Dy. CEO (P)
SMVDSB, Katra
Construction of Archery Office and CGI Shed for store of Archery equipment at Sports Complex, Katra
2026_SMVSB_306156_1
e-NIT No. CO/DEV/700/7795 DT 14.03.2026
Open Tender
Civil Works
Percentage
60 days
SMVDSB, Katra
refer bid document
4 documents required · 4 mandatory
₹1,000
FA/CAO, SMVDSB
₹32,150
31 Mar 2026
14 Mar 2026
31 Mar 2026
14 Mar 2026
30 Mar 2026
14 Mar 2026
Civil Works
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of buttons lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: Ordinary Rock (50 meter beyond 1 mtr from cutting edge).
Disposal of excavated earth with mechanical transport within 5 km lead
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
a) 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
b) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work, in beams, suspended floors, roofs having slope upto 15o, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:11/2:3 (1 cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
FORM WORK Centring and shuttering including strutting, propping etc. and removal of form for:
a) 5.9.1 Foundations, footings, bases of column etc. for mass concrete.
b) Lintel, beams, plinth beams, girders, bressumers and cantilevers
c) Suspended floors, roofs, landings, balconies and access platforms
d) Under 20 cm wide
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in:
a) Cement mortar 1:6
b) Extra for brick work with common brunt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level.
c) Extra for brick work in: Square or rectangular pillars
d) Half brick masonry Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 (1 cement : 3 coarse sand)
e) Extra for half Brick masonry in superstructure above plinth level upto floor V level
f) Extra for providing and placing in position 2 Nos. 6mm dia, M.S. bars at every third course of half brick masonry
15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement : 4 fine sand)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams / liter.
Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter / 10sqm over and including priming coat of water exterior paint applied @ 2.20 kg / 10 sqm.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete. 50 mm thick with 20 mm nominal size stone aggregate.
Providing and laying vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 600 x 600 mm
DAMP PROOF COURSE Providing & laying camp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg 12.5 mm nominal size) and curing complete.
C.G.I. SHEETS ROOFING Providing corrugated G.S. Sheet roofing including vertical / curved surface fixed with plymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gram / m2.
Providing and fixing 1 mm thick M.S sheet door with frame of 40 x 40 x 6mm for diagonal braces.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M/S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixed with dash fastener or required dia and size including necessary filling up of gaps at junctions i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (glazing, panelling and dash fasteners to be paid for separately.)
a) Powder coated aluminium (minimum thickness of powder coated 50 microns)
b) Tower Bolt (9.99.5
c) Eye Hooks (150 mm )
d) Door Stopper (9.83)
e) Handle (22.16.2)
f) Handle (22.12.1)
g) Hinges
h) ACP sheet (5 mm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item). With float glass panes of 5.0 mm thickness (weight not less than 12.50 Kg/Sqm).
Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete with 12 mm mild steel U beading.
Carriage of material through mechanical transport
a) Sand (55 Km)
b) Aggregate (25 Km)
c) Bricks (60 Km)
Electrical Works (WIRING)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. - Group-C
Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
2x2.5 sq. mm + 1x2.5 sq. mm earth wire
2x4 sq. mm + 1x4 sq. mm earth wire
2x6 sq. mm + 1x6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm Conduit
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (Make: - Legrand (Mylinc) / Havell's (Coral)
5/6 Amp. Switch Modular
Modular Switch 15/16 Amp.
3 pin 5/6 Amp Socket outlet Modular.
Modular Socket 6 pin 15/16 Amp.
Modular Bell Push
Fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make: - Legrand (Mylinc) / Havell's (Coral)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make: - Legrand (Mylinc) / Havell's (Coral)
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
Wiring/Supply and fixing 20A, 240V, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alogwith 20A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (For AC)
MCCB, MCB & DB’s
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - ABB/ Schinder/ Legrand/ L&T) 12-way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: - ABB/ Schinder/ Legrand/ L&T)
Single pole
Single pole and neutral 40/63 Amp.
INSTALLATION, TESTING AND COMMISSIONING Supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
LED Tube fitting 20 Watt 4 feet long. (Batten 4')
LED Surface Mounted ceiling light 12 watt
Supply, Installation, Testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
Supply, Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
CABLING
Supply, Installation, Testing and Commissioning of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required XLPE cable 2 core 16 sq.mm (Armourde)
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
BOQ_994187.xls
BOQ • 0.40 MB
AddendumSportsComplex.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .