Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | ₹7.0 L | L1 | Accepted-AOC OK |
| 2 | L2₹7.8 L+₹75,589 (10.8%)Rejected-Finance H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | ₹7.8 L+₹75,589 (10.8%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹8.5 L+₹1.5 L (21.1%)Rejected-Finance | ₹8.5 L+₹1.5 L (21.1%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹8.7 L+₹1.7 L (23.7%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | ₹8.7 L+₹1.7 L (23.7%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹9.2 L+₹2.1 L (30.4%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹9.2 L+₹2.1 L (30.4%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
3 Aug 2021, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Repair/maint of LT/UG cables, LT ACSR conductor, LT panel and connecting work at AFS Darbhanga under GE (AF) Bihta.
2021_MES_457653_1
8160/BHT/DBG/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
AGE B/R Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹20,000
Yes
8 Sept 2021
6 Jul 2021
5 Aug 2021
6 Jul 2021
3 Aug 2021
19 Jul 2021
Amount
Dismantling of unserviceable worn out/weathered/damaged ACSR conductor, service feeder of any size from pole after disconnecting of jumpers and insulator bindings complete all as directed.
Material & labour for aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator of any size as required at site complete all as specified and as directed.
Dismantling cross arm of MS channel or angle, clamp etc of any section from the pole complete all as directed.
M&L for cross arms, bracings, suports, clamps, back plates etc., fabricted with strututral steel sections including bolts, nuts, washers etc., welding , bending cold or hot,drilling holes for bolts,in any shape or size,as indicated or as directed and inclusive of one coat of primer , one under coat , and finishing coat of paint complete all as specified and as directed
S&F for danger Notice board , LT, 440 volts , of size 20 Cm X 15 Cm, 1.6 mm thick, mild steel sheet , vitreous, enameled white with letters , figures and conventional skull and bones in signal red colour and fixed with clamps, bolts, nuts of approved size complete all as specifed and as directed.
S&F for LT Insulator type , 1100 volts grade, of size 100 mm height , 65 mm dia , porcelain, vitreous, white or brown,including one galvanised mild steel spindle , two galvanised iron washers and one galvanised iron nut, bolts etc complete all as specified and as directed .
S&F for LT Insulator Shackle type ,1100 volts grade, of size 90mm dia, 75 mm height , porcelain, vitreous, white or brown,including galvanised mild steel strapsof size 31 X 3 mm , 12 mm dia insulator bolts, washers and nut, bolts etc complete all as specified and as directed .
M&L for Cradles hexagonal or rectangular fabricated with galvanised steel wires 4 mm or 3.15 mm dia for road crossings, between HT and LT conductors on same supports etc complete all as specified and as directed.
Taking out old unserviceable cable from tenches/pole etc
Supply and laying XLPE insulated, armoured heavy duty electric under ground cable with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core complete all as specified and as directed.
All as per serial item No 10 here-in-before but of cross sectional area 16 Sqmm 2 Core.
.All as per serial item No 10 here-in-before but of cross sectional area 25 Sqmm 4 Core.
All as per serial item No 10 here-in-before but of cross sectional area 50 Sqmm 3.5 Core.
All as per serial item No 10 here-in-before but of cross sectional area 95 Sqmm 3.5 Core.
Supply and fix on pole / wall or laying in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed :- (a) 40 mm bore dia
(b) 50 mm bore dia
(c ) 100 mm bore dia
Excavation In trenches not exceeding 1.5 mtr. In depth and not exceeding 1.5 mtr. in width and getting out in soft/loose soil for laying of cables/pipes, erection of poles, stays, cable fault detection etc complete all as specified and as directed.
Returning filling of excavated soil including spreading leveling, watering, well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and as directed.
Removing excavated materials/ surplus soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr. high from starting point complete all as specified and as directed.
Supply & laying clean river sand in trenches as cushioning for protection of cable 8 cm before laying of cable and 15 cm after laying of cable and punned as specified in SSR Part - I complete all as specified and as directed. Note:- For payment only punned depth shall be measured.
Supply & laying sub - cleans 'B' bricks (old size bricks) laid flat perpendiculor to direction of cable for protection of cable complete all as specified and as directed.
Supply and fix in repair MCCB 4 pole, 415 V, adjustable type125 Amp with braking capacity 16KA complete all as specified and as directed. Make : Havells Cat No IHLASF0125 or equivalent and approved model of L&T/Scheineder/Legrand
Supply and fix in repair MCCB 4 pole, 415 V, adjustable type63 Amp with braking capacity 16KA complete all as specified and as directed Make : Havells Cat No IHLASF063 or equivalent and approved model of L&T/Scheineder/Legrand
Supply and fix in repair MCCB 4 pole, 415 V, adjustable type 200 Amp with braking capacity 36KA complete all as specified and as directed Make : Havells Cat No IHLCNF0200 or equivalent and approved model of L&T/Scheineder/Legran
Supply and fix in repair MCCB 4 pole, 415 V, adjustable type 400 Amp with braking capacity 36KA complete all as specified and as directed Make : Havells Cat No IHLCNF0400 or equivalent and approved model of L&T/Scheineder/Legrand
Labour only required for re-stretching/ restringing of existing loosed / sagged ACSR over head conductor of any type and size including supply and binding wire/aluminum tape of required size, opening from insulators as fixed on pole after taking proper electric shut down from concerned staff including taking down unserviceable conductor from OH line and proper binding with additional conductor and restringing on line, complete all as directed by Engineer-in charge.
S & F in repair change over switch in steel sheet enclosure with side of handle operation 200 Amps type(SCHS), 415 V AC 50 HZ, four poles complete all as specified and as directed Make " Havells IHBFFE0200 or equivelant model of L&T /Legrand
S & F in repair change over switch in steel sheet enclosure with side of handle 100 Amps type(SCHS), 415 V AC 50 HZ, four poles complete all as specified and as directed Make " Havells cat No : IHBFFE0100 or equivelant model of L&T /Legrand
S & F in repair change over switch in steel sheet enclosure with side of handle 63 Amps type(SCHS), 415 V AC 50 HZ, four poles complete all as specified and as directed Make " Havells cat No : IHBFFE063 or equivelant model of L&T /Legrand
S & F in repair change over switch in steel sheet enclosure with side of handle 32 Amps type(SCHS), 415 V AC 50 HZ, four poles complete all as specified and as directed Make " Havells IHBFFE032 or equivelant model of L&T /Legrand
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25x4mm, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
SHIV SHAKTI TRADERS
ROSHAN LAL AHUJA
U k Enterprises
PAPPU ROY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .