Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹29.5 L+₹3,692 (0.13%)Rejected-Finance 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.9 L+₹45,267 (1.54%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.6 L+₹4.2 L (14.2%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.6 L+₹5.2 L (17.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UTARLAI
GARRISON ENGINEER AIR FORCE UTARLAI PB NO 11 BARMER (RAJ) PIN 344001
REPAIRS AND MAINTENANCE OF SUMMER APPLIANCES, PACKAGE TYPE AC AND DESERT COOLERS AT AF STN UTARLAI
2020_MES_343025_1
8105/03/E8 dt 06 MAY 2020
Open Tender
Civil Works
Item Rate
180 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹80,000
Yes
25 Jun 2020
6 May 2020
3 Jun 2020
6 May 2020
2 Jun 2020
20 May 2020
60 days
Amount
M & L for servicing of Split type AC of capacity 1.5 /2.0 TR of any type by cleaning of filter on front side indoor unit, out door unit including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete and rewriting of MES No of indoor unit and out door unit complete all as specified and directed Note : Refrigerant required for topping (R22 / R-134/R-410(a)/R32) shall be measured and paid for separately .
M & L Refrigerant gas R 22/ R-134/ R-410(a)/R-32 in company sealed cylinder of capacity complete all as specified and directed by Engr-in-charge
S & F in repairs plug and socket outlet industrial type 250 Volts with MCB SP 20 AMP complete all as specified and directed.
S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 5 KVA complete all as specified and directed.
S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 4 KVA complete all as specified and directed.
S&F in rpairs for sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed FRLS copper conductor 1100V drawn through and including rigid heavy duty PVC casing caping 25 mm size with casing/caping accessories including 2.5 sqmm PVC insulated but unsheathed FRLS copper conductor used as earth wire complete all as directed by Engr -in- charge. Note: Two runs of 4 Sqmm and one run of 2.5 Sqmm cable including one run of PVC casing and caping shall be measured as one run
S&F in repairs 3 phase contactor 32 Amps , 420 Volt make Siemens / L&T / C&S floater disconnecting & dismantling existing unserviceable contactor complete all as specified and directed
All as per item Ser No 7 above but 63 Amps capacity complete all as specified.
M & L for servicing of window any type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant up to the required level, complete all as specified and directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 / 134) shall be measured and paid for separately
S&F in repairs aluminum fan blade suitable for condenser of window type AC of 1.5 TR/2.0 TR capacity complete all as specified and directed.
S&F in repairs relay only suitable for window type AC 1.5/02 TR capacities complete all as specified and directed.
S & F in repairs wiring kit of window type AC complete with lugs, thimble complete all as specified and directed
S&F in repairs condenser fan motor of split type AC of 1.5 / 2 TR capacity of make Carrier / Hitachi / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs thermostat suitable for window type AC 1.5/2 TR capacity complete all as specified and directed.
Replacement of following unserviceable item in Split type AC 1.5/2 TR :-
Blade for condensing fan motor
Running Capacitor 6 Mfd
Running Capacitor 36 Mfd (Clip type)
Running Capacitor 2.5 Mfd
Running Capacitor 4 Mfd
Running Capacitor 12 Mfd
S & F in repairs Starting capacitor (ISI Marked), 36 Mfd complete all as specified and directed.
S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity complete all as specified and directed.
S&F in repairs PVC fan blade suitable for condenser fan motor of window type AC of 1.5/ 2 TR capacity complete all as specified and directed.
S&F in repairs indoor unit blower fan motor of split type AC 1.5 TR capacity of make Carrier / Hitachi / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs indoor blower fan motor of split type AC of 2.0 TR capacity of make Carrier / Hitachi / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs hermetically sealed Compressor (Sealed Unit) of water cooler 40/80 ltrs capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge.
All as per item No. 21 above but compressor of water cooler of capacity 150 /200 liters complete all as specified and directed.
S&F in repairs hermetically sealed Compressor (Sealed Unit) of refrigerator 286/ 300/ 310 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge.
All as per item No. 23 above but compressor of refrigerator of capacity 165/175 liters complete all as specified and directed.
S&F in rotary type sealed Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, pressure testing, leakage rectification including gas charging R-22/ R407 & testing complete to the entire satisfaction of Engr-in-charge.
S & F in repairs PCB Sensor unit of split AC indoor unit of Capacity 1.5 /2.0 TR suitable for Videocon,Hitachi, LG, Voltas, Samsung and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed by Engr in Charge.
S&F Cord less type remote with pencil. As required mode Make Hitachi/Voltas/ Godrej/Samsung complete all as specified and directed.
S& F in repairs PVC conduit pipe 25mm dia medium duty including fittings such as bends, elbows, short piece connections caps plugs and unions etc fixed to walls, ceiling or laid in floors For drain out of water from Split type ACs complete all as specified and directed
S & F in repairs split AC indoor unit of Capacity 1.5 TR suitable for Hitachi, LG, Voltas, removing old indoor unit of same make & capacity and model in the same position complete all as specified and directed by Engr-in-Charge. Make: Hitachi/Voltas/Blue star
S & F in repairs split AC indoor unit of Capacity 2.0 TR suitable for Hitachi, LG, Voltas, removing old indoor unit of same make & capacity and model in the same position complete all as specified and directed by Engr-in-Charge.Make: Hitachi/Voltas/Blue star
S&F in repairs Fabricating & Fixing Canopy made out of MS angle iron 60x 60 x 6 mm with GI sheet roofing of suitable size for 2 / 1.50 Ton Cap split A/C Condenser unit duly fixed on window slab/ out side external wall/ building roof of on ground with proper hold fast with PCC 1:2:4 type B-1 using 20mm graded stone aggregate. Angle iron frame duly painted with two coats of black synthetic enamel paint over a coat of red oxide and complete all as specified and directed
S&F in repairs Rotary type sealed Compressor (Sealed Unit) of split type AC 2.0 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge.
S&F in repairs condenser fan motor of water cooler of 40/80 ltrs capacity of make Carrier / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs condenser fan motor of water cooler of 60/120 ltrs capacity of make Carrier / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs condenser fan motor of water cooler 150 ltrs capacity of make Carrier / Voltas / Blue star, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs starting capacitor 80/100 mfd suitable for water cooler of any capacity complete all as specified and directed. Make : EPCOS/ ASIAN/ Sharada
S&F in repairs running capacitor 36/45 mfd suitable for water cooler of any capacity complete all as specified and directed. Make : EPCOS/ ASIAN/ Sharada
S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and directed. Make : DANFOSS /INDOFOSS
S & F in repairs relay with over load protector suitable for 40 to 150 ltrs capacity water cooler complete all as specified and directed
Shifting of Split type AC indoor and outdoor unit of any TR capacity complete all as specified and directed by Engr -in- charge
Shifting of Window type AC of any TR capacity complete all as specified and directed Engr -in- charge
S&F in repairs of Drain pipe as per existing size/make for fixing to indoor unit water drain out complete all as specified and directed by Engr -in- charge
S&F in replacement of refrigerant pipe or tube (copper) size 5/2"for split type Ac 1.5/ 2.0 TR complete all as specified directed by Engr -in- charge
S & F in replacement of safety valve of compressor line as per existing makes and sizes complete all as specified and directed by Engr -in- charge
S&F in replacement Desert Cooler fan motor capacity 1/5 HP three speed, 1400 RPM single phase stand complete, including angle iron support all as specified and directed.
S&F in replacement water lift submersible pump plastic body of 220-240 Volts AC Supply single phase 40 watt complete all as specified and directed.
S&F in replacement PVC elbow suitable for desert cooler as per existing size /make complete all as specified and directed
S&F in replacement 3 pin plug top of capacity 5 Amp AC 240 Volts 50 Hz ccomplete all as specified and directed
S & F in repairs ply wood with commercial face of 5 ply 6mm thick BWR grade for packing of AC and Desert cooler complete all as specified and directed
S & F in repairs plastic fan blade for fan motor of desert cooler 300 mm sweep complete all as specified and directed.
S&F in repairs capacitor 4 MFD for fan motors of desert coolers complete all as specified and directed. Make : EPCOS/Asian/Sharda
S&F in replacement side penal (shutter) made out of 22 gauge PGI Sheet with suitable hand grip,and supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers including painting to match with the existing desert cooler complete all as specified and directed
M & L in repairs for electronic voltage stabilizer 10 KVA with suitable relay, transformer and connecting accessories complete all as specified and directed
M & L in repairs for Foam type insulating flexible pipe for suction / discharge copper tubes complete all as specified and directed.
S&F in repairs 20mm size of Ball valves high pressure of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe and fixed.including nipple and fixing accessories complete to the entire satisfaction of Engr-in-charge. (Minimum weight 20mm-210gms)
S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wire mesh of 20 Gauge wire and mesh size 100 x 100 mm complete all as specified and directed
M & L in repairs for PVC connections 15mm size with PTMT nuts length 450 mm long including connection with Desert cooler and existing pipe line complete all as specified and directed by Engr-in- Charge.
M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparation and cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. complete all as specified and directed
M.D. CONSTRUCTION CO.
National Rewinding Works
Hariom Construction Company
RAIKA ENTERPRISES
Rasam Engg Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .