnecting HT/LT terminals, decanning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, reassembling refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint after preparation of painted surfaces of transformer and testing and recommissioning on load etc, complete for the transformers of following rating (Filteration and dehydration of transformer oil, supply only transformer oil for topping up, supply only of HT & LT bushings shall be measured and paid separately under respective items)
Supply and fix in repair HT bushing suitable for 11/0.433 KV step down 500 KVA capacity transformer complete all as specified and directed
Supply and fix in repair LT bushing suitable for 500 KVA capacity transformer complete all as specified and directed :-
Supply and fix in repairs silica gel breather for 11/0.433 KV transformer 500 KVA capacity with silica jel etc. complete all as specified and directed.
S&F in repairs panel mounted digital type, PF meter, flush mounted, single phase, class 0.01 accuracy, 96mm x 96mm, including modiication of panel for fixing of PF meter, complete all as specified and directed.
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 800 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc complete all as specified and directed.
Supply and fix in repair Three pole MCCB 315 Amp 36 KA with rotary handle, 415 Volts Make-HPL/Legrand/Schneider
Supply and fix in repair Three pole MCCB 200A 25KA with rotary handle, 415 Volts Make-HPL/Legrand/Schneider
Supply and fix in repair Three pole MCCB 100A 16 KA with rotary handle, 415 Volts Make-HPL/Legrand/Schneider
Supply and fix in repair Three pole MCCB 160A 16 KA with rotary handle, 415 Volts Make-HPL/Legrand/Schneider
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor .
Outsourcing of services for watersupply and fire fighting installations with pump sets 03 phase, 415 Volts, AC 50Hz comprising of pumping panel boards, control cables, metering equipment, earthings, star delta/DOL starters, etc including operating of valves, NRVs and connected pipe lines and routine maintenance, maintaining of dailyrecords of pumping installations with all parameters with stationery and including attending of water supply break downs as directed with necessary expendable items and providing of tools and clap meter IR/ER tester etc and adopting necessary safety precautions in attending break downs and cleaning of equipment and surrounding area of installations in neat and presentable position by deploying Fitter General Mechanic(FGM) ITI Holder - 01 No in each shift of 08 hours duration required in three shifts in a day round the clock(24 Hours ) in all the days including Sundays and Holidays with arrangement of reliever duty with following equipments/installations at NAE Santacruz comprising of following shifts complete all as specified and directed (a) Centrifugal pump set of make Kirloskar 05HP - 02 Nos (b) Fire fighting pump (AC driven) 2850 LPM (c) fire fighting pump ( diesel engine driven) 2280 LPM (d) Jockey pump 180 LPM (e) Fire Fighting piping network with hydrants and valves. Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs Note : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the tradesmen will be contractor's responsiblity in consultation with MES/ users.
Supply and fixing on floor, ceiling wall and in sump jointing GI tubing medium grade including all fittings such as bends elbows tees union short pieces connectors check nuts caps plugs etc for the following sizes complete all as specified and directed. For 80 mm bore
All as per Item No 105 here-in-before but for 50 mm bore
All as per Item No 105 here-in-before but for 40 mm bore
All as per Item No 105 here-in-before but for 25 mm bore
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe for the following sizes complete all as specified and directed For 80 mm bore
All as per Item No 106 here-in-before but for 40 mm bore
All as per Item No 106 here-in-before but for 25 mm bore
All as per Item No 106 here-in-before but for 20 mm bore
Takig down unserviceable moo block motor pump set of capacity 3 phase 5 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified.
Cleaning of underground sump by draining / pumping of water removing / sludge from bottom removing algaes and other growth from wall/floor/ roofs by high pressure cleaning method with rotary jets with approved detergent fubbing with vaccum cleaner sucking out all dirty water disinfecting the sump with chemical treatment (Chemical approved by FOA/WHO to make the sump totally clean bacteria free including painting MS steps manhole covers and suction pipe with synthetic enamel paint of 2000 gallons capacity at NAE Santacruz complete all as specificed and directed.
Material and labour for disconnecting & stopping of incoming/ washout and outgoing pipes by making suitable arrangements to avoid chocking of pipe line, removing total water from the tank & depositing the same in low laying areas all as directed cleaning the underground sump from in side by using high pressure cleaning method with rotary jet wilth approved detergent rubbing/ scrapping wall / floor /ceiling with wet vaccume cleaner sucking out all dirty water and disinfecting the tank chemical treatment (chemical approved by FOA/WHO) to make sump totally cleaned and bacteria free including painting pit cover marking date of cleaning and next due and pipes (raising delivery wash out and over flow with sluice valves) including painting of pipe with two coats of synthetic enemel paint as per MES colour approved by EIC at site for RCC underground sump 25000 gallons at NAE Santacruz complete.
Supply and fix in repairs brass foot valve 50 mm size screw type heavy grade of make Kirloskar or equivalent all as specified & directed by Engineer-in-Charge
cooltech engineering services
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .