Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.8 CrAccepted-AOC | ₹3.8 Cr | 1 | Accepted-AOC Being lowest tender |
| 2 | 2₹7.2 Cr+₹3.4 Cr (89.9%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹7.2 Cr+₹3.4 Cr (89.9%) | 2 | Rejected-Finance not being lowest tender |
| 3 | 3₹8.2 Cr+₹4.4 Cr (114.3%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR | DELHI | EAST DELHI | DELHI | 110092 | ₹8.2 Cr+₹4.4 Cr (114.3%) | 3 | Rejected-Finance not being lowest tender |
| 4 | 4₹8.6 Cr+₹4.8 Cr (126.0%)Rejected-Finance | ₹8.6 Cr+₹4.8 Cr (126.0%) | 4 | Rejected-Finance not being lowest tender |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
31 Mar 2021, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CE DELHI ZONE DELHI CANTT-10
IMPROVEMENT AND AUGMENTATION OF WATER SUPPLY AND ELECTRIC SUPPLY, DISTRIBUTION SYSTEM FOR MD ACCN OF CAO POOL AND OTHER AREAS DELHI CANTT-10
2020_MES_362254_4
CEDZ-10 OF 2020-2021
Open Tender
Civil Works
Lump-sum
540 days
DELHI CANTT
MES contractor enlisted in MES under class A cat a i having deposited Standing Security of Rs 7.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹2,000
GE (P) EAST DELHI CANTT
₹4.7 L
Yes
21 May 2021
16 Mar 2021
2 Apr 2021
16 Mar 2021
31 Mar 2021
17 Mar 2021
Amount
Total amount of Schedule 'A' Section I (Construction of Semi under ground sump) (Ref pre priced Schedule attached seperately)
Schedule 'A' Section II (Demolition of OHTs) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 1 Dismantling of RCC OHT of capacity 1.00 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Basantar Range, complete all as specified and directed.
Item No. 2 Dismantling of RCC OHT of capacity 1.00 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Chitral Line, complete all as specified and directed.
Item No. 3 Dismantling of RCC OHT of capacity 0.50 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Cavalary Hills, complete all as specified and directed.
Item No. 4 Dismantling of RCC OHT of capacity 0.25 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at New Pratap Chowak, complete all as specified and directed.
Item No. 5 Dismantling of RCC OHT of capacity 0.50 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at CVD Depot, complete all as specified and directed
Item No. 6 Dismantling of RCC OHT of capacity 2.00 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Old Basant Range, complete all as specified and directed
Item No. 7 Dismantling of RCC OHT of capacity 0.25 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at 1 CBPO , complete all as specified and directed
Item No. 8 Dismantling of RCC OHT of capacity 1.00 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces of RCC Shaft Type OHT at Rajputana Rifles Regtl Centre, complete all as specified and directed.
Item No. 9 Dismantling of RCC OHT of capacity 0.50 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Old APS Colony , complete all as specified and directed.
Item No. 10 Dismantling of RCC OHT of capacity 1.00 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Signal Group No 1, complete all as specified and directed
Item No. 11 Dismantling of RCC OHT of capacity 0.30 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at Signal Group No 1, complete all as specified and directed
Item No. 12 Dismantling of RCC OHT of capcity 0.25 LG (Reinforcement from dome, shaft, column & beam etc) carefully & taking necessary safety precautions and removing the same to a distance 5.00 km and making good disturbed ground surfaces at TPT Coy, complete all as specified and directed
Sub-Total
Total amount of Schedule 'A' Section III (Part-I) (External Water Supply) (Ref pre priced Schedule attached seperately)
Schedule 'A' Section-III (Part-II) (External Water Supply ) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Item No. 01 Taking down existing CI water mains of 100 mm bore on vertical along the overhead tank shaft including all fitting/fixtures complete all as specified and directed.
Item No. 02 All as per item No 01 above but 150 mm bore.
Item No. 03 All as per item No 01 above but 200 mm bore
Item No. 04 All as per item No 01 above but 250 mm bore
Item No. 05 S&F CI foot valve of follwing sizes, lift and swing type single type incluing nuts, bolts, washers and rubber insertion sheet complete all as specified and directed.
(a) 80 mm(6") dia
(b) 100 mm(6") dia
(c) 150 mm(6") dia
Item No. 06 Construciton of valve pit chamber having internal dimension 120 cm x 120 cm (intenral height) using PCC 1:4:8 type D2 (using D2 40 mm graded stone aggregate ) for foundation 15 cms thick 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC(1:2:4) type B1 (using 20 mm graded crushed stone aggregate ) for grouting MS frame including 3 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with doble key arrangment, MS frame including 50 mm pad lock with double key arrangment. MS frame made out 40 x 40 x 6mm thick angle iron including painting of steel surface with two coats of red oxide primer including necessary excavation in any type of soil returning, fitting in and removal of surplus soil to a distance not exceeding 50 mtr including demolition, dismentling of existing valve chamber complete all as specified and directed.
Item No. 07 Taking up or down sluice valve of follwing bore complete all as per specified and directed.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
Item No. 08 Supply, laying and testing Ductile Iron Pipe, 100 mm bore single socket including specials class "K-7" complete all as specified and directed
Sub-Total
Shivom Projects Private limited
VED PRAKASH ARORA
pooja construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .