| 1 | L-1₹29.5 LAccepted-AOC | L-1 | Accepted-AOC On L-1 basis | |
| 2 | L-2₹29.5 L+₹4,000 (0.14%)Rejected-Finance | L-2 | Rejected-Finance Rejected. | |
| 3 | L-3₹35.6 L+₹6.1 L (20.7%)Rejected-Finance AHMEDABAD | AHMADABAD | GUJARAT | 363423 | L-3 | Rejected-Finance Rejected. | |
| 4 | L-4₹40.3 L+₹10.9 L (36.9%)Rejected-Finance 126 BOTAHGHULI OPP BOR NAMGHAR PANJABARI GUWAHATI KAMRUP ASSAM 781037 | KAMRUP METRO | ASSAM | 781037 | L-4 | Rejected-Finance Rejected. | |
| 5 | L-5₹58.7 L+₹29.2 L (99.1%)Rejected-Finance NEAR LIONS CLUB KOTHAMANGALAM ERNAKULAM KERALA 686691 | ERNAKULAM | KERALA | 686691 | L-5 | Rejected-Finance Rejected. |
Tender Value
Refer Docs
Closing Date
19 Jan 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Materials Manager
Barauni Kanpur Pipeline, Indian Oil Corporation Limited P.O. Barauni Oil Refinery, Begusarai (Bihar) - 851114
Supply and Installation of Permanent Reference Cells at CP Stations under Bihar and UP Base
2020_BKBRN_129227_1
Bk/TS/900/2020-21/47
Open Tender
Electrical Works
Works
180 days
BKPL Barauni
Please refer tender document
6 documents required · 6 mandatory
Exempted
26 Feb 2021
29 Dec 2020
20 Jan 2021
29 Dec 2020
19 Jan 2021
6 Jan 2021
120 days
Amount
For CP Stations under BKPL Barauni jurisdiction in Bihar State
Supply of XLPE insulated , PVC sheathed Copper Armoured Cable of size 2cx6 sq.mm, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make.
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make.
Supply and installation of vandal proof test 8" dia RCC lead point (TLPs) at location or as per direction of site engineer including supply of proper size of lug, washer & brass nut bolt, Bakelite insulation plate, 2 inch dia GI pipe (B class, lSI marked) of 1.5 mtr length threaded at one end to fit the vandal proof TLP Box & other end with bend pipe connection witha piece of GI pipe taking out from foundation for cable entries.Necessary 6 Sq.mm multi strand PVC insulated flexible double core copper conductor cable for lead wires and all other materials required fo rerecting the test lead point over concrete foundation of 400x400x400 mm (TLP grouting) with cement concrete mixture 1:2:4 (Cement:Sand: Grit of 20mm nominalsize), making cable connection to the pipe with necessary excavation,removing I" x 1" size of existing coating material on pipe surface, cleaning with wire brush and making the surface free of dust, surface preparation by acid wiping, thermit welding/ pin brazing 1" length of Cu strands on exposed pipe surface, filling the exposed pipe and cable portion with liquid araldite (mixed with hardner), & terminating the cable on Bakelite insulating bolt with copper lugs, brass nuts /bolts, washer lugsinside the test lead box enrooting the cable through inside of the TLPbox pipe, including removal of coat & wrap of dimension 75mm X 75mm, repairing the damage to coat & wrap etc. and painting with one coat of Red Oxide zinc chromate primer and two coats of approved brand of synthetic enamel paint on the test lead box and GI pipe, complete in every respect as per drawing, specifications and instructions of Site Engineer inclusive of the cost of all labour, materials etc.
Laying of reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / half cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleeve, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, installation of half cells, backfilling etc., in all types of strata and soil (including rock) by making the trench, laying cable, sand padding and bricks laying and back filling the trench, cable terminations, work complete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engineer-In-Charge and approved drawings.
For CP Stations under BKPL Patna jurisdiction in Bihar State
Supply of XLPE insulated , PVC sheathed Copper Armoured Cable of size 2cx6 sq.mm, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make.
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make.
Supply and installation of vandal proof test 8" dia RCC lead point (TLPs) at location or as per direction of site engineer including supply of proper size of lug, washer & brass nut bolt, Bakelite insulation plate, 2 inch dia GI pipe (B class, lSI marked) of 1.5 mtr length threaded at one end to fit the vandal proof TLP Box & other end with bend pipe connection witha piece of GI pipe taking out from foundation for cable entries.Necessary 6 Sq.mm multi strand PVC insulated flexible double core copper conductor cable for lead wires and all other materials required fo rerecting the test lead point over concrete foundation of 400x400x400 mm (TLP grouting) with cement concrete mixture 1:2:4 (Cement:Sand: Grit of 20mm nominalsize), making cable connection to the pipe with necessary excavation,removing I" x 1" size of existing coating material on pipe surface, cleaning with wire brush and making the surface free of dust, surface preparation by acid wiping, thermit welding/ pin brazing 1" length of Cu strands on exposed pipe surface, filling the exposed pipe and cable portion with liquid araldite (mixed with hardner), & terminating the cable on Bakelite insulating bolt with copper lugs, brass nuts /bolts, washer lugsinside the test lead box enrooting the cable through inside of the TLPbox pipe, including removal of coat & wrap of dimension 75mm X 75mm, repairing the damage to coat & wrap etc. and painting with one coat of Red Oxide zinc chromate primer and two coats of approved brand of synthetic enamel paint on the test lead box and GI pipe, complete in every respect as per drawing, specifications and instructions of Site Engineer inclusive of the cost of all labour, materials etc.
Laying of reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / half cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleeve, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, installation of half cells, backfilling etc., in all types of strata and soil (including rock) by making the trench, laying cable, sand padding and bricks laying and back filling the trench, cable terminations, work complete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engineer-In-Charge and approved drawings.
For CP Stations under BKPL Barauni jurisdiction in Jharkhand State
Supply of XLPE insulated , PVC sheathed Copper Armoured Cable of size 2cx6 sq.mm, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make.
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make.
Supply and installation of vandal proof test 8" dia RCC lead point (TLPs) at location or as per direction of site engineer including supply of proper size of lug, washer & brass nut bolt, Bakelite insulation plate, 2 inch dia GI pipe (B class, lSI marked) of 1.5 mtr length threaded at one end to fit the vandal proof TLP Box & other end with bend pipe connection witha piece of GI pipe taking out from foundation for cable entries.Necessary 6 Sq.mm multi strand PVC insulated flexible double core copper conductor cable for lead wires and all other materials required fo rerecting the test lead point over concrete foundation of 400x400x400 mm (TLP grouting) with cement concrete mixture 1:2:4 (Cement:Sand: Grit of 20mm nominalsize), making cable connection to the pipe with necessary excavation,removing I" x 1" size of existing coating material on pipe surface, cleaning with wire brush and making the surface free of dust, surface preparation by acid wiping, thermit welding/ pin brazing 1" length of Cu strands on exposed pipe surface, filling the exposed pipe and cable portion with liquid araldite (mixed with hardner), & terminating the cable on Bakelite insulating bolt with copper lugs, brass nuts /bolts, washer lugsinside the test lead box enrooting the cable through inside of the TLPbox pipe, including removal of coat & wrap of dimension 75mm X 75mm, repairing the damage to coat & wrap etc. and painting with one coat of Red Oxide zinc chromate primer and two coats of approved brand of synthetic enamel paint on the test lead box and GI pipe, complete in every respect as per drawing, specifications and instructions of Site Engineer inclusive of the cost of all labour, materials etc.
Laying of reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / half cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleeve, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, installation of half cells, backfilling etc., in all types of strata and soil (including rock) by making the trench, laying cable, sand padding and bricks laying and back filling the trench, cable terminations, work complete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engineer-In-Charge and approved drawings.
For CP Stations under BKPL Allahabad jurisdiction in UP State
Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make.
H.R.Mahato
Pollen Technology
SILVERLINE INTEGRITY SERVICES
TechnoCorr Engineering Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .