Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-Finance | ₹7.1 L | L1 | Accepted-Finance lowest bidder |
| 2 | L2₹7.1 LRejected-Finance | ₹7.1 L | L2 | Rejected-Finance bidder is not L1 |
| 3 | L3₹7.8 LRejected-Finance 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹7.8 L | L3 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹15,977
Closing Date
16 Dec 2025, 11:00 amClosed
EE-l CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) Kolkata
Air Conditioning arrangement at Quality Control Section of CMS Building, Kolkata.
2025_WBPWD_953903_1
WBPWD/EE-I/CKHED/eNIT66/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
CENTRAL KOLKATA HEALTH ELECTRICAL DIVISION
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,977
Central Kolkata Health Electrical Division
3 Feb 2026
19 Nov 2025
18 Dec 2025
19 Nov 2025
25 Nov 2025
9 Dec 2025
24 Nov 2025
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR Cable/KEI/ Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching colour) top cover 3 mm thick and incl.175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as to GS.
On board
Average run 9 mtr
Supplying & fixing of 250 volts, 50Hz, sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl.(Make-EPC) as to Gs.
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
38 cm Exhaust (15”) (380 MM)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - 415V, 25/35KA, 160A, FPMCCB [Legrand] (1 -nos) Outgoing - 10KA, (C-characteristics) 63A, TPMCB [Legrand] (2 -nos) SPMCB (6-32)6 nos
4 way [Legrand/ equivalent]
Supplying and fixing double door sheet steel (16SWG),powdercoated cableendboxforTPN DBhorizontal / vertical enclosurewith IP-42/43 protection,onangleironframeonwall&mending goodthedamagestooriginal finishwithnutsbolts etc incl. provision for earthing attachment 4 way
Supply and Delivery of 1.1 KV grade following sizes Al. armoured PVC/XLPE cable (Gloster/Havells/polycab/KEI) as mentioned below as per choise of EIC.
a) 4 Core 50 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.
a) 4 Core 95 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes,anticorrosive paste & jointing materials.
a) 4 Core 50 sqmm
Laying of cable above 3½ core50 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required to GS.
a) 80 mm dia Pipe ISI-Medium
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Cable/Finolex/ Polycab) in 20/25/32mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
a) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
a)4 x 6 sqmm + 2 x 4 sqmm ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2x2.5 sqmm+1x 1.5 sqmm ECC
a)4x6 sqmm+2x 4 sqmm ECC)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket , without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc (Make:- Legrand/Cabtree)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Norysis) & necy.Connections
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating on Angle iron frame
Supplying and fixing 63 A,415V MCB Isolator with PVC loop box necessary connection
Supply & Delivery of 230V, 1-Ph, 1200 mm sweep BLDC ceiling fan having Wattage ≤ 35 Watt, R.PM ≤ 360, Air Delivery ≥ 220 C.M.M incl. all accessories (Without Remote). (Make- Crompton / Usha / Orient) [BEE 5 star rated]
Supply & Delivery of 240V recess mounted 2'x2' LED downlight having following wattage in white powder coated pressure die cast aluminium housing , with glare free uniform illumination, suitable for 2' x 2' grid ceiling with CCT (5700K-6500K) having minimum luminous efficiency of 120 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] 24 Watt [LED lamps & accessories shall have BEE certification]for server room
Supply & Delivary 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. twin rotary compressor, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Mitsubishi-Electric) for seminar room and Ortho OT patient waiting room,
Supply & Delivery of 415V-3ph, 5TR /5.5 TR capacity ductable type Split Air Conditioner (3-Star rated) of rated cooling capacity of 60000 BTU/hr. / 66000 BTU/hr with 2Nos. twin rotary compressor/ scroll compressor (R-410A), 2 Air-flow/per IDU:- 1000CFM. Individual Wire Remorte ( Make: Hitachi/Mitsubishi-Electric)
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex)
a)4 core 2.5 sq.mm communication cable
Erection & Commissioning Charges of 7.5 TR AC machines incl. refrigerant R-410A / R-22 concealed type Split Air Conditioner
Erection & Commissioning Charges of 5.5 TR AC machines incl. refrigerant R-410A / R-22 concealed type Split Air Conditioner
S & L of Drain Water piping work out of HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
a) 25 / 32 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (50X50X6mm) for making platform for installation of outdoor unit of 5.5 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting(above 1 foot) the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 40x40x6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 3 Nos. (50X50X6mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.4Mtr. Structural design should be approved by E.I.C.
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75x75x6mm ) for making platform for installation of outdoor unit of 7.5 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting(above 1 foot) the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 40x40x6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 3 Nos. (75x75x6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.4Mtr. Structural design should be approved by E.I.C.
Cutting Iron window and Making door there for passege of outdoor maintenance.The charges of welder charges,mation charge, shifting, Fixing, labour charges and all material chips,Sand,Cement etc and mending good damages to original finish as per instruction of EIC
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_2284605.xls
BOQ • 0.25 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid