Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | ₹4.6 L | L1 | Accepted-AOC AOC |
| 2 | L2₹4.6 L+₹2,343 (0.51%)Rejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | ₹4.6 L+₹2,343 (0.51%) | L2 | Rejected-Finance 2nd lowest |
| 3 | L3₹4.7 L+₹5,448 (1.18%)Rejected-Finance | ₹4.7 L+₹5,448 (1.18%) | L3 | Rejected-Finance 3rd lowest |
| Sl No | Description | Qty | Unit | JASODA REFRIGERATOR SERVICING CENTRE L1 | R.K.ENTERPRISE L2 | M/S. M. R. ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taken down indoor & outdoor unit complete with accessories and cleaning, washing by water and soap solution and re-installation of the 7.5 Tr Split AC machine. | 11 | Each | 3,248 ₹35,728 Lowest | 3,270 ₹35,970 | 3,274 ₹36,014 |
| 2.00 | Taken down indoor & outdoor unit complete with accessories and cleaning, washing by water and soap solution and re-installation of the 2.0 Tr Split AC machine. | 10 | Each | 1,249 ₹12,490 Lowest | 1,250 ₹12,500 | 1,265 ₹12,650 |
| 3.00 | Labour charges for complete dismt. existing compressor and elec. wiring incl. all equipment and refitting the same after necy. repairing etc. | 5 | Each | 1,638 ₹8,190 Lowest | 1,640 ₹8,200 | 1,700 ₹8,500 |
| 4.00 | Supply, installation, testing & commissioning of Scroll Compressor 2.5 Ton capacity and fixed the same in existing position with necessary arrangement to complete the installation as per direction of EIC. | 5 | Each | 29,240 ₹1,46,200 Lowest | 29,245 ₹1,46,225 | 29,300 ₹1,46,500 |
| 5.00 | Supply & fixing new 50W, 620 RPM indoor fan motor for 7.5 ton Concealed split as per sample. | 7 | Each | 2,688 ₹18,816 Lowest | 2,690 ₹18,830 | 2,690 ₹18,830 |
| 6.00 | Supply & fixing new 18W, 930 RPM outdoor fan motor for 7.5 ton Concealed split as per sample. | 5 | Each | 3,175 ₹15,875 Lowest | 3,180 ₹15,900 | 3,250 ₹16,250 |
| 7.00 | Supply & fixing new indoor PCB for 7.5 ton Concealed split as per sample. | 7 | Each | 5,490 ₹38,430 Lowest | 5,500 ₹38,500 | 5,500 ₹38,500 |
| 8.00 | Supply & fixing new outdoor PCB for 7.5 ton Concealed split as per sample. | 6 | Each | 3,980 ₹23,880 Lowest | 4,000 ₹24,000 | 4,200 ₹25,200 |
| 9.00 | Supply & fixing new 3 phase power contactor for 7.5 ton Concealed split as per sample. | 8 | Each | 1,445 ₹11,560 Lowest | 1,450 ₹11,600 | 1,450 ₹11,600 |
| 10.00 | Supply & fixing remote circuit of 7.5 ton concealed split AC machine as per sample. | 11 | Each | 2,475 ₹27,225 Lowest | 2,480 ₹27,280 | 2,500 ₹27,500 |
Tender Value
Refer Docs
EMD Value
₹9,275
Closing Date
24 Jun 2025, 10:55 amClosed
AE/BMCESD/PWD
Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance estimate of the E.I. work at MCH Building of Bankura Sammilani Medical College and Hospital ... Overhaul and Repair of all type of single (1) phase and Three (3) phase AC machines at MCH building under BSMCH, Bankura.
2025_WBPWD_864983_1
WBPWDTE/AE/BMCESD/NIQ-09/Q of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,275
Yes
17 Jul 2026
16 Jun 2025
26 Jun 2025
16 Jun 2025
24 Jun 2025
16 Jun 2025
Amount
Taken down indoor & outdoor unit complete with accessories and cleaning, washing by water and soap solution and re-installation of the 7.5 Tr Split AC machine.
Taken down indoor & outdoor unit complete with accessories and cleaning, washing by water and soap solution and re-installation of the 2.0 Tr Split AC machine.
Labour charges for complete dismt. existing compressor and elec. wiring incl. all equipment and refitting the same after necy. repairing etc.
Supply, installation, testing & commissioning of Scroll Compressor 2.5 Ton capacity and fixed the same in existing position with necessary arrangement to complete the installation as per direction of EIC.
Supply & fixing new 50W, 620 RPM indoor fan motor for 7.5 ton Concealed split as per sample.
Supply & fixing new 18W, 930 RPM outdoor fan motor for 7.5 ton Concealed split as per sample.
Supply & fixing new indoor PCB for 7.5 ton Concealed split as per sample.
Supply & fixing new outdoor PCB for 7.5 ton Concealed split as per sample.
Supply & fixing new 3 phase power contactor for 7.5 ton Concealed split as per sample.
Supply & fixing remote circuit of 7.5 ton concealed split AC machine as per sample.
Supply & fixing new 4 mfd indoor fan motor capacitor for 7.5 ton Concealed split AC machine as per sample.
Supply & fixing new 6 mfd outdoor fan motor capacitor for Concealed split AC machine as per sample.
Supply & fixing Clapper relay for 2.0 ton split AC machine as per sample.
Supply & fixing new 32" x 24" condencing coil for outdoor unit of 2.0 Ton AC machine as per sample.
Nitrogen flashing, Cleaning & Lick Testing of Cu pipe & all system for damaged machine
Supply & Charging full quantity refrigerent Gas (R-22)
R.K.ENTERPRISE (BID ID -6590478)
M/S. M. R. ENTERPRISE (BID ID -6591313)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .