Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-Finance | L1 | Accepted-Finance L1 Bidder | |
| 2 | L2₹26.1 L+₹23,970 (0.93%)Rejected-Finance | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹26.4 L+₹50,665 (1.96%)Rejected-Finance | L3 | Rejected-Finance L3 Bidder |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
2 May 2022, 6:00 pmClosed
SE OandMC IV DTPS
Office of SE O and MC IV DTPS
Breakdown Maintenance and Overhauling of HT Motors and HT/LT Transformers and Associated system installed in EMD-I DTPS ANPARA
2022_RVUNL_685898_1
T-03/EMD-I/DTPP/ANPARA/2022-23
Open Tender
Electrical Works
Fixed-rate
365 days
DTPS ANPARA
As Per Tender Documents
2 documents required · 2 mandatory
₹1,180
Dy CAO CFA AND BO DTPS
₹32,000
Yes
29 Aug 2022
8 Apr 2022
3 May 2022
8 Apr 2022
2 May 2022
8 Apr 2022
8 Apr 2022 - 2 May 2022
Amount
Shifting of HT motors from foundation to workshop/place of work and from place of work/workshop to foundation (To & Fro)
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Exciter of ID Fan motor
Decoupling/ Coupling of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Replacement / Inspection of drive end bearings HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 550 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Replacement / Inspection of non drive end bearings HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Replacement/ Inspection of both drive end & non drive end bearings HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Dismantling of Stator & rotor for inspection/ repair of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Exciter of ID Fan motor
Assembling of Stator & rotor for inspection/ repair of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW(except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Exciter of ID Fan motor
Bearing revisioning of Drive end side of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Bearing revisioning of Non Drive end side of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Reparing and replacement of internal leads of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW (except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Cleaning and reparing of water coolers of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
11 KV MBFP motors of 10000 KW
Re-visioning/ repairing and adujstment of fan cover/cooling fan/cable box of motor of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW (except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Complete Overhauling of HT motors
2.3 KV synchronous motors of ID Fan, 3900 KW
3.3 KV motors from 190 KW upto 650 KW (except mill motor)
3.3 KV Bowl mill motors of 525 KW
3.3 KV CEP motors of 900 KW
3.3 KV FD Fan motors of 1350 KW
11 KV CW motors of 2400 KW
11 KV PA motors of 3250 KW
11 KV MBFP motors of 10000 KW
Alignment of HT motors
3.3 KV horizontal motors from 190 KW upto 650 KW(except mill motor)
11 KV CW motors of 2400 KW
Setting of air gap between rotor and stator
2.3 KV synchronous motors of ID Fan, 3900 KW
11 KV MBFP motors of 10000 KW
Matching of magnetic and mechanical center of motors
2.3 KV synchronous motors of ID Fan, 3900 KW
11 KV MBFP motors of 10000 KW
Replacement of bearing of LT wheel of EOT crane
Overhauling of gearbox of LT/ Cross travel/ Hoist of EOT crane
Replacement of gasket of top cover, inspection cover of Transformer
LT transformers up to 2 MVA
HT transformers: up to 6.3MVA
Replacement of gaskets of radiator bank and other connecting pipeline, valves etc. for arresting leakage.
LT transformers up to 2 MVA
HT transformers: up to 6.3MVA
HT Transformers: UT and UAT
Replacement of HT or LT or Neutral Bushing or Gaskets.
LT transformers up to 2 MVA
HT transformers: up to 6.3MVA
HT Transformers: UT and UAT
Replacement of HT or LT turret gaskets of transformers.
LT transformers: up to 2 MVA
HT transformers: up to 6.3 MVA
Disconnection of UT transformer from HT side
Centrifuging of Transformer Oil of HT/ LT transformer/ storage tank.
Transportation of Oil filled drums or Oil Tanks.
75 Drums (approx. 15 KL) of 209 L
25 Drums (approx. 05 KL) of 209 L
10 Drums (approx. 02 KL) of 209 L
Oil storage tank to site at DTPS from ATPS/BTPS/DTPS site
Overhauling of Tap Changer of UT.
Breakdown Maintenance of HVR Transformers
Erection and Commissioning of Transformers
HVR / LT Transformers up to 2 MVA.
HT Transformers up to 6.3 MVA.
Dry Type Transformer 2 MVA.
Breakdown work of Isolated Phase Bus Duct.
Replacement of Rubber Bellow Expansion of IPBD.
Replacement of Phase side seal Off Bushing of IPBD at LV side.
Preventive maintenance work of all CT’s and PT’s of IPBD.
Testing and Tightening of IPBD CT connections and CT MB.
Testing and tightening of PT of IPBD and their box up.
Preventive Maintenance work on SPBD of transformer.
Breakdown work of SPBD of transformer.
Erection or dismantling of scaffolding of IPBD/ SPBD.
M/S MADHU CONSTRUCTION
M/S SHAKTIREFRIGERATION WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .