Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC BANK COLONY MATHASAHI PS TOWN PO DIST BALASORE | BALASORE | BALASORE | ODISHA | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹46.7 L+₹2.0 L (4.48%)Rejected-Finance BHOISAHI NEAR CENTRAL SCHOOL INDRA GANDHI MARG BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹48.4 L+₹3.7 L (8.36%)Rejected-Finance 28 GREEN PARK PO BELGHARIA KOLKATA WEST BENGAL 700 056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹48.6 L+₹3.9 L (8.82%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹49.7 L+₹5.1 L (11.3%)Rejected-Finance 10 8A BEJOYGARH KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L5 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | M/SNeelachal Enterprises L1 | ARIN AND COMPANY L2 | J B NATH AND SON L3 | M/S RAJENDRA PRASAD L6 | M/s D.K Mukherjee & Co L5 | RANA ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for two coats of white wash on walls including preparation of old decorated surfaces complete all as specified and directed. | 360 | Sqm | 18 ₹6,480 Lowest | 20 ₹7,200 | 22 ₹7,920 | 37 ₹13,320 | 25 ₹9,000 | 25 ₹9,000 |
| 2.00 | M&L for two coats of white wash on ceiling surfaces including preparation of old decorated surfaces complete all as specified and directed. | 160 | Sqm | 22 ₹3,520 Lowest | 22 ₹3,520 Lowest | 26 ₹4,160 | 59 ₹9,440 | 27 ₹4,320 | 30 ₹4,800 |
| 3.00 | M&L for preparation of old decorated surface of walls and applying one coat of acrylic distemper complete all as specified and directed. | 80 | Sqm | 45 ₹3,600 Lowest | 45 ₹3,600 Lowest | 55 ₹4,400 | 74 ₹5,920 | 51 ₹4,080 | 50 ₹4,000 |
| 4.00 | M&L for preparation of old surface of wall surfaces and applying two coats of acrylic distemper including a coat of primer with filling of putty for cracks, hole etc complete all as specified and directed. | 2,100 | Sqm | 90 ₹1,89,000 Lowest | 109 ₹2,28,900 | 102 ₹2,14,200 | 110 ₹2,31,000 | 110 ₹2,31,000 | 100 ₹2,10,000 |
| 5.00 | All as per serial item No 4 here in before but on ceiling surfaces. | 600 | Sqm | 92 ₹55,200 Lowest | 115 ₹69,000 | 105 ₹63,000 | 130 ₹78,000 | 110 ₹66,000 | 100 ₹60,000 |
| 6.00 | M&L for complete removal of existing treatment and finishing walls with acrylic smooth exterior wheather coat paint of required shade (Two or more coat applied @ 1.43 lit/10sqm over and including priming coat of exterior primer applied @ 0.90kg/10 sqm complete all as specified and as directed. | 14,277 | Sqm | 144.5 ₹20,63,026.5 Lowest | 146 ₹20,84,442 | 155 ₹22,12,935 | 160 ₹22,84,320 | 160 ₹22,84,320 | 155 ₹22,12,935 |
| 7.00 | M&L for preparation of old painted surface of wood and wood based surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 650 | Sqm | 60 ₹39,000 Lowest | 71 ₹46,150 | 72 ₹46,800 | 92 ₹59,800 | 75 ₹48,750 | 70 ₹45,500 |
| 8.00 | M&L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 250 | Sqm | 70 ₹17,500 Lowest | 76 ₹19,000 | 85 ₹21,250 | 101 ₹25,250 | 85 ₹21,250 | 80 ₹20,000 |
| 9.00 | Taking down cement plaster on brick or stone walls etc including raking out joints,hacking for key, scrubbing down with water etc complete all as specified and as directed. | 290 | Sqm | 80 ₹23,200 Lowest | 97 ₹28,130 | 102 ₹29,580 | 112 ₹32,480 | 110 ₹31,900 | 100 ₹29,000 |
| 10.00 | M&L 10mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surfaces even and smooth without using extra cement on walls complete all as specified and as directed. | 40 | Sqm | 220 ₹8,800 Lowest | 248 ₹9,920 | 260 ₹10,400 | 355 ₹14,200 | 265 ₹10,600 | 250 ₹10,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
2 Sept 2025, 6:00 pmClosed
Garrison Engineer
GE (I) R and D Chandipur, Post-Chandipur, PIN-756025
PERIODICAL SERVICES TO CERTAIN BUILDINGS AND GARDEN BARRICADING WALL AT PXE ITR AND OT ROAD COLONY, SITE N NILGIRI AT BALASORE AND NILGIRI AND REPAIR REPLACEMENT OF CERTAIN SUB MAIN AND POINT WIRING LED LIGHT FITTINGS, SUB MAIN WIRING
2025_MES_710431_2
8187/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) R AND D CHANDIPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) R AND D CHANDIPUR
₹90,000
Yes
22 Sept 2025
12 Aug 2025
3 Sept 2025
12 Aug 2025
2 Sept 2025
26 Aug 2025
Amount
M&L for two coats of white wash on walls including preparation of old decorated surfaces complete all as specified and directed.
M&L for two coats of white wash on ceiling surfaces including preparation of old decorated surfaces complete all as specified and directed.
M&L for preparation of old decorated surface of walls and applying one coat of acrylic distemper complete all as specified and directed.
M&L for preparation of old surface of wall surfaces and applying two coats of acrylic distemper including a coat of primer with filling of putty for cracks, hole etc complete all as specified and directed.
All as per serial item No 4 here in before but on ceiling surfaces.
M&L for complete removal of existing treatment and finishing walls with acrylic smooth exterior wheather coat paint of required shade (Two or more coat applied @ 1.43 lit/10sqm over and including priming coat of exterior primer applied @ 0.90kg/10 sqm complete all as specified and as directed.
M&L for preparation of old painted surface of wood and wood based surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints,hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L 10mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surfaces even and smooth without using extra cement on walls complete all as specified and as directed.
M&L 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even and fair all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on ceiling/RCC finished even and smooth without using extra cement etc complete all as specified and as directed.
M&L for preparing newly plastered surface of ceiling and applying three coats of white wash all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and finishing wall with acrylic smooth exterior wheather coat paint of required shade (Two or more cot applied @ 1.67 lit/10sqm over and including priming coat of exteriior primer applied @ 2.20kg/10 sqm. all as specified and as directed.
M&L for two coats of oil bound distemper over a coat of primer in newly plastered surfaces of walls of any description including 1.00 mm wall care putty incl preparation of surfaces all as specified and as directed.
S&F 3mm thick ACP sheet at base with self adhesive colour vinayl tape denoting bldg No of any size and shape as approved by GE, including fixing on wall/RCC surface by drilling hole at any height with SS screws complete all as specified and as directed.
Taking down carefully copper/aluminum point wiring (Light fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floor, etc complete all as specified and as directed.
M&L Point wiring for one light/fan/bell point controlled by one switch using FRLSH grade PVC insulated, unsheathed, stranded copper conductor three run of size 1.5 Sqmm for phase neutral and earth continuity wire to be drawn in and including non metallic rigid PVC conduit concealed in wall including MS sheet metal switch / terminal box 1.2 mm thick upto (200x300)mm size box and beyond that not less than 1.63mm thick with Hylam sheet cover 3.00mm thick including cutting and chassing the wall as per site requirement and making good disturbed surface of walls complete all as specified and directed.
All as per serial item No-18 above but for One 5 Amps switch socket combination on independent board
All as per serial item No-18 above but for One 5 Amp Socket on same board
All as per serial item No-18 above but for 15/16 Amps switch socket out let independent point by using three run 4.0 Sqmm FRLSH grade, PVC insulated, stranded copper conductor complete all as specified and directed.
All as per serial item No-18 above but for 15/16 Amps switch socket out let independent point by using three run 2.5 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor complete all as specified and directed.
Supply and fixing including connection of call bell AC 230 Volt single pole complete all as specified and directed.
Supply and fixing including connection of bell push switch,flush type 5 Amps, 230 volts complete all as specified and directed.
M&L Point wiring for one light/fan/Bell/Holder point controlled by one switch using FRLSH grade PVC insulated, unsheathed, stranded copper conductor of three run of 1.5 Sqmm for phase neutral and earthing to be drawn in and including PVC casing capping of suitable size incuding MS sheet metal switch / terminal box 1.2 mm thick upto (200x300)mm size box and beyond that not less than 1.63mm thick with Hylam sheet cover 3.00mm thick and making good disturbed surface to walls complete all as specified and directed.
All as per serial item No 25 above but for 5 Amps switch socket combination on independent board.
All as per serial item No 25 above but for one 5 Amps switch socket combination on same board.
All as per serial item No 25 above but for 15/16 Amps switch socket out let independent point by using 3 runs of 4.0 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor complete all as specified and directed.
All as per serial item No 25 above but for 15/16 Amps switch socket out let independent point by using 3 runs of 2.5 Sqmm FRLSH grade, PVC insulated, stranded copper, conductor complete all as specified and directed.
S&F in repair Including connection of switch piano, flush button, type single pole one way 5 Amps complete all as specified and directed.
S&F including connection of switch socket combination 5 Amps 2 in 1 flush type complete all as specified and directed.
S&F including connection of switch socket combination 5 in 1, 3 pin, 5 and 16 Amps flush type complete all as specified and directed.
S&F ceiling rose polycarbonate three terminals complete all as specified and directed.
S&F electronic fan regulator, stepped type 120/280V complete all as specified and directed.
S&F of Lamp holder, PVC/Polycarbonate type with back plate complete all as specified and directed.
M&L for point wiring for light point/ fan point/ exhaust fan point/ call bell point with three run 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, included fixing of modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required for concealed wiring, including all necessary wall cutting and making good disturbed surface complete all as specified and directed.
S&F of Modular switch 1 way 6A, 1 module
S&F of Modular switch 1 way 16A, 1 module
S&F of Modular Socket 6A/16A - 2/3 pin combined 2 module
S&F of Modular Fan step regulator, 120W - 2 module
S&F of MODULAR COVER PLATE WITH FRAME 3 module
S&F of MODULAR COVER PLATE WITH FRAME 4 module
S&F of MODULAR COVER PLATE WITH FRAME 8/12 module
S&F of Modular Metal flush box 3 module module
S&F of Modular Metal flush box 4 module module
S&F of Modular Metal flush box 8/12 module module
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as specified and directed.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC conduit 25mm dia. (Note: Three runs of 4 Sqmm copper wire shall be measured as one unit)
All as per serial item No-48 but in PVC Casing and Caping
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 2.5 Sqmm to be drawn in and including PVC conduit 25mm dia. (Note: Three runs of 2.5 Sqmm copper wire shall be measured as one unit)
All as per serial item No-50 but in PVC Casing and Caping
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, stranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25mm dia. (Note: Three runs of 6 Sqmm copper wire shall be measured as one unit)
All as per serial item No-52 but in PVC Casing and Caping
All as per item No. 48 above, but using 4 runs of 6 Sqmm and two run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and inclusing PVC conduit medium grade of size 32 mm dia (Note : Four runs of 6 Sqmm copper wire with two run of 6 Sqmm copper wire shall be measured as one unit.)
All as per serial item No-54 but in PVC Casing and Caping
All as per item No. 48 above, but using four runs of 10 Sqmm and two run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and inclusing PVC conduit medium grade of size 32 mm dia (Note : Four runs of 10 Sqmm copper wire with two run of 10 Sqmm copper wire shall be measured as one unit.)
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc for concealed water tubing or concealed conduit wiring,Fair cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc. including rubbed finish and waste complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and fix in repair vertical TPN MCCB DB 8 way with 200 Amps rated busbar, double door type including provision for fixing MCCB 4 pole 100 Amps, 25 KA complete and making disturbed surafce good to match the existing surface complete all as specified and directed.
S&F in repair MCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbed surfaces complete all as specified and directed.
All as per serial Item No. 60 here-in-before but of SPN 8 way, 240Volts double door complete all as specified and directed.
All as per serial item No. 60 here-in-before but of SPN 12 way, 240Volts double door complete all as specified and directed.
S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps complete all as specified and directed.
All as per serial item No. 63 above but of capacity 63 Amps, 4 Pole, 16 KA complete all as specified and directed.
S&F in repair MCB, SPN 32 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed.
S&F in repair MCB, TPN, 415 V, 50Hz, 10kA, 'C' series, 63 Amps series complete all as specified and directed.
S&F in repair MCB, TP, 415 V, 50Hz, 10kA, 'C' series, 25 to 63 Amps series complete all as specified and directed.
S&F in repair MCB, SP, 6 to 32 Amps, 240 volt, 'B' Series, 10 kA complete all as specified and directed.
S&F in repair MCB, SP, 40 Amps, 240 volt, 'B' Series, 10 kA complete all as specified and directed.
Supply and fix in repair LED batten fitting 4' long of capacity 20 Watt with diffuser complete in channel thermally conductive meterial including PVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete all as specified and directed.
All as per serial item Sl No. 70 above here-in-before but 10 Watt, 2' all as specified and directed.
Supply and fix in repair retrofit LED tube rod only of capacity 20 Watt 4' long complete all as specified and directed.
Supply & fix LED luminaire 600 mm x 600mm 35/36 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed by engrs in charge.
S&F 40 mm bore tubes, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors GI Pipe Medium Grade including necessery clamp arrangement for fan hanging, use protection pope to earthing, wire etc complete all as specifed and directed.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item).
S&F in repair Earthing conductor with GI strip of size (25 x 4) mm complete all as specified and directed.
Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire 1.5m long, including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts, flexible copper wire and rewinding shall be measured and paid separately under relevant items of these schedule).
All as per item No. 77 here-in-before but for Exhaust fans of any size and make.
M&L rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as specified and directed.
All as per item No.79 here-in-before but for exhaust fans of 300/380mm sweep of complete all as specified and directed.
Supply only Ball bearing of suitable size for any type/make of ceiling fan, Exhaust Fan, Wall Fan complete all as specified and directed.
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan complete all as specified and directed.
Supply only capacitor 220 volts,4 mfd suitable for ceiling fan complete all as specified and directed.
Supply only in replacement of existing damage motor of ceiling fan due to bend or wear tear in shaft, damage of armeture laminated sheet or seized of bearing with new white coloured cu wounded motor suitable for 1200mm ceiling fan with necessery one year warranty in all respect including hanging rod complete all as specified and directed.
Supply only in replacement of existing damage ceiling fan blade due to bend, wear and tear with new one 1200 mm long set of three white in colour complete all as specified and directed.
S&F included concealed into a brick wall to flush metal GI Box 1.2 mm thick of suitable size for fixing of 5/15 A Switch Socket combination included necessery hylum sheet with cutting slot for switch, socket, regulator with S S Screw and making good disturbed surface of walls complete all as specified and directed.
S&F in repair 16A, 3 pin plug top complete all as specified and as directed.
S&F included concealed into a brick wall to flush metal GI Box 1.2 mm thick of suitable size for fixing of switch, regulator, socket & Switch Socket combination as an switch board included necessery hylum sheet with cutting slot for switch, socket, regulator and S S Screw and making good disturbed surface of walls complete all as specified and directed.
S&F in repair hanging clamp for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete all as specified and directed.
S&F in repair LED Bldg security light fitting 20 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories complete all as specified and directed.
S&F single phase two wire energy meters 5-30 Amp 230 Volt accuracy class 1.0 with box complete incl taking down old if exist all as specified and directed
S&F in repair to damaged body/ tank of geyser of capacity 25 liters capacity complete all as specified and as directed.
Taking down geysers of 25/50 litres capacity and refixing the same in position, reconnection of existing inlet/outlet pipe lines and power connection after necessay repair by takingout defective parts/ components for replacement with new one including testing complete all as specified and as directed. Note : New parts/components shall be measured and paid separately under relevant items.
M&L for repair to 50 Ltrs capacity geyser inner shells made out of copper/steel with brazing soldering welding including outer shell/ body repair & reassembling the same complete all as specified and as directed.
M&L for repair to 25 Ltrs capacity geyser inner shells made out of copper/steel with brazing soldering welding & including outer shell/ body repair reassembling the same complete all as specified and as directed.
S&F in repairs heating element, 1.5/2KW capapcity of existing type for geyser complete all as specified and as directed.
S&F in repairs thermostat, bi-metallic strip type of working range 32 degree to 90 degree celcius as per existing at the site complete all as specified and as directed.
S&F in repairs pressure release valve suitable for outlet pipe 15mm bore complete all as specified and as directed.
S&F in repairs apparatus plate suitable for 25/ 50 ltrs capacity geyser complete all as specified and as directed.
S&F in repairs inlet and outlet connection pipe reiforced with 304 grade stainless steel (Pack of 2 Nos and each 650 mm long) with check nut and washer suitable for existing geyser of capacity 25/50 litr complete all as specified and as directed.
ARIN AND COMPANY (BID ID -3410761)
J B NATH AND SON (BID ID -3413926)
RANA ENTERPRISES (BID ID -3413817)
M/s D.K Mukherjee & Co (BID ID -3407588)
M/S RAJENDRA PRASAD (BID ID -3411808)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .