| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹19.5 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹21.5 L+₹2.0 L (10.0%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L2 | Admitted-Finance | ||
| 3 | Not Admitted-Fee/PreQual/Technical 260 DEFENCE COLONY FLYOVER MARKET NEW DELHI NEW DELHI 110024 SOUTH DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | - | Not Admitted-Fee/PreQual/Technical Others-undertaking of being blacklisted by govt state uploaded but not as per DNIT. | ||
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-EMD submitted in Term deposit roll over advice instead of DD and FDR and Bankers cheque Another reason status of firm document not uploaded by bidder hence rejected. |
Tender Value
₹17.8 L
EMD Value
₹35,500
Closing Date
24 Sept 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HE RAC
room no 225 department of hospital Engineering And planning RAC Division
SITC of 2 Nos of cooling Towers having capacity 90Tr 2 by replacing one old cooling tower at Animal House Plant PGIMER Chandigarh
2026_PGIME_925636_1
PGI/Engg/RAC/2026/324
Open Tender
Miscellaneous Works
Works
90 days
animal house
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹35,500
7 Oct 2026
10 Sept 2026
25 Sept 2026
10 Sept 2026
24 Sept 2026
10 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, testing and commissioning of Induced Draught Counter Flow type Premium low noise , CTI Certified Cooling Towers as per CTI STD-201. The Cooling Tower’s make should be listed on Cooling Technology Institute (CTI) web link. The Cooling Tower shall be complete with FRP Casing, FRP Basin, FRP louvers, FRP access door along with FRP inspection window. All internal supports/ structure should be Pultruded FRP. Unpressurised - Gravity Flow, Header and branch arm type water distribution system. 0.2 mm thick PVC Film Fills, High Efficiency Drift Eliminators, Ladder and Axial Flow Propeller Type Fan. Motor should be Totally Enclosed Air Over (TEAO), Weather Proof type with IP-55 protection class & Premium Efficiency, suitable for 415±10% volts, 50 cycles, 3 phase power supply and related accessories. Motor RPM should not be more than 360 RPM with direct driven system. FRP Deflector Cowls with acoustic enclosure to further reduction of noise is mandatory. The Cooling Tower selection should be identifiable from the selection matrix of the manufacturer at the CTI website. | 2 | nos. | 5,75,284 | ₹11,50,568 |
| 1.01 | 90 TR Induced draft Cooling tower (HVAC Application) Water flow rate: in m3/hr. / USGPM/ LPM =280 USGPM Inlet (Hot) water Temp: in degree C / in degree F =97.5 F Outlet (Cold) water temp: in degree C / in degree F = 90F Wet bulb temp: in degree C / in degree F =83 F 2 | - | - | - | - |
| 2CONDENSER WATER PIPE | |||||
| 2.01 | Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.butexcluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. | - | - | - | - |
| 2.02 | 200 mm Dia | 50 | Meter | 3,378.6 | ₹1,68,930 |
| 2.03 | 150 mm Dia | 25 | Meter | 2,062.8 | ₹51,570 |
| 2.04 | 100 mm Dia | 10 | Meter | 1,403.1 | ₹14,031 |
| 2.05 | 50 mm Dia | 30 | Meter | 603.9 | ₹18,117 |
| 3BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. | |||||
| 3.01 | 200 mm dia | 3 | nos. | 9,777 | ₹29,331 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.25 MB
BOQ_972707.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .