Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹50.5 L+₹4.6 L (10.0%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹56.4 L+₹10.5 L (22.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | M/s Ajayshwar Singh Rana L1 | KISHOR KALAMKAR L3 | Sachdeva Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC | 7 | Qtl | 200 ₹1,400 | 100 ₹700 Lowest | 200 ₹1,400 |
| 2.00 | Taking out of unserviceable insulator any type complete all as specified | 240 | Each | 2 ₹480 Lowest | 20 ₹4,800 | 10 ₹2,400 |
| 3.00 | Dismantling and taking out old damaged ACSR or AAC conductor complete all as directed | 9.6 | Qtl | 300 ₹2,880 | 150 ₹1,440 Lowest | 200 ₹1,920 |
| 4.00 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed . | 862.7 | Cum | 190 ₹1,63,913 | 200 ₹1,72,540 | 180 ₹1,55,286 Lowest |
| 5.00 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed . | 496.16 | Cum | 145 ₹71,943.2 | 50 ₹24,808 | 40 ₹19,846.4 Lowest |
| 6.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed . | 362.54 | Cum | 100 ₹36,254 | 50 ₹18,127 | 40 ₹14,501.6 Lowest |
| 7.00 | Material and labour for GI pipe of Size 80 mm bore light grade under floor, under road cutting and as protection of cable complete all as specified and directed. | 24 | RM | 550 ₹13,200 Lowest | 800 ₹19,200 | 750 ₹18,000 |
| 8.00 | Material and labour for GI pipe of Size 50 mm bore light grade funder floor, under road cutting and as protection of cable complete all as specified and directed. | 30 | RM | 495 ₹14,850 | 550 ₹16,500 | 450 ₹13,500 Lowest |
| 9.00 | Material and labour for GI pipe of Size 40 mm bore light grade under floor, under road cutting and as protection of cable complete all as specified and directed. | 80 | RM | 440 ₹35,200 | 400 ₹32,000 | 350 ₹28,000 Lowest |
| 10.00 | Material and labour for clean dry and sharp sand as in cushioning layer over and under cable laid in trenches complete all as specified and directed.
Note: Punned thickness shall be measured and paid. | 307.5 | CUM | 600 ₹1,84,500 Lowest | 800 ₹2,46,000 | 650 ₹1,99,875 |
Tender Value
₹47.0 L
EMD Value
₹93,900
Closing Date
1 Apr 2026, 6:00 pmClosed
GE (E) JABALPUR
GE (E) JABALPUR-482011
SPL REPAIR/ REPLACEMENT AND CONVERSION OF LT OH LINE INTO LT UG CABLE ATA AREA, AIRAWAT GATE, CHURCH LINE OFFRS AREA AND ALLIED WORKS AT MCMM AND PROVISION OF ELECTRIC INCINERATOR FOR DISPOSAL OF WASTE PAPERS AT MCMM UNDER GE (EAST) JABALPUR
2026_MES_755848_1
8835/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (EAST) JABALPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (EAST) JABALPUR
₹93,900
Yes
10 Jun 2026
11 Mar 2026
6 Apr 2026
11 Mar 2026
1 Apr 2026
25 Mar 2026
Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC
Taking out of unserviceable insulator any type complete all as specified
Dismantling and taking out old damaged ACSR or AAC conductor complete all as directed
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed .
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed .
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed .
Material and labour for GI pipe of Size 80 mm bore light grade under floor, under road cutting and as protection of cable complete all as specified and directed.
Material and labour for GI pipe of Size 50 mm bore light grade funder floor, under road cutting and as protection of cable complete all as specified and directed.
Material and labour for GI pipe of Size 40 mm bore light grade under floor, under road cutting and as protection of cable complete all as specified and directed.
Material and labour for clean dry and sharp sand as in cushioning layer over and under cable laid in trenches complete all as specified and directed. Note: Punned thickness shall be measured and paid.
Supply & laying dry bricks over cable as mechanical protection layered flat with width equal to length of brick with sub class 'B' bricks complete all as specified and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 2 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 sqmm 2 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 sqmm 4 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 sqmm 4 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 sqmm 4 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 70 sqmm 3.5 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95 sqmm 3.5 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 120 sqmm 3.5 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 185 sqmm 3.5 core all as specifed and directed.
Material & labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 240 sqmm 3.5 core all as specifed and directed.
Material and labour for Bus bar chamber of Size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 250 Amp 430 V 4 pole , 36 KA MCCB as incommer control and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase with neutral, 415 volts 50 Hz AC supply including control wiring to panel with suitable Size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set complete all as specified and directed.
Material and labour for Bus bar chamber of Size 700 x 550 x 480 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 250 Amp 430 V 4 pole , 36 KA MCCB as incommer control and including 300 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase with neutral, 415 volts, 50 Hz AC supply including control wiring to panel with suitable Size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set complete all as specified and directed.
Supply, installation, testing & commissioning totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed and 500 Amp rated bus bar TPN complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- . Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI and width of the panel should not be less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (20 mm thick stone aggerate), deemed to be included in the item rate. No extra payment will be made on this account. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing)
(b) OUTGOING (i) MCCB 415 volts grade 200 Amps rating and 16 KA rupturing capacity -02Nos (ii) MCCB 415 volts grade 250 Amps rating and 36 KA rupturing capacity -02Nos (iii) MCCB 415 volts grade 100 Amps rating and 16 KA rupturing capacity -01Nos
Supply, Installing & testing and commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated made out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed and 500 Amp rated bus bar TPN complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- . Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI and width of the panel should not be less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (20 mm thick stone aggerate), deemed to be included in the item rate. No extra payment will be made on this account. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing)
(b) OUTGOING (i) MCCB 415 volts grade 200 Amps rating and 16 KA rupturing capacity -02Nos (ii) MCCB 415 volts grade 100 Amps rating and 36 KA rupturing capacity -02Nos
Supply and fixing thermoplastic polystyrene/ polycarbonate enclosure shock proof, IP 65 (weather proof) rust proof, dust proof, water proof, internally embeded gasket with provision for all side cable entry through gland(IP-65) and /or gromments (IP-55) size of enclosure (250x 200 x 105mm ) with suitable connectors for / 3 phse loop in loop out and branch out vibration proof connections and fixing on PCC / Steel poles with 25 x 3 mm thick 02 Nos of clamp with nuts bolts and washers and proper thimbling complete all as specified and directed.
Supply & fixing of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take three-phase load of 12KW;contactor Rating 25Amps; MCB(SPN) Rating 32 Amps complete all as specified and directed. MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/Bajaj/healer or equivalent. Model no SWADEEP-02EC12KW3P.
Supply & fixing of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 25 Amps; MCB(SP) Rating 32 Amps complete all as specified and directed. MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer or equivalent. Model no SWADEEP-02EC5KW1P.
Supply and fixing multi core round PVC insulated aluminium conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core from junction box /overhead conductor to street light inside/outside pole complete all as specified.
M & L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth strip 25 x 4 mm GI Strip by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and galvanised steel tubing as per suitable size and suitable dia for protection of GI Strip upto 7.5 m length fo drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed. Note: Cost of GI strip and protection pipe upto 7.5m is deemed to be included in quoted rate.
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling stay assembly complete including cement concrete complete all as specified and directed.
Supply, install, testing and commissioning of Electric incinerator having 30 Kg/Hr burning capacity horizontal/vertical type comprising of primary chamber, secondary chamber, Job designed on "controlled air" incineration principle and provided with minimum of 115mm thick refractory and insulation bricks to sustain minimum temperature of 900 Degree centigrade in the primary chamber and 1100 Degree centrigrade in secondary chamber, chamber made of mild steel plate of adequate thickness (minimum 6 mm thick), 5 metre high chimney, PLC based control panel, Cyclone separator etc., including all other accessories and piping, equipments for installation of incinerator chimney complete all as specified, including- 1.Inter connection piping, ID fan, FD fan, instruments, 2.Electrical control Panel with all electrical power, earth and control cable complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable covers, Class HVP type-1 with peak, size 250 mm x 150 mm x 40 mm, complete all as specified and as directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and directed
M&L cement concrete (1:4:8) type D-2 (40 mm graded stone aggregate) as in mass concrete complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in mass concerete and founding filling complete all as specified and directed.
M&L old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed
M&L 10 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F MS steel flat iron as in wind tie for roof sheet including securing bolts complete all as specified and directed.
M&L preparing new steel surfaces and applying two coat of syntheitc enameled paint over a red oxide primer exc 10 cm width or grith complete all as specified and directed.
M&L for prepraring newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed.
M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thcik PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base complete all as specified and directed.
M&L for PCC 100 mm thick 1:2:4 type B2 as in floor finished the surface even and fair complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Schedule of credit amount of Rs. 54,148.00 to be deducted during AOC.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDER8835.pdf
Tender Documents • 1.14 MB
BOQ_846618.xls
BOQ • 1.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .