Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.5 L+₹78,350 (2.73%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹32.6 L+₹3.9 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹32.7 L+₹4.0 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹37.4 L+₹8.7 L (30.2%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Mar 2025, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
REPAIR MAINT OF HEATING COOLING APPLIANCES AND OTHER CONNECTED WORKS UNDER GE MIS MHOW
2025_MES_698162_1
8744/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
270 days
GARRISON ENGINEER (MIS)
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹80,000
Yes
19 May 2025
15 Feb 2025
20 Mar 2025
15 Feb 2025
18 Mar 2025
4 Mar 2025
Amount
Attending the complaints of non functional and Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 ltrs comprising of the following tasks at different locations of any make with technecian team (one electrician and one helper) attend the complaint regularly. Technecian team will collect the complaint from AGE E/M No. 1 office regularly and feed back of the complaint will be submitted on same day complete all as specified and as directed. The following points to be included in quoted rate :- (a) Inspection of geyser after opening bottom cover plate. (b) Examine water tightness of storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands of defective taps to ensure water tightness smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats and test its functioning. (h) Checking and adjustments of pressure reducing valves. (i) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked. (j) Testing of Geysers after repairs/maintenance complete in all respect for proper functioning.
Taking down storage geyser of any capacity after disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection for repair/ replacing the unsv items and assemble the same after making serviceable, cleaning dust including connecting flexible 3 core cable as required, painting the geyser complete, with white colour synthetic enamel paint by spraying and filling cavaties with pillar, one coat after cleaning all dust, with proper filling of glass wool as heat resistance material, suitable quantity etc and refixing the geyser at it's original location complete all as directed spcified by Engineer-in-charge
Supply and fix heating element push type 1.5 KW ISI Marked complete all as specified and directed .
Supply and fix heating element push type 2 KW capacity complete all as specified and directed .
Supply and fix heating element triangle type 2.0 KW ISI Marked complete all as specified and directed .
Supply and fix heating element triangle type1.5 KW capacity complete all as specified and directed .
Supply and fix heating element thread type 1.5KW with ISI Mark complete all as specified and directed .
Supply and fix heating element thread type 2 KW capacity complete all as specified and directed .
Supply and fix Thermostat ISI marked suitable for the Geysers 25 ltrs/ 50 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed .
Supply and fix Thermostat ISI marked suitable for the Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed .
Supply and fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement complete all as specified and directed .
Supply and fix PVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 45 cm long for hot water as per requirement complete all as specified and directed .
Supply and fix PVC connections pipe (braided coated) with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for hot water as per requirement complete all as specified and directed .
Supply and fix Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed .
Supply and fix Indicators of Geysers of any capacity/type as per requirement complete all as specified and directed .
Supply and fix Cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100 Volts grade complete all as specified and directed. Make- Finolex/Havells/Policab
Supply and fix 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty complete all as specified and directed . Make- Westen/Havells/Anchor
Supply and fix Geyser storage inner tank made out of copper sheet suitable for 25 ltrs capacity complete all as specified and directed .
Supply and fix Geyser storage inner tank made out of copper sheet suitable for 50 ltrs capacity complete all as specified and directed .
Supply and fix Apparatus plate copper of Geysers of any capacity/ type complete all as specified and directed .
Supply and fix Safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed .
S&F in repairs electric saving five star / Four star rated 2 KW rated power water heater storage type (Geyser) of capacity 25 Ltrs with all accessories complete including making water and electric connection all as required at site including 04 Nos of old fashner nuts required suitable size fixed in brick wall including complete all as specified and directed by Engr-in- Charge Make:- Jaquar Model- Elena Vertical or equivelent in Havells model- Bianca Note: Old unserviceable Geysers will be deposited by the contractor in MES store yard.
Attending the complaints of non functional and Preventive maintenance of solar water heating system/ Solar flat plate collector comprising of the following tasks at different locations of any make, Technecian team will collect the complaint from AGE E/M No. 1 office regularly and feed back of the complaint will be submitted on same day complete all as specified and as directed. The following points to be included in quoted rate :- (a) Inspection of solar heating system and find out leakage in system (b) Examine water pipe line (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands of defective taps to ensure water tightness smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats and test its functioning. (h) Checking and adjustments of pressure reducing valves. (i) Checking all electrical connection to ensure proper functioning. (j) Cleaning all glass plate (k) Testing of solar heating system after repairs/maintenance complete in all respect for proper functioning.
M&L for repair the unserviceable solar water heating system and de-scaling with authourised agent and making serviceable by filling the Distilled water, cleaning the solar toughned glass, stopping the leackage with replacing the old unserviceable CPVC pipe/tee/bend/broken glass tubes etc. complete all as specified and directed. Note1 :- The contractor ensure that all materials/spares once the incorporated in the work, they should maintain warranty for the same through the contract period from the date of executing.
Supply & Fix Heating element as per sample including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 2000 watts and connected items all as specified and directed by engr-in- charge.
Supply & fix Heating element as per sample including rubber washers (ISI marked) of any type suitable to existing Solar water heater of capacity 3000 watts and connected items all as specified and directed by engr-in- charge.
Supply & fill Distilled water in sealed containers and connected items all as specified and directed by engr-in- charge.
Supply & fix Gl tubing medium grade 15mm bore with fitting and connected items all as specified and directed by engr-in- charge Make- Tata, Swastik, Jindal, Prakash, Surya.
Supply & fix Gl tubing medium grade 25mm bore with fitting and connected items all as specified and directed by engr-in- charge Make- Tata, Swastik, Jindal, Prakash, Surya.
Supply & fix Bib taps 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down,screwed for iron pipe or for unions and connected items all as specified and directed by engr-in- charge . Make- Prayag /Jaquar or other make as specified in Particular specifications.
Supply and fix Stop valves 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed by engr-in- charge. Make- Prayag /Jaquar or other make as specified in Particular specifications.
Supply and fix Stop valves 25 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed by engr-in- charge. Make- Prayag /Jaquar or other make as specified in Particular specifications.
Supply and fixing in replacement of 16 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed. Make- Finolex/Surya or other make as specified in Particular specifications.
Supply and fixing in replacement of 25 mm external dia Chlorinated Poly Vinyl Chloride (CPVC) pipe consisting of high grade polymer effectively bonded in the inside and outside of an aluminium tube CPVC-AL-CPVC by melt adhesive(including joining/fixing with cement solvent) suitable for hot water supply from solar water heater to the bathrooms and fixed to wall, ceiling etc. including all materials, fittings and fixing works and testing of pipe line test for solvent cement joints and adhesive joints and testing of all materials shall be as per manufactures instructions, literature and confirming to IS-15450 : 2004 or ASTM -1282 including making good the disturbed surfaces complete all as specified and directed. Make- Finolex/Surya or other make as specified in Particular specifications.
Supply and fix in replacement Float valves 15 mm with complete accessories all as specified and directed by Enge-in-charge. Make- Prayag or other make as specified in Particular specifications.
Supply and fix in replacement Float valves 25 mm with complete accessories all as specified and directed by Enge-in-charge. Make- Prayag or other make as specified in Particular specifications.
S & F in repairs MCB SP 6 to 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. Make - HPL/L&T/ Havells
S & F for MCB Single pole and neutral rated capacity 6 to 32 Amps, 240 volts breaking capacity 10 KA complete all as specified and as directed. Make: ABB/L&T/Schneider
S & F for MCB Four pole rated capacity 63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. Make: ABB/L&T/Schneider
S&F in repairs Sheet metal inclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELLSs /Legrand/Standard.
S&F in repairs Metal clad plug, top 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete. Make:- HAVELLSs /Legrand/Standard.
Supply and fix single core PVC insulated and sheathed cable with multistranded aluminium condutor of size 10 Sqmm Weather proof flat twin core cable for service connections from pole to Distribution board complete all as specified and directed Make:- HAVELLS / Finolex/Policab
M&L for sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit.
M&L for point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in walls not less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 amps socket point on independent board controlled by one switch.
S & F in replacement of 100 LPD Puf insulated stainless steel hot water storage tank for 100 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S & F in replacement of 200 LPD Puf insulated stainless steel hot water storage tank for 200 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
S & F in replacement of 300 LPD Puf insulated stainless steel hot water storage tank for 300 LPD solar water heater storage tank material 316 grade stanless steel outer clading material powdar coated GI sheet with inlet and outlet water connections. complete all as per site requirement and directed by Engr-in-charge.
M&L for maintanance and servicing of following mentioned OT light fittings including control panel, suspension spring including all connected items and carring out routing check OT lights for smooth functioning all as per menufacturer instructions and entire setisfaction of engr-in-charge:- (a) Unserviceable spares which are required to be replaced shall be measured and paid saperately in relevent items (b) Authourised personel should repair the unit (c) Clean the light housing and arm using mild soap and sterlized water mixture. Apply this mixture to a clean cloth and wipe down the light head and arm (d) Check frount lens and optics to ensure there are no chips,cracks or other (e) Check to see that all mounting and attachement screws, wisher etc are in place securely tightened. Replace any missing screw retighten as required.
(ii) OT-II
(iii) OT-III
(iv) OCU
(v) MI Room
(vi) Family Ward
S&F in replacement of switching mode power supply and connected items all as specified and directed by engr-in- charge
S&F in replacement of reusable sterile handle and connected items all as specified and directed by engr-in- charge Make- Philips /Havells/Crompton/ Bajaj
S&F in replacement of lower glas assembly and connected items all as specified and directed by engr-in- charge Make- Philips /Havells/Crompton/ Bajaj
S&F in replacement of cabling and teflon wiring of 1.5 Sqmm to 2.5 Sqmm wiring complete and connected items all as specified and directed by engr-in- charge
Supply and Fix in replacement of Projection Lamp for operation surgical light Type 7027 Cat Part No BRL/BCD AI/220 of 12 V, 50 Wand 50Hz frequence and connected items all as specified and directed by engr-in- charge Make- Philips /Havells/Crompton/ Bajaj
S & F in replacement of Electronic Transformer Dimming by normal' phase-cut' dimmer short circuit and over voltage protection. Working with Main supply 240 v, 50-60 Hz , Lamp power 50 w, Lamp voltage 12 v Ac. and connected items all as specified and directed by engr-in- charge Make- Philips /Havells/Crompton/ Bajaj
S & F in replacement sensing card of online UPS 5KVA including cleaning, dusting and tightness of all electrical connection Make - Microtech all as specified and directed by engr-in- charge
S & F in replacement Sealed lead acid battery type EP 100-12 12 volt 100 AH for suitable to UPS 5 KVA including all electrical connection Make - Exide,amron,sonic all as specified and directed by engr-in- charge
S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 2000 ltrs complete all as directed at site. Make- Syntex, Suprime or make as specified in Particular specifications
S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs complete all as directed at site. Make- Syntex, Suprime or make as specified in Particular specifications
M&L for steel section Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified & directed.
Supply install tesing and commisssioning Hepa filters Iframe with CRCA Steel casing with epoxy powder coated/Aluminium of imported micro fibre glass media with efficiency 99.97 down to 0.3 micron of size 610x305x150mm including taking down unserviceable one all as specified. Make: AEROSOL / MAF / DYNA / JOHNFLOWER
M&L Removing the burnt/defective sealed compressor unit of any make from Window type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5522 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site.
All as per item No 62.00 above but Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh Kirloskar, Model RNB 5529 complete all as directed at site.
M&L Removing the burnt/defective sealed compressor unit of Split type make from any type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing new sealed compressor unit make - Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500 by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site.
All as per item No 64.00 above but Air conditioner of 2 ton capacity and sealed compressor unit complete all as specified and direct ed at site. Make - Tecumseh, Model AW-2000
Testing and Repairing leakage in system Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete.
All as per item No 66.00 above but Air conditioner of 2 ton capacity complete all as specified and direct ed at site. gas F-22 (approx 2.30 Kg) complete.
S&F in replacement of electric blower motor capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
Supply & fixing in replacement thermostat for window type AC, working on SP, 230V,AC Make : Indfos/ Ranutrol, complete all as directed at site.
Supply & fixing in replacement of PCB circuit with remote control for air conditioner of 1.5 Ton / 2.0 Ton any Make and capacity complete all as specified and direct ed at site. Make : Voltas/Carrier/Ranutrol/LG/Blue star
Supply & fixing in replacement air filter for split type Air conditioner (set of three Nos) Make-Marcon or Equivalent complete all as specified and direct ed at site.
Supply & fixing in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and direct ed at site. Make : Marcon
Supply & fixing in replacement starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and direct ed at site. Make : Asian/Empire
Supply & fixing in replacement starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and direct ed at site. Make : Asian/Empire
Supply & fixing in replacement running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
Supply and fixing of copper filter pencil type to any make and capacity of air conditioner complete Make : Vaishali Metal complete all as specified and directed.
S&F in repair front grill of PVC for window type AC of any make complete all as specified and direct ed at site. all as per existing grill
S&Fin replacement outdoor unit of split AC 1.5 Ton, 5 star rating Make- Voltas/LG/ Samsung with complete sealed compressor unit capacity 1.5Ton and blower ,condenser connecting suction and discharge lines initially filled with refriigeratin gas complete all as directed.
Supply and fixing relay over load protector complete set suitable for AC complete all as specified and directed at site.
Supply & fixing in replacement relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
S&Fin replacement indoor unit suitable for 1.5 TR split AC 5 star rating make- voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
S&Fin replacement indoor unit suitable for 2.0 TR split AC 5 star rating make- voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
S&Fin replacement outdoor unit of split AC 2.0 Ton 5 star rating make- voltas/LG/ Samsung with complete sealed compressor unit capacity 2.0 Ton and blower ,condenser connecting suction and discharge lines initially filled with refriigeratin gas complete all as directed.
M&L for taking down split type AC complete with connectted electric wires, copper tubing, insulation sleeves, outdoor fitting bracket from exiting place and the same fitted to as per requirement/ handed over site,and after fitting complete AC from one place to another place, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including copper tubing up to 2 running mtr (in replacement), after exceeding 2 Running mtr it (Copper tubing) should measured and paid separately, cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 2 Kg) in air conditioner 1.5 Ton to 2.0 ton completeall as per directed by Engr-in Charge
M&L for Servicing of AC Window/Split type any capacity including water wash of indoor ,outdoor and all filters using air blower and high pressure Jet pump including all aggrengement for servicing of air conditioner i e ladder,water tank, pattey repairs ,tightening of plugs,etc helper with technician included in quoted rate no any extra charges paid to contractor by department complete all as specified directed
S&F in repairs Copper tubing of following size complete:-
(a) 3/8” size
(b) 5/8 ” size
(c) 1” size
(b) 1/4 ” size
(c) 1/2” size
Supply and charging of gas R 134a in AC plant of any capacity complete all as specified and directed by Engr-in-charge. Note:- Gas will be accepted in sealed and tested cylender .
Repair of existing operating pannels of air conditioner (cold store) of capacity 1.5/2 TR and making complete incoming and outgoing connections complete all as specified and directed by Engr-in-charge.
M&L for profile insulation of outdoor unit complete all as specified and directed.
S&F of AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per sample complete all as specified and directed.
S&F of the following parts and fixed complete all as specified and directed.
a. Hand shut valve of size 5/8" Make- Synergn
b. Pressure gauge (0-500 PSI)
c. Valve 3 way
d. Flair nut 3/4" brass
e. Dead plug (brass)
f. Union
M&L for Modular Switch socket combination 20 Amp, 230 volts AC, fixed in repairs complete.
Supply & fixing in replacement Complete motor assembly kit of 1/7HPor 200 watts motor, 230V AC, copper winding, complete clamps=04 Nos and water fan 18" sweep Make GE Motors/ Crompton/ Havells Mark complete all as specified and direct ed at site.
Supply & fixing in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC Make : Crompton/cool- Home/GE Motors/ISI Marked complete all as specified and direct ed at site.
Supply & fixing in replacement wood-wool pad complete heavy size (set of three pads) Approx wt 400 Gms complete all as specified and direct ed at site.
Supply & fixing in replacement capacitor 6 MFD, 440V, Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark complete all as specified and direct ed at site.
Supply and fix of Desert cooler electric driven single phase having norminal air flow capacity of 5400 CuM per hour (peak), Honycab cooling media, water storage storage tank capacity 95/100 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 95 or eqivelent/Symphony/Blue star
Supply and fix of Desert cooler electric driven single phase having norminal air flow capacity of 5600 CuM per hour (peak), Honycamb cooling media, water storage storage tank capacity 65 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 65 NEO or eqivelent/Symphony/Blue star
Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia complete etc Make : GE Motor/AUE complete all as specified and directed
All as per item No 105.00 above but 1/20 HP 1350 RPM with fan of 13" dia complete all as specified and directed.
All as per item No 105.00 above but 1/35 HP, 1350 RPM with fan of 10" dia complete all as specified and directed
All as per item No 105.00 above but 1/83 HP 1350 RPM and fan of 9" dia complete all as specified and directed.
Supply & fixing in replacement starting capacitor 40 to 60 MFD, 275 volts Make- Sharda/Empire/Bhel etc complete all as specified and directed.
All as per item No 109.00 above but of 60 to 80 MFD complete all as specified and directed.
Supply & fixing in repairs running capacitor 10 MFD 440 volts AC Make: EPCOS/ Capro /Asian etc complete all as specified and directed.
Supply & fixing in repairs running capacitor 15MFD complete all as specified and directed.
Supply & fixing in repairs running capacitor 25/30 MFD complete all as specified and directed.
Supply & fixing in replacement thermostat for water cooler up to 150 ltr capacity. Make : Ranutrol/Danfoss/Indfos etc complete all as specified and directed.
Supply & fixing in replacement push cock heavy duty brass Chromium plated 15mm bore Make- Plumber/Jaquar as approved by GE. complete all as specified and directed.
Supply and fixing of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or Equivalent as approved by GE. complete all as specified and directed.
Supply and fixing starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
Supply and fixing in repairs of over load protector for compressor of water cooler complete all as specified and directed.
Supply and fixing of copper filter pencil type to any make and capacity of water cooler etc complete Make : Vaishali Metal complete all as specified and directed.
Supply and fixing in replacement of capillary tubing having 0.050/0.055 bore complete Make : Vaishali Metal complete all as specified and directed.
Supply & fixing in replacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5Mtr long complete all as specified and directed at site.
M&L Removing the burnt/defective sealed compressor unit of any make from water cooler cap 60 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit make : Kirloskar/Emmerson model : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed at site.
All as per item No 122.00 above but water cooler capacity 80 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461 etc complete.
All as per item No 122.00 above but water cooler capacity 150-150 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and direct ed at site.
Supply & fixing in replacement cable PVC 3 core flexible heavy duty copper 2.5 Sqmm complete Make :Plaza/Finolex /Havells complete all as specified and directed.
Supply & fixing in replacement single core copper conductor insulalated 2.5 Sqmm complete Make : Plaza/Finolex /Havells complete all as specified and directed.
Supply & fixing in replacement cable PVC 4 core flexible heavy duty copper 4 Sqmm complete Make : Plaza/Finolex /Havells complete all as specified and directed.
Repairing Testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 ltr capacity
All as per item No 128.00 above but 150 Ltrs. complete all as specified and direct ed at site.
Repairing of bottom base and legs of water cooler by suitable welding work complete all as specified and directed.
M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing complete
Supply & fixing in replacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 complete all as specified and direct ed at site.
Supply & fixing in replacement of thermostat Auto defrost type complete for Deep freezer (Refrigeration of)any make & capacity Make : Ranutrol/Indfos etc complete all as specified and direct ed at site.
M&L for removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts. Supply and fix of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415 incl necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete all as specified and directed at site.
All as per item No 134.00 above but compressor Make-Tecumseh Model TSK-1350 complete all as specified and direct ed at site.
Supply and fixing relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and direct ed at site.
Supply & fixing in replacement of drier filter complete set suitable for deep freezer 215 / 386 ltrs complete all as specified and directed at site.
Supply, fixing & testing of blower motor for Deep frizer SP 230V 20 watts complete with fan complete all as specified and directed
S&F Relay current type and overload protector complete suitable for compressor model KCE336, KCE345 fixed in repairs complete all as specified and direct ed at site.MAKE : Ranutrol/ Voltas /LG
S&F Thermostat auto defrost type, fixed in repairs for refrigerators any make & capacity 165/310 Ltr Rerfrigerator complete all as specified and direct ed at site. MAKE : Danfos/Ind foss/Ranutrol
Supply and fix Vegitable tray as per sample and suitable for refrigerator Make Godrej, Voltas or whirlpool , LG of capacity 300 Ltr
Supply and fix refrigerator of 3 Star, Smart Inverter Compressor, Convertible, Shiny Steel Finish, Frost-Free Double Door capacity 345 Ltrs complete al as specified and directed Make LG model No- GL-S382SPZX or whirpool /Samsung
S&F Evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs 165/286/300 ltr complete all as specified and directed at site .
M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity (165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of refrigerent gas 134a complete all as specified and directed at site.
Supply and charging / toping up of gas Freon- 22 with required standared pressure in Split AC of any capacity complete all as specified and directed. Note:- Gas will be accepted in sealed and tested cylinder having capacity 13.6 Kg each.
M&L for checking of AC supply electrical/electronics circuitary and finding fault and rectification the same with replacement of step down transformer 230 volt to 12/24 volts,replacement of faulty PCB of water purification system, and replacement of resistance , small pieces of wires etc complete all as directed .
Repair/maint of water purifier installed in various building of Infantry school and MH area including sypply and replacement of candle 10'' filter set and cartrige, carbon filter and pri filter complete all as directed. Make- Aqua guard/ Beetek
S&F in repair of Aquaguard Aura 2X Life, Needs No Service for 2 Years | Unconditional Warranty for 2 Years (Filters included) | 8-Stage Purification | RO+UV+Active Copper+Taste Adjuster |Suitable for all Water Sources complete all as directed. Make- Aqua guard/ Beetek
Repair of water purifier and replacement of solonoid valve, PF nozzle, EVA tube, boul set etc installed in various building of Infantry school and MH area and made functional complete all as directed. Make- Aqua guard/ Beetek
M&L Checking the unserviceable plant (such as water cooler, refrigerator, Deep frizer etc) of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor. Cost of the same is deemed to be included in the quoted unit rate.
ANISH KUMAR SINGH (BID ID -3259286)
Vinayak Trading House (BID ID -3265341)
Ms Kailash Chandra Babulal (BID ID -3260030)
ENVIRO TECH SERVICES (BID ID -3258133)
sanjay traders (BID ID -3260419)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .