| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.4 L+₹1.1 L (3.47%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹32.0 L+₹1.7 L (5.55%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹32.8 L+₹2.5 L (8.19%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹34.5 L+₹4.1 L (13.6%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
6 Jun 2022, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA BATHINDA MIL STN
SPL REPAIR TO BLDG No. P-770 AT OTM-IV OF MED REGT AND ADDN/ALTN OF 02 X TOILET BLOCK AT BLDG No. P-706(ADM BLOCK) OF RKT REGT UNDER AGE BR-V AND AGE E/M OF GE NORTH BATHINDA AT BATHINDA MIL STN
2022_MES_523240_1
8937/NIT-07/22-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BATHINDA
Class D category a (i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹99,800
Yes
18 Jun 2022
10 May 2022
8 Jun 2022
10 May 2022
6 Jun 2022
24 May 2022
10 May 2022 - 17 May 2022
Amount
SCHEDULE 'A' B/R Works
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 100mm long complete all as specified & directed by Engineer-in-charge.
Supply only 100mm long powder coated mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 100mm long complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply and fixing factory made 105 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made 2nd class hardwood, rail and style, thickness of shutter 35mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treate, complete all as specified and as directed by Engineer-in-charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples including taking out old broken wire cloth any size complete all as specified & directed by Engineer-in- charge.
Supply & fixing in repair galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples including taking out old broken wire cloth any size complete all as specified & directed by Engineer-in- charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing by welding or riveting complete all as specified and as directed by Engineer-in- charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 300mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply and fixing extruded aluminium alloy handle fabricated type anodised 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing in repair, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing in repair, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones with oil putty complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 3mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material, oil putty complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 3mm thick figured glass pin head type in squares not exceeding 0.5sqm in each pane for steel or wooden doors/wondows including fixing material, in hacking out old one complete all as specified and as directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Digging out and removing sunken floor filling and deposited the same at a distance not exceeding 250m away from the outer edge of the bldg where directed, complete as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for sunken treatment to sunken floor, cleaning the surface by using wire brush, rendering to floor and sides with 10mm thick in cement mortar (1:4) including mixing of WPC in mortar @ 3% cement content, finished even and smooth without using extra cement, after that material and labour providing for applying two coats of two components one part liquide two parts powder) ready to use cementitious water proofing coating on properly prepared surface by brushing having elongation of > 50% for the applying water proofing treatment as per following on horizontal and verticle surfaces of sunken floor complete all as per manufacturer's instructions all as directed by Engineer-in-charge:- (i) Applying 1st coat of two components modified polymer coating. (ii) Provn of glasses fiber mess of 2 x 2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. Note:- (i) Complete treatment to be carried out by authorised applicator of water proofing manufacture (ii) WPC for mixing in CM shall be measured & paid separately as supply only
Material and labour for 30mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floor, sunken floor etc, finished rough to receive tiles, including mixing of WPC in mortar @ 3% of cement content, complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material & Labour for PCC (1:7:12) type F2 using 40mm graded stone aggregate as loose filling of sunken floors complete all as specified and as directed by Engineer-in-charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 20-25 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 20-25mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repair, 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repair, stop valve/angle valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair, cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repair, concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply & fixing in repair, brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, MS chromium plated, soap tray approximate size 160mmx160mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair, bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in repair, drapery curtain rod 19/20mm dia, fabricated out of mild steel pipe with PVC coating (ABS), wall thickness of pipe not less than 20 guage, including fancy type brackets and pair of decorated end knobs (finials), stop roller etc, fixed to wall for doors and windows cuttings as required and fixing at site complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 25mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 25mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, vitreous china wash hand basin oval type under counter, white colour, of size 595mm x 420mm x 200mm excluding taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ. Make :- Cat Part CNS-WHT-705 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in repair, vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including taking down old urinal with fittings complete all as specified & directed by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, rain water pipe, AC or Reinforced concrete) set in cement mortar, complete all as specified & directed by Engineer-in-charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm with integral foot rests (excluding flushing cistern, flush pipe above floor and trap), including demolation of tile, PCC, taking out old WC, taking out lime concrete filling and after fixing new WC re filling lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including fixing PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing before filling concrete and including all other connected work as required upto entire satisfaction of Engineer-in-charge complete all as specified and as directed by Engineer-in- charge. (NOTE : Tile work with screed shall be measured and paid separately under appropriate item of this schedule.
Supply & fixing in repair vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white or black colour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Dismantling and disconnecting of existing cast iron soil waste/vent pipe or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolts and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing in repair, 150mm x 150mm size salt glazed stone ware gully traps, square or round mouthed, type 'P' complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, 75mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair, 75mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing in repair, Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for cleaning top surface of concrete roof slab, lime terracing or surface of tiles with wire brush including flashing and junction of parapets etc., and surface painting with layer of blown grade bitumen of any penetration applied hot @ 1.20 Kg per Sqm and screed/rendering in 15mm thick in cement mortar (1:4), priming the surface @ 0.30 Kg per Sqm and laying 3mm thick APP based polymer membrane of weighing not less than 3.5 Kg per Sqm reinforced with polyster non woven fabric (weight not less than 150 Gm per Sqm ) laid on primed surfaces at by torch application with side overlap 75mm and end overlap 100mm and tucked into the chasesas a treatment for moderate condition complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with WPC @3% of cement content and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for 40mm thick brick tiles (old serviceable tiles obtained from demolition/dismantled item shall be reused) laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with WPC @ 3% of cement content and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 3% of cement content, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas, beams, staircases, landing, fins, facia and similar suspended works complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 25mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from ceiling surfaces by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth, and after preparing the surface smooth applying three coats of lime white wash with using paint brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying white wash as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying 3mm thick white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil bound distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Supply and fixed in repair, 150mm long Mild steel pressed handles window handle, oval type, stove enamelled black, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 5mm GI wire for tying mosquito nets in OR living fixing with angle and necessary fittings, complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement pillar tap cast copper alloy with capstan head, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Material and labour 20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
SCHEDULE 'A' ELECTRIFICATION WORKS
Taking down carefully existing unserviceable copper/aluminium point wiring (light/fan/socket or power point) complete with all accessories such as hylum sheet, switches, sockets, ceiling rose, wall brackets, regulator gang boxes etc & making good distrubed surfaces of walls/floor etc and matching with existing surface all as specified and directed by Engr - in- Charge
Material & Labour for point wiring complete with 1.5 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor FRLSH cable (ISI marked) 1100 volts in existing concealed surface conduit and existing shunken box covered with new 3mm thick bakelite laminated hylem sheet (ISI marked) for one light point /fan point/exhaust fan controlled by one switch including 1.5 Sqmm single core multi stranded FRLSH copper earth wire to common earth and connecting to earthh dolly complete all as specified and directed by Engr - in- Charge
All as per item No 115 here in before but one light point controlled by two two way switch complete all as specified and as directed by Engr - in- Charge.
All as per item No 115 here in before but for socket outlet 5 pin 5 Amp on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 115 here in before but for socket outlet 5 pin 5 Amp on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 115 here-in-before but socket out let one 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly conductor etc., complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 115 above but point wiring complete with 1.5 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor FRLSH cable (ISI marked) 1100 volts in new concealed/ surface conduit and new shunken box covered with new 3 mm thick bakelite laminated hylem sheet (ISI marked) for one light point/fan point/exhaust fan controlled by one switch including 1.5 sqmm single core multi stranded FRLSH copper earth wire to comman earth and connecting to earth dolly, complete all as specified and as directed by Engineer-in-Charge.
All as item No 120 here in before but for one socket outlet 3/5 pin 5/6 Amps 250 volts flush type on same board, complete all as specified and as directed by Engineer-in-Charge.
All as item No 120 here in before byt for one socket outlet 3/5 pin 5/6 Amps 250 volts flush type on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per No 120 here in before but for one socket outlet 6 pin, 6/16 Amps with cable 2.5 sqmm multstranded copper conductor FRLSH cable on the independent board including provision of 2.5 sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earh dolly, conductor etc., complete all as specified and as directed by Engineer-in-Charge.
Material and labour in provision of new point wiring complete with 1.5 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor FRLSH cable (ISI marked) in and including PVC concealed conduit 20mm dia (medium quality ISI marked) and conduit fittings including chases cutting and making good disturbed surface, complete all as specified and as directed by Engineer-in-Charge.
All as item No 124 here in before but for one socket outlet 3/5 pin 5/6 Amps 250 volts flush type on same board, complete all as specified and as directed by Engineer-in-Charge.
All as item No 124 here in before but for one socket outlet 3/5 pin 5/6 Amps 250 volts flush type on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per No 124 here in before but for one socket outlet 6 pin, 6/16 Amps with cable 2.5 sqmm multstranded copper conductor FRLSH cable on the independent board including provision of 2.5 sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earh dolly, conductor etc., complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, two way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type , single pole, one way, 15/16 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan, complete all as specified by Engineer-in-charge.
Supply and fixing in replacement Batten holder 2 Amp 250V AC with skrit ISI marked top line series , polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb, complete all as specified and as directed by Engineer-in-Charge. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply & Fixing sheet metal enclousers made out of CRCA mild steel sheet, IP-43 protection, flush mounted for metal door, powder coated DB VTPN 4 way, 415 V AC with 200 Amps rated bus bar, Double door, 8 + 12 module, dust and vermin proof suitable for incorporation of MCB's and isolator etc. including taking down old unserviceable DB, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 4 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement MCB TPN 63 Amps, 10 KA 'C' curve 415 V AC, 50 Hz including necessary attachment, including taking down unserviceable old MCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SPN 40-63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment, including taking down unserviceable old MCB, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SPN 32 Amps, 10 KA 'C' curve 240 V AC, 50 Hz including necessary attachment, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module, including taking down unserviceable old MCB, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through existing PVC conduit, independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including taking out old sub main wiring of any conductor any size from conduit and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour in provision for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing in replacement wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing in provision of wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector, complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing Sleek Pressue die cast aluminium housing, heat resistant glass, energy saving, IP-65 protection, better optics for uniform distribution street/Roadway luminaire with high power LED 25/35 Watt compete fitting with driver, LED strip and all other accessories etc. suitable GI bracket and making electric connection with using twin core copper cable of suitable size including taking down old unserviceable light fitting any type complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing LED mirror light fitting 9/10 watt, 6000 K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying and testing cable for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core including taking down unserviceable Service cable from pole to bldg all as specified and directed..
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
Taking down ceilling fan from site and keep in safe custody/store for reuse the same as same location after the building work. Before reinstall the same will be new spray painted as per existing colour compelete all as directed by Engineer-in-Charge. If any damages of fans and its connected acessories at the time of transportation/deposit to store, the contractor will response the same included in the quoted rate.
Hanging only ceiling fan after completion of ceiling work refix the fan item retrived from item No 160 above. Provision of connection wires and fixing arrangements and any painting works are included in quoted rate.
Supply and fixing provision of exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, metallic body heavy duty, aerodynamically designed having noise level not exceeding 45-50mm DB, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
M/s MITTAL CONSTRUCTIONS
G N CONSTRUCTIONS
K L JINDAL AND CO.
Easyways Enterprises
M/S VIAJY BUILDERS & DEVELOPERS
M/s Kamal Constructions
M/s PANKAJ KUMAR
M/s Balvinder Singh Engineer and Contractors
M/s Vandana Builders
VISHAV CONSTRUCTIONS
Aman Enterprises
M/s Kamal Builders
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .