Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.0 L+₹54,834 (1.55%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.1 L+₹3.7 L (10.4%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹39.5 L+₹4.0 L (11.3%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹40.1 L+₹4.7 L (13.1%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
25 Sept 2024, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS AND MAINTENANCE OF CENTRAL TYPE AC PLANT CHILLER PLANT DUCTILE ACs AND SPLIT ACs AT CASDIC AND RTC UNDER GE I R N D EAST BANGALORE
2024_MES_668228_1
8538/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹92,000
Yes
29 Oct 2024
30 Aug 2024
2 Oct 2024
30 Aug 2024
25 Sept 2024
13 Sept 2024
30 Aug 2024 - 12 Sept 2024
Amount
Supply and fix in replacement of unserviceable micro processor PC board with new microprocessor PC board on any type of AC like existing / invertor type split AC / Cassette Type AC by dismantling / disconnecting the same carefully without disturbing other components upto 3 TR capacity AC including making necessary fixing arrangement etc., complete all as specified and as directed. Make : LG / Carrier / Voltas / Bluestar / Hitachi / Samsung
Material and labour for dismantling of split AC complete inner and outer unit upto 3TR after removing all connection like refrigerant pipe / voltage stabiliser safely and rexing the same at the other location including making all connection and testing in on position complete all as specified and as directed. NOTE : Rate quoted by contractor shall deemed to include for core cutting / wall cutting including making hole for refrigerant pipe etc. No extra items except refrigerant gas and copper pipe if required shall be paid.
Supplying and laying in repairs copper refrigerant pipe copper tube 5/8 " x 3/8" complete all as specified and as directed.
Supply and fix in repairs copper refrigerant pipe copper tube 1/2 " x 1/4" complete all as specified and as directed.
Supply and fix in repairs copper refrigerant pipe copper tube 5/8 " x 1/4" complete all as specified and as directed.
Material and labour for removing the split type air conditioner outdoor unit / indoor unit from its position for pressure / leak testing with dry nitrogen gas and arresting the leakages in condenser coil / cooling coil by brazing etc and gas charging as per required basis complete for Split type AC 1.5 ton / 2.0 ton / 3 TR complete all as specified and as directed. NOTE : Rates quoted by the contractor shall includes for refrigerant gas charging as per required basis.
Material and labour for complete servicing after pumping down Indoor / outdoor units of split AC complete by cleaning condenser / evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat and other electrical / refrigerant controls, cleaning the air filter for split air conditioner upto 2 TR complete all as specified and as directed. NOTE :- (i) The rate deemed includes for minor spares (ii) Gas shall be measured and paid separately under relevant item.
All as per Sl Item No 7 above but for 3 TR capacity cassette / tower type AC
Supply and fix in replacement of unserviceable starting capacitor of 100 / 120 mfd suitable for split / window type air conditioner upto 3 TR complete all as specified and as directed.
Supply and fix in replacement of running capacitor 25 / 36 / 45 / 50 mfd suitable for window / split type air conditioners up to 3 TR capacity complete all as specified and as directed.
All as per Sl Item No. 10 above but for 5.5 to 8.5 TR capacity split / multi split / tower / ductable type AC
Disconnecting and taking down unserviceable internal wiring of split type air conditioner upto 3 TR capacity, supply and rewiring with copper conductors including testing and commissioning complete all as specified and as directed.
Removing defective unserviceable fan blades from split type air conditioners up to 3 TR capacity, supply and fix new blade suitable for air conditioners of existing make of LG / Blue Star / Voltas / Carrier complete all as specified and as directed.
Material and labour for time delay timer cum single phase preventer suitable for 2 TR / 3 TR capacity any make and any model of split type AC including taking down unserviceable timer etc., complete all as specified and as directed. Make : L&T / GIC / BCH / Minilec
Supply and lay PVC insulated cable flexible type with copper conductor 4 sq.mm 3 core suitable for window / split type air conditioner upto 3 TR capacity of length 3 mtr complete all as specified and as directed.
Supply and charging of refrigerant gas R-407C / /R-32. MAKE :-Fluron / Mettron / Refron
Supply and fix MS iron stand with nuts bolts stable for 1.5 / 2TR split type and connected works complete all as specified and as directed by Engineer-in-Charge
Supply and fix in replacement of new hermetically / rotary / receprocating sealed compressor for 1.5 TR capacity split type AC including removing of unserviceable sealed compressor unit etc complete all as specified and as directed. MAKE :- Emerson / Tecumshah / Total line
All as per Sl Item No 18 above but of 2 TR capacity
Supply and fix in replacement metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 40 Amps MCB complete all as specified and as directed.
Material and labour for removing defective unserviceable condensing coil fan motor from split type air conditioners up to 3 TR capacity, supply and fix new condensing coil fan motor suitable for air conditioners upto 3 TR complete all as specified and as directed.
Material and labour for removing defective unserviceable blower fan motor indoor unit from split type air conditioners of 3 TR capacity, supply and fix blower fan motor unit suitable for split air conditioners upto 3 TR complete all as specified and as directed.
Supply and fix in replacement insulating the suction / discharge line of split type air conditioner upto 3 TR capacity with necessary insulating filter wool 6mm thick upto 3 mtr length complete all as specified and as directed.
Supply and fix contactor 240 volts upto 32 Amps suitable for split / ductable / tower type AC capacity upto 8.5 TR including dismantling of existing contactor complete all as specified and as directed. MAKE :- Havells / LG / L&T / BCH
Dismantling unserviceable cooling coil from 1.5 / 2 / 3 TR capacity split AC carefully without damaging the other parts, supply and fix new cooling coil made out from seamless hard copper pipe including brazing and pressure testing dry nitrogen gas including charging any type of refrigerant gas as per existing AC, testing, commissioning, etc suitable for make LG / Bluestar / Voltas / Carrier complete all as specified and as directed.
Supply and fix replacement PVC insulated cable flexible type with copper conductor of size 2.5 sq.mm 4 core suitable for window / split type air conditioner upto 3 TR for connecting to indoor to outdoor unit capacity upto 5 Mtr length complete all as specified and as directed.
Material and labour for pressure testing and rectifying leakage in the system of ductable split air conditioner / cassette type AC / package type / VRF / VRV type upto 8. 5 TR capacity by brazing including copper tubing if required upto 1.5 Mtr length and including gas charging, testing for satisfactory performance, commissioning complete all as specified and as directed.
Material and labour for removing defective PC board carefully without disturbing the cooling coil and fan motor of upto 3 TR air conditioner and taking to reputed workshop check thoroughly and rectify the fault including replacement of IC transformer and connected accessories and refixing back to original position including testing and commissioning etc complete all as specified and as directed.
Material and labour for preventive maintenance of 14 Nos AHU cooling coil by taking out pre filters, cleaning of cooling coil and cleaning of AHU and cleaning of dampers refixing all removed parts, checking the operations of all safety devices, cleaning of electrical contacts, checking the electric circuits, testing, commissioning etc installed at CASDIC complete all as specified and as directed by Engineer-in-Charge.
Material and labour for dismantling 1 Nos of screw compressor from 250 TR capacity chiller carefully with using hydraulic jack and chain pulley, putting dummy plates to suction and discharge line and transporting to authorized workshop for repair, etc and refixing the same in the original place all as specified and as directed at CASDIC.
Material and labour for dismantling of burnt out stator from screw compressor body, cutting, opening of burnt-out winding, rewinding with the same gauge of copper conductor of F class oil proof insulation applying one coat of varnish and kept at the electric oven and heated for 48 hours and refixing the same in the stator bringing back to site all as specified and as directed at CASDIC.
Material and labour for pressure testing each circuit of carrier make 30GX model chiller for refrigerant leak by evacuating refrigerant gas from the circuit into the empty cylinder, leak testing of the circuit with dry nitrogen (N2) pressure by separating the entire system like low side, high side compressor condensers and rectifying the leakage vacuuming re-charging of evacuated refrigerant gas and testing complete all as specified and as directed. NOTE : Topping up of gas will be measured separately for CASDIC
Material and labour for complete overhauling of one 06 NA Compressor in 250 TR chiller unit by opening the compressor end plate, removing the gear assembly with gear puller, removing the hydraulic chamber, removing the twin screws using puller, removing the bearing sets, O rings, rotor, terminal bolts and stator. Clean the entire mechanical parts with approved cleaning agent and oil the parts. Checks all the mechanical parts for wear and tear and replace if required. Reassemble the dismantled parts carefully by using required tools and tackles. Refix the twin screws and checks the alignment of screws for smooth operation. Refix the stator along with terminals, fix the gear assembly and hydraulic chamber. Checks the alignment of screws and gear assembly for smooth rotation. Refix the endplates and tightened the bolts and complete the overhauling all as per standard procedure.
Material and labour for dismantling of winding from defective condenser fan motor of capacity upto 5HP and rewinding, with the same gauge of copper conductor and kept at electrical oven and heated for 48 hours and refixing the same in original place complete all as specified and as directed at CASDIC.
Material and labour for general servicing and preventive maintenance of the 250 TR chiller unit. Pressure cleaning of the condenser coil, checking the operations of all safety devices, cleaning of electrical contacts, checking the electric circuits complete all as specified and as directed at DARE.
Material and labour for painting with one coat of enamel paint for complete central type AC plant of capacity 250TR completely to all connected items of the plant, motors with different colour including motor of blowers / pipes lines with different colour all as directed by Engineer-in-Charge.
Supply and fix in replacement of dual core internal oil filter suitable for 250 TR capacity chiller unit of carrier at CASDIC complete all as specified and as directed. Make : Filtration Level - 3 µ, No. 06NA660028S
Supply and fix in replacement of external oil filter suitable for 250 TR capacity chiller unit of carrier at CASDIC complete all as specified and as directed. Make : Filtration Level - 10 µ. No. 30GX417132E
Supply and fix in replacement of drier suitable for 250 capacity chiller liquid line. No. XW12EA003 at DARE complete all as specified and as directed.
Supply and fix in replacement of Oil level switch suitable for 250 capacity chiller at CASDIC complete all as specified and as directed.
Supply and replacement of Carrier make HP transducer. No. OP12DA039EE complete all as specified and as directed.
Supply and replacement of Carrier make LP transducer. No. OP12DA040EE complete all as specified and as directed.
Supply and replacement of Carrier make Oil pressure transducer. No. OP12DA040EE complete all as specified and as directed.
Supply and replacement of Carrier make Temperature Sensor. No. 30RB 660 036 complete all as specified and as directed.
Supply and replacement of internal bearings suitable for carrier 6 NA screw compressor by opening the compressor end plate, removing the gear assembly with a gear puller, removing the hydraulic chamber, removing the twin screws using a puller, removing the bearing sets, O rings, rotor, terminal bolts, and stator. Clean the entire mechanical parts with an approved cleaning agent. Replace the bearing sets as per the standard procedure. Reassemble the dismantled parts carefully by using the required tools and tackles. Refix the twin screws and checks the alignment of screws for smooth operation. Refix the stator along with terminals to fix the gear assembly and hydraulic chamber. Checks the alignment of screws and gear assembly for smooth rotation. Refix the endplates and tightened the bolts all as per the standard procedure for CASDIC complete all as specified and as directed.
Supply and replacement of topping up of compressor oil suitable for carrier make screw compressor oil (SW 220 grade Synthetic Screw Compressor Oil) for at CASDIC complete all as specified and as directed.
Supply and replacement charging of 134A refrigerant gas for carrier screw chiller at a CASDIC complete all as specified and as directed.
Supply and replacement of defective contactor for the condenser fan motor (Siemens make 3RT1016 Contactor, 3 pole,10 Amps) for Carrier GX model Chillers at CASDIC complete all as specified and as directed.
Supply and replacement of defective bearings of the condenser fan motor. No. 6204, 6205 at CASDIC complete all as specified and as directed.
Supply and replacement of defective contactor with new contactor for compressor 160 A, 3 Pole . (Make: Siemens 3TF51) complete all as specified and as directed.
Supply and replacement of defective contactor with new contactor for AHU motor 100 A, 3 Pole . (Make: Siemens 3TF48) complete all as specified and as directed.
Supply and replacement of defective contactor up to 50A, with new contactor. (Make: L&T, Siemens, ABB) complete all as specified and as directed.
Supply and replacement of defective EXV board of 30GX model Carrier make screw chiller by Isolation the power to the chiller unit, remove the connections to the EXV board carefully, remove the EXV board from the chiller control panel, Fix the new EXV board carefully and reconnect the connections to the EXV board all as per the standard procedure complete all as specified and as directed at DARE .
Supply and replacement of defective flow sensor of 30GX model Carrier make screw chiller by Isolating the Butterfly valve, remove the electrical connection carefully, remove the Flow sensor from the chilled water pipe line, fix the new flow sensor carefully and reconnect the electrical connections to the flow sensor all as per standard procedure complete all as specified and as directed at CASDIC.
Supply and replacement of defective Electronic Expansion valve of 30GX model carrier make chiller by isolation the power to the chiller unit, removing the connections of electronic expansion valve carefully, isolate the refrigerant by closing the services valve, de-braze and removing the valve from ckt, fixing of new valve in the ckt with brazing, pressure testing the ckt, reconnecting the connections to the valve all as per standard procedure complete all as specified and as directed at CASDIC.
Supply and replacing of defective 22KW VFD of chiller water pump by isolation the power to pump panel removing the connections to VDF carefully, fix with new VDF reconnect the connections and re-commission the VDF al as per standard procedure, Make:- SEIMENS, Model SED222/32B or equivalent complete all as specified and as directed at CASDIC.
Supply and replacement of removable type factory made metallic pre-filter of 20 microns of standard size with GI frame both side including removing of unserviceable metallic pre-filters complete all as specified and as directed. Make : AEROSOL / MAF / DYNA / JOHN FLOWER
Supply and replacement of factory made high performance bag filters of 95% down to 5 micron of standard size with multiple-pockets and self supporting filter bags with MS / GI / anodised aluminium frame suitable for central air conditioning plant including replacement of bolt nuts and taking out unserviceable bag filters complete all as specified and as directed by Engineer-in-Charge. Make: Aerosol / John Flower / Dyna / Sri Sai
Material and labour for disconnecting and removing of the induction motor from the existing position of 5 HP to 7.5 HP capacity of any make checking of the motor for its serviceability and transporting to workshop, opening up, cutting and removing of the burnt out winding, rewinding with same gauge of copper conductor insulating, varnishing, greasing etc., complete, reassemble, testing at work shop bring back to site re-fixing back in the original position reconnecting, testing and commissioning complete all as specified and as directed.
All as per Sl Item No 59 above but 7.5 HP to 10 HP capacity induction motor
All as per Sl Item No 59 above 10 HP to 20 HP capacity induction motor
Material and labour for disconnecting and removing of the pump from the existing position of 20 HP to 30 HP capacity of any make checking of the motor for its serviceability and transporting to workshop, opening up, cutting and removing of the burnt out winding, rewinding with same gauge of copper conductor insulating, varnishing, greasing etc., reassemble, testing at work shop bring back to site re-fixing back in the original position reconnecting, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of bearing of 5 HP to 7.5 HP capacity induction motor including removing of unserviceable bearing complete all as specified and as directed.
All as per Sl Item No 63 above but 7.5 HP to 10 HP capacity induction motor
All as per Sl Item No 63 above but 10 HP to 20 HP capacity induction motor
Supply and fixing in replacement of bearing of 20 HP to 30 HP capacity pump including removing of unserviceable bearing complete all as specified and as directed.
Supply and fix in replacement overload relay upto 32 Amps capacity including taking down unserviceable overload relay etc complete all as specified and as directed.
All as per Sl Item No 67 above but capacity 63 Amps to 100 Amps
Supply and fix in replacement water pressure gauges of 4" or 2” dia of the following range with necessary flare nuts, adopter including removing of the unserviceable complete all as specified and as directed. MAKE :- KI / FEIBIG / H GURU. 0-150 PSI or equivalent in Kg/cm2
Supply and fix in replacement of V-belts of the following sizes (in inches) including removing unserviceable belt complete all as specified and as directed. MAKE :- FENNER / DUNLOP / VITTON / PIX
Upto B-120
Upto C-120
Upto A-36
Supply and fix in replacement syphon connection 15mm dia made out of SS pipe suitable for fixing of pressure gauge including ½ an inches dia stop valve and taking down unserviceable syphon connection etc complete all as specified and as directed.
Supply and fix water pressure cut out 0-8 Kg pressure 15mm dia including taking out unserviceable water pressure gauge etc complete all as specified and as directed.
Supply and replacing of defective VFD up to 15 KW of AHU panel removing the connections to VFD carefully, fix with new VFD reconnect the connections and re-commission the VFD all as per standard procedure complete all as specified and as directed. Make : SEIMENS or equivalent.
15 KW VFD
11 KW VFD
Supply and replacing of defective mixing valves of AHU, pumps, removing carefully, fix with new mixing valves all as per standard procedure complete all as specified and as directed.
2 way mixing valve with Actuator Make : Siemens / Johnson Controls
3 way mixing valve with Actuator Make : Siemens / Johnson Controls
Supply and replacement of door beeding for Carrier Chiller control panel complete all as specified and as directed.
R Tech Mech (BID ID -3113504)
M/S J J ENTERPRISES (BID ID -3098594)
Glacier Cooling Solutions Private Limited (BID ID -3099409)
RASI AND COMPANY (BID ID -3113132)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .