Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.5 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L1 | Accepted-AOC QUOTED L1 | |
| 2 | L2₹77.1 L+₹3.6 L (4.85%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC NOT ADMITTED | |
| 3 | L3₹79.4 L+₹5.9 L (8.05%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L3 | Rejected-AOC NOT ADMITTED | |
| 4 | L4₹80.9 L+₹7.4 L (10.0%)Rejected-AOC | L4 | Rejected-AOC NOT ADMITTED | |
| 5 | L5₹81.0 L+₹7.5 L (10.3%)Rejected-AOC | L5 | Rejected-AOC NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
8 Dec 2020, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO RESIDENTIAL BUILDINGS PARVATI AND POORNIMA AT CSD ESTATE GHATKOPAR UNDER GE NW MANKHURD
2020_MES_391976_1
8859/E8
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.7 L
Yes
31 Dec 2020
10 Nov 2020
12 Dec 2020
10 Nov 2020
8 Dec 2020
25 Nov 2020
Amount
Taking down chowkats or frames, not exc 1.5 sqm each with wooden/ flush / PVC shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of MS Grills (where exists), complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 sqm but not exc 4 Sqm each with wooden/ flush shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of MS grills (where exists), complete all as specified and directed.
Taking shutters (without taking off shutters from the frame) not exceeding 2sqm each. and refixing the same in the same opening after complete cleaning and when the repair work is complete all as specified and directed.
M&L for kiln seasoned and chemically pressure treated second class Hard Wood (SAL/Hollock/Kalasiris) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints etc complete all as specified and directed.
S & F factory made 35mm thick plain, framed panelled shutter (two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm veneered particle board with commerical veneering on both faces, the size of rails and stiles shall be as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated of 2nd class hard wood (Hollock/Sal/Kalasiris), complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as speicified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') complete all as speicified and directed.
M& L for preparation of new steel and iron surfaces of any description , over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome, complete all as specified and directed.
M/L preparing old wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wood and wood based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S & F Powder coated aluminium section for sliding / openable window / doors of reqd size medium weight section, plain glass on and aluminium wire cloth shutters with two nylon roller on each shutters including star lock handle, soft rubber gasket or aluminium glazing beading fixed with nickel plated screws complete all as specified and directed Note (i) : Glass & wire cloth required shall be measured and paid separately.
Supply only 4mm thick figured glass, pinhead type for aluminium joinery, complete all as specified and directed.
Supply only aluminium wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm for aluminium joinery, complete all as specified and directed.
Supply only 5mm thick plain sheet glass, ordinary quality for aluminium joinery, complete all as specified and directed.
S&F in repairs 20mm dia Harrison rails, mild steel, chromium plated, curtain rails with and including fixing brackets, stops, rollers etc, complete all as specified and directed.
S&F Hasp and staple of 150 mm, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed in repairs complete with screws all as speicified and directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
M&L for 20 to 25 mm thick machine cut pre-prolished cuddappa stone Slabs (table rubbed and polished) as in cills, jambs, soffits, cooking platform etc, pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab etc, including moulding/rounding to edges of the slab and also including provision of 15mm thick screed bed in CM 1:4, complete all as specified and directed.
S & F factory made solid FRP Door Frame of size 50mm x 47mm made out of 5mm plain colour FRP sheet reinforced with M.S. Square tube, complete all as specified and shown in drg for SI No. 8095 on ser page No. 160 in SSR-2010 (Pt-II).
S&F Factory made solid panel FRP door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S.frame shall be covered with heat moulded plain colour FRP' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour FRP sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet shall be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing-for S.I No. 8080 on Sr page No. 156 in SSR-2010(Part II) complete all as specified and directed.
Supply and fix stainless steel butt hinges of size 100mm, complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed.
M&L for 12 mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing surfaces even and smooth, complete all as specified and directed, Make: Build well RMP from M/s Walplast or chemplast or readyplast from Ultratech Note: The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with ready mix plaster and nothing extra shall be payable on this account.
M&L rendering 15 mm thick on stone masonry/brick masonry other than fair faces of brick surfaces in CM(1:6) finished even and smooth with out using extra cement complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions, as specified & directed. Notes: (i) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L Preparing new plastered surfaces and applying two coats of oil bound distemper over a coat of 3 mm thick wall care putty on plastered and other services over a coat of primer ,preparatory to distempering on walls complete all as specified and directed.
M&L Preparing old plastered surfaces after complete removal of old treatment and applying two coats of oil bound distemper over a coat of 3 mm thick wall care putty on plastered and other services,preparatory to distempering on walls complete all as directed.
M&L rendering 5 mm thick in CM 1:3 on ceiling surfaces including finishing the surfaces even and smooth without using extra cement complete all as speicified and directed
M&L for preparation of new plastered surfaces of ceiling and applying two coats of Oil bound distemper with roller over a coat of 3 mm thick wall care putty and one coat of primer ,complete all as speicified and directed.
M&l for complete removal of existing treatment of ceiling by brooming down or steel wire brushing scrapping dwon soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water etc applying two coats of oil bound distemper with roller over 3 mm thick putty and one coat of primer complete all as specifid and directed.
Dismantaling stone slabs and tiles of any description or thickness in floors ,aprons etc .laid bedded and pointed in any mortar complete all as speicifeid and directed.
M&L for coloured 450x300x6 mm to 7 mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
M&L for Light Shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) of approved size, area of each tile not exceeding 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for coloured Non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
S&F in repairs gunmetal gate valve, ISI marked with iron wheel head, screwed at both ends for iron pipe or ferrule of 20mm bore and provision of necessary fittings like unions, check nuts, etc, complete all as specified and as directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 3330mm x 160mm complete all as specified and directed.
Taking up or down steel water tubing and connections of size 15mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 20mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 25 mm bore, complete all as specified and directed.
S&F 16 mm 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
Supply & fixing 20mm bore GI tubing, medium grade with and including all fittings and concealed/or fixed over wall and ceilings or laid in floors, complete all as specified and as directed.
Supply & fixing 25mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
S&F in repairs Vitreous China white, 1st quality, wash hand basin, flat back, size 550mm x 400mm including mild steel angle brackets,CP brass fittings, waste, union, 32mm dia PVC waste pipe, cutting for and pinning ends of brackets, complete all as specified and directed .
S&F 15mm bore brass CP pillar tap, fixed in repairs complete all as specified and directed.
S&F 15mm bore brass CP Stop Valve, fixed in repairs complete all as specified and directed.
S&F 15mm bore brass CP Bib Tap, fixed in repairs complete all as specified and directed.
S&F in repairs brass chromium plated, shower rose, 125mm size with and including 195mm long 15mm bore brass chromium plated shower arm with bend of 45 degree, complete all as specified and directed.
S&F brass CP towel rail 600 mm long fixed in repairs with and including chromium plated screws on walls, complete all as specified and directed.
S&F in repair Grating doom 125 mm dia with waste hole of PTMT (Minimum Weight 25 gram), complete all as specified and directed.
S&F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints,fix to wall,100mm bore sand cast pipe complete all as specified and directed.
S/F Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, fix on wall,75 mm bore sand cast pipe complete all as specified and directed.
S&F CI Bend 100 mm dia with oval access doors complete all as specified and directed.
S&F CI Bend 75 mm dia with oval access doors complete all as specified and directed.
S&F CI 'Tee' junction 75 mm dia,single complete all as specified and directed.
S&F Cast Iron soil cowl100 mm dia complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors, 75mm single socketed complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortor of any dia, complete all as specified and directed.
S & F of 75 mm bore uPVC (SWR) soil, waste, ventilating rain water pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary PVC standard stay clamps etc, including taking down existing SWR pipes(including fittings) of any description, complete all as specified and directed.
S & F 110 mm bore uPVC (SWR) soil, waste, ventilating, rain water pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary PVC standard stay clamps etc, including taking down existing SWR pipes(including fittings) of any description, complete all as specified and directed.
S&F uPVC vent cowl 110mm bore with and including rubber ring joints, complete all as specified and directed.
S&F 75 mm bore uPVC (SWR) Bends/Shoes with and including rubber ring joints, complete all as specified and directed.
S&F 110 mm bore uPVC (SWR) Bends/Shoes with and including rubber ring joints, complete all as specified and directed.
S&F in repairs PVC (SWR) Nahani trap with 75mm dia out let including grating, connecting, jointing to waste pipe with lead joints, also including embedding the same in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
S&F in repairs, white, vitreous China, wash down water closet pan (pedestal pattern), Ist quality, inlcuding plastic water closet seat white, closed pattern with flat bottom and cover and Mild Steel CP or aluminised hinging device, complete all as specified and directed. Note: Flushing cistern, flush pipe will be measured separately.
M&L hand shower (Health faucet) with 1.00 mtr long easy flex tube in chrome finish & wall hook as approved by the GE , complete all as speicified and directed.
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia, complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450 mm and above, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping, bed blocks, roof curb, mud stops, coving at junction of wall and chajjas etc including weathering, slightly rounded or chamfered angles, provision of necessary form work, complete all as specified and directed.
Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land complete all as specified and directed.
M&L for Pre cast cement concrete block masonry with solid block of grade(C-5) having block density not less than 1800 Kg/cum, exc, 10cm in width and setting in CM 1: 6, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1 ,complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate mixed with water proofing compound @ 2% by weight of cement for fixing of nahani trap or floor trap/ water proofing of sunken slab etc including demolition of existing PCC and removal of debris outside MD land complete all as specified.(WPC shall be measured separately)
M&L for cement concrete type E-2,1:5:10 (using 40 mm graded aggregate) as in sunken portion of toilet and bathroom including demolition of existing concrete bedding and removal or debris outside MD land complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4, on fair faces of brick or concrete surfaces finishing even and smooth without using extra cement on sunken portion of toilet and bathroom mixed with 3 % WPC complete all as specified and directed (WPC shall be measured and paid seperately)
M&L for applying evenly a tack coat of industrial bitumen 85/25 @1.20kg/sqm including cleaing the surfaces over newly plastered surfaces of sunken portions complete all as specified and directed
Supply only intergal water proofing compound, complete all as specified and directed.
Demolition of reinforced cement concrete of any description as in slabs, beams, columns and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilitate demolition and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for RCC 1:1.5:3, type A1 (using 20 mm graded stone aggregate) as in slabs/chajja/beams supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, dec slab and in shelves, beams, colums ,chajjas and the like, complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid for separetely.
M&L for CRS TMT steel bars 10mm dia and over in reinforcement cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and directed.
M&L for CRS TMT steel bars 5mm dia and over, upto and including 10mm dia as in strirups, spacers, binders cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs/chajja/beams, floor slabs, landing and similer work, soffits and sides of beams and chajja etc, for fair finished surfaces, complete all as speceified and directed.
Chipping, removing carefully loose/ damaged concrete (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. Note:- Mode of measurement: superficial area of concrete will be measured.
M&L for shear connectors of 8mm dia TMT bars including anchoring of the reinforcement bars in existing RCC members by providing holes of minimum 10d depth and grouting in position with locfix (fosroc), including drilling of holes, cleaning and other relevant works, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still sticking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L building up the profile of structural members using polymer modified mortar of Krishna Conchem (Molith PMM) or polymer mortar HB of Dr Fixit while the bonding agent is sticking upto 40 mm thickness (of 20x20 mm each in 2 layers) including levelling ,profiling etc complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately)
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity etc, complete all as specified and directed.
M & L for point wiring complete with proper colour coding, using 1100 Volts grade, 1.5 Sqmm, PVC insulated, FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 25mm width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel terminal boxes not less than 1.6 mm thick, 50 mm deep covered with 3mm thick plastic laminated sheet top cover fastended with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed.
All as per item No. 99 above but for One 2pin/3 pin socket outlet 5 Amps on same board complete all as specified and directed.
All as per item No. 99 above but for One 2 pin/3 pin socket outlet 5 Amps on independent board.
M&L for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductor drawn in and including PVC casing caping (minimum 25mm in width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel terminal box not less than 1.6 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated sheet top cover fastened with chromium plated brass screws, also including 2.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent, complete all as specified and directed.
S&F Switch Piano 5 Amps, 230 Volts, one way, flush type, complete all as specified and directed.
Supply & Fix Bell push, flush type, 5 Amp, 230 Volts, complete all as specified and directed.
S&F ceiling rose three terminal, 230 Volts, PVC / Polycarbonate body, complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5 Amps, flush type, 5 Pin, 230 Volts, complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5/15 Amps, flush type, 6 Pin, 230 Volts, complete all as specified and directed.
S&F fan regulator, electronic stepped (5 step), 230 volts, 100 watt, flush type and connecting-up, complete all as specified and directed.
Supply and fix bell ding dog type, AC, 230 V, single pole, complete all as specified and directed.
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S&F MCB DB, TPN, double door, 6 way IP 43 metal body having earth terminal, neutral bus terminal for 6 way circuits complete in all respect fixed on wall including making electrical incoming and out going connections with lugs/thimbles complete all as specified and directed.
S & F MCB, SPN, 06 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, SP, 06 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, TPN, 40 to 63 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F 10 W surface/wall mounted LED tube light fitting having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S & F 20 W surface/wall mounted LED tube light fitting having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
Supply and fix in repairs 30 watt LED street / security light fittings suitable for and including 1 x 30 Watt LED lamp , in built fittings etc, with all accessories, pre-wired, also with and including GI steel tube light grade 40mm bore bracket of length upto 1.5 mtr, bent to shape of off set angle upto 45 degree for fixing street light fittings, including providing necessary MS Clamps, nuts, bolts etc, all as specified and directed, Cat No. ENXT P 30L WH CR PC SD of Bajaj or equivalent from Philips/Crompton as approved by the GE.
Taking down existing earthing and in lieu M&L for new earthing complete with galvanised earth plate electode 600 x 600 x 6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level, connected to and including galvanised earth wire 4mm dia to the extent upto 7.5 metre as earth lead by means of bolts, nuts etc, with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I, including water arrangement with GI pipe 20mm bore (medium grade), earth lead protection pipe 15mm bore light grade with bends, elbow etc. from earth plate to test point, excavation and earth work, returning, filling, ramming and removing of soil to a distance not exc 50 metre, making PCC 1:2:4 type B-1 pit (Earth chamber) with RCC 1:2:4 cover 50mm thick reinforced with XPM and testing on completion including making test point on wall as per SSR specifications all as specified and directed. (Note: Cost of GI earth wire and protection pipe upto 7.5 metre shall also be deemed to be included in the quoted rate).
M & L for sub main wiring complete with Two runs of 6.0 Sqmm PVC insulated, unsheathed, heavy duty, 1100 volt grade multi-stranded copper conductor cable (FRLS), drawn in and including PVC casing caping fixed on the surfaces of walls, RCC slab/ ceiling/columns / beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 6.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continuous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Two runs of 6.0 Sqmm PVC cable, one run of 6.0 Sqmm cable and one run of Casing Caping will be measured as 'one unit' length.
Taking down of existing ceiling fans and re-fixing of the same ceiling fan 1200mm sweep including provision of cable from ceiling rose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed.
Supply and fix clamping saddlels made out of aluminium sheet of thickness not less than 1.6mm of size 20mm as per site requirement.
Parmatma Enterprises
Vishal Builders
RAJU AND CO
SUNRISE CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .