Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.3 LAccepted-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹16.7 L+₹2.3 L (16.4%)Rejected-AOC | L-2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹26.9 L
EMD Value
₹53,900
Closing Date
26 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, IDSE
GE Kaluchak PIN-900673 C/O 56 APO
REPAIR/REPLACEMENT OF UNSV SUMMAR/WINTER APPLIANCES AT ALL FORMATION OF UNDER GE KALUCHAK
2024_MES_679607_2
GE/KC-57/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kaluchak
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹53,900
Yes
14 Jan 2025
5 Nov 2024
28 Nov 2024
5 Nov 2024
26 Nov 2024
12 Nov 2024
Amount
Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade /body etc and replacement of components /accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation (bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance, complete all as specified & directed. Notes :- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only. (ii) Rewinding of fan motor, painting will be measured and paid separetly under relevant item of schedule. (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v) Repair works of fans should be completed and refixed the same within 12 hours after receipt of complaint slip. If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
All as per Serial Item No.01 above but exhaust fans 300mm/450mm sweep.
Taking out and removing burnt copper winding, cleaning the armature, rewinding the ceiling fan (1200mm / 1400mm sweep) armature with new super enamelled copper wire of existing gauge including supply and fixing necessary E Class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Rewinding of heavy duty exhaust fan motor of 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor and testing including removing burnt out copper winding wire from fan motor complete all as specified and directed.
Rewinding of heavy duty Exhaust fan motor 450 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from air circulator fan motor, complete all as specified and directed.
Supply only gun metal bush suitable for ceiling fan/ exhaust fan/ air circulator fan/ wall mounted fan of any sweep/ type /size, complete all as specified & directed.
Supply only Ball bearing No. 6201/ 6202/ 6203/ 6204 for ceiling fan, complete all as specified & directed.
Supply and fixing in replacement fan condensor of 2.5 MFD, 230 volt, AC, 50Hz conforming to IS:1709, complete all as specified & directed.
Supply and fixing in replacement fan condensor of 3.15 MFD, 230 volt, AC, 50Hz conforming to IS:1709 complete all as specified & directed.
Supply and fixing in replacement Electronic fan regulator stepped type with five step, two module, 100 Watt 240 volts complete all as directed.
Supply and fixing in replacement only PVC insulated flexible multistranded copper wire, three core of size 0.75 sqmm, complete all as specified & directed.
Supply and fixing in replacement PVC connector 4 way 6Amp with connection screws nuts etc complete all as directed.
Supply only PVC canopy set of two pieces for ceiling fans of any size complete all as directed.
Supply and fixing in replacement rubber reel with nuts bolts clamp and washers of suitable size for ceiling fan complete all as specified and as directed.
Louver shutter made of MS sheet metal 1.2mm thick for round base and 0.8 mm thick for flaps comprising of mounting legs frames made of MS flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50 mm long 8mm dia to be fixed on wall complete with using fastner bolt, drilling and duly painted by two coat of synthetic enamelled paint (spray painting ) over a coat of primer for exhaust fan up to 400 mm sweep including taking down old unserviceable, complete all as specified & directed.
Supply and fixing in replacement down rod made of MS pipe medium grade 15mm bore of 900mm long including drilling hole both ends & making slot in one end for fixing of ceiling fan of any sweep/type including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
GEYSERS Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 50 Ltrs comprising of the followings : (a) Inspection, taking down, opening or dismantling, de-scaling,brushing and thoroughly cleaning the storage tank up to the satisfaction of the Eng-in-charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing the washers/ gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point. (d) Checking, re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for it serviceability.
(g) Re-assembling the Geyser, re-installation and testing complete. (h) The rate for above item are deemed to include for transportation of geyser to the work shop as approved by Engr-in-Charge/GE for necessary repairs and testing of Geyser at workshop. (j) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (l) Repair works of geysers should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200. b) For second day Rs 300. c) For next every day Rs 500. NOTE:- Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item no. 17.
All as per Serial Item No. 17 above but 25 ltrs capacity.
Supply and fixing in replacement thermostat (Adjustable type) of Rod/stem Type EST-11EM, 20A resistive, 250 Volt, opening on temperature rise of approved make and having ISI mark, complete all as specified & directed.
Supply and fixing in replacement and fixing in replacement steel siphon geyser assembly 6/9 hole suitable for 50 ltrs capacity geyser of any make as required at site of approved make complete with inlet and outlet, provision for thermostat pipe with drain pipes & drain plug, screws, studs, clamps for fixing heating elements, gasket etc., complete all as specified & directed
All as per item No. 20 above but siphon assembly suitable for 25 ltrs capacity Geysers.
Supply only heating elements of capcity 1.5 KW, AC,240 Volts suitable for storage type electric water heater as per site requirement (press type / screw type / triangular / circular base or ceramic cartige type), ISI marked, complete all as specified & directed.
All as per item No. 22 above but of capacity 2 KW AC 240 Volts.
Supply and fixing in replacement gasket of thickness 5mm for geyser assembly of 09 holes/09 holes, complete all as specified & directed.
Supply and fixing in replacement geyser indicator pilot lamps (red and green lamps) with wiring, round/ square/ rectangle type suitable for geysers of any type/capacity, complete all as specified & directed.
Supply and fixing in replacement PVC connection pipe 15 mm dia, 450mm long with end nuts and washer, suitable for hot/Cold water outlet of geyser complete all as specified and directed.
SSupply and fixing in replacement PVC connection pipe 15 mm dia, 600mm long with end nuts and washer, suitable for hot/Cold water outlet of geyser, complete all as specified and directed.
Supply and fixing in replacement safety valve suitable for 25 Ltr/ 50 Ltr geyser all as specified and as directed.
Supply and fixing in replacement non return valve 15mm bore as in replacement of old one and connection and testing complete all as specified and as directed.
Supply and fixing in replacement plug top 3 pin 15 Amp, complete all as specified & directed.
Supply and fixing in replacement new 3 core PVC insulated copper cable size 2.5 Sq mm round 1100 volt grade as in connection, complete all as specified & directed.
Supply and fixing in replacement fastner mild steel 100/150/200mm long, complete all as specified & directed.
Supply and fixing in replacement Sheet metal enclosures single pole and neutral enclouser with a two pin and earth plug with socket complete with one double pole MCB 20 Amps, 240 volts including taking down old unserviceable sheet metal enclouser, complete all as specified & directed.
Supply and fixing in replacement Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal including taking down old unserviceable switch socket, complete all as specified & directed.
WATER COOLER Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position, capacity 40 ltr to 150 ltr, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. Note: (i) The replacement of defective / nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Replacement of unserviceable / damaged body portions of the water coolers shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item. (iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC.
(v) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.(vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line. (vii) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200/- b) For second day Rs 300/- c) For next every day Rs 500/-.
Cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the water cooler of 40/80 litres or 60/120 litres capacity to its rated capacity including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load, complete all as specified and as directed by Engineer in Charge. Note : The type of refrigerant gas (i.e R-12/R-22/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the water cooler of 150/150 litres capacity to its rated capacity including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load, complete all as specified and as directed by Engineer in Charge. Note : The type of refrigerant gas (i.e R-12/R-22/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed.
Supply only starting relay unit suitable for any type and make water cooler, complete all as specified & directed.
Supply only starting capacitor 40/60 MFD, complete all as specified & directed.
Supply only starting capacitor 60/80 MFD, complete all as specified & directed.
Supply only starting capacitor 80/100 MFD, complete all as specified & directed.
Supply only Running capacitor 10 to 15 MFD, complete all as specified & directed.
Supply only Running capacitor 20 to 36 MFD, complete all as specified & directed.
Supply only Thermostat , 220 volts suitable for water coolers upto 150 ltr cap, complete all as specified & directed.
Supply only over load protector relay (Suitable for any make / model of compressor), complete all as specified & directed.
Supply only AC electric condensor motor of 1/35 HP , SP 230 Volts, complete with blade complete all as specified & directed.
Supply only AC electric condensor motor of 1/7 HP , SP 230 Volts, complete with blade, complete all as specified & directed.
Supply only brass Nipple 15 mm dia for inlet and out let connection of water cooler any type / size including one PVC connection 15 mm dia with brass coupling on both ends, complete all as specified & directed.
Supply only Drain Pipe PVC flexible 25mm dia with one end circle clip complete all as specified and directed.
Supply only CP brass Push cock, 15 mm. Dia (ISI marked) inner/outer threaded complete all as specified and directed.
Supply only capillary tube suitable for any type and size of water cooler, complete all as specified & directed.
Supply only new sealed unit compressor for water coolers of any make and model as approved by GE including vacuum testing and filling of refrigerant gas to required pressure, complete all as specified & directed for the following capacity :-
Refrigeration compressor suitable for 40/80 ltr capacity.
Refrigeration compressor suitable for 60/120 ltr capacity.
Refrigeration compressor suitable for 120/150 ltr capacity. Notes for Srl item No 55-57 :- (i) The cost of fixing, brazing to suction and discharge line and testing of compressor at site is deemed to be included under Srl item No.59 of BOQ. (ii) Refrigerant gas for charging of compressors shall be measured and paid for separately under respective item of this BOQ.
Supply only stop valve/ globe valve with iron wheel head screwed both ends for iron pipe and fixed complete of size 15mm, complete all as specified & directed.
20mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), fixed in repairs, complete all as specified & directed.
DESERT COOLER Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position, strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, re-assembling & testing of the desert cooler all as specified and directed by Engineer-in-Charge. Notes: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item and replacement of unserviceable / damaged body portions i.e. panels / switch board / bottom / top / grills / frame etc. of the desert cooler shall also be measured and paid for separately under appropriate item of Schedule `A'. (ii) Burnt out fan windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iv) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200/- b) For second day Rs 300/- c) For next every day Rs 500/-.
Supply only PVC flexible water Pipe 15 mm dia including fittings suitable for desert cooler, complete all as specified & directed.
Supply only PVC distributor 3 way, 15mm dia for water distribution inside desert water cooler including clamping by screw/strip, complete all as specified & directed.
Supply only gun metal bushes for fan motor of desert cooler, complete all as specified & directed.
Supply only Ball bearing suitable for Desert cooler, complete all as specified & directed.
Supply only water lifting submersible pump 230 Volts AC 50Hz for desert cooler 1.5 mtr head, complete all as specified & directed.
Supply only blower fan motor 230V AC 50Hz, 150w to 180w for desert cooler complete with blade, locknut, and standard accessories as per OEM complete all as specified & directed.
Supply only PVC fan blade ( set of three blades) for cooler motor of any description to suit existing motor, complete all as specified & directed.
Supply only new wood pads of required size as approved (three in each on desert cooler), complete all as specified & directed.
REFRIGERATOR Disconnecting, dismantling and taking out the non-functional Refrigerators of any description, any make and in any position, capacity 165 ltr to 310 ltr, single phase, 50 Hz, opening, cleaning and servicing of the refrigerator with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling refrigerator and testing, complete as all specified & directed. Notes : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500. (iii) Replacement of unserviceable / damaged body portions of the Refrigerator shall also be measured and paid for separately under appropriate item of Schedule `A' as 'Supply only' but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item. (iv) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit. (v) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (vi) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only new compressor unit for 195 Ltr capacity Refrigerator, complete all as specified & directed.
Supply only new compressor unit for 310 Ltr capacity refrigerator, complete all as specified & directed.
Supply only new compressor unit for 280 Ltr capacity refrigerator, complete all as specified & directed.
Supply only blower fan motor suitable for refrigerator of cap 165 to 310 Ltr cap, complete all as specified & directed.
Supply only thermostat switch with defrosting arrangement suitable for Refrigerator of capacity 165 to 310 Ltrs, complete all as specified & directed.
Supply only starting relay suitable for refrigerator of cap 165 to 310 Ltr cap, complete all as specified & directed.
Supply only magnetised door lock rubber strip gasket set complete for refrigerator of cap 165-310 Ltrs, complete all as specified & directed.
Supply only freezer for Refrigerator 195 Lt capacity, complete all as specified & directed.
Supply only freezer for refrigerator for 280/310 Ltrs capacity, complete all as specified & directed.
Cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the refrigerator of any capacity ranging from 165 litres to 195 litres including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load, complete all as specified and as directed by Engineer in Charge. Note : The type of refrigerant gas (i.e R-12/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the refrigerator of any capacity ranging from 210 litres to 310 litres including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load, complete all as specified and as directed by Engineer in Charge. Note : The type of refrigerant gas (i.e R-12/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Supply only electric bulb SP 230 volts screw/Pin type with base, complete all as specified & directed.
Supply only over load protection for refrigerator of capacity 165 ltr-310 ltr, complete all as specified & directed.
DEEP FREEZER Disconnecting, dismantling and taking out the non-functional Deep Freezers of any description, any make and in any position, capacity upto 400 Lts, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the Deep Freezer with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling Deep Freezer and testing of the Deep Freezer complete as all specified and directed by Engineer–in–charge. Notes : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (iii) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
Supply only new compressor sealed unit for deep freezer 300/320 Ltrs obtained from the factory outlet /authorised dealer alongwith test certificate and with two year guarantee card and testing on full load, complete all as specified & directed. Note : Gas charging and gas shall be paid and measured separately under appropriate item of this Schedule.
Supply only blower motor 1/9 HP 230 volt single phase, complete all as specified & directed.
Supply only thermostat for Deep Freezer upto 320 Ltrs capacity, complete all as specified & directed.
Supply only starting relay suitable for deep freezer upto capacity 500Litres, complete all as specified & directed.
Supply only overload protector device for deep freezer upto 500 litres capacity, complete all as specified & directed.
Supply only Running capacitor for deep freezer upto 400 Litres capacity, complete all as specified & directed.
Supply only Starting capacitor for deep freezer upto 400 Litres capacity, complete all as specified & directed.
Supply & charging gas refrigerant (R-134A or OEM recommendatation) to deep freezer upto 400 Ltr capacity in required qty, complete all as specified & directed.
WINDOW / SPLIT AC Disconnecting, dismantling and taking out the non-functional Air conditioner window/Split type of any description, any make and in any position, 1.5/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and on site comprehensive servicing/maintenance of the AC with electric blower, water under pressure, descaling, brushing and cleaning using caustic soda/detergent powder solution,filter cleaning and replacing ,cleaning of condensor tubes,cleaning of cooling coil of evaporator,lubrication of fan motor ,checking and tightning all nuts and bolts etc,checking of electric circuit for smooth functioning of Air conditioner etc checking,taking out and removing unserviceable/ defective wiring & parts, painting the bottom with one coat of black synthetic enameled paint, replacement of the unserviceable and defective parts, brazing, reassembling(indoor/outdoor unit) and testing of the AC to make functional, complete all as specified & directed.
Notes : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (iv) The complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200/- b) For second day Rs 300/- c) For next every day Rs 500/-. (v) Equipment shall be serviced once in six month and no repeat maintenance shall be measured.
Supply only over load protector relay suitable for window/ Split type AC 1.5/2 TR capacity, complete all as specified & directed.
Supply only relay assembly 1.5 / 2TR Window AC including making necessary connections and testing, complete all as specified & directed.
Supply only running capacitor 36-60 Mfd, 230 Volts, suitable for window/Split type AC 1.5/2 TR, complete all as specified & directed.
Supply only starting capacitor 80-120 Mfd, 230 Volts, suitable for window/Split type AC 1.5/2 TR , complete all as specified & directed.
Supply only capacitor 4/6 Mfd, 230 Volts for blower motor, complete all as specified & directed.
Supply only thermostat switch suitable for window/Split AC 1.5/2 TR including making necessary connections and testing, complete all as specified & directed.
Supply only AC Electric Blower motor of 1/3 HP to 1/8 HP 230 volts 930 RPM, copper wound, 3 speed,single/double shaft as per existing model suitable for window type/Split type AC and capacity upto 2TR, complete all as specified & directed.
Supply only electrical wiring kit (PCB) of window/Split AC, complete all as specified & directed.
Disconnecting and taking out existing defective compressor of any description & in any position and supplying and fixing new Refrigeration Compressor obtained from factory outlet/ authorised dealer alongwith test certificates with two years guarantee card for any type of widow AC 1.5/ 2TR capacity, single phase, 230volt including brazing to suction & discharge line, replacement of capillary tube and dryer filter,replacement of foundation rubber pads,nuts and bolts ,vacuum testing with and including providing and filling/charging of refrigerant gas (R 134) & testing on full load, , complete all as specified & directed. Note : Rate of Refrigerant Gas shall be deemed included in quoted rate of this item.
All as per item No 101 above but for Split AC 1.5/2 TR.
Supply and charging (top up) of refrigerant gas R-134 or OEM recommended refrigerant to Window/Split AC upto 2TR to make up required pressure complete including cleaning/ flushing out the gas system with anti corrosive solution with anti moisture substance, condensor tubing by vacuumisation, pressure testing of the system, demoisturing the system, complete all as specified & directed.
Supply only synthetic rubber tube insulation of thickness 9mm and internal diameter 6mm / 13mm for refrigerant copper piping of split AC's, complete all as specified & directed.
Shifting of split type AC 1.5/2 TR capacity including dismantling all accessories indoor/outdoor unit, copper insulation, voltage stabilizer from position transportation to new location and reinstalling the all accessories as directed, grouting /fixing with nuts/bolts, complete all as specified & directed.
Shifting of Window type AC 1.5/2 TR capacity including dismantling from position transportation to new location and grouting /fixing with nuts/bolts, complete all as specified & directed.
Metallic plugs top of AC box 20A, 2P+E and connecting including taking down old unserviceable plug top, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, single pole & neutral, 6 to 32 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
VOLTAGE STABILIZER Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & strip opening of Voltage Stabilizer of 4/5 KVA single phase, air cooled, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unseathed stranded copper conductor cable of existing size, reassembling, connecting and testing including cleaning the exposed surfaces of stabilizers& applying a coat of synthetic enamel paint after preparation of old painted steel surfaces and writing MES No/SM No in different tint in the pattern & style all as directed by Engineer-in-Charge complete all as specified & directed. Notes : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iii) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200/- b) For second day Rs 300/- c) For next every day Rs 500/-.
All as per Item No. 110 above but stabilizer of capacity 2/3 KVA.
All as per Item No. 110 above but stabilizer of capacity 0.5/1 KVA.
Supply only the following new parts commonly used in the voltage stabilizer of any capacity (0.5 KVA to 5 KVA) & any type, complete all as specified & directed : -
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 4/5 KVA Stabilizer
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 2/3 KVA stabilizer
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 0.5/1 KVA stabilizer
M/S PRAJAPATI ENGINEERS (BID ID -3168932)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .