Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹116.3 CrAccepted-AOC | ₹116.3 Cr Quoted ₹116.9 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹117.2 CrRejected-Finance PLOT NO 16 OPP METRO PILLAR NO 190 PASCHIM VIHAR EXTENSION ROHTAK ROAD DELHI 110 063 | ₹117.2 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | Rejected-Technical L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | - | - | Rejected-Technical NOT RECOMMENDED |
| 4 | Rejected-Technical 126 A JAIPUR HOUSE AGRA 282010 PH NO 0562 2810176 9897638555 | - | - | Rejected-Technical As per Court order for the hearing that took place on 31 May 2022. |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENDED |
Tender Value
₹114.5 Cr
EMD Value
₹15 L
Closing Date
25 Feb 2022, 6:00 pmClosed
CHIEF ENGINEER
HQ CE(AF) WAC PALAM DELHI CANTT-10
PROVISION OF WORK SERVICES FOR PROJECT GHAGGHAR AT AF STATION ADAMPUR
2021_MES_496830_1
CEWAC/ADM/T-12/2021-22
Open Tender
Civil Works
547 days
GE (AF) ADAMPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) ADAMPUR
₹15 L
Yes
HQ CE(AF) WAC PALAM
2 Jun 2022
23 Dec 2021
4 Mar 2022
23 Dec 2021
25 Feb 2022
11 Feb 2022
23 Dec 2021 - 23 Jan 2022
25 Jan 2022
Amount
SCHEDULE `A' PART - I is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Design and Construction of RCC framed structure garages for SAMC- I and SAMC-II (Each of Area 3030 Sqm, 8M clear height) with Electromechanical rolling shutters,(Height of shutter shall be matched with the height of garage as approved ) on both side of each and every bay (20 Nos bays) of each garage including Pavement Quality Concrete (PQC) flooring as specified with permanent specifications as per tender provision and area as shown in line plan complete all as specified. Note:- (i) Hardstanding shown on line plan all arround building shall be measured and paid for separately under respective items. (ii) The layout of columns shall be strictly as shown on line plan. The cross section of columns may vary as per approved design but clear spacing between columns and clear height of garages shall be strictly as per line plan. (iii) Contractor has to quote for 01 (one) garage and multyply by 3 to arrive at total quoted amount for BOQ item No 1.01.
Design and Construction of RCC framed structure garage for SAMC-I, Garage No-II ( Area 2700 Sqm, 8M clear hight) with Electromechanical rolling shutters, (Height of shutter shall be matched with the height of garage as approved) with 18 Bay each side on each bay of garage including Pavement Quality Concrete (PQC) in flooring as specified with permanent specifications as per tender provision and area as shown in line plan complete all as specified. Note:- Hardstanding shown on line plan all arround building shall be measured and paid for separately under respective items. (ii) The layout of columns shall be as shown on line plan. However, cross section of columns may vary as per approved design but clear spacing and height shall be strictly as per line plan
Design and Construction of RCC framed structure for Storing Auxilary Facilities (SAF) Covered Parking Garages ( Area 1700 Sqm & clear height 8 Mtrs) including 01 Nos Electromachanical Rolling shutter (Height of shutter shall be matched with the height of garage as approved ) on one side on each and every bay (17 bays) including Pavement Quality Concrete (PQC) flooring as specified with permanent specifications as per tender provision and area as shown in line plan complete all as specified. Note:- (i)Hardstanding shown on line plan all arround building shall be measured and paid for separately under respective items. (ii) The layout of columns shall be strictly as shown on line plan. The cross section of columns may vary as per approved design but clear spacing between columns and clear height of garages shall be strictly as per line plan .
Design and Construction of Block of POL store (S/S) building ( Area 18.60 sqm ) with permanent specifications as area shown in line plan complete.
Design and Construction of guard rest room for 4 ORs alongwith toilet (S/S ) Building (Area 56.95 Sqm) with permanent specifications as area shown in line plan complete.
Design and Construction of office cum rest room for 10 technical staff alongwith toilet and verandah (S/S) Building ( Area 107.10 Sqm) with permanent specifications and area shown in line plan complete.
Design and Construction of Sentry Post (S/S) Building ( Area 4.25 Sqm) with permanent specifications as area shown in line plan complete.
Design and Construction of POL CUM Technical store S/S Building ( Area 30.03) sqm) with permanent specifications as area shown in line plan complete.
Design and Construction of office cum rest room for 08 technical staff alongwith toilet S/S Building (Area 88.40 Sqm ) for Igloo Complex with permanent specifications as area shown in line plan complete.
Design and Construction of Single living Accn (G+1) with stair case for 35 Airmen with permanent specifications as area shown in line plan complete.
Design and Construction of Single living Accn (G+1) with stair case for 24 Sargents with permanent specifications as area shown in line plan complete.
Design and Construction of RCC framed structure Parking Shed for 75 Scooters ( Area 172.5 Sqm ) with permanent specifications as area shown in line plan complete.
Design and Construction of RCC framed structure Parking Shed for 35 Scooters ( Area 85.50 Sqm ) with permanent specifications as area shown in line plan complete.
Design and Construction of RCC framed structure Parking Shed for 24 Scooters ( Area 52.20 Sqm ) with permanent specifications as area shown in line plan complete.
Design and Construction of RCC framed structure Parking Shed for 15 Cars ( Area 332.06 Sqm ) with permanent specifications as area shown in line plan complete.
Design and Construction of RCC framed structure Parking Shed for CO Vehicle ( Area 24.06 Sqm ) with permanent specifications as area shown in line plan complete.
Construction of Static Water Tank (SWT) 50000 Glns, complete all as specified and as shown on drawing.
Construction of RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffale walls and RCC slab including beams etc with vent shaft, manhole opening with cover connections etc, complete with effective depth 1.5 meter and overall depth 3 mtr for 100 users (conventional).
Const. of onsite LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation ,vent shaft, connection etc complete for 25 users conventional.
Const. of onsite LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation ,vent shaft, connection etc complete for 10 users conventional.
Construction of Soakage well excavation, in any type of soil, foundation, in PCC 1:3:6, walls of hony combed masoonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masoanry in CM, RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC /DWC complete filled with bricks bats of size 3.60m diax4.50m effective depth.
Construction of Soakage well excavation, in any type of soil, foundation, in PCC 1:3:6, walls of hony combed masoonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masoanry in CM, RCC cover slab in M- 25/SFRC cover, inter connecting pipes of RCC /DWC complete filled with bricks bats of size2.40m diax3.00m effective depth
Construction of Soakage well excavation, in any type of soil, foundation, in PCC 1:3:6, walls of hony combed masoonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M- 25/SFRC cover, inter connecting pipes of RCC /DWC complete filled with bricks bats of size 1.80 m diax3.00m effective depth
Design and Construction of PQC Rigid Pavement Road and hardstanding including necessary excavation, GSB, DLC, sand layer, HDPE polythene film, PQC(Pavement quality concrete) and using of polyster trangular/noncircularfibers complete including forming all type of joints shall be provided as per MORTH and IRC specifications including removal of surplus soil to out side of MOD land (Dumping yard for disposal of surplus soil shall be own arrangement of Contractor and nothing extra shall be paid on this account) complete all as specified. Note:- Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids as per tentive schedule made part of tender.
Construction of RCC Box type culvert of length 10.00 Mtr, width 2.00 Mtr and depth 1Mtr complete all as specified and as shown on drg CEAF/SUR/WD/ST-553-05/15 sheet No 1/1
SCHEDULE `A' PART - I(B) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.(Contractor should submit the Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids)
Design, supplying & fixing Lighting Protection of buildings here in before at srl No (1.01 to 1.04) complete all as specified and directed. Note: Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids.
NOTE: Schedule ‘A’ Part II to VIII under Ser No. 3.01 to 3.08 are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORKS"” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY"” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for "AREA DRAINAGE WORKS ” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERTS WORKS” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “ADDN/ ALTN WORKS ” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING” as listed in Schedule ‘A’ Part XI
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
ROOM AND OFFICE CUM REST ROOM
M&L for angular lamp holder PVC / Polycarbonate type with back plate suitable for bulb fitting incl 9 watt LED bulb complete all as specified and as directed.
S&F LED flood light fitting 36 Watt, 220 V AC with driver, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L for flame proof, zone I & II, Gas Group II Al II B, weather proof submain wiring with two runs using approved colour coding as per IS, zero hologen flame retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheathed flexible copper conductor cable 6.0 Sqmm (nominal area) single core 1100 volts and one run earth wire of 6.0 Sqmm in and including ERW stove enameled black rigid conduit of required size but not less than 25mm dia, flame proof conduit accessories such as tee, bend, elbow, junction box complete all as specified.
M&L for flame proof, zone I & II, Gas Group II A/ II B, weather proof submain wiring with two runs using approved colour coding as per IS, zero halogen flame retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts and one run earth wire of 4.0 Sqmm in and including ERW stove enameled black rigid conduit of required size but not less than 25mm dia flame proof conduit accessories such as tee, bend, elbow, junction box complete all as specified.
M&L flame proof, zone I & II, Gas Group II A/II B, weather proof point wiring for one light point controlled by one switch using approved colour coding as per IS with zero halogen flame retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 2.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled conduit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 2.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified.
M&L flame proof, zone I & 11, Gas Group II A/ II B, weather proof point wiring for one light point controlled by one switch using approved colour coding as per IS with zero halogen flame retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enameled conduit heavy duty ISi marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified.
M&L flame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero halogen flame retardant (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled conduit heavy duty ISi marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete.
S&F switch flame proof, zone I & II, Gas Group II A/ II B, weather proof rotary type with termination box in LM6 16A single pole 250 V complete all as specified and directed
Supply and fixing flame proof, zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 16A, 240 V, 2 pin and earth plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRI complete all as specified and directed.
Supply and fix Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. complete all as specified.
Supply & fix flame proof, zone I & II, Gas Group II A/ II B, weather proof DB TPN 415 volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for MCCB TPN 160 Amps -1 Nos (incoming) and MCB TPN 63 Amps -03 Nos (outgoing) complete all as specified.
Supply & fix flame proof, zone I & II, Gas Group II A/ II B, weather proof DB SPN 230 volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for MCB SPN 40 Amp- 01 No (Incoming) and MCB SP 6-10 Amp -06 Nos (Outgoing) complete all as specified.
Supply and fixing flame proof, zone I & II, Gas Group II N II B, weather proof asymmetrical beam integral LED flood light fitting, grey powder coated die-cast aluminium lamp housing, built in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass cover 120 watt necessary clamps. nuts and bolts complete connecting electrically using flexible flame proof end connectors complete all as specified.
Supply & fix flame proof, zone I & II, Gas Group IIA/II B, weather proof DB TPN 415 volts 4 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries wilh cable glands suitable for hazardous area and confinning to IS 2147/62 neoprene gasket degree of protection IP 65 suitable for MCB TPN 63 Amps -1 Nos (incoming) and MCB SPN 40 Amps -04 Nos (out going) Make: Shyam or Eqvt Flexpro/Sudhir etc complete.
Supply & fixing flame proof, zone I & II, Gas Group IIA/II B, weather proof asymmetrical beam integral LED flood light fitting, grey powder coated die-cast aluminium lamp housing, built in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass cover 120 watt necessary clamps, nuts and bolts complete connecting electrically using flexible flame proof and connectors complete.
AIR CONDITIONING
Supply and install hi wall split units Indoor/outdoor 2 Ton complete with cordless remote control unit and with In built air ioniser and Plasma filter for better Indoor air quality with minimum 3 star rating and EEH 3.2 of capacity Including mounting arrangements as shown complete all as specified.
Supply and fix Voltage stabilizer for automatic operation, single phase Naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of current capacity 4 KVA with time delay relay and by pass arrangement.
Supply and fix water cooler electric driven (single phase) having approx storage capacity of 80 Ltrs & cooling capacity 40 Ltr per hours complete all as specified.
Supply and fix desert cooler electric driven (single phase) having nominal air flow capacity of 4000 CuM per hour ( or nearest size( steel body Ltrs per hours complete all as specified.
STAND BY POWER SUPPLY
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set coupled with alternator AC to Give continuous output of 160 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine water cooled, mounted on common base frame complete within built fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacture's instructions, vibration damper pads, micro processed based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the undermentioned technical specifications complete in all respect and all as specified & directed.
(A) DIESEL ENGINE : 6 cylinders in line water cooled, turbo charged air to air cooled to deliver not less than 156 BHP at 1500 RPM under NTP conditions IS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for 12 hrs of continuous operation with the following accessories:- (a) Radiator with blower fan or heat exchanger with guard (b) Pipe coupling for engine cooling system piping (c) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (iii) By Pass (e) Fly wheel housing and fly wheel to suit (f) Engine bearing mechanism in fly wheel housing (g) Shut off coil with safeties for LLOP /HWT./ Over speed. (h) Dry type air cleaners and vacuum indicators. U) Residential silencers. (k) Stainless steel exhaust flexible bellows.
(I) Motor driven priming pump. (m) Electric starter. (n) Battery charging alternator. (o) Exhaust piping made out of STIC C class MS Pipe inclusive of all accessories and hardware , necessary support as per manufacturer's recommendations to sustain back pressure with rain cap (p) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe. (q) First fill of oil coolant and diesel during commission and 12 hours testing. (r) Interconnecting copper cabling of adequate capacity between batteries and controller. (s) Fuel pipe. (t) self starter 24 volts DC. (u) Governor as per OEM (v) Fuel injection pump. (w) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following. (x) Battery voltage and charging rate (ii) Water temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours run (vi) Balance of fuel. (x) Safety control (Trip and indication) (a) High water temperature (b) Low Lube oil pressure (c) Low and high speed trip
(y) Base frame sturdy fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alongwith AVM pads (aa) Battery set of 02 No , 12 Volt, 65 AH maintenance free battery with leads and terminals. (bb) Fuel Tank : Built in diesel storage capacity (8 Hr running) 290 Ltrs of size fuel tank factory made of HR/MS sheets with level indicator fuel inlet, fuel outlets air vent drain plug in let arrangement for diesel filling from exteriors of canopy (without opening its panel) etc complete all as specified and directed (B) ALTRERNATOR: 160 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ±1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, 1503046. (C) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) having size not less than 4000mm lengthX1150mm widthX1850 mm height for the above 160 KVA DG set to reduce noise level to 75 db (A), measured at 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-:
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set coupled with alternator AC to Give continuous output of 40 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine water cooled, mounted on common base frame complete within built fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacture's instructions, vibration damper pads, micro processed based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the undermentioned technical specifications complete in all respect and all as specified & directed.
(A) DIESEL ENGINE : 3 cylinders in line water cooled, turbo charged air to air cooled to deliver not less than 51 BHP at 1500 RPM under NTP conditions IS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for 12 hrs of continuous operation with the following accessories:- (a) Radiator with blower fan or heat exchanger with guard (b) Pipe coupling for engine cooling system piping (c) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (iii) By Pass (e) Fly wheel housing and fly wheel to suit (f) Engine bearing mechanism in fly wheel housing (g) Shut off coil with safeties for LLOP /HWT./ Over speed. (h) Dry type air cleaners and vacuum indicators . 0) Residential silencers. (k) Stainless steel exhaust flexible bellows. (I) Motor driven priming pump. (m) Electric starter. (n) Battery charging alternator.
(o) Exhaust piping made out of STIC C class MS Pipe inclusive of all accessories and hardware, necessary support as per manufacturer's recommendations to sustain back pressure with rain cap (p) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe. (q) First fill of oil coolant and diesel during commission and 12 hours testing. (r) Interconnecting copper cabling of adequate capacity between batteries and controler. (s) Fuel pipe. (t) self starter 24 volts DC. (u)Governor as per OEM (v) Fuel injection pump. (w) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following. (x) Battery voltage and charging rate (ii) Water temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours run (vi) Balance offuel. (x) Safety control (Trip and indication) (a) High water temperature (b) Low Lube oil pressure (c) Low and high speed trip (y) Base frame sturdy fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alongwith AVM pads (aa) Battery set of 01 No , 12 Volt, 90 AH maintenance free battery with leads and terminals.(bb) Fuel Tank : Built in diesel storage capacity (8 Hr running) 70 Ltrs of size fuel tank factory made of HR/MS sheets with level indicator fuel inlet, fuel outlets air vent drain plug in let arrangement for diesel filling from exteriors of canopy (without opening its panel) etc complete all as specified and directed
(B) ALTRERNATOR: 40KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ±1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BSS000, IEC 34/1, ISO 8528, BS5514, 1503046, (C) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) having size not less than 2400mm lengthX950mm widthX1400 mm height for the above 40 KVA DG set to reduce noise level to 75 db (A), measured at 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-• (i) Sound proof insulation 100mm thick Rock wool (Density 65 KG / Cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA (iv) Inner surface: 1.0 mm thick powder coated & perforated CRCA / GI sheet (v) Common base frame: ISMC 250 (D) CONTORL PANEL : LT panel made out of 2mm thick CRCA sheets in suitable compartments front openable duly powder coated for a weather proof and long lasting finishing including the followings :-
EXTERNAL WATER SUPPLY
Supplying, laying , jointing and testing Ductile iron pipe S/S special class “K-9”, 100mm bore conforming to IS 8329 : 2000 including push on rubber tyton joints laid in trenches, in floor/under road, on wall complete all as specified and directed. Notes:- (i) The cost of jointing is deemed to be included in unit rate quoted. (ii) Earth work and fittings to be measured and paid separately, (iii) Pre-dispatch inspection of pipes shall be carried out by rep of Accepting Officer and arrangements for testing at factory premises shall be made by the contractor without any extra cost. (iv) All pipes shall be ISI marked. (v) Pipe fittings shall be of same makes as of pipe or as recommended by manufacturer of pipe.
All as per serial Item No 6.01 here in before but 150mm bore pipe
All as per serial Item No 6.01 here in before but 200mm bore pipe
Boring of holes under road, pavement, hard standing, by treanch less technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
Material and labour for constructoin of brick masonry valve pit of suitable size 100cmx100cmx105cm (internal dimension) with frame of angle iron work of size 40x40x6mm and MS sheet cover 3mm thick and locking arrangments and handle duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, including all excavaiton and connected work alongwith dismantling work of old valve pit system and removal of retireved unserviceable material outside MoD land, complete all as specified and directed.
All as per above Srl item No.6.05 here-in-brefore but 600mmx600mmx600mm
EXTERNAL ELECTRIC SUPPLY
Supply, install and testing of 11kV Outdoor Package Sub-Station shall be Each consisting of following, (A) HT load break switch:- 11 KV rated frequency 50 HZs, rated current cable switch disconnetor and bus bar 630 Amps non extensible outdoor manual CB type complete with metal enclosure switchgear conform to IEC 62271-200, circuit breaker (IEC 62271- 100) degree of protection of enclosure shall be IP -54, thickness stainless steel tank of 2.5mm with following switch gear (i) lncomer-01 No:- Cable switch modular with a three position load break switch and earthing switch, busbar, interlocking and earth bar complete with the following (a) Cable switch 11 KV, 630 Amp -01 (b) Manometer-01 (c) Snap action mechanism for manual operation-01 (d) Cable cover standerd with interlocking-01 (e) Cable bushing interface C (400 bolted), 63Amp Standerd-01 (f) Capacity voltage indication fixed type VPIS 9-15KV-01 (g) Cable support bars, standerd formal unit-01
(ii) Outgoing-01 No:- Cable switch modular with a three position load break switch and earthing switch, busbar, interlocking and earth bar complete with the following (a) Cable switch 11 KV, 630 Amp -01 (b) Snap action mechanism for manual operation-01 (c) Cable cover standerd with interlocking-01 (d) Cable bushing interface C (400 bolted), 63Amp Standerd-01 (e) Capacity voltage indication fixed type VPIS 9-15KV-01 (f) Cable support bars, standerd formal unit-01 (B) TRANSFORMER 160KVA 11KV/415V Dyn - 11 Dry type cast resin transformer with corrugated wall without conservator type of design & cable end box with Off load tap switch of range +5% to -5% in step of 2.5%. Temp Rise -Winding 45 Deg eel. Losses as per IS 11170:1985 Max losses at 50% load 1.29KW and 100% load 3.3KW and Impedance of 4.5%. (C) LT PANEL 250 AMPS Aluminum Busbar (100% FOR PHASES AND 50% FOR NEUTRAL) - LT panel shall be made up of 2mm thick CRCA sheet INCOMING 200 Amps 415V 4P 50Hz 25kA Fixed Manual Type (MCCB) with Microprocessor based release for Overload , Short circuit and earth Fault protection-01 Nos OUTGOINGS 100 Amps 415V 4P 50Hz 25kA Fixed Manual Type (MCCB) with Microprocessor based release for Overload , Short circuit and earth Fault protection -02 Nos
(E) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Non-load Bearing & load bearing partition sheets & Door with 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. As per IEC 62271-202 & K10 Class.
Supply and laying synthetic rubber insulated mats 2M x 1M x 10mm thick for voltage up to 3.3 KV for electrical putpose as per IS 15852-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2M x 1M complete all as specified and as directed.
Supplying, installation, testing and commissioning of 11 KV 630A Amps, HT vacuum circuit breaker indoor panel for outgoing conforming to IEC 62271- 200,25 KA for 1 sec, LSC2B-PM class front accessed comprising of indoor Vacuum Circuit Breaker all as specified and directed. Enclosed panel shall consists of following:- (a) 630 A continuous ratd electrolytic copper busbar, droppers and bus bars should be insulated with full system voltage sleeves (b) Trolly mounted horizontal racking in rack out and horizontal isolation, vacuum circuit breaker as per IEC 62271-100 so that the breaker rack in/out is done in a smooth manner. Vacuum circuit breaker should have vacuum bottles of the same manufactures as of circuit breaker. The vacuum bottle should be type tested for 100 full short circuit operations. (c) Motorized spring charging mechanism with integral spring charging handle for manual spring charge. (d) Panel separation with every department like VCB, Metering, Cable Chamber & Busbar Chamber
(e) Cast resin Current Transformer 11 KV 600-300/1+1A, core 1: class 0.5, 15VA, Core 2: 5P10, 15VA with metering and protection core including necessary control wiring & Potential Transformer 11 KV, Core I : CL 3P, Core II : CL 0.5 VA Burden : 50 VA OVF 1.9 for 30Sec. for metering & protection backed by HT & LT MCB's (f) Accessories like local remote switch, breaker control switch (T-N-C), space heater with thermostat, DC supply healthy, breaker ON/OFF, breaker in SERVICE/TEST. (g) Multifunction meter with port (EM64020ng). Including to extend the existing busbar from existing VCB to proposed outgoing VCB with all necessary connection complete.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½/ 4 core XLPE, armoured, Al conductor cable of size 25 to 50 Sqmm sqmm,lndoor/Outdoor type
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½/ 4 core XLPE, armoured, Al conductor cable of size 70 to 95 Sqmm sqmm,lndoor/Outdoor type
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with hghpressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix timer switches 415 V three Phase of 6.WV digital 24 Hrs type with contactor fitted inside steel enclosure complete with all connecting accessories all as specified and directed by Engineer in charge complete.
Supply and fix in replacement, CPRI approved, outdoor type, factory made cable Junction box of size 300mmx200mmx150mm dust, weather & vermin point proof, IP-65 protection, fabricated out of 3.15mm thick MS CRCA sheet with aluminium bus bar strip 25mmx3mm 3 phase and neutral and MCB 6Amps, 10KA, ‘C’curve, MS strip of size 25mmx4mm, made to shape, epoxy powder coated with anti corrosive paint and MS clamps, bolts, nuts, thimbles etc. for fixing arrangement for each street light including cable gland & locking arrangement, complete all as specified and directed.
M&L chemical earthing complete with copper eartl1 plate electrode 600 mm x 600 mm x 3. 1-S mm thick buried directly in ground vertically in a pit of depth not less than 3.15 metre below normal ground level with top edge of the earth plate at a depth not less than 2.90 metr,e below normal ground level, earth plate connected to copper strip 20 x 315 mm as earthing lead by means of running gas welding/ brazing for a length of 45cm, copper strip protected by galvanized steel pipe 50 mm bore medium grade upto ground level and there after by 50 mm dia HOPE pipe upto test point (maximum upto 7.Smetre from earth plate), including test point terminal block made of gun metal or phosphorns bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm land hex. head screw, and extra length of main earthing lead beyond 7.5 mtr earth plate surrounded by charcoal or coke and common salt upto 90 cm in alternate layers of 15cm each,
thereover a layer of 60cm tibba sand duly compacted,'thereafter 30 layer of magnesium sulphate powder (compacted thickness) and finally filing the top of pit upto ground level with tibba sand, to achieve earth resistance value less than 2 Ohm including provision of 20mm bore galvanised steel ,pipe .20mm bore light grade with funnel & wire mesh for watering, earth pit chamber built in cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate covered with 50mm thick pre-cast cover slab of RCC 1:2:4 type B-1 duly reinforced with 8mm dia MS TMT bars @ 15cm c/c both ways, wilh suitable handle made of 10mm dia MS round bar, including excavation & earthwork in any type of soil/ strata, removal of surplus .soil to a distance not exceeding 50 metre as shown in Eiectrical..Plate No. 3 of MES Schedule Part-I complete all as specified and directed complete all as specified and directed.
FLAMEPROOF EOT CRANE
Supply, Installation, testing & commissioning of Electric operated crane flame proof complete with span 8 to 9 mtrs of working capacity 10 Ton, 6 mtrs lift complete all as specified and as directed including following specifications:- (a) Capacity (Safe Working Load): 10 Ton (b) Span: 8-9 Mtrs. (Approx) (c) Lift 6 Mtrs: (Approx) (Flame Proof) {d) Type: Double Girder (e) Speed (Hoisting): 3 MPM (f) Speed (Cross Travel) : 8MPM (g) Speed (Long Travel): 12 MPM (h) Motors : Sq cage crane duty (S4) motor as per IS:325 (i) Motor HP : (Hoisting) 10HP x 1 No. 0) Motor HP (CT) : 2HP x 1 No. (k) Motor HP (LT) : 2 HPx 2 Nos. (I) Class & Duty : M6, Medium (m) Design Standard: As per IS:87,,IS:3177,2148 (n) Wire Rope: 16mm x 4 fall, 6x36 const, FMC Usha Martin, Mahadev or equivalent make (o) Operation : Through hanging pendent push button (p) Control Voltage: 110/24 V
(q) Supply Voltage : 400/440 V, 50 Hz, AC (r) Material of Wheel: Forget Steel (s) Type of hoisting brake: Electro, Hydrolytic, Thruster (t) Type of coupling : MS Fabricated or casted (u) Type of Bearings: Antifriction Ball/Roller Bearings (v) Type of Gear box: Totally enclosed splash lubricated (w) Type of Hook : Shank type made of forged steel, supported on thrust bearing (x) Bridge girder: Standard joist with inverted channel/Box type fabricated from plate, max, deflection of main girder limited to 1/900th span of live loads including the weight of the hoist. (y) Cross Conductor: Festoon type trailing cable with festoon trolley & track. (z) L.T Mechanism: Double Motor (Twin) drive (aa) L.T. DSL: Bus Bar Type
Supply, Installation, testing & commissioning of Electric operated crane flame proof complete with span 14 to 15 mtrs of working capacity 10 Ton, 6 mtrs lift complete all as specified and as directed including following specifications:- (a) Capacity (Safe Working Load): 10 Ton (b) Span: 14-15 Mtrs. (Approx) (c) Lift 6 Mtrs: (Approx). (Flame Proof) (d) Type: Double Girder (e) Speed (Hoisting) : 3 MPM (f) Speed (Cross Travel) : 8MPM (g) Speed (Long Travel) : 12 MPM (h) Motors: Sq cage crane duty (S4) motor as per IS:325 (i) Motor HP : (Hoisting) 10HP x 1 No. 0) Motor HP (CT) : 2HP x 1 No. (k) Motor HP (LT) : 2 HPx 2 Nos. (I) Class & Duty : M6, Medium (m) Design Standard: As per IS:87,IS:3177,2148 (n) Wire Rope: 16mm x 4 fall, 6x36 canst,
(o) Operation : Through hanging pendent push button (p) Control Voltage: 110/24 V (q) Supply Voltage: 400/440 V, 50 Hz, AC(r) Material of Wheel : Forget Steel (s) Type of hoisting brake: Electro, Hydrolytic, Thruster (t) Type of coupling : M S Fabricated or casted (u) Type of Bearings: Antifriction Ball/Roller Bearings (v) Type of Gear box: Totally enclosed splash lubricated (w) Type of Hook : Shank type made of forged steel, supported on thrust bearing (x) Bridge girder: Standard joist with inverted channel/Box type fabricated from plate, max, deflection of main girder limited to 11900th span of live loads including the weight of the hoist. (y) Cross Conductor: Festoon type trailing cable with festoon trolley & track. (z) LT Mechanism: Double Motor (Twin) drive (aa) L T. DSL: Bus Bar Type
Supply and fixing flame proof, zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 enclosure complete with 40 Amps 4 pole and earth appropriate MCCB of all as specified and directed
DEMOLITION AND RELAYING OF PQC FLOOR SLABS FOR GUIDE RAILS OF BP S-9 AND S-10
M&L for 300mm thick (spread thickness) Moorum filling in floors or pavings, ( for berms of rosds ) laid in layers n. exc. 15 cm thick, spread, watered rolled and consolidated to required gradient and camber using earth compactor of minimum 8 to 15 tonns capacity complete all as specified and as directed.
S&F Fire symbol board of size 1200mm x 1650mm made out of MS Sheet 1,60mm thick with frame made out of angle iron 50mmx 50mm x 6mm frame embeded in PCC block (1:2:4) type B-1 of size 50mmx450mmx500mm complete symbol board painted with two coats of synthetic enamel paint over a coat of red oxide primer including writing of letters as directed complete all as specified and directed.
DEMOLITION/DISMANTLING/TAKING DOWN
Disconnecting old u/s main switch, DB SPN/TPN, etc including MCBs from the existing position and removing to store for keeping in safe custody for taking credit complete.
Taking down ceiling/Exhasut fan sealing cable end dismantling blades and removing fan and blades handover to EM store for reuse complete.
Taking out submain wiring any type from site and revmoving materials to store for keeping in safe custody for taking credit complete.
Taking down regulator, sealing cable ends and removing regulator for credit complete.
Taking out old unserviceable GI earthing complete from the existing position including excavation and removing materials to store for keeping in safe custody for taking credit complete.
Taking down steel windows of any description and in any position area not exc. 4.00 sqm each incl. making good the disturbed portion complete all as specified and directed.
All as per Serial Item No 10.07 here in before but 40 to 50mm bore pipe
All as per Serial Item No 10.07 here in before but 25 to 32mm bore pipe
ADDN/ALTN ANNEX OF HANGER-2
Aluminium anodised grills of type DG 117 of make Deco-Grill, fixed to Aluminium anodised grills of type DG 117 of make Deco-Grill, fixed to window opAluminium anodised grills of type DG 117 of make Deco-Grill, fixed to window opening as in repairs complete all as specified and directed.ening as in repairs complete all as specified and directed. opening as in repairs complete all as specified and directed.
S & F in repairs for Plate Rack Stainless steel 600 x 750 x 250 mm thickness of sheet 1 mm complete all as specified and directed.
Factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07
Factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07
Mild steel PVC powder coated (coloured) curtain rod with fixing side brackets, end cups, rings@ 10 Nos per running metre and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
Factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD- 06/07 & CEJZ/TD-07/07.
M&L for Mild steel PVC powder coated (coloured) curtain rod with fixing side brackets, end cups, rings@ 10 Nos per running metre and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
S&F 200 mm dia 80mm thick cast iron steel wheel with 15x15 mm flange wheel pinned with 25mm dia to a 25mm thick plate in dia (wheel and connected to wheel complete all as specified.
S&F 100 mm dia roller 50mm thick solid steel having a hole in center to insert a bolt of 25mm dia complete all as specified.
S&F 3mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred, etc as required complete all as specified and as directed.
ROAD/PATH//CULVERT
Demolition of bituminous premixed carpet of any thickness incl. WBM and soling of stone boulders/crushed/broken stone ballast etc or bricks (old size bricks) in existing roads complete all as specified and as directed.
Supply and fixing , solar delineators. with ultra bright flashing LEDs, polycarbonate and toughened aluminum alloy body fitted on MS pipe 50mm dia (approximate 1.00m long ) powder coated anti rust, fixed in position in PCC 1:2:4 block 20x20x30cm with necessary fixing arrangement as per manufacture instructions complete all as specified and as directed.
Supply and fixing road stud high density reflective lense( two ways), plastic body, yellow colour, size 100mm x 100mmx 26mm,fixed in position with nails and adhesive as per manufacturer's instructions complete all as specified and as directed.
M & L painting 2mm thick of thermoplast fluorescent paint colour white or golden yellow or any other shade confirming to BS standard 3262 with 20% glass beads (inter mixed) applied hot with automatic (commercial) machine drive in strips after specifications laid down by IRC MOST (Ministary of Surface Transport) specifications 2001 (4th revesion), making lines, broken lines/dashes, arrows etc, on road and other like surfaces exceeding 10 cm but not exceeding 20cm in width or girth, complete all as specified and as directed.
Removing demolished Road materials etc retrieved from item above (other than soils) to a distance of exceeding 15.00 KM from the starting point (outside defense land) and depositing where suitable permitted disposal point available (Rates are inclusive of to find permitted suitable disposal point) incl. cleaning and leveling of demolition area/road formation and surroundings etc complete as directed.
VRC Constructions India Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid