| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.5 L+₹5.0 L (13.6%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹41.9 L+₹5.5 L (15.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹69,600
Closing Date
7 Apr 2023, 6:00 pmClosed
GE (UTILITIES) UDHAMPUR
GE (UTILITIES) UDHAMPUR, PO-GARHI
Spl repair to LT Network system, switch gears in Bldg No P95 to P98, P45 to49, P87, 89, 93,94 at Md Accn Bikram Enclave, addn,altn and improvement to Water Supply pipe, provn of 01xwater purified and 05xAC for various locations under GE (U)Udhampur.
2023_MES_585270_1
GE/U- 2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹69,600
Yes
16 May 2023
10 Mar 2023
10 Apr 2023
10 Mar 2023
7 Apr 2023
24 Mar 2023
Amount
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 160 amps, 4 pole,25/26 KA with adjustable thermal over load release 50 Hz, 415 volts grade - 1 No. (b) Bus bar electrolytic grade copper 300 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 125 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole - 01 set.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 100 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole, not less than 75 cm long mounted on insulators 01 set.
Outgoing:- MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) Cable glands for incoming LT cable 95 sqmm -01 Nos and out going cables 70 sqmm -01 Nos and 50 sqmm - 01 Nos and 25 sqmm -04 Nos is including rate quated by vendover.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB100 amps, 4 pole, 50Hz ,415 V with rupturing capacity 25/26 KA-01 No.
Outgoing:- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole - 01 set. Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) Cable glands for incoming LT cable 95 sqmm -01 Nos and out going cables 70 sqmm -01 Nos ,50 sqmm -01 Nos and 35 sqmm - 3 is including rate quated by vendover.
S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engr-in-Charge. Note:- The earthwork, PCC foundation, cooping, steel clamps, MS Cross arms & bracing of angle iron etc will be included deemed tobe rate coated for contractor.
S&F in replacement of LED Street light 60 watt made uppressure diecast aluminium housing with toughned glass and high power leds and secondary lens with IP 66 protection system of efficasy >110 LPW including 10 KV SPD including taking down old UNSV Street lights complete all as specified and directed by Engr-in-Charge.
GI pipe bracket Suitable size of light single swan neck shape suitable to fix on top of tubular pole complete with clamps, nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
S&F thermoplastic, polystyrene unbreakable junction box size 260 x 210 x 116 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including phase seperator between R, Y, B terminals and one MCB SP 6 amp 10 KA, all duly mounted on din cannel, cable glands for cable entry complete all as specified and directed by Engr- in-Charge.
M&L in replacement of PVC insulated multi stranded copper conductor PVC cable sheathed 2.5 sqmm 3 core and making connections of street light fittings and bollards lights complete all as specified and directed by Engr-in-Charge.
S&F in replacement of automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2 . The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge.
Supply and Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area as under including taking out old UNSV LT cables complete all as specified and directed by Engr-in-Charge. Note : Excavation, earthwork, Pipe for cable protection to be measured and paid for separately.
All as per serial item No 11.00 here-in-before but of size120 sqmm 3.5 core.
All as per serial item No 11.00 here-in-before but of size 95 sqmm 3.5 core.
All as per serial item No 11.00 here-in-before but of size 70 Sqmm 3.5 core.
All as per serial item No 11.00 here-in-before but of size 35 Sqmm 3.5 core.
All as per serial item No 11.00 here-in-before but of size 25 Sqmm 3.5 core.
All as per serial item No 11.00 here-in-before but of size16 Sqmm 4 core.
Supply & fixing or laying galvanised steel tubing light grade 80 mm dia (ISI marked) for protection of under ground cable on poles / walls under road crossing etc complete all as specified and directed by Engr-in-Charge.
M&L for boring of existing road/path for laying of GI pipe protection for UG cable including making good distrurbed area/surface complete all as specified and directed by Engr-in-Charge.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire complete all as specified and directed by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
Supply, install, 150 amp copper Bus bar with enclouser wall mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable/GI/CI pipe lines and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable/GI/CI pipe lines and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and installation AC in wall split unit air conditioner reversible type indoor and outdoor unit complete with cordiess remote control control unit and with built air ioniser and plasma filter for better indoor air quality of capacity 2 ton with standard accessories including MS frame work installation of outer with side making required hole in wall for passing of cooling pipes/cable and repair work tone demaged portion of wall in CM(1:4) complete all as specified and directed by Engr-in-Charge.
Supply and installation AC in wall split unit air conditioner reversible type indoor and outdoor unit complete with cordiess remote control control unit and with built air ioniser and plasma filter for better indoor air quality of capacity 1.5 ton with standard accessories including MS frame work installation of outer with side making required hole in wall for passing of cooling pipes/cable and repair work tone demaged portion of wall in CM(1:4) complete all as specified and directed by Engr-in-Charge.
Supply and fix voltage stabilizer for automatic operation. Single phase naturally air cooled indoor type and designed for input volatage 170V to 250V with output voltage 230V with accurecy of + 2.5% and capacity 5 KVA complete all as specified and directed by Engr-in-Charge.
Supply and fix metal clad single pole and natural enclosure 240 volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp suitable for Geyser/AC point complete incl taking down old unservicable complete all as specified and directed by Engr-in-Charge.
M&L sub main wiring with two runs of single core, PVC insulated, unsheathed, multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade and one run of 2.5 Sqmm PVC insulated earth continuity copper conductor cable drawn through and including suitable size of PVC concealed conduit with all necesary accessories such as bends, tees, junctions boxes, elbows etc complete with all in coming and outgoing cable connections complete all as specified and directed by Engr-in-Charge. Note:-Two runs of 4 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length.
Supply,fabrication and fixing MS joints like bends Tee, tapers, collars, elbow, tail piece (any type) caps, plugs up to 150 mm bore complete all as specified and directed by Engr-in-Charge.
Supply and Laying tubes medium grade galvanised 150mm bore plain end laid in trenches including all fittings such as bends (any type, radius or angle), tapers any type (straight,bend,increasing, descreasing or double socket etc) TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and plugs, MS flanges complete bends, TEE pieces, collars, elbow, tail piece etc complete all as specified and directed by Engr-in-Charge. Note:- (i) Flanges to be provided at every 6m length of plain end pipe or shorter length as directed by Engr-in-Charge. Flange will be welded to the GI pipe and gasket to be provided between two flanges and will be fixed with 08 Nos of nuts and bolts (M16 Type) at each jointing. Flanges will be of IS-6392 specifiecations. The cost of flanges, nuts & bolts, gaskets and connecting of flanges to pipeline by welding will be deemed to be included in the quoted item rate. (ii) All standard fittings such as bends (any type,radius or angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and plugs, MS flanges complete bends, TEE pieces, collars, elbow,tail piece etc jointing are deemed to be included in the quoted item rate. Make of fittings - ISI marked.
(iii) Jointing of pipe line will be done through flanging only and as directed by Engr-in-Charge. (iv) Excavation and earthwork will be measured and paid separately. (v) Any special fittings to be fabricated at site as per typical site condition will be measured and paid separately. (vi) Welding of flanges to be done by trained personnels at site and cost shall be deemed included in the quoted rate for normal flange joints for nominal length of pipes. However if the welding of pipes (other than normal flanged joint at nominal length) is required the same shall be measured and paid separately. (vii) Execution of work should be carried out without hampering the daily routine water supply.
Supply and Laying tubes medium grade galvanised with all fittings laid in trenches of size 100 mm bore including all fittings such as elbows, Tee, socket, union, reducers, etc complete all as specified and directed by Engr-in-Charge.
All as per serial item No 35.00 here-in-before but of size 50 mm bore.
All as per serial item No 35.00 here-in-before but of size 25 mm bore.
All as per serial item No 35.00 here-in-before but of size 20 mm bore.
S&F Gun metal gate valve of size 50 mm dia bore, ISI marked cast copper alloy screwed down high pressure with clutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and directed by Engr-in-Charge.
All as per serial item No 39.00 here-in-before but of size 25 mm dia bore.
All as per serial item No 39.00 here-in-before but of size 20 mm dia bore.
S&F cast iron sluice valve of size 150 mm dia (PN 1.6) ISI Marked with iron wheel head both end flanged, CI /steel spindle, non rising type complete with neoprene rubber gasket, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
All as per serial item No 42.00 here-in-before but of size 100 mm dia.
All as per serial item No 42.00 here-in-before but of size 80 mm dia.
M&L for cutting of existing GI/CI water main pipe line upto 300 mm bore in position for making branch connection (insertion of GI Tee) including excavation and earth work complete all as specified and directed by Engr-in-Charge. Note : GI fittings such as tee, elbows, collar, reducer etc joint and jointing material for fixing of cast iron fittings shall be measured and paid separately.
M&L for cutting of existing GI/CI water main pipe line upto 80 mm bore in position for making branch connection (insertion of GI Tee) including excavation and earth work complete all as specified and directed by Engr-in-Charge. Note : GI fittings such as tee, elbows, collar, reducer etc joint and jointing material for fixing of cast iron fittings shall be measured and paid separately.
M&L for cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing with pre mix bituminuos carpet complete all as specified and directed by Engr-in-Charge.
M&L for construction of Brick/stone masonary valve pit chamber of size 0.5 mtr x 0.5 mtr x 0.6 mtr internal dimention with 305 mm thick MS cover including 50x50x6 mm angle iron frame with inges embedded in coping with locking arrangement and painting the MS surfaces with two coat of redoxide primer. The chamber shall be of PCC, M-7.5(1:4:8), type D2 for foundation, brick work in cement mortar, coping with PCC, M-10 (1:3:6), type C1, 15 mm thick plastering in cement mortar 1:4 including necessary excavation, earth work and colour washing internally and externally surfaces complete all as specified and directed by Engr-in-Charge.
All as per serial item No 48.00 here-in-before but of size 1.2 mtr x 1.2mtr x1.20 mtr.
Supply, Installation, commisioning and testing of 150 LPH , Tech Industrial Reverse Osomosis, Ultra Violet, Ultrafiltration water purifier system as per latest technology consisting of fiber reinforced polymer vessel with treatment media like FBM, AFM, MGS, ACM CPM etc along with back wash system with multiport valves strainer feed water pump, high pressure pump, Reverse Osmosis elements Ultra voilet system with electric control panel and internal UPVC pipe and fittings gate valves, Non Return valves inlet and outlet connection fitted on well furnished and painted MS covered frame complete in all respect with Antiscalant Dosing system and container complete all as specified and directed by Engr-in-Charge.
Supply, Installation, commissioning of water cooler fully stainless steel, electric driven single phase having storage capacity 150 ltrs and nominal cooling capacity 150 ltrs per hour complete all as specified and directed by Engineer-in-Charge.
M&L point wiring with PVC insulated single core cable of stranded copper conductors of size 4 sqmm (Nominal area), 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 4 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, etc all as directed for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene water storage tank 1000 Ltrs capacity, ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections incl 20mm bore ball valve brass with polyethylene float and fly nut complete all as specified and directed by Engr-in-Charge.
M&L 100 mm thick cement concrete type C-2, 1:3:6, (M-10) (using 20mm graded aggregate) as in plinth protection finished fair & even without using extra cement complete all as specified and directed by Engr-in-Charge.
PREM NATH KHAJURIA AND SONS
K S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .