| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC 16 1 DWARIK BHATTERJEE LANE BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742103 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹23.6 L+₹1.3 L (6.04%)Rejected-AOC 122 MANINDRA ROAD KHAGRA BERHAMPORE MURSHIDABAD WEST BENGAL 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹23.9 L+₹1.7 L (7.47%)Rejected-Finance DANGALPARA P O P S SURI BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹46,885
Closing Date
23 Oct 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,PWD,Birbhum Electrical Division
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Electrical installation work for Blood Bank at Bolpur SDH ,Birbhum.
2021_WBPWD_345933_1
BIRED/24/e-NIQ (2nd call) of 2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
SDH, Bolpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹46,885
Office of The Exe Eng,PWD,Birbhum Elec Divn
2 Nov 2021
29 Sept 2021
26 Oct 2021
29 Sept 2021
23 Oct 2021
4 Oct 2021
4 Oct 2021
120 days
Amount
Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light/fan/call bell points as per GS with following average run 8 Mtr. [ 2(a)(iii) / E-9 ]
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall] to light / Fan / Call bell point as per GS withfollowing average run. 8 Mtr. [ 5(c) / E-15 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS. On Board [4a (i) / E- 10 ]
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB as per GS [ 24/E-7 ]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS [ 22 /E-6 ]
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall as per GS. [28/E-7]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17]
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E19 ]
S&F AC machine timer DB for one no. Single phase Split type machine febricated with following item as per instruction of EIC --- i) 240V, 32 DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)--1no ii) 22A 2Pole Power Contactor with 220V coil voltage, ( L&T, Cat No. MNX22-2P, CS90238 )---1 No. iii) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no iv) Toggle switch for manual/auto operatio--- 1no. v) double door 8Way SPNDB as per L&T Cat no-LTSDO8N)- 1No vi) 240V, 32 SP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)--1no vii) necessary connection by copper wire. [NS]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 240 mm x 200 mm x 65 mm [11(e) & 12(e)/E4 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+14Way [ Legrand ] [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 6 Way [ 14 / D- 10 ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS ( Make - Legrand ) 12 Way ( Up to 160 A ) [15 / D- 11 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP [ 6 / D- 5 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 125 A FP [ 10/ D- 8 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 A SP [ 7 / D- 6]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. 2x(1.5 sqmm)+1x(1.5 sqmm) [ 1(b) / E-9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug) [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) (For Split type A.C Machine) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) (For TPNDB to SPNDB) [ 1 (y) / E- 9 ]
4x (6 sqmm) + 2x (4 sqmm) (For 3 phase industrial power socket) [ a(1) / E- 9 ]
4x(16 sqmm)+2x(10 sqmm) [ g(1) /E- 9 ] (From VTPNDB to TPNDB)
Supplying and fixing polythene pipe (3mm thick) complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire as 13mm inner dia [ 1(a) / E-2 ]per GS.
19mm inner dia [ 1(b) / E-2 ]
Cutting Channel of size (31 mm x 31 mm)/(40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. 13 mm inner dia 3 mm thick [ 5(a)/ E- 2 ]
19 mm inner dia 3 mm thick [ 6 (a)/ E- 3 ]
25 mm inner dia 3 mm thick [ 7 (a)/ E- 3 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5sqmm [ NS ]
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
6 sqmm [9 (iii)/F-5]
10 sqmm [9 (iv)/F-5]
16sqmm [9 (v)/F-5]
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Currency / Gloster/Finolex] 4 core 70 Sq. mm [ NS ]
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire as per GS 35 to 95 Sq. mm [ 6(ii)/ F- 3 ]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 1 No Cable [2(d)/F-1 ]
Supplying and fixing compression type gland and finishing those for following XLPE armoured cable (2/4 / 3.5)Core as per GS. 4 Core 70 Sq. mm [7(d)/F4 & 8(b) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS 100mm dia [11(g)/F-6]
Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp as per GS [17/C-2]
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener [14(b)/C-2 ]
Supply of 4 Ft. 18 Watt single/twin florescent light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips/Crompton) [NS] a. 1xTLD 18W LED ( TMC 501/Similar model )
b. 2xTLD 18W LED ( TMC 501/Similar model )
Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS [ 18 (a) / E-6 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA as per GS [ 31/D-14 ]
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop [ 24 (a) / C-3 ]
Extra for additional one letter incl. hifen, stroke and stop as per GS [24 (b) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS. [ 26 (a) / C-3 ]
Extra painting for additional one letter of the engraved number as per GS [ 26 (b) / C-3 ]
Fixing only exhaust fan after making holes in wall as per GS (12'') (28(b)/C-4)
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12") [ 33/D-14 ]
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves/USHA ) a. 1200 mm Sweep ( Aura/Striker Galaxy) [ NS ]
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 12" ( 300mm ) Speed 1420 RPM [ NS ]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS [ 20( a )/D-13 ]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS.( Make -L&T ). 250A [4(a)/D-3]
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Morum Soil [1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm as per GS [3(a)/G-2 ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on as per GS [4(c)/G-2 ]
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat as per GS [5(d)/G-3 ]
SITC of 2.0 Ton Split type A.C. machine having the following specification & feutures:- a) Cooling capacity (Maximum) (BTU /HR): 24272; cooling capacity(Rated) Guaranted(BTU/HR):24000 b) Star Rating -3 star c) Rated Voltage-230 V + / -5%, Frequency -50 Hz d) Compressor type- Rotary e) Mini. Room Discharge Air Flow Rate-1400CMH f) Refrigrant: R-410A/R32 g) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) Out door operating Temperature:-50c (Minimum) i) PCB control unit of indoor unit should be covered by metalic enclosure. With 15A plug top, 2mt long input cord ,& all other installation kit including3mtr 15.88mm &6.35mm copper pipe with keno foam insulation for indoor to out door unit connection, out door unit will be fixed on wall with heavy type wall base. Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor as per instruction of EIC.( Make-Hitachi/Daikini/Carrier or As per choice of EIC)
SITC of 1.5 Ton wall mounted type room Air conditioner(cooling only) having the following specification & feutures:- a) Cooling capacity nominal (BTU /HR): 20500; cooling cap(min) Guaranted(BTU/HR):20216 b) Star Rating -3 star c) Rated Voltage-230 V + / -5%, Frequency -50 Hz d) Compressor type- Rotary e) Mini. Room Discharge Air Flow Rate-1300CMH f) Refrigrant: R-410A/R32 g) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing h) PCB control unit should be covered by metalic enclosure. i) Out door operating Temperature:- 50c(Minimum) With 15A plug top, 2mt long input cord ,& all other installation kit including3mtr 15.88mm &6.35mm copper pipe with keno foam insulation for indoor to out door unit connection, out door unit will be fixed on wall with heavy type wall base. Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor as per instruction of EIC.( Make-Hitachi/Daikini/Carrier or As per choice of EIC),
S&F 15.88mm&6.35mm copper pipe with keno foam insulation & 3core 2.5Sqmm&4 core 1.55qmm copper un aurmored cable. [ for connection of plug socket to out door unit & out door to indoor unit]
S & F 15mm PVC flexible drain pipe.
Supply & Installation of suitable size iron grill protection(cage) for outdoor unit of 1.5/2.2 Ton Split type A.C. Machine made with 25 mmX25mmX6mm thick M.S Angle & 19 mmX6mm M.S flat bar of base size 320mmX1160mmX750mm width , covering with complete painting with two coats of metal primer and two coats of ici synthetic enamel, fixing the same on outer wall, roof top by cc & plastering the same to the original finish incl. 5 liver Godrej Novtal Lock incl. painting.
Designing, fabrication, supply, installation, testing & commissioning of outdoor type LED sinage (approx. size10ft X 3ft = 30 sqft ) in Bengali or English (Letter given and approved by concerned Authority) for letter with following specification. a) The box for sinage will be fabricated in all aluminium square tube of size of 25mm x 25mm 16 SWG gauge complete with necy. Priming & painting. The front of the box will be covered with 3 mm thick Al. composite Panel (ACP) sheet of the entire board. The board to be fixed in front of canopy by providing required support & angle bracketing. The composite installation will be water, vermin and dust insulated and protected. b) Letter description approx. 30" x 15" size of letter made of acrylic sheet with male female attachment on router cut ACP sheet of front incl. all accessories as required. c) LED illuminition High Bright wave length closed type water proof white LED module (1.2 W) mounted on interior side of female part of letter with power wire running back to central power area with 12V LED power transformer to adequately drive the whole LED module with flicker.d) Internal electrical wiring will be done by Halogen free frame retardent HRFR compound insulated (unsheathed) 3 core 1.5 sq.mm copper flexible cable as required through interior conduit and electrical raceway.
Note:- Labour welfare Cess @ 1% and GST @ 12% on Bill amount will be deduct.
M/S. PROTIVA ELECTRIC WORKS
RIK ENTERPRISE
stage.html
html • 0.05 MB
technical_663710.pdf
PDF • 0.91 MB
techsummary_663710.pdf
PDF • 0.08 MB
finance_663710.pdf
PDF • 0.91 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_663710.pdf
PDF • 0.13 MB
20211102161953.pdf
PDF • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .