| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC SAINIK COLONY JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹25.1 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹26.0 LRejected-Finance HOUSING COLONY UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹26.0 L | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹26.4 LRejected-Finance BHAGWATI NAGAR JAMMU | ₹26.4 L | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | KULDEEP KUMAR SUDAN H2 | R S ELECTRIC INFRA H3 | BEE AAR ENTERPRISES H1 |
|---|---|---|---|---|---|---|
| 1.00 | Strengthening and Improvement of LIS Kandyar between RD 0 to 1200 mtrs including Mechanical Components by way of Providing, Installation, Testing, Commissioning of one no. 2.25 Cusec discharge 49 m Head HC Pumping unit and Design, Fabrication, Installation, Testing and Commissioning of 03 no. 110 Ampere Auto Starter cum fault analyser along with associated works at Lift Irrigation Station Kandyar district Reasi as per the details of the works to be executed as per Annexure 'A' of Standard Bidding Document (SBD) of e-NIT no. MICD/J/57 dated 23/01/2026 uploaded in tender documents. | 1 | Complete Job | 25,99,000 ₹25,99,000 | 25,08,450 ₹25,08,450 | 26,40,000 ₹26,40,000 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
17 Feb 2026, 12:00 pmClosed
Executive Engineer MICD Jammu
O/o Executive Engineer MICD Jammu
Strengthening and Improvement of LIS Kandyar between RD 0 to 1200 mtrs including Mechanical Components by way of Providing,Installation,Testing,Commissioning of one no. 2.25 Cusec discharge 49m Head HC Pumping unit along with associated works
2026_IFC_301286_1
e-NIT no 57 of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
90 days
Kandyar
Please refer SBD documents.
10 documents required · 10 mandatory
₹500
Executive Engineer MICD Jammu
₹66,000
O/o Executive Engineer, MICD Jammu
7 Mar 2026
23 Jan 2026
17 Feb 2026
23 Jan 2026
17 Feb 2026
28 Jan 2026
28 Jan 2026
Strengthening and Improvement of LIS Kandyar between RD 0 to 1200 mtrs including Mechanical Components by way of Providing, Installation, Testing, Commissioning of one no. 2.25 Cusec discharge 49 m Head HC Pumping unit and Design, Fabrication, Installation, Testing and Commissioning of 03 no. 110 Ampere Auto Starter cum fault analyser along with associated works at Lift Irrigation Station Kandyar district Reasi as per the details of the works to be executed as per Annexure 'A' of Standard Bidding Document (SBD) of e-NIT no. MICD/J/57 dated 23/01/2026 uploaded in tender documents.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
SBD.pdf
Tender Documents • 0.58 MB
BOQ_977604.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid