Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.1 LAccepted-AOC 369 KRISHNA BHAVAN DHARMSALA ROAD CINEMA CHURAHA HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹31.2 L+₹16,000 (0.51%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹31.4 L+₹32,000 (1.03%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹33.9 L+₹2.8 L (9.07%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹34.3 L+₹3.2 L (10.2%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | 5 | Rejected-Finance Not L1 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
1 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
PROVN OF TROLLEY MOUNTED CAPTIVE POWER SUPPLY SYSTEM OF 320 KVA CAPACITY FOR MAIN RECEIVING STATION (MRS) AT LUCKNOW CANTT UNDER GE (E/M) LUCKNOW
2024_MES_640263_1
CWE/LKO/EM/T-121 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M LUCKNOW
₹64,000
Yes
20 Mar 2024
2 Feb 2024
8 Mar 2024
2 Feb 2024
1 Mar 2024
16 Feb 2024
2 Feb 2024 - 16 Feb 2024
Amount
Supply, installation, commissioning and testing of silent Diesel Engine driven factory assembled floor mounted, generating set of capacity 320 KVA, 3 phase, 4 wire, 415Volt 50Hz, 1500 RPM ,direct injection, water cooled , multy cylender, inline, storke confirming to ISO 3046/BS5514 with Mechancial FIP,electronic governor, turbocharger, pluse tuned exhuast mainfold complete with safety control and metering equipment mounted on common base frame on trolley system required at site and as recommended by manufacturer complete all as specified and directed :- Diesel Engine Gen Set shall comprising of the following:- A. DIESEL ENGINE. (a) Fly wheel to suit flexible coupling. (b) Flexile coupling with guards. (c) Dry type air cleaners with filters. (d) Lubricating oil filter, fuel filter, fuel pre filter. (e) Anti-vibration pads-quantity and type as recommended by manufacturer. (f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. (g) Electric start equipment.
(h) Lead acid storage maintenance free battery (12Volts- 02 Nos) of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: Exide/Amron or equivalent along with copper battery lead and connector. (j) Battery rack made out of MS angle iron to hold two nos batteries of suitable rating. (k) Standard safety device. (l) Daily service fuel tank of suitable capacity with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. (m) Exhaust silencer (n) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temperature, coolant temperature, fuel level, battery charging ammeter, battery charging lamp and inceptor lamp (RYB), panel duly prewired and displaying protection and safeties as under:- (aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. (bb) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level.
B. ALTERNATOR. Alternator 320 KVA with control panel as per IS: 4722 should be brushless alterrnator, self-excited, self regulated, Class H insulation limited to temp rise of class H, salient pole revolving field, single bearing, automatic voltage rugulator with volatage (380-440) Volts, 50 HZ, current @0.8 PF 448 Amps type 4 pole, roatating field exciter type- brushless (PMG optional), leads : qty/type-6 fixed optioanl 12 reconnectable , voltage regulator-solid state, insulation -class H, Temperature rise (deg C) 62.5, bearing qty/type-1,sealed , coupling -flex disc voltage regulation : NO load to full load - 2 P sensing ± 1%, one step load acceptance -100% of rating unblanced load cpacility -25% of rated current. C. ACCOUSTIC ENCLOSURE. Engine -Alternator assembly mounted on AV mounts with silencer and S.S exhaust bellow suitabley optimized to meet stringent noise emission standard as laid down MOEF/CPCB, Base rail with draw out type fuel tank provided with drain plug, air vent,inlet and outlet connections ,level inidcator,mail whole, sub base fule tank with 11 hours capcity at 75% load, (12 volts dry batteries-two nos) with connecting leads and terminals , 90% gloss RAL9003 white pure polyester powder coated, base in black colour , water and lub oil drain outlets located on the outer surface-leading to ease of maintenance and cleanliness.
Acoustics enclosure of suitable size to accommodate DG set 320 KVA, modular construction, fabricated out of 14/16 gauge (1.6mm/2mm) thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy.Textured insulation material as per IS 8183 comprising of fire retardant resin,organic glass/rock fiber ensure uniform long lasting absorption of sound to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at five meter to be 75 decibels @ five meter in line as per CPCB norms.
Supplying ,jointing and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured,electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 300 sqmm 3.5 core.
Material , labour and fabrication of trolley suitable to accommodate 320 KVA DG Set having dimention not Less than 5.5Mx3M. Trolley made of MS Sheet, MS Plate ,MS channel, MS Angle etc. The trolley provided with following:- (a) 04 Nos wheels on back side axal two each side including tyre and tube of make CEAT/MRF/Bridge Stone (b) 02 Nos wheels on front side axal one each side including tyre and tube of make CEAT/MRF/Bridge Stone. (c) Towing hook made of MS channel/angle iron, fixed with trolley for easy movement from one place to another place complete all as specified and directed by EIC. (d) Supply and fix Leaf spring set (Kamani U clamps suitable to bear the load of 320 KVA DG set with fuel . (e) supply and fix axal as per requirement. (f) Supply and fix danger notice plate on each side of trolley . (g) Supply and Fix Suitable breaking system. Note. Contractor will provide drawing of trolley with specification for approval of GE E/M Lucknow before fabrication. Trolley shall be capable to take min load 10 Ton . Any other work/item not mentioned above but required during fabrication of trolley cost of the same shall deemed to be included in the quoted rates.
Prime power system
ANKIT SHIP REPAIRERS AND SUPPLIERS
FUTURE Inc.
Diamond Electric Co.
OM NAMAH SHIVAY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .