Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.3 LAccepted-AOC AT PANCHAMAHAL PO KARADAGADIA ANGUL ODISHA 759132 | ANUGUL | ODISHA | 759132 | L-1 | Accepted-AOC ACCEPTED AND AWARDED BY COMPETENT AUTHORITY | |
| 2 | L-2₹7.7 L+₹68,177.02 (9.72%)Rejected-Finance AT ITI CHHAK PO TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | L-2 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 3 | L-3₹7.7 L+₹71,498.91 (10.2%)Rejected-Finance AT PO DANARA TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L-3 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 4 | L-4₹7.9 L+₹85,684.36 (12.2%)Rejected-Finance AT PO REMUAN TALCHER DIST ANGUL ODISHA 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-4 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 |
Tender Value
₹11.9 L
EMD Value
₹14,900
Closing Date
28 May 2024, 5:00 pmClosed
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER, LINGARAJ AREA, AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Stop gap arrangement for the work of Erection, Dismantling and other related works in overhead line of 3.3KV Power feeder No. 01, 02, 10 and 13 drawn from Sub-station to quarry, as and when required time to time during advancing of mine including any
2024_MCL_308344_1
GM/LA/SO/EnM/e-Ten/24-25/12 DT-17.05.24
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
LINGARAJ OCP
AS PER NIT
4 documents required · 4 mandatory
₹14,900
26 Jun 2024
17 May 2024
30 May 2024
18 May 2024
28 May 2024
18 May 2024
18 May 2024 - 21 May 2024
Amount
Erection of Metallic pole of following length in cement concrete 1:3:6( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required. Above 10.00 metre and upto 12.00 metre.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of stay set complete (galvanised) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Erection of Disc/pin nsulator for 11kv O/H lines as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Erection of G.I wire 8/6 SWG including binding etc as required.
Supply of 6 SWG G.I. wire
Supply of clamps with M.S. nut,bolts and washers as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Erection of Cradle Guard as required.
Erection ,commissioning and testing of 11KV GOAB switch on double pole mounted structure. etc as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, Cl. wire, cross arms, insulators etc. as required.
Total of 2 Unskilled manpower for tree triming work in the 3.3KV power feeders.
Total of 2 Unskilled and 2 Skilled manpower for fault finding,Jumpering and OH line meggering work in the 3.3KV power feeders.
Dismantling of stay embedded in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work (1mtr length for pole demarcation)
Lettering with black Japan paint of approved brand and manufacture (For pole & feeder numbering)
Supplying of 11KV pin insulator with stud
Supplying of 11KV disc insulator for 11KV over head lines with hardware
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s Santoshi Maa Industries
Sachin Kumar Pradhan
MESSERS UTKAL ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_319499.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .