Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹1.5 LAccepted-AOC | L 1 | Accepted-AOC L1 | |
| 2 | L 2₹1.5 L+₹6,413 (4.41%)Rejected-Finance | L 2 | Rejected-Finance L 2 | |
| 3 | L 3₹1.9 L+₹41,420 (28.5%)Rejected-Finance | L 3 | Rejected-Finance L 3 |
Tender Value
₹1.7 L
EMD Value
₹3,600
Closing Date
21 Jun 2022, 11:00 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, defence Colony, New Delhi 110024
Improvement of E.I at Community Centre Aliganj Jurbag in Kotla Mubarakpur in ward no 60-S under central zone. Sub-Head Provision for E.I and Fans.
2022_SDMC_119202_1
EE(Elect.)/CNZ/2022-23/08-01
Open Tender
Electrical Works
Item Rate
60 days
C-Block, defence Colony, New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹3,600
22 Dec 2023
15 Jun 2022
21 Jun 2022
15 Jun 2022
21 Jun 2022
15 Jun 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a)5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 3 pin 5/6 A socket outlet
upplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 & 2 Module (75 mmX75 mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as requiredb. 4 Module (125 mmX75 mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 8 Module (125mmX125mm)
Installation of exhaust fan in the existing opening ,including making good the damage ,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a). 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
Supplying and fixing following rating ,double pole,24o volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(b) 63 amps
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
P/F 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recess conduit/submain wiring cable as reqd.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply of 10'' (250 mm )sweep, 1250 rpm exhaust fan Fresh air Typecomplete with shutter, blades etc as required.
SITC of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not les than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required.
S/I/T/C of LED Tube Type luminiare 20 Watt rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System Wattage 20 Watt +/- 5%. (b) Luminous Efficieny lumens/watt >= 95 (c ) Power Factor>= 0.95
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required. 2 x 6 sq.mm
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 C),IP-55 weather proof pole box of inner dimension 200 mmx160 mmx98 mm (NS) complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB & 63 A Double pole( MCB/isolator excluded) with neutral link duly shorting on DIN channel with 2 nos.of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc. as required.
SITC of single phase monoblock pumpset complete with all accessories workable of 240 Volts 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pumpset head from 12-30 metre suction and delivery 25X25 mm.
Vikas Electrical Store
The Electrician
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .