Loading…
Loading…
Tender Value
₹18.6 L
EMD Value
₹18,600
Closing Date
25 Sept 2026, 3:00 pm3d left
COMMISSIONER
ANNAL GANDHI ADIGAL SALAI RAMANATHAPURAM
Ramanathapuram Municipality Repair and Maintenance works for OCEMS and Electromagnetic Flow Measurement System and Operation and Maintenance for One year
2026_MAWS_705628_1
2709/2021/E1
Open Tender
Maintenance Works
Works
365 days
MUNICIPAL OFFICE RAMANATHAPURAM
Must be Equipment Manufacturer or an Authorized Dealer and expert in operate and maintenance
2 documents required · 2 mandatory
₹0
₹18,600
17 Sept 2026
17 Sept 2026
25 Sept 2026
17 Sept 2026
25 Sept 2026
17 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of a microprocessor-based electromagnetic flow transmitter suitable for the existing electromagnetic flow meter sensor installed at the inlet including labour charges and cost and conveyance of machinery charges etc., complete | 1 | One Number | - | - |
| 2 | Supply, installation, testing and commissioning of a microprocessor-based electromagnetic flow transmitter suitable for the existing electromagnetic flow meter sensor installed at the outlet including labour charges and cost and conveyance of machinery charges etc., complete | 1 | One Number | - | - |
| 3 | Supply and fixing of 1HP Monoblock pumpset with panel board including all Labour Charges etc, complete., | 1 | One Number | - | - |
| 4 | Supply Installation & Commissioning of Weights & Measures Approved Online Continuous Effluent Monitoring System spares - BoD Sensor as per TNPCB Norms Measuring range pH: 0-14pH
• Sensor Type : Inductive Sensor
• Accuracy: +/- 0.01 pH
• Resolution: 0.01pH
• Measuring range ORP: +/-2000mV
• Accuracy: +/- 2mV
• Output 4 -20mA with Relay Output/ RS485/HART
• Mounting: Panel / Field
• Temperature: 0-105°C / 0-6.9Bar
The rate including loading, unloading charges and all Labour Charges etc, complete., | 1 | One Number | - | - |
| 5 | Supply Installation & Commissioning of Weights & Measures Approved Online Continuous Effluent Monitoring System spares - BoD/CoD/TSS Sensor as per TNPCB approved Norms Type - Multi - Parameter Analyser
• Principle - UV-spectroscopy measurement (180 nm to 780 nm Dual Beam entire spectrum)
• Range - 0 -500ppm-COD,)0-500ppm- BOD & TSS-1000ppm
• Overall accuracy - (+/-)2 ppm
• Max Process temperature - 60°C
• Calibration data - Inbuilt calibration & application data storage in Transmitter
• Cleaning - Auto Cleaning
The rate including loading, unloading charges and all Labour Charges etc, complete., | 1 | One Number | - | - |
| 6 | Supply, delivery and fixing of HMI display with updated TNPCB aproved software. The rate including all labour charges etc., Completed | 1 | One Number | - | - |
| 7 | Supply, installation and commissioning of A data acquisition system (DAS) or data logger in an Online Continuous Effluent Monitoring System (OCEMS) is a specialized hardware and software setup that collects, records, and streams 24×7 real-time environmental compliance data from industrial sensors to regulatory bodies like the Central Pollution Control Board (CPCB) and state boards.
Data Collection: Gathers raw electrical or digital signals from gas analyzers, particulate monitors, and flow meters.
Real-Time Transmission: Pushes timestamped data securely to cloud servers and regulatory portals using standard HTTP, HTTPS, or FTP protocols.
Store & Forward Buffering: Stores data locally in tamper-proof, non-volatile memory during network outages and auto-retransmits the backlog once connectivity returns to prevent data gaps.
Compliance & Alarms: Automatically flags limit exceedances, triggers instant alerts, and generates reports required for environmental audits. The rate including all charges etc., Complete as per TNPCB standard specifications. | 1 | One Number | - | - |
| 8 | Supply, delivery,fixing and commissioning of SMPS. The rate including all charges and labour charges etc., Complete as per standard specifications. | 1 | One Number | - | - |
| 9 | Analyzer calibration charges for service shall include checking of sensors/probes, calibration of measuring parameters, verification of readings before and after calibration, minor adjustments and submission of calibration/service report (4 times per year at equal interval) | 4 | One Number | - | - |
| 10 | Flow meter calibration charges with the weight measures certificate the flow sensor and transmitter, checking of flow indication and totalizer, verification of accuracy, necessary calibration/adjustment and testing after calibration. (4 times per year at equal interval) | 4 | One Number | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BIDDOCUMENTOCEMSOANDM.pdf
Tender Documents • 0.71 MB
BOQ_848111.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .