Complete overhauling, servicing and maintenance of Three (3) nos 125 ,250 and 500 KV oil filled transformer at BDPS.
2026_KMC_986744_1
BDPS/V/3TXR/2025
Open Tender
ELECTRICAL WORKS M/R
7 days
BDPS
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹6,000
26 Feb 2026
16 Jan 2026
27 Jan 2026
16 Jan 2026
24 Jan 2026
16 Jan 2026
Part-A + Part-B
Item Rate BoQ
BoQ_Ver3.0
testing
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
DISCONNECTION THE HV & LV LEAD FROM THE BUSHING END AT THE TRANSFORMER CABLE BOXES AND TO BE KEPT SAFE LOCATION
AFTER OPENING THE TOP COVER AND CONSERVATOR TANK AND THE CORE AND COIL TO BE LIFTED FROM THE TRANSFORMER TANK WITH THE HELP OF CHAIN AND PULLEY AND TO BE KEPT PROPER PLACE.
THOROUGH CLEANING AND REMOVING OF SLUDGE FORM THE TRANSFORMER TANK.
DEHYDRATION AND FILTRATION OF THE TRANSFORMER OIL AND TOPPING UP TO THE REQUISITE LEVEL INCLUDING ENFORCEMENT OF DI-ELECTRIC STRENGTH OF THE OIL TESTED UPTO THE VOLTAGE AS PER I.S SPECIFICATION AND TESTS WILL HAVE TO BE CARRIED OUT AS PER RULE.
ACIDITY TEST FOR THE TRANSFORMER OIL HAVE TO BE CARRIED OUT BY CERTIFIED TESTING AGENCY AND TEST RESULT WILL HAVE TO SUBMIT ACCORDINGLY.
NECESSARY FILLING OF SILICA GEL AND OVERHAULING OF CONSERVATOR TANK INCLUDING OIL GAUGE
REPLACEMENT OF BUSHING OIL SEAL, NUT AND BOLTS COPPER STUD OF BOTH HV & LV SIDES WITH NEW BUSHING OIL SEAL, NUT AND BOLTS, COPPER STUD AND REFITTING RESPECTIVE SIDE ACCORDINGLY
SUPPLY AND FILLINGS OF TRANSFORMER OIL
SUPPLY AND FIXING OF NEW GASKET OF TOP COVER, BUSHING, CONSERVATOR TANK ETC APPLY PROPER METHOD
PROPER CHECKING CALIBRATION OF O.T.I AND W.T.I BY PROVIDING EXPERIENCED PERSONNEL WITH SUPPLY AND FIXING OF DAMAGED OR MALFUNCTIONED COMPONENTS INCLUDING SUPPLY AND FIXING OF GASKET OF REQUIRED QUANTITY
RECONNECTION OF BOTH HV & LV SIDES AS PER STANDARD DIRECTION
NECESSARY RATIO AND HIGH PRESSURE TEST WITH THE APPLICATION OF 9 KV D.C VOLTAGE WILL HAVE TO BE CARRIED OUT AS PER RULE.
SPRAY PAINTING OF OUTSIDE SURFACE OF THE TRANSFORMER WITH ONE COAT RED OXIDE PRIMER AND TWO COAT OF SYNTHETIC ENAMEL AFTER PROPER CLEANING.
TERMINATION JOINT OF 300 SQ.MM, 3.5 CORE PVC INSULATED CABLE (M.V SIDE) AND 240 SQ.MM, 3 CORE XLPE CABLE (H.V SIDE) INCLUDING JOINTING MATERIALS AND CABLE END BOX .
Estimated amount
GRAND TOTAL [Rs.]
Please Enable Macros to View BoQ information
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
Tendernotice_2.pdf
PDF • 0.64 MB
BOQ_2409973.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid