Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.5 LAccepted-AOC | ₹21.5 L Quoted ₹24.0 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹33.1 L+₹9.0 L (37.6%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | ₹33.1 L+₹9.0 L (37.6%) | L-2 | Rejected-Finance L-2 |
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
22 Mar 2023, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
SPECIAL REPAIR TO LT OH TRANSMISSION LINE LIGHTNING CONDUCTOR UG CABLE ALONGWITH CONNECTED ACCESSORIES AND 12 x GEYSERS AT KHUNDRU UNDER GE 861 EWS
2023_MES_581227_1
GE 861 EWS-73/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹68,800
Yes
1 Apr 2023
15 Feb 2023
29 Mar 2023
15 Feb 2023
22 Mar 2023
3 Mar 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation of poles/stay etc including getting out in any type of soil complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in foundation filling and mass concrete (rounded or chamfered on edges), complete all as specified.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in foundation filling and mass concrete (rounded or chamfered on edges), complete all as specified.
Dismantling of ACSR or AAC conductors, complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m, complete all as specified and directed.
Dismantling insulators any type, any size, complete all as specified and directed.
Steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-31 ( 9 Mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified laying GI pipe light grade for cable protection and fixing to existing pole with flat iron clamp 25x3mm including nuts bolts and washers etc complete of 40mm dia including taking out old unserviceable pole, complete all as specified and directed.
Pin type insulator porcelain, vitreous, white/ brown or green insulators including one galvanized MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade, complete all as specified and directed.
Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia, size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade, complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv, complete all as specified and directed.
Aluminium conductors steel reinforced (ACSR) of any size for OH lines including stretching, binding wire, jumpers, line taps etc incl dismantling of old unsv, complete all as specified and directed.
Supply & fixing in repair of stay assembly complete with accessories as shown in electric plate No. 1 and including loop type insulator white brown or green with over all dimensions 65x90mm, clearance of hole 16mm, complete all as specified and directed.
Supply and fixing in replacement 1.50 sqmm three core PVC insulated flexible copper conductor cable to cut pieces all as required drawn into conduit/pipe fixed to wall or pole, complete all as specified and directed.
Continuous earth wire/guard cradle hexagonal/rectangular fabricated with 4mm dia galvanized mild steel, binding wire incl dismantling of old unsv complete all as specified and directed.
S & F in repairs security light brackets with 1.50mtrs long 40mm dia medium grade galvanised iron pipe with 30° bend including flat iron clamps, nuts, bolts and washers to brace the same properly duly painted with two coats of silver coloured synthetic enamel paint over one coat of red oxide primer and making the good to disturbed surfaces to match with existing, complete all as specified and directed.
LED street light fitting 45 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic geart housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessaries and taking down old existing unsv, complete all as specified and directed.
Replacement of outdoor type SMC junction box of size 170x170x105mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with suitable fixing arrangement bus bar with single electrolytic aluminium for both phase and neutral supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and outlet , provision for cable connection, MCB SP 6 Amps rating 'B' curve for controling the pole light including necessary connection, complete as specified and directed .
Supply and laying in repairs 50mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip or crossing of nallaj/bridge/road etc., complete all as specified and directed.
Supply and laying in repairs 40mm dia GI tubing light grade with all fitting laid in trenches or pavement or fixed on wall or along pole complete for protection of GI strip or crossing of nallaj/bridge/road etc., complete all as specified and directed.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 50 sqmm nominal cross section 3.50 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note: (i) Earth work and protection work shall be measured and paid for separately under respective items of BOQ. (ii) The cost of thimbles/lugs and cable gland etc. are included in quoated rate and nothing extra will be paid.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 sqmm nominal cross section 3.50 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note: (i) Earth work and protection work shall be measured and paid for separately under respective items of BOQ. (ii) The cost of thimbles/lugs and cable gland etc. are included in quoated rate and nothing extra will be paid.
S & F in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip, complete all as specified and directed.
Supply & fixing in replacement air termination, single pointed copper rod 12mm dia and 300mm long, including fixing of GI base on epoxy insulators of suitable size to isolate from the roof and fixing of insulators on roof over the purlin using self tapping screws of suitable length or other means to make the roof leakage proof for fixing of air terminal rod and connecting with down/roof conductors, complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 2.50 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.50 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked, complete all as required at site or directed.
Supply & fixing in repair aluminium strip 25x3mm, incuding epoxy/procelain insulators of suitable size, distance between insulators not more than1mtr including fixing screws, washers etc. complete for PCC block of size 200x200x200mm for RCC roof using screws, washers, gutti/rawal plugs etc., complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze, size 75x75x25mm drilled and screw end connected to Aluminium/GI strips including 3 Nos, 8mm dia, 25mm long hexagonal head screw and fixing of test point with sheet metal enclosure on insulators to isolate from the walls, fixing of insulator on walls using suitable size of screws, washers, gutti/rawal plugs etc. including taking down of old damaged test point terminal block & making good to disturbed surfaces, complete all as specified and directed.
50mm bore HDPE non pressure pipe, smooth wall, non-metallic flexible, suitable for underground/wall earthing strip use, pressure rating not less than PN-2.5, minimum wall thickness 2.5mm for protection of GI strip/conductor passing through the wall and from test point upto plinth protection including PVC saddle/clamp, nut bolts etc., complete all as specified and directed.
Supply and fixing LT Overhead lines on existing poles with XLPE Insulated AB Cable 3-Core x 50 Sqmm + 1 core x 35 Sqmm phase cores twisted around aluminium alloy insulated messenger conductor conforming to IS: 14255 including identification of phase by Ridges provided on the insulation of Phase conductors: 1 ridge for the 1st Phase, 2 Ridges for the 2nd Phase and 3 Ridges for the 3rd Phase and 4 Ridges for Neutral including accessories like Anchor Clamp, Suspension Clamp, Line Connector, service clamp, insulation piercing connectors, (IPC for Tap from Bare lines) Dead End, Suspension clamp, I Hook etc., complete all as specified and directed.
Supply & fix in repair Rigid non-metallic grade PVC conduit of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
LED flood light fitting 50 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with pressure die cast aluminum housing with high power LED flood light luminaires complete with IP66 protection including all accessaries and taking down old existing unsv, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 4.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4.0 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked, complete all as required at site or directed.
S & F in repair bus bar chamber of size 60x60x45cm suitable for 3 phase 433 volts, outdoor type made out of 3.15mm thick MS sheet with 200 Amps rated aluminium bus bar(4 Nos) PVC sleeves and coloured (red, yellow, blue and black) with locking arrangements and angle iron stand of size 40x40x6mm frame grouted in ground with PCC foundation 1:2:4 type B-1 with 20mm graded stone aggregate alongwith all necessary cable connections, lugs and cable gland including 2 coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Earthing complete with copper plate electrode of size 600mmx600mmx3.15mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using copper strip 20x3mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long copper strip of size 20x3mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9.00%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
MCB distribution board , 240 volts single pole and neutral , single door, sheet metal enclosure powder coated with 200 Amps rated copper busbar with neutral link, 2 ways, IK-09 & IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SPN, AC, 240 volts "C" series capacity of 20 Amps, 10kA and making connections, complete all as specified and directed.
Earthing complete with galvanised cast iron earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 9%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M/s Gh Qadir and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .