| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.6 L+₹1.3 L (13.1%)Rejected-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹11.8 L+₹1.6 L (15.3%)Rejected-AOC D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹13.2 L+₹3.0 L (28.9%)Rejected-AOC | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹13.4 L+₹3.1 L (30.2%)Rejected-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-AOC Not Being L1 |
Tender Value
₹14.4 L
EMD Value
₹28,720
Closing Date
14 Oct 2019, 6:00 pmClosed
Lt Col Abhyudaya Pant
GE E/M RR Hospital Delhi Cantt-10
REPAIR MAINTENANCE OF VARIOUS TYPE OF PUMP MOTOR SETS LT ELECTRIC CONTROL PANELS INSTALLED WITH PUMP HOUSES INCLUDING ALLIED WORKS NEEDS FOR UPKEEP MAINTENANCE OF WATER SUPPLY AT AHRR UNDER GE EM RR HOSPITAL DELHI CANTT 10
2019_MES_278374_1
GE/H-16/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE E/M RR Hospital Delhi Cantt-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR Hospital Delhi Cantt
₹28,720
Yes
15 Jan 2020
14 Sept 2019
15 Oct 2019
14 Sept 2019
14 Oct 2019
28 Sept 2019
Amount
Dismantling of centrifugal pump set along with motor of capacity 30 HP after disconnecting all electrical connections and transporting to workshop for repair / over hauling cleaning ,of impellers strainers Rewinding of motor 30 HP of any make complete with equivalent gauge of copper winding wire, paper & sleeve, wooden stick, 'O' ring set & including l taking out from the base and refixing the same after repair / replacement complete all as specified . (Note :- Unserviceable parts to be replaced under this item shall be paid as supply only under respective item (i.e. Srl No. 2 to 9) here-in after. However taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Pump House No. 1 - 01 Nos (b) Pump House No. 2 - 01 Nos
Supply only ball bearing 6309
Supply only ball bearing 6312
Supply only CI gland for 30 Hp Pump
Supply only SS shaft sleeves in 30 HP pump with complete nut, bolt & stufs, nut & flanged, upper & lower, studs & nuts complete all as specified
Supply only key coupling for 30 Hp pump
Supply only bearing housing for 30 HP pump
Supply only lock washer for support foot for 30 HP pump
Supply only bearing cover DE suitable for 30 HP pump
Dismantling of centrifugal pump set along with motor of capacity 25 HP after disconnecting all electrical connections and transporting to workshop for repair over hauling cleaning of impellers strainers Rewinding of motor 25 HP of any make complete with equivalent gauge of copper winding wire, paper & sleeve, wooden stick, 'O' ring set & including replacement of incl taking out from the base and refixing the same after repair / replacement complete all as specified . (Note :- Unserviceable parts to be replaced under this item shall be paid as supply only under respective item (i.e. Srl No. 11 to 18) here-in after. Hovever taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Pump House No. 2 - 01 Nos
Supply only ball bearing 6307
Supply only ball bearing 6308
Supply only Shaft SS 410 for 25 HP
Supply only CI gland for 25 HP
Supply only inter stage ring 25 HP
Supply only Drive end Bearing housing CI
Supply only CI centre ring for 25 HP
Supply only Air release valve of size 20 mm for 25 HP
Dismantling of centrifugal pump set along with motor of capacity 100 HP after disconnecting all electrical connections and transporting to workshop for repair over hauling cleaning of impellers strainers Rewinding of motor 100 HP of any make complete with equivalent gauge of copper winding wire, paper & sleeve, wooden stick, 'O' ring set & including replacement of incl taking out from the base and refixing the same after repair / replacement complete all as specified (Note :- Unserviceable parts to be replaced under this item shall be paid as supply only under respective item (i.e. Srl No. 20 to 26) here-in after. However taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Pump House No. 1 - 01 Nos
Supply only CI centre ring for 100 HP
Supply only Cast iron shaft sleeves
Supply only Cast iron bearing housing box
Supply only CI Impeller with key, stud, MS bolts & nuts for 100 HP as per size requirement (1/2x2", 5/8x2.5") MS stud (19x65mm) complete all as specified and directed
Supply & Fixing tyre coupling for 100 HP code no TC /M - 17 complete all as specified
Supply only gun metal sleeves for 100 HP Pump set
S&F cooling fan for 100HP induction motor
M&L for transportation of monoblock pump set of capacity 10.0 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick 'O' ring complete ( other spares required for motor will be measuerd and paid under relevant item(i.e. under Srl No. 34 to 40 & 46) here-in-after as supply only all as specified and as directed . Location: (a) MT - 01 Nos (b) Pump House No. 1 - 01 Nos
M&L for transportation of monoblock pump set of capacity 7.5 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick 'O' ring complete all as specified and as directed. (Note :- Other unserviceable parts to be replaced under this item shall be paid as supply only under respective item (i.e. under Srl No. 30 to 33) here-in after. However taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) 'J' Block - 01 Nos
M&L for transportation of monoblock pump set of capacity 5.0 HP to local work shop and rewinding the motor with equivalent gauge of insulated copper winding wire & insulating materials i.e. PVC sleeves insulation papers wooden stick 'O' ring complete all as specified and as directed. (Note :- Other unserviceable parts to be replaced under this item shall be paid as supply only under respective item (i.e. under Srl No. 41 to 45) here-in after. Hovever taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Laundary - 02 Nos (b) Radiotheraphy - 01 Nos
Supply only in replacement of connection pieces suitable for 7.5 HP pump
Supply only in replacement of rotor guard for 7.5 HP
Supply only replacement of SS rotar sleeves for 7.5 HP
Supply only in replacement of sealing ring dor 7.5 HP
Supply only in replacement of connection pieces suitable for 10 HP pump
Supply only in replacement of CI upper & lower housing for 10 HP
Supply only in replacement of CI motor base for10 HP
Supply only in replacement of revolving disc for capacity10 HP
Supply only in replacement of rotor guard for 10 HP
Supply only in replacement of SS rotor sleeves for 10 HP
Supply only in replacement of sealing ring for 10 HP
Supply only in replacement of connection pieces suitable for 5.0 HP submersible pump
Supply only in replacement of CI upper & lower housing suitable for 5.0 HP
Supply only impeller gun metal for 5.0 HP
Supply only in replacement of rotor guard for suitable for 5.0 HP
Supply only in replacement of sealing ring for suitable for 5.0 HP
Supply only in replacement Drive end Double roller bearing of any number/Model suitable for 10 HP open well submersible pump.(Bearing make shall be of SKF/NBC)
S&F in repair fully reflective sign board made of 18mm gauge stainless steel sheet frame of size 1200 mm x900 mm sorrounded by 25mm stainless steel square pipe all around ,applying two coats of synthetic enemal paint ( blue colour) over a coat of red oxide including writing letters of height not exc 30 cm each (approx letters exc 30 and not exc 60 in numbers of any kind like block, Roman, Italic, Indian, Stop, Commas, Short line, dashes, hypens, brackets etc as directed by Engr-in Charge) with using retro reflective tape using HIP grade one, entire frame welded to post of 3.0 M long MS pipe of 50mm bore light grade( 2.60 Mtr above Ground level and 0.40Mtr below Ground level), embeded on ground with PCC 1:2:4 type B1 using 20mm grade stone Agg including necessary earth work of 30cm x30cmx40cm post holes complete all as specified and as directed by Engineer-in-charge.
Taking out defective submersible pump set 7.5 HP capacity and transporting to workshop for making the submersible pump set serviceable / repairs to motor / repairs to pump set including making necessary connection to the Electrical control pannel all as specified and as directed Shifting to local work shop and Rewinding of submersible motor after cutting the burnt winding including cleaning slots and rewinding with equivilent gauge (as retrieved) of insulated copper winding wire and insulating material I.e PVC sleeves insulation paper , wooden sticks, 'O' ring for 7.5 HP complete all as specified and as directed by Engineer-in-charge. (Note :- Other unserviceable parts to be replaced under this item shall be paid as supply only under respective item her-in after. Hovever taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Radiotheraphy - 01 Nos (b) P-103 - 01 Nos (c) Near AC Plant - 01 Nos
Taking out defective submersible pump set 5 HP capacity and transporting to workshop for making the submersible pump set serviceable / repairs to motor / repairs to pump set including making necessary connection to the Electrical control pannel all as specified and as directed Shifting to local work shop and Rewinding of submersible motor after cutting the burnt winding including cleaning slots and rewinding with equivilent gauge (as retrieved) of insulated copper winding wire and insulating material I.e PVC sleeves insulation paper , wooden sticks, 'O' ring for 5.0 HP complete all as specified and as directed by Engineer-in-charge (Note :- Other unserviceable parts to be replaced under this item shall be paid as supply only under respective item her-in after. Hovever taking down old unserviceble part and fixing only of new part are also included the quoted rates.) Location: (a) Radiotheraphy - 01 Nos (b) P-18 (Near Fountain) - 02 Nos
Supply only pump shaft made of SS for 5 HP
Supply only neck ring for 5 HP
Supply only guide bush for 5 HP
Supply only bush for 5 HP
Supply only sleeve for 5 HP
Supply only CI piece for 5 HP
Supply only pump shaft made of SS for 7.5 HP
Supply only neck ring for 7.5 HP
Supply only guide bush for 7.5 HP
Supply only SS Distance sleeves for 7.5 HP
Supply only bush for 7.5 HP
Supply only sleeve for 7.5 HP
Supply only gun metal impeller with key for 7.5 HP
Supply only CI piece for 7.5 HP
S&F in repairs of DOL starter 3 phase 415 volt 5 HPRelay range 6 to 10 Amp, ( Make Crompton Greaves cat part No.CG1D130220 or equivalent in Legrand/Havells/L&T).
S&F in repairs of DOL starter 3 phease 415 volt 7.5 HP Relay range 20 to 32 Amp( Make Crompton Greaves cat part No.CS90947 or equivalent in Legrand/Havells/L&T).
Supply and fix in repairs amp meter digital type 0-100 amps . Make- AE/EE/NUTRONICS (DPS)
S&F in repairs indicating light with bulb set of three(Make- AE/EE/NUTRONICS (DPS)
S&F in repairs of 3 pole power contactors- type MNX ,conforming to IS P/IEC 60947-4-1 & IEC 60947-4-1, range from AC3 rating (A) 40AMPS cat part no. CS94190 Make- L&T or equivalent in Havells/Legrand.
S&F in repairs of Thermal overload relays type MN, Relay Range (A) 24-40(Make- L&T Havells/Legrand).
S&F in replacement of Electronic motor protection relay MPR200nX , inbuilt CT's (1 Ato 88 A) as per IEC 947-4-1 O/L Range (A) 32-88 Cat No. MPR205BE320 ,Make- L&T or equivalent in Havells/Legrand.
S&F in repairs of Fully- Automatic star-delta starters in Sheet -Sheet enclosure type MK,ML,MU & MB (moter rating AC-3 Duty ,415V,50 Hz,3Ph 15 Hp relay 11-18 Cat No SS96257, Make- L&T or equivalent in Havells/Legrand.
S&F in repairs of Submersible pump controller in sheet enclosure type max motor output at 230v-3-Ph Relay Max range 20-32 A Cat part No. CS96167, Make- L&T or equivalent in Havells/Legrand.
S&F in replacement of Supply monitoring devices type SM 501 (3Ph,3W), time deley On delay 5 sec and off delay 5 sec Cat part No.MG53BO, Make- L&Tor equivalent in Havells/Legrand.
S&F in repairs PVC flat sheathed submersible cable copper conductor of size 4.0 sqmm 3 core,1100 volt grade.( Make : L&T, Finolex,RR kable,Grandly, Polycab)
S&F in repair PVC flat sheathed submersible cable copper conductor of size 6.0 sqmm 3 core,1100 volt grade.( Make : L&T, Finolex,RR kable,Grandly, Polycab)
S&F in repairs of MCCB 125 amps 4 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified.
S&F in repairs AC megnatic contractor type CM-40 as per IS 2959/1985 complete all specified as per directed.Make- Schneider / L&T / Havells.
S&F in repairs switch disconnector 125 Amps AC 415 Volt with HRC fuse. Make-L&T/Sachinider/Legrand/ABB
S&F in repairs switch disconnector 160 Amps AC 415 Volt with HRC fuse. Make-L&T/Sachinider/Legrand/ABB.
S&F in repairs Fuse HRC 250 Amp 415 volt AC ,80 KA.
S&F in repairs Fuse HRC 160 Amp 415 volt AC ,80 KA .
S&F in repairs of MCCB 100 amps 4 pole 50 KA 415 volts 50 HZ in LT control panel complete all as specified .
S&F in repairs MCCB 3 pole 415 volt AC of capacity 63 amps 25 Ka cap.
S&F in repairs MCCB TP 415 volts 4 pole AC of capacity 63 amps .
S&F in repairs of MCCB 200 amps 3 pole 36 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed.
S&F in repairs of MCCB 125 amps 3 pole 35 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed.
Supply & fix in replacement of MCCB160 amps 3 pole 36 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed .
S&F in repairs of MCCB 250A 3 pole 50 KA 415 volts 50 HZ in LT control panel complete all as specified and as directed .
Dismantling of Blocked nozzles fixed on various fountain and refixing after cleaning / servicing and setting by trial and error complete all as specified and as directed.
S&F in repairs fountain nozzle (adjustable) of size 12mm brass complete all as directed.
S&F in repairs of fountain nozzle (adjustable) of size 15mm brass
S&F in repairs fountain light fitting 12 Volt DC emitting colour RGB with led 9 wattof stainless steel base.
M&L for preperation of old steel surface(i.e fountain assembly made of MS/GI/Steel pipe ) including complete removal of existing paint and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified.( The approx area for painting of each structure is approx 10 Sqm. It is just for guide line however the tendere are advised to visit the structure. No price adjustmment shall be admissible for variation in area as specified herein before.The quoted rate by the tendere are deemed to be included for the same)
M&L for scrubbing out the rust deposited on the surface of centrifugal pump set including its base frame and preparing for applying paint and apply one coat of redoxide primer and two coat of synthetic enamel paint and marking SM /MES Number as directed. capacity of pump set 15 to 30 HP
S&F in repairs on load change over swith 4 pole 400 amps 440 volts open Execution type complete all as specified.( Make Havels/L&T /Legrand)
M&L for development of bore well of 780 mm bore and up to 50 meters deep at the pressure not less than 6kgs/SqCm by using suitable air compressor and connected items to improve the yield of bore well complete all as specified and directed. NOTE: (I) Transportation of air compressor along with tools and accessories at different location for devolopment of bore well shall be the responsibility of contractor and the rate quoted will be deemed in the quoted rate). M&L for removing the blockage in bore well casing pipe at the depth not less then 50 meters from ground level by means of bocky or any means without damaging the casing (filter and blind pipe) upto the depth of bore. Location: (a) Near CTVS - 01 Nos (b) Tamanna Garden (A Block front area) - 01 Nos
Taking up of sumersible pump of 5 HP capacity from borewell at the depth of up to 50 mtr from below ground level and transporting to workshop for repair including MS flange having 12mm thick, slots cutting in flanges for passing of submersible cable including all jointing material such as bolts,nuts,washers&packing sheet and replacement of sumersible cable. Location: CTVS
S&F in replacement of sumersible cable of size 6 sqmm 4 core complete.( Make : L&T, Finolex,RR kable,Grandly, Polycab)
S&F in repairs well cap suitable for 50mm bore dia consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated from MS sheet 3.15 mm thick all as specified and directed.
S&F in repairs of MCB C-Curve type 10KA upto 6 to 32 Amp, SP complete all as specified and directed.
M&L for earthing with Galvanised Steel earth plate electrode of size 600 x 600 x 6mm thick directly burried in ground (earth pit not less then 4Mtr deep below ground level with tope edge of earth plate not less than 1.5 Mtr below the ground level connected by GI Earth Strip of Size 32x 6mm thick by means of Bolts, Nut,Check Nuts and Washer of GI or Steel GI Pipe 40mm Bore light grade for protection of earthing strip, PCC CHAMBER 1:4:8 TYPE D-1 using 20mm graded stone agg. Internal surfaces of chamber shall be plastered 12mm thick in CM 1:4 funnel with wire guage of 22 guage(0.63mm) 8 mesh per linear inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm grade stone agg. reinforced with 8mm dia TMT Bar @80mm C/C both ways and charcoal dust and common salt all as specified and shown in electrical plate No of 5 of SSR part-I including excavation of earth work, returning , filling, removing surplus soil not exc 50 m and connecting the earthing to an earthing test point as specified and testing on completion
M&L for opening / taking out of FIP ( fuel injector pump ) of diesel engine set of 75 kva capacity. . carrying complete overawling/servicing/reconditioning of pump ,with and including replacement of all UNSV parts as required,including testing complete and re-assembling the same , fitted with diesel engine set properly in original location, checking and making proper all connections , testing for smooth operation complete all as directed. Note: 1. The cost of replaced spares/parts is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. 2. The cost of transpotation ( to and fro) for all kind of necessary equipment/ T&P shall be arranged by contractor to complete the job. 3. The complete works is to be caried thought the authorise service center of manufacturer only. Location: Pump House No. 2
S&F in repairs,radiator cap , suitable for diesel engine set of any type / make and any type/ make /capacity complete all as directed.
S&F in repairs,Oil pressure pipe , suitable for diesel engine set of any type / make and any type/ make /capacity complete all as directed.
Supply and fixing , in replacement ,Fan belts, V-type No B128 suitable for colling tower of diesel engine set 1000 KVA complete all as directed.
Supply and fixing , in replacement ,concentrated coolent in sealed packing suitable for diesel engine of any type /make and capacity. Complete all as directed. Make - Volvoline / servo/ castrol
Supply and filling distilled water in sealed packing suitable for DC12 volt battery, Complete all as directed.
S&F in repairs , battery terminals made of brass,suitable for battery of any type /make and capacity. Complete all as directed.
S&F in repairs , battery 12 volt , 180 AH. Cat pt No.FCPO-CP 180R (MF) OF Exide/Amron/Power safe.
Supply,install,testing and commissioning of LT indoor panel of suitable size 3 phase and neutral 415 volts fabricated out of 2.8 mm thick CRCA sheet powder coated ,front and back door openable suitable for and including 65x10 mm size copper bus bar, mounted on suitable DMC insulator and insulated with PVC sleeve not less than 2 mm thick and duly colour coated with (red,yellow,blue,and black) internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame to be used for bottom of the penal board ,IP 54 protection 30 cm blow ground level and 60 cm above ground leval ,grouted by using PCC foundation 1:2:4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland including painting with two coat of powder coated paint complete and taking down old panel and connecting all cables incoming and outgoing by suitable lugs and connecting all with and including items catered under srl No 110.01 to 110.08 here-in after:-(Note- all the outgoing MCCB's must be connected with suitable size copper strips bent to shape duly insulated as mentioned above with suitable insulator support (CPRI approved) Location: MT Pump House
Incoming MCCB 100 Amps 4 pole 25 ka-1
Outgoing MCCB 63 Amps 4 pole 25 ka-1
Automtic Star delta 10 HP 7.5 KW (9Amp-13 Amp) as per IP 54 with CRCA Sheet steel material 50 Hz, 415 volt -1
LED indicating Lamp -4
Single phase preventer -1
Bus bar ratid 150 amp 3 phase neutral
Supply,install,testing and commissioning of LT indoor panel of suitable size 3 phase and neutral 415 volts fabricated out of 3 mm thick CRCA sheet powder coated ,front and back door openable suitable for and including 65x10 mm size copper bus bar, mounted on suitable DMC insulator and insulated with PVC sleeve not less than 2 mm thick and duly colour coated with (red,yellow,blue,and black) internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame to be used for bottom of the penal board ,IP 54 protection 30 cm blow ground level and 60 cm above ground leval ,grouted by using PCC foundation 1:2:4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland including painting with two coat of powder coated paint using seven tank process complete and taking down old penal and connecting all cables incoming and outgoing by suitable lugs and connecting all with and including items catered under srl No 111.01 to 111.14 here-in after-(Note- all the outgoing MCCB's must be connected with suitable size copper strips bent to shape duly insulated as mentioned above with suitable insulator support (CPRI approved)) Location: MAP Pump House
Incoming MCCB 160 Amps -1
Outgoing MCCB 100 Amps-2
Start delta starter 15 HP -2
LED indicating Lamp -1
Incoming MCCB 160 Amps 4 pole 25 ka -1
Outgoing MCCB 100 Amps 4 pole 25 ka-1
Star delta starter -15 HP (13 Amp - 22 Amp) as per IP 54 with CRCA Sheet steel material 50 Hz, 415 volt -1
LED indicating Lamp -4
Single phase preventer -1
Bus bar ratid 150 amp 3 phase neutral
Mild steel framed work as in ladder/tank covers for OHT/UG sumpetc, with ends of bars shouldered and / or riveted or forced in spikes and similar works conforming to Fe-290 Gde-E-165 including structrual steel is painted two coats of synthetic enemal paint over a shop coat of zinc chromate primer paint (incl prepration of surface) complete all as specified and directed. Location: Pump House No. 1, Pump House No. 2, Underground Sump
CHOUDHARY ELECTRICAL
SHIVA ENTERPRISES
Dayal Enterprises
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .