| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | ₹3.8 L | L1 | Accepted-AOC Details uploaded |
| 2 | L1₹17.3 LAccepted-AOC | ₹17.3 L Quoted ₹45.7 L | L1 | Accepted-AOC Details uploaded |
| 3 | L1₹43.1 LAccepted-AOC 181 BANGUR AVENUE BANGUR AVENUE BANGUR AVENUE KOLKATA WEST BENGAL 700055 | 24 PARAGANAS NORTH | WEST BENGAL | 700055 | ₹43.1 L Quoted ₹65.2 L | L1 | Accepted-AOC Details uploaded |
| 4 | L1₹43.3 LAccepted-AOC 301 AURA BIPLEX ABOVE KALAYAN JEWELLERS RAMNAGAR LANE SV ROAD BORIVALI WEST MUMBAI MAHARASHTRA 400092 | MUMBAI SUBURBAN | MAHARASHTRA | 400092 | ₹43.3 L | L1 | Accepted-AOC Details uploaded |
| 5 | L2₹8.5 LRejected-AOC 1 BISHNU RABHA PATH GUWAHATI KAMRUP ASSAM 781028 | KAMRUP METRO | ASSAM | 781028 | ₹8.5 L | L2 | Rejected-AOC L2 |
Tender Value
₹1.3 Cr
EMD Value
₹6.5 L
Closing Date
21 Sept 2021, 4:30 pmClosed
Principal AMC Dibrugarh
Assam Medical College Hospital Dibrugarh
Equipment for the ICMR NER-Task
2021_HFWD_22677_1
No.2021/AMC/15001 dtd. 23/08/2021
Open Tender
Laboratory and scientific equipment
Supply
60 days
Deptt. of Microbiology AMC Dibrugarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Principal AMC Dibrugarh
₹6.5 L
Office of the Principal AMC Dibrugarh
9 Dec 2021
25 Aug 2021
22 Sept 2021
26 Aug 2021
21 Sept 2021
3 Sept 2021
2 Sept 2021
Items :
Phadia 200 (Propriety Item)
Real-Time PCR; Specifications: An automated system for both PCR and post-PCR end-point analysis, using in-built Peltier based PCR machine; The system should support applications including absolute and relative quantification, multiplex PCR allelic discrimination, melt curve analysis, pathogen detection and plus/ minus assays using an internal positive control; Peltier thermal cycling for Fast-PCR as well as Standard-PCR run available in the same block. 40 cycles in less than 30 minutes; The system should have temperature range of 3-99 degrees C with Maximum ramp rate of at least 5°C /second; Should have a reaction volume of at least 50 µl; The system should support micro well plates, individual tubes and 8-tube strips; The system should provide Touch Screen LCD feature to avoid dependency on computer for operation; Should also be possible to use a computer for system control, operation, analysis and networking of multiple system; Instrument should be supplied with a separate Desktop along with a standalone backup system capable of providing at least 90 minutes of backup time; USB port for data export to Power point, Excel or JPEG formats should be present; It should be an open system to use reagents from any manufacturer; System should be calibrated for common dyes of broader wavelength excitation and emission spectrum; Excitation Light source –Laser / LED; Change of position, block or chemistry should not require calibration or tools; The system should be capable of operating at ambient temperatures of 20-30 degrees C; Temperature gradient function should be available in the system; Temperature uniformity should be ± 0.4°C & control accuracy ± 0.1°C to 0.3°C; Temperature increments should be min. of 0.1 °C/cycle & Time increments should be min. 1 s/cycle; It should have at least 5 Chanel multiplexing capability in a single tube; Instrument should not require the use of a reference dye such as ROX and do not need regular calibration; Instrument should use an advanced optical system; It should do Scanning just above the sample & should guarantees the homogeneous excitation of each individual sample and the reliable recording of the emitted fluorescent signals with high sensitivity and no crosstalk between wells. Should have a warranty period of at least 3 years and should include on-site installation and training.
Lyophilizer; Specifications: Should be fully automated, user friendly; Should have Seamless stainless-steel condenser; Should have a freeze drying area of 0.12 meter square, Should have 4 trays with 8 manifold port; Should have Compact design and operation- suitable for any Laboratory; Should have microprocessor control with alarm; Should have digital Temperature read out; Should have Faster drying rate and reproducible drying; Should have an air cooling system; Should have a cold trap temperature of <=56 deg C; Should have a cold trap capacity of 8-10 litres; Should be capable of processing biological samples with diverse range of solvents; Vacuum pump specifications: Vacuum pump should be chemical resistant. The items such as vacuum hose, various filters for vacuum pump, drying chamber, rubber valves, etc which is necessary for the smooth operation of the instrument should be included; Accessories: All accessories with spare parts for immediate and smooth functioning of the system.Should provide onsite installation & training; Should have at least 3 years warranty
HPLC; Specifications: HPLC system should also work in UHPLC mode w/o changing any part; System should be upgradable for hyphenation with LC-MS/MS or HRMS from the same manufacturer; The pump must have variable/adjustable Gradient delay volume to support different applications; The pump must have independent compressibility irrespective of mobile phase composition without any pulse dampner mode; System should be upgradable to feature of monitoring solvent/buffer monitoring facilities; pH Range of the system must be from 1-12 including components like Loop, Injector Valve and injection wetted parts; The column compartment should have both; Still air for highest efficiency and forced air for easiest method transfer facility or any better technology; The column oven should have passive pre-heating facility; Basic instrument control of the column compartment should be achieved by a keypad; The column compartment must provide a software-supported predictive performance function for scheduling maintenance procedures; The Column Oven must have built in safety features like Leak detection and safe leak handling, excess pressure monitoring; • Multiple Photodiodes for better spectral resolutions bringing 0.6nm spectral Band width or better; The detector must provide a software-supported predictive performance function for scheduling maintenance procedures; The Detector must have built in safety features like Leak detection and safe leak handling, excess pressure monitoring; • License version of Chromatography data system software.with gradient Profile programming 1-9 or better; Software with integrated relational data base; The software should be a original licensed copy software with specific part number mentioned in the offer; Chromatography data system software for control, acquisition, processing, & reporting; Software should have capability to control third party HPLC and GC Hardware; It must record instrument event such as injection, complete instrument settings, changes & conditions in real time; Should be connected to a PC with a backup system for the PC; Shpuld have SPE Vacuum Manifold with SPE Cartridge for 2000 samples (Drugs analysis); Suitable oil -free vacuum pump; Sample & Solvent filtration kit with pump; Should provide on-site installation and training; Should provide a warranty for 3 years.
Refrigerated Centrifuge; Specifications: Compact refrigerated centrifuge with CFC free refrigerant; Should have max. speed of 16,500 rpm with an accuracy of +/-10 rpm; Should have ability to spin for a time of 1 min-99 hr 59 min, short and continuous run; Should provide a temperature range of -20 deg C to +40 deg C; Centrifuging chamber should be made of stainless steel; Should have powered lid locking; Should have quick and easy operation with the knob; The rotors should be changed easily; Should have Lid locking; Should have Emergency lid lock release function; Should provide imbalance and lid locking protection; Should have automatic rotor recognition; Should provide onsite installation & training Should have at least 3 years warranty
Minus 80°C Deep Freezer; Specifications: Should have temperature control/display, temperature range: -50 °C to - 86°C; Capacity cu ft/litres: 350 or more; Should have voltage: 230V, 50/60 Hz; Should have heavy gauge, cold rolled steel cabinets with a powder coat paint finish for a uniform exterior that resists chipping and rust; Should have 5” (12.7 cm) foamed-in-place polyurethane insulation; Should have vacuum relief port for easy access after door openings; Should have easy to remove washable filter for protection from dust on the condenser and increasing refrigeration performance; Should have single hand operation with an easy-to-use padlock-compatible, ergonomic door handle with integrated key lock; Should have microprocessor control and monitoring system to ensure that all controls and displays are easy to reach and read; Should have power management system with low voltage surge protection; Should have safety-backup systems for additional sample protection in the event of power or mechanical failure; Should provide onsite installation & training; Should have at least 3 years warranty
Minus 20°C Deep Freezer; Specifications: The deep freezer should have atleast 600 Ltrs of capacity; Should have Temperature control system with microprocessor PID control; Control of temperature within 3 °C of set temperature; Doors should have triple gasket system to prevent any leakage; Doors should have polyurethane insulation; Should have Audio Alarm System, in case of i) high and low temperature ii) open doors iii) Power failure; Should provide onsite installation & training; Should have at least 3 years warranty
BOD Incubator; Specifications: Should have a temperature range: -10 deg C to +60 deg C; Should have a temperature uniformity of +/- 0.1 deg C; Should have a LED display; Should have a PID temperature control device; Should have adjustable shelves; Should have a volume of 55-60 litres; Should have overheat protection system; Should provide onsite installation & training; Should have at least 3 years warranty.
ELISA Reader; Specifications: Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD 2; Should have accuracy of ≤1.0% at 490 nm; Should have precision of atleast 1.0%; Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm included filters; Should have a minimum of 3 speed plate shaking with adjustable duration of 0–999 sec; Should have five measurement modes including end point, kinetic, spectra, kinetic spectra and multipoint; Should have Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths; Should have USB interface with PC or Mac data stations for data output; Should be able to store data for assay protocols; System should come with a comprehensive software package allowing colorimetric and turbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix, normalization, and curve fit; Software should have the functionality of flexible template creation; Should provide onsite installation & training; Should have at least 3 years warranty
ELISA Washer; Specifications: Should be an automatic washer compatible with strips and 96-well microplates that have flat/U/V bottom wells; Should have programmable needle positions (horizontal or vertical) to an accuracy of at least 0.1 mm for bottom washing, crosswise aspiration, and overflow washing; Should have Dispensing speed control; Should have plate shaking option to help minimize bubbles and adherence of liquid to well sides; Should have wash bottle sensor to detect high waste liquid levels; Should have easily removable 8 or 12 way manifolds; Should have removable and autoclavable plate carrier; Should have an aerosol protection cover; Should have integrated vacuum and dispensing pumps to ensure accurate and quiet washing and to eliminate the need for external pumps; Should have on-board software capable of storing wash protocols; Should provide onsite installation & training; Should have at least 3 years warranty
Biosafety cabinet; Specifications: Should have a safety height opening of not more than 8.2”; Should have a max opening of not more than 425 mm; Should have HEPA Filter with 99.9 % efficiency at 0.3 µm with filter life indicator; Should have motorized window with laminated glass and Anti-UV coating; Should have UV lamp with life indicator; Should have LED lamp illumination; Should have LCD display showing UV lamp working time, inflow and downflow velocity, temperature, humidity, and working time; Should provide onsite installation & training; Should have at least 3 years warranty
Gel Documentation System; Specifications: Should have option for chemiluminescence, fluorescence, and digitization; Should have different mode of operation (standard/programmed); Should have Peltier cooled CCD camera; The system should have Motorized zoom option; Should have UV and white light trans-illuminator; The system should have different Epi light; The system should have GFP filter, Etbr filter; Should have option for automatic and manual exposure; Should have adjustable manual exposure time; Should have option for auto, manual focusing; Should have option for brightness control; Should be supplied with all the accessories required for calibrating the instrument; Should have sample trays for UV, white, Epi light; The system should be supplied with the analysis software; The system should have option for 3d imaging; The system should have LCD touch display; The system should be supplied with necessary PC required for image analysis; Should provide onsite installation & training; Should have at least 3 years warranty.
Molbiogen
M/S SATI DRUGS and SURGICALS
PRIYO SCIENTIFIC
BIOLAB EQUIPT PRIVATE LIMITED
SUDARSHAN PHARMA INDUSTRIES LTD
B. M. Pharma
NJD TRADERS
BIOAPPS
United Traders
Molbiogen
BIOAPPS
B. M. Pharma
M/S SATI DRUGS and SURGICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .