Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹1.2 Cr Quoted ₹1.3 Cr | 1 | Accepted-AOC Being lowest |
| 2 | 2₹1.6 Cr+₹31.2 L (23.4%)Rejected-Finance VILLAGE POST PATHOLI AGRA UTTAR PRADESH INDIA | ₹1.6 Cr+₹31.2 L (23.4%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹1.7 Cr+₹36.5 L (27.3%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹1.7 Cr+₹36.5 L (27.3%) | 3 | Rejected-Finance Not being lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
15 Feb 2022, 6:00 pmClosed
HQ CWE Agra
112 Taj Road, Agra Cantt
AUGMENTATION OF WATER SUPPLY DISTRIBUTION AND REPLACEMENT OF CORRODED GI PIPES AND PANELS UNDER GE (WEST) AGRA
2022_MES_500905_1
84239/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class B category a(ii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE West Agra
₹2.2 L
Yes
23 Mar 2022
11 Jan 2022
21 Feb 2022
11 Jan 2022
15 Feb 2022
1 Feb 2022
11 Jan 2022 - 18 Jan 2022
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed at site.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed at site.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed at site.
Taking up or down steel tubing and connections 100 mm bore, including CPVC and HDPE pipes complete all as specified and directed at site.
All as per item No 4 above but 80mm bore complete all as specified and directed at site.
All as per item No 4 above but 50mm bore complete all as specified and directed at site.
All as per item No 4 above but 40mm bore complete all as specified and directed at site.
All as per item No 4 above but 25mm bore complete all as specified and directed at site.
All as per item No 4 above but 20mm bore complete all as specified and directed at site.
Supply, laying and jointing for the 25 mm bore 3 layer PPR-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling on in floors fixing with the help of MS clamp of suitable size at a distance of not more than 2 RM from each and connecting with existing line complete all as specified and directed at site.. Make SFMC or equivalent
All as per item No-10 above but 20mm bore complete all as specified and directed at site..
Supply, laying and jointing for the 100mm bore in trenches/on floor/wall, galvanized steel tubing medium grade including ISI marked GI fittings, including cutting to reducing length, screwing and connecting with existing line including fix existing connection with required size of Tee or MS clamp with rubber bush complete all as specified and directed.
All as per item No-12 above but 80mm bore complete all as specified and directed at site.
All as per item No-12 above but 50mm bore complete all as specified and directed at site.
All as per item No-12 above but 40mm bore complete all as specified and directed at site.
All as per item No-12 above but 25mm bore complete all as specified and directed at site.
All as per item No-12 above but 20mm bore complete all as specified and directed at site.
Taking up/down 100mm bore of cast iron/ductile iron water mains(including all fittings), with spigot and socket ends and lead joints including burning out joints and receiving lead complete all as specified and directed at site.
All as per item No-18 above but 150mm bore complete all as specified and directed at site.
All as per item No-18 above but 200mm bore complete all as specified and directed at site.
All as per item No-18 above but 250mm bore complete all as specified and directed at site.
All as per item No-18 above but 300mm bore complete all as specified and directed at site.
M&L for 100 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends conforming to IS 8329/2000 any length for classification of K9 including rubber gasket joint (push on type) with cement mortar lining inside the pipe with outside zinc coating complete all including existing connection with required size of Tee or MS clamp with rubber bush complete all as specified and directed at site.
All as per item No-23 above but 150mm bore complete all as specified and directed at site.
All as per item No-23 above but 200mm bore complete all as specified and directed at site.
All as per item No-23 above but 250mm bore complete all as specified and directed at site.
All as per item No-23 above but 300mm bore complete all as specified and directed at site.
M&L Cutting existing Cast Iron/DI pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 100mm bore of pipe complete all as specified and directed at site.
M&L Cutting existing Cast Iron/DI pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 150mm bore of pipe complete all as specified and directed at site.
M&L Cutting existing Cast Iron/DI pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 200mm bore of pipe complete all as specified and directed at site.
M&L Cutting existing Cast Iron/DI pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 250mm bore of pipe complete all as specified and directed at site.
M&L Cutting existing Cast Iron/DI pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 300mm bore of pipe complete all as specified and directed at site.
M & L for road cutting for laying of pipe line and making good after laying to match with surrounding area with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for a depth of 30 cm from top and balance portion shall be filled with approved earth complete all as specified and as directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using necessary machinery and labour for laying underground pipe GI/DI up to size 300mm complete all as specified and directed at site.. Note : Pipes will be measured and paid separately.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed
Taking down of old unserviceable PVC Stop valve S&F new PP-R gate valves (brass insert) including fittings such brass male sockets of size 25 mm including cutting of existing GI pipe or as required at site and fixing properly all as specified and directed.
All as per item No. 36 above but of size 20mm dia complete all as specified and directed at site..
Taking down of old unserviceable PVC Stop valve S&F new GM gate valve ISI marked IS-778 screwed down for iron pipe or ferrule including fittings such as union , socket, nipple , check nut etc of size 50mm including cutting of existing GI pipe and fixing properly complete all as specified and directed at site.
S&F ductile iron fittings for spigot socketed pipe like bends (any type, radius and angle), tapers any type (straight , bend, increasing, decreasing or double socket etc), Tee pieces, single branch, 'Y' junction, double branch, cross (all socket and spigot) collars, caps and plugs etc suitable for pipe line up to 400 mm bore complete all as specified and directed at site.
S & F of 100mm bore Cast Iron sluice valve both ends flanged PN-1.6 with iron wheel (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed
All as per item No- 40 above but of size 150mm bore complete all as specified and directed at site.
All as per item No- 40 above but of size 200mm bore complete all as specified and directed at site.
All as per item No- 40 above but of size 250mm bore complete all as specified and directed at site.
All as per item No- 40 above but of size 300mm bore complete all as specified and directed at site.
All as per item No- 40 above but of size 400mm bore complete all as specified and directed at site.
S & F of 200mm bore Cast Iron foot valve one end flanged PN-1.6 including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 complete all as specified and directed
M&L for brick work with old size sub class 'B' brick straight or curved on plan, exc. 6M mean radius in cement mortor 1:6 for repairing of valve pit/disturbed wall of well complete all as specified and directed
Supply and fix Cast iron work grade FG 150, un-machined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc. 5 Kg each complete all as specified and directed
Supply, installation, testing and commissioning outdoor type cubical LT automatic power factor correction (APFC) panel board for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade RAL-7035 provided with suitable gasket to make it dust/vermin proof & general construction mounted on angle iron frame with 'F' class insulator of non hygroscopic, non combustible track resistant material, along with frame made out with angle iron (L=1.6, H=0.5 and depth =0.45) mtr, 300 mm above ground level and 300 mm below ground, grouted in PCC 1:2:4 type B-2 comprising of the following :-
(a) OUTER SHELL : The outer shell shall be made out of 3.15 mm thick CRCA sheet & MS angle section 50x50x6mm frame with front and back openable, double door system lockable/openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air "U" type gasket shall be used to make the outer shell completely vermin proof . The bottom of the outer shell completely vermin proof. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The dimension of outer shall be adequate to accommodate inner shell described below giving 75 to 100mm space all around & shall be fabricated in such a way that the complete inner shell along with its control gears & accessories could be taken outside without disturbing outer shell. Provision of threaded stud at bottom and lifting lugs of suitable size at top to lift the panel, safety shall be made with degree of protection of outer shell shall be IP 56. Computer out self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided complete all as specified and directed at site.
(b) INNER SHELL : Inner shell be made out of 3.15 mm thick CRCA sheet duly compartmentalized for each control gear, front and back openable single door system lockable/openable by keys both sides having chromium plated 19,, dia fancy locks (02 Nos in each compartment) having louvers & air vent gasket for natural air flow, 'U" type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer/outgoing MCCBs and electrical grade aluminium for rated continuous current of 400 Amps for main bus bar with 65KA short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit with stand with heat shrinkable sleeves along with shrouds for joints & earth bus bar of aluminium 50x10Sqmm size (minimum) with short circuit rating of 30KA per sec duly colour coded shall be mounted on suitable size "F" class insulator FRP/SMC/DMC material at an interval not less than 500mm throughout the length of TPN bus bar. The cubical incomer MCCB as well as outgoing shall have aluminium TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than300mm long supported on suitable "F" class insulator made on non hygroscopic, noncombustible, track resistant, high strength FRP/SMC/DMC material having provision for termination of incomer and outgoing cables. All inter connections between the main bus bar as well as outgoing feeder shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeder & should be insulated with heat shrinkable PVC sleeves alongwith making connection with cable of size 70 Sqmm 3.5 core (approx length 24 RM) from APFC Panel to Main LT panel (Cable will not be measured and paid separately). All control wires shall be with 2.5 Sqmm multistranded copper conductors and shall be properly bunched, tied ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coating having thickness 2mm powder coated siemens grey natural RAL 7032 shade. An inner shell shall be of powder coated movable non ferrous chromium plated arm fitted on top side of inner shall be provided. The degree of protection for inner shall be IP-42 & carry the following controls :- Make : LEGRAND DMX 3/SIEMENS 3WL/L&T U POWER
Incomer:- (a) MCCB, 4 pole, 160 Amp, 50 Hz, 415 volts 16 KA, with thermal magnetic release alogwith adjustable magnetic protection for current setting Icu=Ics=100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-I and 60947-2 standard - 01 No. OUTGOING:- (a) MCCB, 4 pole, 125 Amp, 50 Hz, 415 volts 16 KA, with thermal magnetic release alogwith adjustable magnetic protection for current setting Icu=Ics=100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-I and 60947-2 standard - 01 No (b) MCB DP 6 Amp 10KA C curve type - 01 No.
(c) MCB SP 6 Amp 10 KA C curve type - 05 No (d) Power capacitor, 1X50 KVAR, 2X15 KVAR, 1X10 KVAR, 2X5 KVAR 6 stage MPP type heavy duty capacitor bank consisting of suitable no of switching sequences 3 phase 415 volts suitable for 10% Over voltage & 30% Over current having losses less than 0.5 w/KVAR within built discharge resistors. Make: Schneider/Legrand/Siemens. (e ) Contactors having current limiting resistors suitable for capacitor switching of variable KVAR correction of specification as approved. (Make: Schneider/Legrand/Siemens) (f) Microprocessor based intelligent APFC relay for controlling variable correction of KVAR. (Make: Schneider/Legrand/Siemens) (g ) Indication lamp RYB (LED type) with toggle switch- 05 set. (h) Push button for manual switching of capacitor. Make of MCCB/MCB : ABB, Siemens, L&T, Legrand, Schneider
Supply, installation, testing and commissioning of LT switch gear factory assembled 800 amps capacity 3 phase 440 volts 50 HZ AC design verified as per IS/IEC 61439-182 rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, indoor type floor mounted dust & vermin proof made out of 2 mm thick CRCA sheet of size (L=2.3, H=2.1 and depth =0.5) having seven tank treatment process for powder coating with thickness not less than 60 micron provided suitable gasket to make it dust proof / vermin proof duly compartmentalized for each gear front and back openable single door system, 19mm dia CP fancy locks with keys to accommodate incoming /outgoing MCBs, ACBs & including bus bar of rating not less than 1.5 times rated capacity of individual feeder & should be insulated with non combustible with colours coated heat shrink cable sleeves high strength FRP/SMC/DMC material as a distance not more than 300mm throughout the bus bar cable glands for all out going/in coming cables, and including connecting with existing incoming and outgoing cables of different sizes, mounted on angle iron frame with 'F' class insulator of non hygroscopic, non combustible track resistant material, alongwith frame made out with angle iron (L=2.3, H=0.75 and depth =0.5) mtr, 450 mm above ground level and 300 mm below ground, grouted in PCC 1:2:4 type B-2 complete all as specified & directed composing of following :- Make : LEGRAND DMX 3/SIEMENS 3WL/L&T U POWER
Incomer:- (a) MCCB, 4 pole, 400 Amp, 50 Hz, 415 volts 36 KA, with microprocessor release Icu 36KA & Ics 100% Icu with adjustable over load setting (minimum 70% to 100%) as per IEC-60947-1 and 60947-2 standard Qty - 01 No Outgoing:- (a) MCCB, 4 pole, 250 Amp, 50 Hz, 415 volts 36 KA, with microprocessor release Icu 36KA & Ics 100% Icu with adjustable over load setting (minimum 70% to 100%) as per IEC-60947-1 and 60947-2 standard Qty - 02 No. (b) MCCB, 4 pole, 160 Amp, 50 Hz, 415 volts 16 KA, with thermal magnetic release alogwith adjustable magnetic protection for current setting Icu=Ics=100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-I and 60947-2 standard - 01 No. (c ) MCB 10 Amp SP 'C' curve type - 01 No (d) Change over switch on load capacity 400 amps-01 No Make L&T Cat No C0440000000. (e) Fully automatic star delta starter 3 phase 415 volts induction motors including over load protection, under voltage relay, time delay relay, push button for start/stop, as recommended by manufacturer for 90KW/120 HP motor, length as required at site - 02 Nos Make - L&T. (f) Multi functional digital meter to show Amp/Volts HZ etc - 01 No Make of MCCB/MCB : ABB, Siemens, L&T, Legrand, Schneider
M&L Earthing complete for panel board with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 4.00 meter below normal ground level) with top edge of the earth plate not less than 3.25 mtrs below normal ground level connected to and included GI earth strip of size 25x4 mm thick soldered and riveted to earth plate , GI strip will be protected by using 50mm bore GI pipe (light grade) earth plate to test point including flat iron clamps 25x3mm including bolts, nuts, & washers and earth plate surrounded by 150mm thick alternate layers of charcoal or cock dust mixed with common salt , 20mm bore medium grade watering pipe complete , the earthing including PCC pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate ) cover of 50mm thick pre cast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate ) duly re-inforced with 8mm dia deformed bars & 100mm C/C both ways , funel with wire mesh etc all as specified and shown in electrical plate No: 3 of SSR 2009 part-1, earth lead connected to earthing to test point and testing of earthing on completion complete all as directed at site.
S&F in repair of Aviation obstruction light luminaries fittings having integral LED aviation light comprising of aluminium housing with polycorbonate enclosure at the top of OHT and making necessary electric connection with 2x1.5 Sqmm+1x1.5Sqmm as earth with copper conductor cable in PVC conduit and fixing arrangement of aviation lights complete all as specified and directed. Make Bajaj Model No BJAOL 1-75VA
S&F in repair of automatic electronic water level indicator with 5 stage, showing 0%, 25%, 50%, 75% & 100% (along with 5 Sensors and Sensor system with LED display) and making necessary electric connection with 2x1.5 Sqmm+1x1.5 Sqmm as earth with copper conductor cable and 1.5 Sqmm 6 core with proper arrangement for fixing to wall with the help of clamps screws etc for connection of water level indicator to sensor in PVC conduit complete all as specified and directed. Make : Aquamax or equivalent
C P Singh and Co
New Era Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .