Executive Engineer M and H Division Anantnag
office of the Executive Engineer M and H Division Anantnag
Complete Servicing of 3000 CFM/8.5 TR Air Handling Units (03 Numbers) at District Hospital Pulwama.
2025_PWDJK_275306_1
MHDA/TS/E-TENDER/01 OF 2025-26
Open Tender
Repair and Maintenance Works
Item Rate
15 days
District Hospital Pulwama
Refer NIT
8 documents required · 8 mandatory
₹200
Executive Engineer M and H Division Anantnag
₹8,000
24 May 2025
5 Apr 2025
6 May 2025
5 Apr 2025
5 May 2025
5 Apr 2025
Amount
Complete Servicing of 3000 CFM/8.5 TR Air Handling Units (03 Numbers) at District Hospital Pulwama.
Wet Servicing of 8.5 TR (DIAKIN) Outdoor Unit. (Each of EYE THEATRE, ORTHO THEATRE & GENERAL THEATRE)
Supply, Installation, Testing and Commissioning of 8.5 TR Outdoor Cooling Unit R22 Gas filled with Power Supply 415V, 50 Hz with 3 Pin Plug to replace the existing unit. (EYE THEATRE)
Filling of Refrigerant Gas (R 22) in 8.5 TR (DIAKIN) Outdoor Unit. (Each of EYE THEATRE, ORTHO THEATRE & GENERAL THEATRE)
Complete Rewinding of 3 Phase Induction Motor 5HP 2800rpm of AHU by way of Dismantling, extracting damaged coil from armatuer and cleaning of slots. Thereafter Complete Rewinding of the stator using superior quality copper wire of required no. of turns of the coil. The job includes proper insulatiion and varnishing of the coil. Reassembing of the Motor and refitting back in the AHU. Replacemment of damaged bearing as per sample.
Supply, Installation, Testing and Commissioning of 3 Phase Induction Motor 5HP 2800rpm
Supply, Installation, Testing ad Commissioning of Expansion Valve for proper Cooling
Providing and Fitting of Filters
Pre Filter (As per Sample in Each AHU)
Micro V Filter (As per Sample in Each AHU)
Hepa Filter (SS Type Filter shall be installed as per sample of each Theatre Room) (6 Nos. at EYE THEATRE, 6 Nos. at ORTHO THEATRE & 6 Nos. at GENERAL THEATRE)
Dryer Filter (As per Sample in Each AHU)
Supply, Installation, Testing and Commissioning of Water Type Heating Coil of size 711x762x 2 rows in each AHU
Supply, Installation, Testing ad Commissioning of 3 Pole, 32A Contactor Of reputed make with a breaking capacity of 300A.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .