Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC L1 Tenderer |
Tender Value
Refer Docs
EMD Value
₹16,555
Closing Date
7 Jan 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
TNPDCL/Nagercoil
Works Contract for the execution of various works under Thuckalay Division, Kanyakumari EDC
2024_EB_513389_1
KKEDC/ETW-55/2024-2025 DT 23.12.2024
Open Tender
Electrical Works
Works
90 days
Office of the Superintending Engineer/Nagercoil
As specified in tender
3 documents required · 3 mandatory
₹0
₹16,555
Yes
3 May 2025
23 Dec 2024
8 Jan 2025
24 Dec 2024
7 Jan 2025
24 Dec 2024
24 Dec 2024 - 6 Jan 2025
Loading&unloading of all REC, RCC pole above 8 m length
Excavation of pole pits for pole above 8 m length by using JCB/Manual
Erection of RCC,REC,PSC poles above 8 m length by using crane or manual
Loading&unloading of all REC, RCC pole upto 8 m length
Excavation of pole pits for pole upto 8 m length by using JCB/Manual
Erection of RCC,REC,PSC poles upto 8 m length by using crane or manual
Transportation of all types and sizes of poles and other associated materials from road side to pole pit and vice versa upto 0.50KM
Erection of metal support above 9m/RSJ/Rail pole/Tubular polw
Erection of V X arm 4.5 feet
Fixing of HT/LT TI fittings
Erection of Tapping channel X arm
Fixing of HT pin insulator with pin 11 KV
Fixing of HT strain disc 11KV
Fixing of LT S phase cross arm
Fixing of LT 3 phase cross arm
Fixing of LT pin insulator
Fixing of shackle
Fixing of aluminium knob
Excavation of stay pit of 4.5' to 5' depth using JCB/Manual
Erection of stay set complete with fixing up stay wire Eye, Bow, Guy shackle, Binding etc
Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or equivalent conductor
Paving and stringing of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor.
Paving and stringing od conductors of 7/4.09mm ACSR or other equivalent conductor
Earthing of poles with GI wires 4 or 6 SWG by coil earthing
Loading&unloading of line materials
Erection of Distribution Transformer structure complete as per TNEB standard including painting, feeders arrangement, colour washing of RCC poles etc Fixing of poles type to be unit HT/LT LAS and jumpering 3 Nos earth pits with earth trough except erection of Distribution Transformer
Erection of 11KV single pole structure including erection of DT complete without center support
Erection of 11KV single pole structure including erection of DT complete with center support
Erection of 25 KVA Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa
Erection of 25 to 100 KVA Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa
Erection of 100 to 250KVA Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa
Loading&unloading of Distribution Transformer upto 100KVA
Loading&unloading of Distribution Transformer upto 250KVA
Transporting of Distribution Transformer/Line materials from stores to office/ site up to 20 Km distance by engaging 1 Ton capacity Minidor(Lorry)
Erection of DP structure with stay as per TNEB standard including fixing of top channel, cross bracing, concreting, painting, color washing etc with 11KV AB switch using all type of poles of size 9.14m and above length
Fixing of two tapping cross arm per cut point upto 33 KV line including fixing of Disc insulators and Jumbering etc
Street light Switching point arrangement
Drilling/less than 23mm hole per hole/slatted hole
Ordinary tree clearance
Erection of Single phase Service connection
Erection of Three phase Service connection
Dismantling & refixing of V cross arm,4.5 feet
Dismantling & refixing of HT/LT TI fittings
Dismantling&Reerection of Tapping channel X arm
Dismantling & refixing of LT S phase cross arm
Dismantling & refixing of LT 3 phase cross arm
Dismantling& reerection of stay set complete with fixing up stay wire Eye, Bow, Guy shackle, Binding etc
Dismantling & refixing of LT pin insulator
Dismantling & Restringing of conductors of sizes upto 7/2.59 mm ACSR or equivalent conductor
Dismantling& Restringing of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor.
Dismantling& Restringing od conductors of 7/4.09mm ACSR or other equivalent conductor
Dismantling and reerection of 1*40W tube light in complete set (including transport)
Dismantling of Distribution Transformer structure complete as per TNEB standard including painting, feeders arrangement, colour washing of RCC poles etc Fixing of poles type to be unit HT/LT LAS and jumpering 3 Nos earth pits with earth trough except erection of Distribution Transformer
Dismantling of 25 to 100KVA Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa
Dismantling of 100 to 250KVA Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa
Dismantling of HT/LT TI fittings
Dismantling of V X arm 4.5 feet
Dismantling of HT pin insulator with pin 11 KV
Dismantling of HT strain disc 11KV
Dismantling of LT S phase cross arm
Dismantling of LT 3 phase cross arm
Dismantling of aluminium knob
Dismantling of LT pin insulator
Dismantling of shackle
Dismantling of stay set complete with fixing up stay wire Eye, Bow, Guy shackle, Binding etc
Dismantling of 9mtr RCC,REC, PSC &metal pole including the closing of the pit
Dismantling of 8mtr RCC,REC, PSC &metal pole including the closing of the pit
Dismantling of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor.
Dismantling of conductors of sizes upto 7/2.11&7/2.59 mm ACSR or equivalent conductor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .