Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.2 LAccepted-AOC | L1 | Accepted-AOC Alloted as L1 Bidder | |
| 2 | L1₹91.2 LRejected-AOC | L1 | Rejected-AOC work not alloted | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically not Qualified |
Tender Value
₹96 L
EMD Value
₹1.9 L
Closing Date
20 Feb 2024, 2:00 pmClosed
EE, PHE, Dhemaji Division
Office of the EE, PHE, Dhemaji Division
Renovation/ Upgradation of old existing Rupnagar Borgaon PWSS
2024_PHED_36183_4
PHEE/Dhj/TB-04/2023-24 /11453-57 Dated 09/02/24
Open Tender
Civil Works
Works
180 days
Dhemaji
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,900
₹1.9 L
Yes
15 Jun 2024
12 Feb 2024
21 Feb 2024
12 Feb 2024
20 Feb 2024
14 Feb 2024
12 Feb 2024 - 20 Feb 2024
Amount
1) Installation, Testing and commissioning of DTW at Maj Kekuri Miri PWSS under different divisions of the Stste. i) Rotary Drill/Reverse Rotary Drill : Providing installation and commissioning of 150 mm dia deep tube well by Rotary Rig within the jurisdiction of different phe divisions including preparation of site for placing of drilling rig, transportation of rig and ancillary equipments and drilling the DTW including extraction of drill pipes etc, lowering fitting fixing 150mm diameter UPVC pipe assembly comprising of strainer, pipes and cone in potable water bearing strata, washing the bore well etc. , supplying necessary jointing materials, developing the DTW with air compressor Make- Kirloskar / Cumins for a period of 24 hours and supplying and packing pea gravel of size 1/8" to 3/8" around the periphery of casing including screening washing etc. all complete to the satisfaction of the deptt.
Supplying, installation, testing and commissioning of water lubricated Submersible Pump Set 3-Phase (for 5HP/ 7.5HP) / Single phase (for 1 HP / 2HP / 3 HP) pump with bronze impeller of suitable diameter all complete. The pump set should be coupled with wet type submersible electric motor drive of adequate power suitable for operation at 230V/ 415 V, 50 Hz input power including supply of steel cable rope, G.I. column pipe, suction strainer, Sluice Valve, Non-Return valve, sockets, bends, elbows etc. & GI delivery piping above ground up to sluice valve above ground level, electrical cable of adequate cross section, clips electrical switch gear (starter) etc., Electric Control Panel Board made of MS Sheet duly painted with Anti-corrosive paints complete fitted with all electrical accessories i.e. Off-On Switch, Voltmeter, Ameter, Indicator light etc., bright Annealed Electrolytic Bar Copper Conducted PVC insulated sheathed round flexible 3-core Cable of the Motor Manufactured conforming to IS:694/1990 all complete as specified and directed by the Department with One year warranty from the date of commissioning and satisfactory testing against any manufacturing defect. [If any such defect is found during the year from the date of installation and satisfactory testing, supplier will have to rectify the defect at their cost and risk & if necessary replace the pump set.] Test Certificate of Pump, Motor, Starter, Panel Board, etc. from the manufacturer shall have to be submitted: 3 Phase 3 HP pump, head considering all losses(m): 32
Supplying, installation, fitting & fixing, testing and commissioning of Electric driven 3-phase (for 5HP/ 7.5HP/10HP/12.5HP) / Single phase (for 1 HP / 2HP / 3 HP pump) Centrifugal pump set of approved make with bronze impeller of suitable diameter with G.I. suction pipe, suction strainer, non-return valve, delivery piping up to sluice valve all complete. The pump set should be coupled with electric motor drive of adequate power suitable for operation at 230V / 415 V, 50 Hz input power with DOL Starter /Star delta Starter including Electric Control panel board enclosure made of MS Sheet duly painted with Anticorrosive paints complete, fitted with all electrical accessories i.e. Off-On Switch, Voltmeter, Ammeter, Indicator light etc., Complete wiring from Panel Board to Main Line including supply of Aluminium Armoured Cable of adequate cross section, Earthing wire and all necessary materials for the same including cost of CC pump foundation with base plate complete and other accessories and labour charge for installation of the pump etc. all complete as specified and directed by the Department with One year warranty from the date of commissioning and satisfactory testing against any manufacturing defect. [If any such defect is found during the year from the date of installation and satisfactory testing, supplier will have to rectify the defect at their cost and risk & if necessary replace the pump set.] Test Certificate of Pump, Motor, Starter, Panel Board, etc. from the manufacturer shall have to be submitted: 5 HP pump 3 phase
(A) Supplying, laying , fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (pt-I) 2004 (with up to date Amendment) including GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering including bailing out water where necessary all complete and also necessary testing and commissioning as per direction of the department. 80 mm dia GI
(A) Supplying, laying , fitting & fixing GI (Medium Class) Pipe conforming to IS-1239 (pt-I) 2004 (with up to date Amendment) including GI specials and jointing material, cutting of pipe materials and necessary earthwork in trenching and refilling of earth and restore to its original condition including dressing, dewatering incuding bailing out water where necessary all complete and also necessary testings and commissioning as per direction of the department. 100 mm dia GI
80 mm dia GI
Construction of gravity type Rapid Sand Filter of Size 4m2/6m2 including the following item of works: (i) Earthwork for excavation (ii) 150 mm thick PCC (prop. 1:3:6) (iii) Brick soling (iv) Formwork of ordinary timber planking including centering, shuttering, propping, etc. (v) PCC/RCC works (M25 grade in foundation & superstructure) (v) 250 mm brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed. (vi) 15 mm thick Cement plaster in single coat on rough and fair side (prop. 1:4) (vii) Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make (two coats) (viii) Supplying, fitting and fixing including labour charge of under drainage with 150 mm dia PVC manifold and 63 mm dia PVC laterals and interconnection of the filter unit including necessary GI fittings. (ix) supplying and charging of filter media considering all materials for the filter bed constructed as per the specification provided by the deptt. The specification of the sand and gravel is as below: (a) Sand should be hard, resistant quartz, free from clay, fine particles, soft grains, organic matter and dirt. Effective size of sand (d10) has to be within the range from 0.45 mm to 0.7 mm and uniformity coefficient (d60/d10) within 1.3 to 1.7. The effective depth of sand bed has to be 0.60 m. (b) Gravel has to be hard preferably rounded stone and not crushed stone, with average specific gravity not less than 2.5 and shall be free from clay, loam and organic impuritues. Size range has to be from 2mm to 65mm properly graded as directed by the deptt. The effective depth of gravel bed has to be 0.50 m. 4 sq.m filter bed-For Surface Source
Construction of sedimentation tanks of following capacity with length to breath ratio 1:3, including necessary earthwork, 100 mm thick PCC in prop. 1:3:6 with coarse aggregate of sizes 13mm to 32mm over flat brick soling including dewatering and curing, construction of all RCC members, brick works, 20 mm thick Plastering, water proofing weather coat exterior painting & Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. reflex valve, supplying bolts and nuts, 3 mm thick rubber insertion sheet etc of CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING (100mm,150mm & 200mm dia) as per detailed drawings & specifications as directed by the engineer-in-charge. - 60000 L (Size : 7.50mx2.50mx3.40m)
Supplying,fitting,fixing of internal connection between TP & UGR including labour charge and materials which includes the following jobs: a. Earth work in excavation in foundation trenches (of size 1 x 1 x 18.00 m x 0.60m x 0.90m=9.72 Cu.M) including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc as directed by the Deptt. b. Supplying of UPVC perforated laterals of 50mm dia and 60 cm long by making hole of 5mm dia at a spacing of 8 cm centre to centre in two lines at 60 degree with the centre of the pipe and threading at both ends and supplying, fitting and fixing 40mm dia U.P.V.C. threaded End Plug at one end, the other end to be fitted with a UPVC threaded nipple of 75 mm long properly embedded in RCC cover slab all complete. c. Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:3/2:3 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. d. Supplying and placing of filter sand of hard and resistant quartz, uniform size and shape free from dust, clay, soft grains, dirt and any other foreign materials includind inorganic salt and organic substance, washed and screened. Having uniformity coefficient between 1.3 to 1.7, effective size between 0.45 to 0.70mm, ignition loss not exceeding 0.7% by weight, soluble fraction in Hydrochloric acid not exceeding by 5% by weight, silica content not less than 90%, specific gravity between 2.55 to 2.65, wearing loss less than 3% as per IS: 1419 (Part-I):1977 all complete as directed. e. Supplying and placing of filter gravel of uniform size and shape without flacky & elongated shape, free from dust , clay, soft grains, dirt and other foreign materials, washed and screened to different sizes as per IS 8419 (Part-I) : 1977 all complete as directed.
Construction of 16M MS staging ESR with GRP tanks (Conforming to I:S: 14399 (part 1&2) 1996 & IS 4249 : 1967) installed over it including & providing, fitting, fixing the base sheets as per the design and testing for leakage, inserting inlet , outlet, overflow, vent, wash pipe, aviation light, lightening arrestor etc all complete as per direction of the engineer-incharge. 60000 liters,8 ton/sq.m
Extra cost for providing piles in case of pile foundation (considering pile capacity of 10 Ton to 15 Ton per pile …....all complete as directed by the department. 60000 Litres 8 ton/sq.m
Extra Cost for providing pile cap in place of isolated footing ..all complete as directed by the department. 60000 Litres Capacity 1x1 = 1 Job
Collection from the field and testing in the laboratory of undisturbed soil samples for sub- soil investigation (as per relevant I.S code) by open drive sampler (100mm dia boring) through clayey soil layer/ sandy soil layer/ sandy clay/ sandy silt layer/ clayey silt layer, conduction standard penetration test (SPT) and collection of SPT sampler, observation of ground water table, spot level survey to the bore location and carrying out R.L. from nearest B.M., laboratory test (particle size analysis, hydrometer test, determination of liquid limit, plastic limit, bulk density, moisture content, specific gravity,conducting triaxal test, direct shear test, unconfined compression test, consolidation test including preparation of sub-soil investigation report complete with necessary printing and binding (minimum 5 copies)
Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes-PE 100) confirming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine.(50 mm & above fusion jointed & below 50mm mechanical jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code. (a) 140 mm dia HDPE PN 6
(b) 110 mm dia HDPE PN 6
( c) 90 mm dia HDPE PN 6
(d) 75 mm dia HDPE PN 6
(e) 63 mm dia HDPE PN 6
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Labour charge for making bore hole horizontally across road or embankment for crossing distribution pipe line including fitting fixing of G.I. casing pipe of required dia including the cost of pipe all complete as directed by the deptt.
Construction of RCC Supporting pillar to be used as support of pipeline for crossing of culverts etc. of 0.25x0.25m size and height varying from 0.5m to 1.5m above GL, including necessary earthwork, 75 mm thick PCC in prop. 1:3:6 over flat brick soling, foundation of size 0.80 x 0.80 m x 0.125m(depth) with 8mm dia reinforcemnt @ 150mm c/c both sides, and 12mm dia main reinforcement for the pillar with 8mm dia single legged stirrup @150mm c/c, 15mm thick plaster including shuthering / shoring and all complete as per direction of the deptt. Approved good for construction drawing will be issued by the deptt. Supporting pillar of height 0.50m above GL
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.( width to be considered 60 cm)
Supply with fitting & fixing 60mm dia 1830 mm height integrated with acrylic diffuser, translucent top, bottom clear, black powder painted finish tubular pole. The pole is made of GI tube with GI cylindrical control gear, 36 W CFL lamp and suitable for operation on 240 V 50 Hz single AC supply. The pole is to be fitted on 1:3:6 PCC pole foundation of size 300mm x 300mmx1200mm with grouting nuts & bolts as specified & directed by the deptt. (Metal Coats make) COBRA model or equivalent.
Construction of Functional Household Tap Connection including earthwork in excavation for pipe line (both for connection in distribution line and service connection) and refilling, dressing etc., providing PVC Saddle Piece of average size 110 mm x 15 mm (i.e. ranging from 63mm to 140mm) and make Supreme or equivalent, making holes in the distribution pipe, providing 15 mm dia bronze ferrule cock (PN-16) conforming to IS:2692 (1989) as ammended and make Zoloto or equivalent, connecting it to the saddle piece, providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PPR ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 of length 10m from saddle piece to the tap point ( pipes of make SFMC/ FUSION/Wetflow,Kisan brand or other brand of equivalent quality and PN-16 Pipe,20 mm OD,SDR-7.4) including all plain PP-R fittings and brass hreaded PP-R fitting and clamping, cutting and making good to the damages, including all threaded PP-R fitting and clamping, cutting and making good to the damages, including all taxes and duties as applicable and including the cost of all required labour and materials as directed and specified. The item also inludes construction and installation of R.C.C Hydrant Pillar of size 100mm x 100 mm , height 1200 mm with 6 mm dia bar embeded to RCC Post in proportion 1:1.5:3 with 4 nos 10 mm dia main and 6 mm dia stirrup @ 150 C/c and fixing 15 mm dia PPR pipe to the hydrant, with 6 mm rings embedded in concrete for anchoring inclusive of cost of transportation to site and also supplying fitting and fixing PVC Bib cock all complete as directed and specified. Approved good for construction drawing will be issued by the deptt.
Supply, installation, testing and comissioning of electrically operated chemical dosing pump of 6 L capacity and 6 kg/cm2 complete with PVC solution mixing container and electrical wiring with panel board fitting and fixing at site with suction and discharge tubings. Standard Materials for construction 1. Housing :- Fiber reinforced plastic 2. Spacer & Head :- Poly propylene/UPVC 3. Diapharm :- Tefflon Faced Hupalon 4. Ball :- PTFE 5. Suction & discharge ball cartidge :- Poly propylene/UPVC 6. Suction & Discharge Tubings :- HDPE/LDPE 7. MS Fabricated stand for mixing container
Making sign board of size 3 m (W) x 1.2 m (H) with 50 mm MS square pipe supporting postin a frame of 32 mm MS square boundary pipes with 3 nos 25mm MS square strut pipe welded with a 3 mm thick MS plain sheet (3 m x 1.2 m) including foundation work , all complete and as directed by the Engineer-in-charge.
Providing, installation, testing and commissioning of Bulk Flow Meter with removable mechanism class "B" confirming to ISO: 4064/1 including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipe line etc complete in all respect as per technical specification and as per direction of Engineer. BFM80 for DN 150 mm
Supplying making fitting and fixing 5- Leg Junction chamber made of GI Nipple (Medium quality) for regulating delivary of clear water supply ( The estimate is prepared as per APHE SOR 2015-16 and market price.
Wiring for light / fan / call bell point with 2x1.5 sq mm P.V.C. Insulated single core unsheathed industrial ( Multistrand) cable FR conforming to IS- 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel or Equivalent Make as approved by the Deptt. ) with flat 19 mm ISI marked casing "n"capping ( AKG/ Precision / Presto Plast/ Polycab / MW or equivalent make as approved by the deptt.) in surface system, including 6 Amp flush type switch. bell push ( Anchor Pennta / Gold medal / Kolor kany .Kom/ Havells or equivalent make as approved by the Deptt. ) etc. complete as directed and specified by the Deptt. 1.1.1 Short point up to 3.00 metre. Length.
1.1.2 Medium point upto 6.00 metre length.
Wiring to a 5 pin, 6 amps plug point with 1.5 sq. Mm PVC insulated single core unsheathed industrial ( Multistrand ) cable FR conforming to IS- 694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR Kabel pr Equivalent Make as approved by the Deptt. ) with flat 19 mm ISI marked casing "n" capping (AKG/ precision/ Presto Plast / Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch ( Anchor penta / Gold medal / Kolor kany. Kom / Havells or equivalent make as approved by the Deptt. 0 GI/ MS switch board (ISI marked 0 with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm . cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.8.1. with 2x2.5 sqmm+ earth continuity with 1x2.50 sqmm. in flat 19 mm ISI marked casing "n"capping system.
Supplying and fixing brass batten holder ( Anchor Penta PC CHERRY / Gold medal / Kolor kany. Kon / Havells or equivalent make as approved by the Deptt. ) including connection as approved by the Deptt. As required ( Without Lamp)
Supplying and fixing of 3 plate Ceiling Rose ( Anchor Penta PC CHERRY / Gold medal / Kolor kany. Kon / Havells or equivalent make as approved by the Deptt. ) on the existing block including connection as approved by the Deptt. Complete as required.
Supplying and fitting of 11/15 watt CFL lamp in the existing batten holder/angle holder/ decorative bracket/ bulk head fitting/pendent hllder etc as specified and directed by the deptt. Qty = 1x2 = 2 nos
Providing and fixing ICSP and N link main switch of 240 Volt grade (HPL / GECO / ANCHOR or equivalent make) including drilling boards / iron frames and fixing with bolts and nuts and connection as approved by the Deptt. complete as required . 12.1.3 60/63 Amps Capacity D. P.& N
Supply, installation & testing of G.I .earth station with perforated 40 mmdia and 4.50 Metre long heady G.I . Pipe with necessary 40 mm dia. G.I. Fittings such as Skocket, Tee. Slbow, nipple and 50mm x 40 mm G. I.j reducing socket for funnel including lockong arrangement 300mm x300 mmx6mm hinged ccover C. I. earth plate complete with digginh of earth pit, construction of brick chamber and plasrering of both inner & outer surface of wall as specified and directed by the deptt.
Supplying & laying of 40x6 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machinaries etc. complete with supply of Brass nuts & bolts, screws etc. including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. 1x5.00 = 5.00 M
Extra for using salt 5 kg and charcoal 64 k in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper earth drawn through 15mm dia . Medium quality G.I. Pipe from Earth Electrode ( below GL ) to electrical switch gears or electrical machineries including making necessary connection as approved , specified and directed by the deptt.
Providing and fixing I.C. Distribution fuse boards with rrewire able fuses 250 Volt grade, 16 Amps per way (HPL/GECO/ ANCHOR or wquivalent make ) including drilling boards/ iron frames and fixing with bolts and nuts and nuts and connection as approved by the Deptt. complete as requored. 12.4.3 4-way Capacity
Supplying with fitting & fixing sheet steel, phosphatised, powder painted Single door surface mounting MCCB enclosure of the following rating MCCB fitted on wall with grouting nuts & bolts as required complete with making necessary connection as approved, specified and directed by the deptt. 14.4.1.6 for 400/630A 3P/4P MCCB 1x1 = 1 No
Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod. Canopy etc. of following sweeps with maping necessary connections as approved by the Deptt. As required complete and as directed by the Department [Without regulator]. 27.1.6. Standard model 1200 mm Sweep (Usha make)/Standard model 1050/1200 mm Sweep (Havells make)/ High speed 1200 mm sweep (ORIENT PSPO make)
Supplying and fixing of 3 Pin Top 6/ 16 Amp on the existing 6/16 Amp Socket including connection as approved by the Deptt. complete as required.
Bipul Basumatary
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .