Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹5.5 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹6.8 LRejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹6.8 L | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹7.2 LRejected-Finance | ₹7.2 L | L3 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | FG CONSTRUCTION L1 | M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR L3 | VEDA INFRASTRUCTURE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable street/security light fittings along the perimeter wall/ fencing/ Street light by using ladder in hilly areas, any type of security light fitting of any capacity any type from pole/wall after disconnection from the connecting wires, carrying to store yard for necessary repair/replacement of spares etc complete all as specified and as directed. | 8 | Each | 700 ₹5,600 | 600 ₹4,800 | 50 ₹400 |
| 2.00 | Refixing only the street light fittings after repair along the perimeter wall/fencing /Street light by using ladder in hilly areas, obtained from item No.01 here in before including making connections with cables and testing complete all as specified and as directed. Note for Item Nos. 1 & 2 : (a) Any new spares including cable required to be replaced shall be measured and paid separately.
(b) Necessary T&P, Safety Belt, Aluminium Ladder, Vehicle etc required for taking down will be arranged by the Contractor and cost for the same shall deemed to be included in the Quoted Unit Rate. | 8 | Each | 800 ₹6,400 | 600 ₹4,800 | 100 ₹800 |
| 3.00 | Supply and laying of XLPE under ground insulated, armoured, heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed including taking out the old burnt out cables all as specified and directed by Engr-in-Charge. | 240 | RM | 160 ₹38,400 | 300 ₹72,000 | 150 ₹36,000 |
| 4.00 | All as Srl item No. 3.00 above but of size 4 core 25 Sqmm | 90 | RM | 250 ₹22,500 | 330 ₹29,700 | 300 ₹27,000 |
| 5.00 | All as Srl item No. 3.00 above but of size 3.5 core 35 Sqmm | 60 | RM | 295 ₹17,700 | 340 ₹20,400 | 390 ₹23,400 |
| 6.00 | All as Srl item No. 3.00 above but of size 3.5 core 50 Sqmm | 120 | RM | 390 ₹46,800 | 360 ₹43,200 | 460 ₹55,200 |
| 7.00 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in any type of soil for taking up or laying of cable all as specified and directed. | 117 | Cum | 130 ₹15,210 | 150 ₹17,550 | 100 ₹11,700 |
| 8.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. | 68 | Cum | 70 ₹4,760 | 100 ₹6,800 | 20 ₹1,360 |
| 9.00 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc 1.5M above the starting point | 49 | Cum | 70 ₹3,430 | 100 ₹4,900 | 30 ₹1,470 |
| 10.00 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness shall be measured and paid | 35 | Cum | 750 ₹26,250 | 700 ₹24,500 | 800 ₹28,000 |
Updated dates
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 May 2026, 6:00 pmClosed
AGE I CIF K
AGE I CIF K CO 56 APO
REPAIR AND MAINT OF HIGH MAST LIGHTS AT HQ CIF(K) UNDER AGE (I) CIF (K)
2026_MES_760103_1
AGE (I) CIF (K) - 01/2026-27
Open Tender
Electrical and Maintenance Works
270 days
Shalateng
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE I CIF K Srinagar
₹20,000
19 May 2026
11 Apr 2026
16 May 2026
11 Apr 2026
14 May 2026
25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Taking down existing unserviceable street/security light fittings along the perimeter wall/ fencing/ Street light by using ladder in hilly areas, any type of security light fitting of any capacity any type from pole/wall after disconnection from the connecting wires, carrying to store yard for necessary repair/replacement of spares etc complete all as specified and as directed. | - | Each | - | - | |
Refixing only the street light fittings after repair along the perimeter wall/fencing /Street light by using ladder in hilly areas, obtained from item No.01 here in before including making connections with cables and testing complete all as specified and as directed. Note for Item Nos. 1 & 2 : (a) Any new spares including cable required to be replaced shall be measured and paid separately.
(b) Necessary T&P, Safety Belt, Aluminium Ladder, Vehicle etc required for taking down will be arranged by the Contractor and cost for the same shall deemed to be included in the Quoted Unit Rate. | - | Each | - | - | |
Supply and laying of XLPE under ground insulated, armoured, heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed including taking out the old burnt out cables all as specified and directed by Engr-in-Charge. | - | RM | - | - | |
All as Srl item No. 3.00 above but of size 4 core 25 Sqmm | - | RM | - | - | |
All as Srl item No. 3.00 above but of size 3.5 core 35 Sqmm | - | RM | - | - | |
All as Srl item No. 3.00 above but of size 3.5 core 50 Sqmm | - | RM | - | - | |
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in any type of soil for taking up or laying of cable all as specified and directed. | - | Cum | - | - | |
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. | - | Cum | - | - | |
Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc 1.5M above the starting point | - | Cum | - | - | |
Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness shall be measured and paid | - | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
TENDER.pdf
Tender Documents • 1.94 MB
BOQ_851389.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid